Search NASA⌕ Search

SEARCH · Search NASA

Results for “protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Installation protocol for charge transfer dissociation mass spectrometry on ion trapping mass spectrometers

Abstract Rationale Charge transfer dissociation (CTD) is a novel fragmentation technique that demonstrates enhanced structural characterization for a wide variety of molecules compared to standard fragmentation techniques like collision‐induced dissociation (CID). Alternative fragmentation techniques, such as electron transfer dissociation, electron capture dissociation, and ultraviolet photodissociation, also overcome many of the shortfalls of CID, but none of them are a silver bullet that can adequately characterize a wide variety of structures and charge states of target compounds. Given the diversity of structural classes and their occasional obstinance towards certain activation techniques, alternative fragmentation techniques are required that rely on novel or alternative modes of activation. Methods Herein, we present a step‐by‐step protocol for the installation of CTD on a quadrupole ion trap mass spectrometer and best practices for optimizing the signal‐to‐noise ratio and acquisition times for CTD mass spectra. Results In addition to two CTD installations in the Jackson laboratory, CTD has also been installed, and is currently in operation, on two 3D ion trap mass spectrometers in France: one in the laboratory of Dr. David Ropartz and Dr. Hélène Rogneaux at INRAE in Nantes, and the other in the laboratory of Dr. Jean‐Yves Salpin at Université d'Évry Val‐d'Essonne, part of the Paris‐Saclay University system. Conclusions Here, we provide a visual protocol to help others accomplish the instrument modification.

47 OTHER INSTRUMENTATION↗

A traversable wormhole teleportation protocol in the SYK model

In this paper, we propose a concrete teleportation protocol in the SYK model based on a particle traversing a wormhole. The required operations for the communication, and insertion and extraction of the qubit, are all simple operators in terms of the basic qubits. We determine the effectiveness of this protocol, and find a version achieves almost perfect fidelity. Many features of semiclassical traversable wormholes are manifested in this setup.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An exactly solvable quench protocol for integrable spin models

Quantum quenches in continuum field theory across critical points are known to display different scaling behaviours in different regimes of the quench rate. We extend these results to integrable lattice models such as the transverse field Ising model on a one-dimensional chain and the Kitaev model on a two-dimensional honeycomb lattice using a nonlinear quench protocol which allows for exact analytical solutions of the dynamics. Our quench protocol starts with a finite mass gap at early times and crosses a critical point or a critical region, and we study the behaviour of one point functions of the quenched operator at the critical point or in the critical region as a function of the quench rate. For quench rates slow compared to the initial mass gap, we find the expected Kibble-Zurek scaling. In contrast, for rates fast compared to the mass gap, but slow compared to the inverse lattice spacing, we find scaling behaviour similar to smooth fast continuum quenches. For quench rates of the same order of the lattice scale, the one point function saturates as a function of the rate, approaching the results of an abrupt quench. The presence of an extended critical surface in the Kitaev model leads to a variety of scaling exponents depending on the starting point and on the time where the operator is measured. We discuss the role of the amplitude of the quench in determining the extent of the slow (Kibble-Zurek) and fast quench regimes, and the onset of the saturation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Comparison of Transjugular and Plugged-Percutaneous Liver Biopsy in Patients with Contraindications to Ordinary Percutaneous Liver Biopsy and an 'In-House' Protocol for Selecting the Procedure of Choice

The purpose of this study was to evaluate the effectiveness and safety of transjugular liver biopsy (TJLB) and plugged-percutaneous liver biopsy (PB) in consecutive patients with severe liver disease associated with impaired coagulation, ascites, or both and to verify the in-house protocol used to select the appropriate procedure. In 2000-2006, 329 patients (208 male [62.8%] and 121 female [37.2%]), aged 1 month to 81 years (mean, 46.8 years), underwent 150 TJLBs (39.1%) or 233 PBs (60.9%) procedures at a major tertiary center, as determined by an in-house protocol. The groups were compared for specimen characteristics, technical success, and complications. Technical success rates were 97.4% for TJLB (146/150) and 99.1% for PB (231/233). TJLB was associated with a lower average core length (1.29 vs. 1.43 cm) and lower average number of specimens obtained (2.44 vs. 2.8), but both methods yielded sufficient tissue for a definitive diagnosis. There were no major complications in either group. TJLB and PB can be safely and effectively performed for the diagnosis of hepatic disease in patients with contraindications for standard percutaneous liver biopsy. When both are technically available, we suggest PB as the procedure of choice, especially in transplanted livers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Solving iTOUGH2 simulation and optimization problems using the PEST protocol

The PEST protocol has been implemented into the iTOUGH2 code, allowing the user to link any simulation program (with ASCII-based inputs and outputs) to iTOUGH2's sensitivity analysis, inverse modeling, and uncertainty quantification capabilities. These application models can be pre- or post-processors of the TOUGH2 non-isothermal multiphase flow and transport simulator, or programs that are unrelated to the TOUGH suite of codes. PEST-style template and instruction files are used, respectively, to pass input parameters updated by the iTOUGH2 optimization routines to the model, and to retrieve the model-calculated values that correspond to observable variables. We summarize the iTOUGH2 capabilities and demonstrate the flexibility added by the PEST protocol for the solution of a variety of simulation-optimization problems. In particular, the combination of loosely coupled and tightly integrated simulation and optimization routines provides both the flexibility and control needed to solve challenging inversion problems for the analysis of multiphase subsurface flow and transport systems.

54 ENVIRONMENTAL SCIENCES↗

MRI Guidance for Accelerated Partial Breast Irradiation in Prone Position: Imaging Protocol Design and Evaluation

Purpose: To design and evaluate a magnetic resonance imaging (MRI) protocol to be incorporated in the simulation process for external beam accelerated partial breast irradiation. Methods and Materials: An imaging protocol was developed based on an existing breast MRI technique with the patient in the prone position on a dedicated coil. Pulse sequences were customized to exploit T1 and T2 contrast mechanisms characteristic of lumpectomy cavities. A three-dimensional image warping algorithm was included to correct for geometric distortions related to nonlinearity of spatially encoding gradients. Respiratory motion, image distortions, and susceptibility artifacts of 3.5-mm titanium surgical clips were examined. Magnetic resonance images of volunteers were acquired repeatedly to analyze residual setup deviations resulting from breast tissue deformation. Results: The customized sequences generated high-resolution magnetic resonance images emphasizing lumpectomy cavity morphology. Respiratory motion was negligible with the subject in the prone position. The gradient-induced nonlinearity was reduced to less than 1 mm in a region 15 cm away from the isocenter of the magnet. Signal-void regions of surgical clips were 4 mm and 8 mm for spin echo and gradient echo images, respectively. Typical residual repositioning errors resulting from breast deformation were estimated to be 3 mm or less. Conclusions: MRI guidance for accelerated partial breast irradiation with the patient in the prone position with adequate contrast, spatial fidelity, and resolution is possible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Concurrent Chemoradiotherapy Followed by Consolidation Chemotherapy With Bi-Weekly Docetaxel and Carboplatin for Stage III Unresectable, Non-Small-Cell Lung Cancer: Clinical Application of a Protocol Used in a Previous Phase II Study

Purpose: To assess the clinical applicability of a protocol evaluated in a previously reported phase II study of concurrent chemoradiotherapy followed by consolidation chemotherapy with bi-weekly docetaxel and carboplatin in patients with stage III, unresectable, non-small-cell lung cancer (NSCLC). Methods and Materials: Between January 2000 and March 2006, 116 previously untreated patients with histologically proven, stage III NSCLC were treated with concurrent chemoradiotherapy. Radiation therapy was administered in 2-Gy daily fractions to a total dose of 60 Gy in combination with docetaxel, 30 mg/m{sup 2}, and carboplatin at an area under the curve value of 3 every 2 weeks during and after radiation therapy. Results: The median survival time for the entire group was 25.5 months. The actuarial 2-year and 5-year overall survival rates were 53% and 31%, respectively. The 3-year cause-specific survival rate was 60% in patients with stage IIIA disease, whereas it was 35% in patients with stage IIIB disease (p = 0.007). The actuarial 2-year and 5-year local control rates were 62% and 55%, respectively. Acute hematologic toxicities of Grade {>=}3 severity were observed in 20.7% of patients, while radiation pneumonitis and esophagitis of Grade {>=}3 severity were observed in 2.6% and 1.7% of patients, respectively. Conclusions: The feasibility of the protocol used in the previous phase II study was reconfirmed in this series, and excellent treatment results were achieved.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Implementation of an Online Adaptive Plan-of-the-Day Protocol for Nonrigid Motion Management in Locally Advanced Cervical Cancer IMRT

Purpose: To evaluate the clinical implementation of an online adaptive plan-of-the-day protocol for nonrigid target motion management in locally advanced cervical cancer intensity modulated radiation therapy (IMRT). Methods and Materials: Each of the 64 patients had four markers implanted in the vaginal fornix to verify the position of the cervix during treatment. Full and empty bladder computed tomography (CT) scans were acquired prior to treatment to build a bladder volume-dependent cervix-uterus motion model for establishment of the plan library. In the first phase of clinical implementation, the library consisted of one IMRT plan based on a single model-predicted internal target volume (mpITV), covering the target for the whole pretreatment observed bladder volume range, and a 3D conformal radiation therapy (3DCRT) motion-robust backup plan based on the same mpITV. The planning target volume (PTV) combined the ITV and nodal clinical target volume (CTV), expanded with a 1-cm margin. In the second phase, for patients showing >2.5-cm bladder-induced cervix-uterus motion during planning, two IMRT plans were constructed, based on mpITVs for empty-to-half-full and half-full-to-full bladder. In both phases, a daily cone beam CT (CBCT) scan was acquired to first position the patient based on bony anatomy and nodal targets and then select the appropriate plan. Daily post-treatment CBCT was used to verify plan selection. Results: Twenty-four and 40 patients were included in the first and second phase, respectively. In the second phase, 11 patients had two IMRT plans. Overall, an IMRT plan was used in 82.4% of fractions. The main reasons for selecting the motion-robust backup plan were uterus outside the PTV (27.5%) and markers outside their margin (21.3%). In patients with two IMRT plans, the half-full-to-full bladder plan was selected on average in 45% of the first 12 fractions, which was reduced to 35% in the last treatment fractions. Conclusions: The implemented online adaptive plan-of-the-day protocol for locally advanced cervical cancer enables (almost) daily tissue-sparing IMRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A new protocol to accurately determine microtubule lattice seam location

Microtubules (MTs) are cylindrical polymers of αβ-tubulin that display pseudo-helical symmetry due to the presence of a lattice seam of heterologous lateral contacts. The structural similarity between α- and β-tubulin makes it difficult to computationally distinguish them in the noisy cryo-EM images, unless a marker protein for the tubulin dimer, such as kinesin motor domain, is present. We have developed a new data processing protocol that can accurately determine αβ-tubulin register and seam location for MT segments. Our strategy can handle difficult situations, where the marker protein is relatively small or the decoration of marker protein is sparse. Using this new seam-search protocol, combined with movie processing for data from a direct electron detection camera, we were able to determine the cryo-EM structures of MT at 3.5. Å resolution in different functional states. The successful distinction of α- and β-tubulin allowed us to visualize the nucleotide state at the E-site and the configuration of lateral contacts at the seam.

59 BASIC BIOLOGICAL SCIENCES↗

A general protocol to coat titania shell on carbon-based composite cores using carbon as coupling agent

We present herein a general protocol to coat titania shell on carbon-based composite cores via the hydrolysis of titanium tetrabutoxide in a mixed solvent with the catalysis of ammonia. As coupling agent, their carbonaceous component can adsorb counter-charged NH{sub 4}{sup +}, and then the negatively charged ident toTiO{sup -} species are adsorbed via electrostatic interaction to form TiO{sub 2} shell. Various carbon-based cores with different functional components, such as Ag/C core/shell spheres, Ag/C nanocables, as well as magnetic (C-Fe{sub 3}O{sub 4}) hollow spheres can be coated with titania shell to form corresponding core/shell composites. Their optical or magnetic property is also investigated. Finally, anatase-phase titania shell with rough surface can be generated via hydrothermal treatment of aforementioned titania coated composites, which can further introduce the properties of anatase-phase titania to the composites. - Graphical abstract: A general protocol was developed to coat titania shell on carbon-based composite cores based on the carbonaceous surface. Typically, Ag/C/TiO{sub 2} core/shell spheres were formed via this method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Protocol for assembling and operating bipolar membrane water electrolyzers

Renewable energy-driven bipolar membrane water electrolyzers (BPMWEs) are a promising technology for sustainable production of hydrogen from seawater and other impure water sources. Here, we present a protocol for assembling BPMWEs and operating them in a range of water feedstocks, including ultra-pure deionized water and seawater. We describe steps for membrane electrode assembly preparation, electrolyzer assembly, and electrochemical evaluation. For complete details on the use and execution of this protocol, please refer to Marin et al. (2023).

Rios Amador, Isabela↗

X-ray Photoelectron Spectroscopy Analysis of Nafion-Containing Samples: Pitfalls, Protocols, and Perceptions of Physicochemical Properties

X-ray photoelectron spectroscopy (XPS) is one of the most common techniques used to analyze the surface composition of catalysts and support materials used in polymer electrolyte membrane (PEM) fuel cells and electrolyzers, providing important insights for further improvement of their properties. Characterization of catalyst layers (CLs) is more challenging, which can be at least partially attributed to the instability of ionomer materials such as Nafion during measurements. This work explores the stability of Nafion during XPS measurements, illuminating and addressing Nafion degradation concerns. The extent of Nafion damage as a function of XPS instrumentation, measurement conditions, and sample properties was evaluated across multiple instruments. Results revealed that significant Nafion damage to the ion-conducting sulfonic acid species (>50% loss in sulfur signal) may occur in a relatively short time frame (tens of minutes) depending on the exact nature of the sample and XPS instrument. This motivated the development and validation of a multipoint XPS data acquisition protocol that minimizes Nafion damage, resulting in reliable data acquisition by avoiding significant artifacts from Nafion instability. The developed protocol was then used to analyze both thin film ionomer samples and Pt/C-based CLs. Comparison of PEM fuel cell CLs to Nafion thin films revealed several changes in Nafion spectral features attributed to charge transfer due to interaction with conductive catalyst and support species. This study provides a method to reliably characterize ionomer-containing samples, facilitating fundamental studies of the catalyst-ionomer interface and more applied investigations of structure-processing-performance correlations in PEM fuel cell and electrolyzer CLs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Designing the Protocols for Programmable Ammonia Catalysis

Programmable catalysis can provide a more energy-efficient and cost-effective route to enhancing commercial ammonia production, a key process in the advancement of renewable energy technologies and the manufacture of fertilizers and basic chemicals. This work explores the computational discovery of optimal forcing protocols to drive such dynamic catalysis models. By employing matrix-free time-stepper methods, coupled with an optimization approach, that integrates Bayesian optimization with a Bayesian continuation strategy to efficiently discover the periodic steady states of such periodically forced systems, we enable the discovery of complex optimal catalyst strain waveforms, while ensuring robust solver convergence. We demonstrate the flexibility of our approach to discover optimized forcing protocols under varying physical constraints on strain modulation or other catalyst operating parameters. We show that these can have a temporal structure more complex than simple step functions. In order to detect undesirable catalytic loops that may correlate with overall reduced performance, we perform a study using graph-theoretical analysis to investigate the dynamics of catalytic kinetic networks formed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental Protocols for Studying Organic Non-aqueous Redox Flow Batteries

We report that Redox flow batteries (RFBs) are promising devices for grid-scale energy storage due to the decoupling of power and energy, which can be independently scaled by the electrode area and storage tank size, respectively. To date, only aqueous RFBs, such as the vanadium RFB, have been implemented commercially. Nevertheless, the limited energy densities and high-cost materials may preclude their wider market penetration. Organic non-aqueous redox-flow batteries (O-NRFBs), which utilize redox-active organic molecules (ROMs), have been offered as an attractive alternative. Many possible advantages include the use of earth-abundant elements (C, H, N, O, S, F), wherein the ROMs can be prepared from low-cost and sustainable materials. Additionally, a large variety of electroactive moieties are accessible as building blocks, providing a synthetic platform to tune the properties of ROMs through rational design. As a consequence, the development of novel ROMs has attracted researchers with diverse backgrounds, prompting remarkable innovations in the past decade. However, consistency in experimental protocols (e.g., electrochemical methods, cycling stability, experimental conditions) has not coincided with this uptick in research, leading to sometimes ambiguous and incomparable results. This is further convoluted by the complexity innate to battery development, such as cell design, detection, and characterization of reactions and active components. The O-NRFB application imposes stringent requirements on the physical or/and chemical processes involved in electrochemical cycling. Yet such considerations are often overlooked. Further, while quantum mechanical calculations provide a convenient tool for evaluating and selecting ROM candidates, this simulation is not always performed. Thus, in this Energy Focus, we detail a means to standardize experimental protocols for studies of O-NRFBs and suggest practices to facilitate fundamental understanding and development of ROMs.

25 ENERGY STORAGE↗

Development of the Basis for an Analytical Protocol for Feeds and Products of Bio-oil Hydrotreatment

Methods for easily following the main changes in the composition, stability, and acidity of bio-oil in hydrotreatment are presented. The correlation to more conventional methods is provided. Depending on the final use the upgrading requirement is different. This will create challenges also for the analytical protocol. Polar pyrolysis liquids and their products can be divided into five main groups with solvent fractionation the change in which is easy to follow. This method has over ten years been successfully used for comparison of fast pyrolysis bio-oil quality, and the changes during handling, and storage, provides the basis of the analytical protocol presented in this paper. The method has most recently been used also for characterisation of bio-oil hydrotreatment products. Discussion on the use of gas chromatographic and spectroscopic methods is provided. In addition, fuel oil analyses suitable for fast pyrolysis bio-oils and hydrotreatment products are discussed.

02 PETROLEUM↗

Direct Cellular Lysis/Protein Extraction Protocol for Soil Metaproteomics

We present a novel direct protocol for deep proteome characterization of microorganisms in soil. The method employs thermally assisted detergent-based cellular lysis (SDS) of soil samples, followed by TCA precipitation for proteome extraction/cleanup prior to liquid chromatography-mass spectrometric characterization. This approach was developed and optimized using different soils inoculated with genome-sequenced bacteria (Gram-negative Pseudomonas putida or Gram-positive Arthrobacter chlorophenolicus). Direct soil protein extraction was compared to protein extraction from cells isolated from the soil matrix prior to lysis (indirect method). Each approach resulted in identification of greater than 500 unique proteins, with a wide range in molecular mass and functional categories. To our knowledge, this SDS-TCA approach enables the deepest proteome characterizations of microbes in soil to date, without significant biases in protein size, localization, or functional category compared to pure cultures. This protocol should provide a powerful tool for ecological studies of soil microbial communities.

54 ENVIRONMENTAL SCIENCES↗

A bending test protocol for characterizing the mechanical performance of flexible photovoltaics

Flexible photovoltaics (PV) represents a promising research field with great potential for wearable, portable, and indoor applications. Significant progress has been made in recent years, with flexible emerging PV reporting power conversion efficiency (PCE) over 24%. Yet, there is a need for a unifying protocol to assess PV performance, compare research results, and evaluate the state- of-the-art achievements in flexible PV. In this paper, a consensus protocol is presented for measuring PCE over 1,000 bending cycles under 1% strain. Moreover, several good practice guidelines are proposed including bending procedures, flexibility testing with and without encapsulation, and ambient conditions during testing (e.g., temperature, humidity, illumination). Notably, the importance of uniform application of bending radius and the testing of parallel and perpendicular orientations of bending axis with respect to the direction of the electric current are emphasized. These recommendations aim to promote consistency in device comparison and allow for better reproducibility.

Fukuda, Kenjiro↗

Optimizing radiotherapy protocols using computer automata to model tumour cell death as a function of oxygen diffusion processes

The concept of hypofractionation is gaining momentum in radiation oncology centres, enabled by recent advances in radiotherapy apparatus. The gain of efficacy of this innovative treatment must be defined. We present a computer model based on translational murine data for in silico testing and optimization of various radiotherapy protocols with respect to tumour resistance and the microenvironment heterogeneity. This model combines automata approaches with image processing algorithms to simulate the cellular response of tumours exposed to ionizing radiation, modelling the alteration of oxygen permeabilization in blood vessels against repeated doses, and introducing mitotic catastrophe (as opposed to arbitrary delayed cell-death) as a means of modelling radiation-induced cell death. Published data describing cell death in vitro as well as tumour oxygenation in vivo are used to inform parameters. Our model is validated by comparing simulations to in vivo data obtained from the radiation treatment of mice transplanted with human prostate tumours. We then predict the efficacy of untested hypofractionation protocols, hypothesizing that tumour control can be optimized by adjusting daily radiation dosage as a function of the degree of hypoxia in the tumour environment. Further biological refinement of this tool will permit the rapid development of more sophisticated strategies for radiotherapy.

60 APPLIED LIFE SCIENCES↗