Search NASA⌕ Search

SEARCH · Search NASA

Results for “proximity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Geothermal Play-Fairway Analysis of Washington State Prospects: Final Report

The Washington State Geothermal Play-Fairway Analysis overcomes the exploration challenges posed by dense vegetation, glacial deposits, and extreme precipitation. The geothermal play-fairways we target are locations where heat, permeability, and saturated porosity are present in sufficient volume to provide adequate heat exchange at depths accessible by modern drilling technology. The three study areas lie along the Cascade Range magmatic arc and are near Mount Baker, Mount St. Helens, and the Wind River Valley. The seven-year project is divided into three phases. In Phase 1 we build on a previous statewide assessment of geothermal resources and develop an initial modeling approach. The results are a series of favorability, uncertainty, and risk maps for three targeted study areas. Based on these initial results, we collect new geologic and geophysical data to further refine our modeling and reduce exploration uncertainty in Phase 2. We improve the modeling method to handle the new data and update the favorability, uncertainty, and risk maps. We also update the conceptual geothermal resource models. In Phase 3 we validate our modeling approach by drilling two temperature-gradient holes and collecting and analyzing core, image logs, and new geochemistry. Our modeling approach improves on an earlier statewide method through a more-rigorous and detailed assessment of heat and permeability. Permeability potential is assessed through geomechanical modeling of the deformation that can generate and maintain reservoir porosity and permeability. Metrics to inform heat potential include temperature-gradient wells, which are sparse in Washington; proximity of Quaternary volcanic vents and young intrusive rock; spring temperature; and reservoir temperature inferred from geothermometry. We weight the individual components using an expert-guided approach known as the Analytical Hierarchy Process. During Phase 2 we also develop a fluid-filled fracture model, and an infrastructure model that helps to delineate areas which are more favorable for geothermal development based on proximity to transmission lines, elevation, land ownership and use restrictions, and availability of process water. New geologic and geophysical data is collected during Phase 2 in each of our three main study areas. At Mount Baker and north of Mount St. Helens we conduct 1:24,000-scale geologic mapping and lidar analysis to better constrain the location and character of surface faults; detailed mapping in the Wind River Valley was completed just prior to the start of this project. Ages of intrusive rocks are determined with 40 Ar/ 39 Ar geochronology, though all of our samples are Miocene or older. We collect ground based gravity observations (a total of 1,580 new stations) in all of our study areas and ground-based magnetic lines (a total of 93 km) at Mount Baker. These data are combined with existing gravity and aeromagnetic data and used to constrain fault locations and geometry. Two to three cross sections are constructed at each study area using the mapped surface geology and forward-modeling of the gravity and magnetic data; these cross sections form the basis for our updated conceptual models. We collect magnetotelluric surveys at Mount Baker and Mount St. Helens and these data are inverted to form a resistivity model from the surface to about 10 km depth; each model shows conductive zones that can be interpreted as upwelling geothermal fluids. At Mount St. Helens we deploy a passive seismic array and use the newly detected events to refine the location of the Saint Helens seismic zone. We also employ ambient-noise tomography to develop a detailed seismic-velocity model for the study area and use this model to help constrain our cross sections and conceptual model. Based on the new data collected during Phase 2—and our updated models—we develop a campaign of temperature-gradient holes and core analysis to validate our modeling in Phase 3. Drill hole MB76-31 is located near Little Park Creek, 11 km west-southwest of the summit of Mount Baker, and is 1,471 ft deep. About 410 ft of core from the lower portion of the hole—and image logs from ~175 ft below ground surface to the bottom—are collected and analyzed. Water samples are collected and processed for geothermometry. Drill hole MSH17-24 is located along upper Schultz Creek, 16 km north-northeast of Mount St. Helens and has core from 470 ft to the bottom at 1,053 ft. We did not collect image logs due to borehole stability concerns, but water samples are collected and analyzed for geothermometry. Repeat temperature-gradient measurements are made at both sites and thermal conductivity is measured from core samples. At MB76-31, the equilibrated temperature gradient of 64°C/km and calculated heat flow of 141–159 mW/m 2 is more than twice the regional average. Detailed mapping and analysis of the core, coupled with correlation to the image logs, indicates a history of permeability generation consistent with our predictions of high permeability. Because the site has high favorability in the Phase 2 model, we consider the results a positive validation of the modeling. At site MSH17-24, the equilibrated temperature gradient of ~15°C/km and calculated heat flow of 41–43 mW/m 2 are similar to regional. Geochemical analysis of the water samples indicates a meteoric source without any geothermal component. Detailed outcrop-based mapping of fault exposures near the drill site and analysis of image logs from nearby boreholes indicates a history of permeability generation consistent with our predictions. Because the site has low favorability in the Phase 2 model, we consider the results a positive validation of the modeling. Together, the two sites provide a reasonably positive validation of the Phase 2 modeling and should encourage future use of this modeling approach.

15 GEOTHERMAL ENERGY↗

Spin Effects in Low Dimensional Correlated Systems (Final Technical Report)

Our program focuses on the behavior of two-dimensional superconducting systems that have been placed in high magnetic fields and/or in contact with magnetic materials. Our specific research agenda is organized into two separate but related areas. The first is a study of disorder and correlation effects in extremely thin superconducting aluminum, beryllium, and rhenium films that have been subjected to very high magnetic fields. We are particularly interested in understanding how the coupling between the applied field and the electron spins affects the system’s ability to form superconducting state. We now have good evidence that as the electron spins in these superconductors attempt to align to the magnetic field, a new superconducting phase emerges near the critical field transition and that this phase has a significant influence on the character of the transition. Thus, the spin behavior near the transition is much more complex than expected. The second class of systems is proximity structures comprised of superconducting/ferromagnetic (SC/FM) and superconducting/heavy metal (SC/HM) bilayers. We have developed spin-resolved tunneling probes that give us a direct measure of the proximity-induced exchange field in the SC/FM structures, as well as the spin-orbit scattering rate in SC/HM structures. Recently we have demonstrated that the magnitude of the exchange field can be modulated with an external gate, thereby producing a magneto-electric response in the bilayers. We plan to optimize this magneto-electric effect by getting a better understanding of the microscopic mechanism of the interface-induce exchange field, as well as improving the gate barriers and/or the bilayer interface quality. The ultimate goal is to develop a device such as a voltage-controlled superconducting switch or a spin- polarized electron source with a voltage-tunable Zeeman splitting.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Idaho National Laboratory Integrated Multisite SSHAC Level 3: Probabilistic Volcanic Hazards Assessment

The Idaho National Laboratory (INL) resides on the eastern Snake River Plain (ESRP), part of the Snake River Plain (SRP) with a complex origin and geologic history of volcanism. Much of the Quaternary (last 2.58 million years) volcanism within 400 km of INL is genetically associated with a major thermal anomaly referred to as the Yellowstone hotspot, which is currently located more than 180 km northeast of INL. Near INL, local volcanic sources include silicic domes near its southern border, and numerous dike-fed basaltic vents of the ESRP, some of which are near or within the INL boundaries. Quantitative probabilistic assessments of screened-in volcanic hazardous phenomena for nine different facility complexes at the INL are presented for a Senior Seismic Hazard Analysis Committee (SSHAC) Level 3 (SL3) study. The comprehensive, integrated multisite SSHAC study consists of a single regional Probabilistic Volcanic Hazards Assessment (PVHA) that pertains to all nine INL facility complexes, with site-specific information developed at each respective area of interest (AOI), referred to as the "INL facility AOI" (Figure ES-1). Hazard products are generated for specified INL facility AOIs for use by multiple stakeholders from different agencies in risk-informed decision-making regarding site selection, operations, and design of nuclear facilities at INL, consistent with U.S. Department of Energy (DOE) and U.S. Nuclear Regulatory Commission (NRC) regulatory guidance. The study also serves as the basis for future periodic safety assessments required for existing DOE facilities, such as 10-year evaluations of natural-phenomena hazards. Elements of the INL PVHA including initial characterization, screening, quantitative assessments of eruption and hazard potential, and consideration of facility needs are conducted using the three phases of the SSHAC process: evaluation, integration, and documentation. As per regulatory guidance, the SSHAC framework provided the necessary processes and procedures for the PVHA Technical Integration (TI) team, at three workshops, five formal working meetings and many TI team remote meetings, to conduct initial characterization, screen the volcanic hazards, create PVHA model inputs, exercise those models in the PVHA, consider facility-specific volcanic hazard needs, and perform final hazard calculations. The Participatory Peer Review Panel (PPRP) provided independent oversight and performed process and technical reviews of the PVHA throughout its duration. The study included an extensive New Data Collection and Analyses (NDCA) program developed by the PVHA TI team to reduce uncertainties in hazard-significant elements in the PVHA model. NDCA activities generated 20 reports providing important contributory datasets and results to the project database for characterizing the ESRP. For example, a report compiling the dimensions of ESRP shield volcanoes and lava fields was used to construct volcanic footprints (areas of impact), was compared with data from INL subsurface cores, and was used to validate the results of lava-flow inundation modeling on the contemporary terrain. Another example is the acquisition of aeromagnetic data over INL and its surrounding area, with maps of buried magmatic features (e.g., subsurface volcanoes and swarms of feeder dikes) that informed the PVHA conceptual model of volcanism. The SSHAC evaluation process was used to conduct all elements of the PVHA including initial characterization and screening. Existing data and NDCA activities provided the foundation to develop the tectonomagmatic conceptual model of volcanism for the region of geographical interest in the SRP and Yellowstone hotspot volcanic system, and for considering volcanoes in the western US. Considering Quaternary volcanic sources active during this period, the screening approach identified and evaluated magma compositions, types of eruptive and intrusive phenomena, types of hazardous phenomena, and proximity of sources to INL. The PVHA TI team evaluated 18 types of magmatic sources in terms of 20 potentially hazardous phenomena, resulting in 360 screening decisions. The screening process resulted in 140 screened-in hazardous volcanic phenomena for Quaternary volcanic sources 1) proximal to INL facility complexes in the ESRP (64 basaltic and 54 silicic), 2) regional sources associated with the Yellowstone caldera system and Blackfoot Reservoir volcanic field (7), and 3) more distal sources from thirteen Cascade volcanoes and two volcanoes at Long Valley caldera (CA).

58 GEOSCIENCES↗

Preliminary Analysis of Nuclear-Powered Data Center Scenarios

This report provides a comprehensive analysis of the potential for nuclear energy to meet the growing energy demands of data centers (DCs). It evaluates the technical, economic, and socio-environmental implications of coupling Nuclear Power Plants (NPPs) with DCs, providing initial responses to several key research questions: What is the potential increased energy demand from DCs in the U.S., in the short, medium and long term? The U.S. is experiencing a rapid increase in energy demand from DCs, with projections indicating a total increase of 24-74 GWy(e) by 2028. Meeting this demand with nuclear energy would require 27–85 GWe of installed capacity. While this surge is expected to slow in the long term, the DC industry needs reliable, scalable, and clean energy sources. How much nuclear capacity can be deployed to meet DC demand and in which timeframe? Several pathways for increasing nuclear capacity were identified, including uprates, restarts of recently retired reactors, power purchase agreements with existing fleet, and new construction. Approximately 20‒28 GWe of nuclear capacity could be dedicated to DCs by the early 2030s. How much High Assay Low Enriched Uranium (HALEU) would be needed to support some nuclear deployment scenarios for DCs? Meeting the deployment targets announced by Google and Amazon for the Kairos Power Fluoride-Salt-Cooled High-Temperature Reactor or KP-FHR (~500 MWe by 2035) and the Xe-100 (~1 GWe by 2040), respectively, requires ramping up 19.75% enriched HALEU production to ~6 t/yr by 2040. What types of nuclear energy/DC coupling options exist, and what are the different benefits/challenges? Five coupling options were analyzed, ranging from grid-connected configurations to colocated, behind-the-meter setups. Key design considerations include the proximity to high- and/or medium-voltage transmission lines, the desired internal fault tolerance, and the sources of alternative/backup power during outages. Each coupling option offers unique benefits and challenges in terms of reliability, system costs, regulation, timeline, etc. A list of NPP/DC deployment scenarios was developed, considering existing or newly built NPP or DC projects. Colocated DCs with new small modular reactors or large reactors on greenfield and brownfield sites are the focus of this report. What types of reactors, especially what size, may be incentivized by DCs? Reactor sizing optimization revealed that the ideal reactor size and number of units depend on DC demand, coupling configurations defined in this report, and other economic factors. Larger reactors are preferred for high-demand DCs and grid-connected systems, while larger number of smaller reactors are better suited for DC configurations without grid backup. Which sites may be compatible with co-located nuclear-powered DCs? Siting those projects is a complicated evaluation factoring local water resources, grid connection availability and reliability, IT infrastructure, local work force, proximity to population zones, etc. For this effort greenfield and brownfield sites such as retired coal-fired plants were used to evaluate this question. This evaluation is not meant to recommend any particular site but it highlights key siting criteria and demonstrates large-scale site availability. What are the socio-economic impacts of co-located nuclear-powered DCs? Those projects generate substantial economic benefits to the local economy, particularly in urban settings. Hyperscale DCs colocated with nuclear power plants (sized around 1 GW of power) can create nearly 1,700 jobs for annual operations and more than 7,300 jobs among the supply chain and local businesses as a result of increased household spending. Rural projects also provide significant benefits, but at lower magnitudes compared to urban deployments.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

CLEAP Project: OR-SAGE Analysis for MT, UT, and CO States

The OR-SAGE tool is designed to use industry-accepted practices in screening sites and then employ the proper array of data sources through the considerable computational capabilities of GIS technology available at ORNL. The tool was developed to screen the potential for NPP siting on a national and regional basis. However, because of the tool granularity, it is often focused specifically on the immediate area around user sites of interest. If data center siting parameters can be added to OR-SAGE, the ability to evaluate data center siting on a localized scale will be beneficial.1 More than 60 data sets have been collected and processed by ORNL to develop exclusionary, avoidance, and suitability criteria for screening sites for a variety of power generation types, including nuclear power plants. Available site evaluation parameters include population density, slope, seismic activity, proximity to cooling-water sources, proximity to hazard facilities, avoidance of protected lands and floodplains, susceptibility to landslide hazards, and many others. All siting parameters should be considered as flags to inform siting decisions and should not be used to rule in or rule out any NPP site. Once data center siting parameters are identified, appropriate data sets will be collected and processed. The OR-SAGE process is very versatile. Essentially, OR-SAGE is a visual, relational database. The database partitions the contiguous United States, a total of 720 million hectares (~1.8 billion acres), into 100-m by 100-m (1 hectare or ~2.5 acre) cells. The database is tracking just under 700 million individual land cells. Successive suitability criterion is applied to each cell in the database. User-specified thresholds can be applied to each siting parameter data layer. In this manner, a variety of scenarios can be quickly and thoroughly evaluated. Data can be added and/or revised within OR-SAGE to address user interests. Siting security assessment capability is currently being added to OR-SAGE. Security is expected to be of concern at data centers whether it is collocated with a nuclear power generating technology or not. If data center is collocated with a nuclear power generating source, the security threat attractiveness level of both will likely increase. It will be of additional benefit if a potential data center site is also assessed for security vulnerability.

97 MATHEMATICS AND COMPUTING↗

An expanded role for the transcription factor WRINKLED1 in the biosynthesis of triacylglycerols during seed development

The transcription factor WRINKLED1 ( WRI1 ) is known as a master regulator of fatty acid synthesis in developing oilseeds of Arabidopsis thaliana and other species. WRI1 is known to directly stimulate the expression of many fatty acid biosynthetic enzymes and a few targets in the lower part of the glycolytic pathway. However, it remains unclear to what extent and how the conversion of sugars into fatty acid biosynthetic precursors is controlled by WRI 1. To shortlist possible gene targets for future in-planta experimental validation, here we present a strategy that combines phylogenetic foot printing of cis-regulatory elements with additional layers of evidence. Upstream regions of protein-encoding genes in A. thaliana were searched for the previously described DNA-binding consensus for WRI1, the ASML1/WRI1 (AW)-box. For about 900 genes, AW-box sites were found to be conserved across orthologous upstream regions in 11 related species of the crucifer family. For 145 select potential target genes identified this way, affinity of upstream AW-box sequences to WRI1 was assayed by Microscale Thermophoresis. This allowed definition of a refined WRI1 DNA-binding consensus. We find that known WRI1 gene targets are predictable with good confidence when upstream AW-sites are phylogenetically conserved, specifically binding WRI1 in the in vitro assay, positioned in proximity to the transcriptional start site, and if the gene is co-expressed with WRI1 during seed development. When targets predicted in this way are mapped to central metabolism, a conserved regulatory blueprint emerges that infers concerted control of contiguous pathway sections in glycolysis and fatty acid biosynthesis by WRI1. Several of the newly predicted targets are in the upper glycolysis pathway and the pentose phosphate pathway. Of these, plastidic isoforms of fructokinase ( FRK 3) and of phosphoglucose isomerase ( PGI 1) are particularly corroborated by previously reported seed phenotypes of respective null mutations.

59 BASIC BIOLOGICAL SCIENCES↗

Structures of HIV-1 Neutralizing Antibody 10E8 Delineate the Mechanistic Basis of Its Multi-Peak Behavior on Size-Exclusion Chromatography

Antibody 10E8 is capable of effectively neutralizing HIV through its recognition of the membrane-proximal external region (MPER), and a suitably optimized version of 10E8 might have utility in HIV therapy and prophylaxis. However, 10E8 displays a three-peak profile on size-exclusion chromatography (SEC), complicating its manufacture. Here we show cis-trans conformational isomerization of the Tyr-Pro-Pro (YPP) motif in the heavy chain 3rd complementarity-determining region (CDR H3) of antibody 10E8 to be the mechanistic basis of its multipeak behavior. We observed 10E8 to undergo slow conformational isomerization and delineate a mechanistic explanation for effective comodifiers that were able to resolve its SEC heterogeneity and to allow an evaluation of the critical quality attribute of aggregation. We determined crystal structures of single and double alanine mutants of a key di-proline motif and of a light chain variant, revealing alternative conformations of the CDR H3. We also replicated both multi-peak and delayed SEC behavior with MPER-antibodies 4E10 and VRC42, by introducing a Tyr-Pro (YP) motif into their CDR H3s. Our results show how a conformationally dynamic CDR H3 can provide the requisite structural plasticity needed for a highly hydrophobic paratope to recognize its membrane-proximal epitope.

60 APPLIED LIFE SCIENCES↗

Integration of Air Classification and Hydrothermal Carbonization to Enhance Energy Recovery of Corn Stover

Air classification (AC) is a cost-effective technology that separates the energy-dense light ash fraction (LAF) from the inorganic-rich high ash fraction (HAF) of corn stover. HAF could be upgraded into energy-dense solid fuel by hydrothermal carbonization (HTC). However, HTC is a high-temperature, high-pressure process, which requires additional energy to operate. In this study, three different scenarios (i.e., AC only, HTC only, and integrated AC–HTC) were investigated for the energy recovery of corn stover. AC was performed on corn stover at an 8 Hz fan speed, which yielded 84.4 wt. % LAF, 12.8 wt. % HAF, and 2.8 wt. % below screen particles. About 27 wt. % ash was reduced from LAF by the AC process. Furthermore, HTC was performed on raw corn stover and the HAF of corn stover at 200, 230, and 260 °C for 30 min. To evaluate energy recovery, solid products were characterized in terms of mass yield, ash yield, ultimate analysis, proximate analyses, and higher heating value (HHV). The results showed that the energy density was increased with the increase in HTC temperature, meanwhile the mass yield and ash yield were decreased with the increase in HTC temperature. Proximate analysis showed that fixed carbon increased 18 wt. % for original char and 27 wt. % for HAF char at 260 °C, compared to their respective feedstocks. Finally, the hydrochar resulting from HAF was mixed with LAF and pelletized at 180 bar and 90 °C to densify the energy content. An energy balance of the integrated AC–HTC process was performed, and the results shows that integrated AC with HTC performed at 230 °C resulted in an additional 800 MJ/ton of energy recovery compared to the AC-only scenario.

09 BIOMASS FUELS↗

Saprotrophic Fungus Induces Microscale Mineral Weathering to Source Potassium in a Carbon-Limited Environment

Plants rely on potassium for many critical biological processes, but most soils are potassium limited. Moving potassium from the inaccessible, mineral-bound pool to a more bioavailable form is crucial for sustainably increasing local potassium concentrations for plant growth and health. Here, we use a synthetic soil habitat (mineral doped micromodels) to study and directly visualize how the saprotrophic fungus, Fusarium sp. DS 682, weathers K-rich soil minerals. After 30 days of fungal growth, both montmorillonite and illite (secondary clays) had formed as surface coatings on primary K-feldspar, biotite, and kaolinite grains. The distribution of montmorillonite differed depending on the proximity to a carbon source, where montmorillonite was found to be associated with K-feldspar closer to the carbon (C) source, which the fungus was inoculated on, but associated with biotite at greater distances from the C source. The distribution of secondary clays is likely due to a change in the type of fungal exuded organic acids; from citric to tartaric acid dominated production with increasing distance from the C source. Thus, the main control on the ability of Fusarium sp. DS 682 to weather K-feldspar is proximity to a C source to produce citric acid via the TCA cycle.

54 ENVIRONMENTAL SCIENCES↗

Investigating the Influence of River Geomorphology on Human Presence Using Night Light Data: A Case Study in the Indus Basin

Human settlements have historically thrived near rivers due to enhanced navigation and trade, and the availability of water supply and resources. The use of night light data, representing economic activities, provides a novel approach to studying the interactions between human activity and rivers over time. Here, we use the Defense Meteorological Satellite Program (DMSP) stable night light data from 2000 to 2013 as a proxy for human presence and activities to quantify the statistical relationships between night light presence and intensity in the Indus Basin, Asia. We test how these data are affected by proximity to trunk channels and by channel type (single/multi-thread) in the study area. We find that night light presence is enhanced by 26% within a 0 to 5 km proximity range of the Indus River and its tributaries, relative to the basin as a whole. We interpret this to represent increased human presence and activity within this zone. However, the mean intensity is lower near the river and higher away from the river, signifying denser settlements, such as towns and cities, which are preferentially located away from the Indus and its tributaries. Moreover, the enhancement of lit pixels signifying human presence and activities is increased by 18% near single-thread sections of the Indus River, compared to segments of the Indus displaying multi-thread morphologies. We suggest that this is due to the enhanced stability of single-threaded channels, relative to mobile multi-threaded channel reaches. This study demonstrates how night lights are an important tool in studying the relationship between human presence and river dynamics in large catchments such as the Indus, and we suggest that these data will have an important role in assessing differential flood spatial and social vulnerability at a regional scale.

Environmental Sciences & Ecology↗

Measuring the Density Fields around Bright Quasars at z ~ 6 with XQR-30 Spectra

Measuring the density of the intergalactic medium using quasar sight lines in the epoch of reionization is challenging due to the saturation of Ly α absorption. Near a luminous quasar, however, the enhanced radiation creates a proximity zone observable in the quasar spectra where the Ly α absorption is not saturated. In this study, we use 10 high-resolution ( R ≳ 10,000) z ~ 6 quasar spectra from the extended XQR-30 sample to measure the density field in the quasar proximity zones. We find a variety of environments within 3 pMpc distance from the quasars. We compare the observed density cumulative distribution function (CDF) with models from the Cosmic Reionization on Computers simulation and find a good agreement between 1.5 and 3 pMpc from the quasar. This region is far away from the quasar hosts and hence approaching the mean density of the universe, which allows us to use the CDF to set constraints on the cosmological parameter σ 8 = 0.6 ± 0.3. The uncertainty is mainly due to the limited number of high-quality quasar sight lines currently available. Utilizing the more than 200 known quasars at z ≳ 6, this method will allow us to tighten the constraint on σ 8 to the percent level in the future. In the region closer to the quasar within 1.5 pMpc, we find that the density is higher than predicted in the simulation by 1.23 ± 0.17, suggesting that the typical host dark matter halo mass of a bright quasar ( M 1450 < -26.5) at z ~ 6 is .

79 ASTRONOMY AND ASTROPHYSICS↗

IM3 Projected US Data Center Locations

IM3 Projected US Data Center Locations This dataset contains model projections of new data center facilities in the contiguous United States (CONUS) through 2035 using the CERF – Data Centers model. Data center locations are modeled across four data center electricity demand growth scenarios (low, moderate, high, higher) and five market gravity scenarios (0%, 25%, 50%, 75%, 100%). Projected locations are intended to be regional representations of feasible siting locations in the future to assess potential grid and water stress impacts. The data center load growth scenarios correspond with the rates outlined in EPRI (2024) and include 3.71%, 5%, 10%, and 15% annual growth of electricity demand for data centers from 2023 values in 37 states across the CONUS. Market gravity scenarios correspond to the relative importance of proximity to data center markets or high population areas compared to locational cost in the siting algorithm. 0% market gravity means that siting decisions were entirely determined by the locational cost in each feasible location. 100% market gravity means that only market proximity was considered when siting. Other scenarios have weight placed on both components where total weight always equals 100%. Locational cost is dependent on facility cooling type and corresponding electricity cost, taxes, and other factors. Facility cooling type is spatially determined where high water stress and/or areas with high summer wet bulb temperatures are assumed to operate with mechanical cooling for a higher fraction of the year rather than evaporative cooling. Feasible data center siting areas are based on geospatial suitability raster data developed with open-source information. The following areas are excluded from siting: Areas within 300 m of a federal airport runway Waterbodies Areas with slope >16% Areas susceptible to sinkholes High coastal or inland flood risk areas Local, state, and federal parks, leisure areas, and cemeteries Areas >2 km away from electric substations Areas >5 km away from a municipal water supplier service area Areas >2 km away from high-speed fiber provider service territory Protected Areas Database of the United States (PAD-US) areas Railroads, major roadways, and minor roadways Military areas and training grounds NLCD developed lands Areas >0.8 km (0.5 miles) from NLCD developed lands Because we use open-source information, proprietary information that can influence siting decisions such as individual tax agreements with cities, detailed fiber line connectivity, electric grid power capacity agreements, and others, are not currently accounted for in the modeling process. Using specific building locations and footprints in the dataset for local planning purposes is not advised. Technical Information Geospatial data is provided in geojson format using the Albers Equal Area Conic (ESRI:102003) coordinate reference system. The datasets contain the following parameters: id - unique identification number within given scenario file growth_scenario – data center demand growth scenario market_gravity_weight – market gravity weight scenario (%) region – name of region (i.e., US State) total_cost_million_usd – locational siting cost ($million) campus_size_square_ft – total land acquired for data center facility (square ft) data_center_it_power_mw – IT power of data center facility (MW) mechanical_cooling_frac – fraction of year when data center uses mechanical cooling system water_cooling_frac– fraction of year when data center uses evaporative cooling system cooling_energy_demand_mwh – total annual facility energy demand for cooling (MWh) cooling_water_demand_mgy – total annual facility water demand for cooling (MG) cooling_water_consumption_mgy – total annual facility water consumed (MG) normalized_locational_cost – normalized total locational cost score for location normalized_gravity_score – normalized market gravity score for location weighted_siting_score – total weighted siting score of locational cost and gravity score geometry – polygon geometry of facility Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. License This data is made available under a CCBY4.0 License Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830

Mongird, Kendall (ORCID:0000000328077088)↗

IM3 Projected US Data Center Locations

IM3 Projected US Data Center Locations This dataset contains model projections of new data center facilities in the contiguous United States (CONUS) through 2035 using the CERF – Data Centers model. Data center locations are modeled across four data center electricity demand growth scenarios (low, moderate, high, higher) and five market gravity scenarios (0%, 25%, 50%, 75%, 100%). Projected locations are intended to be regional representations of feasible siting locations in the future to assess potential grid and water stress impacts. The data center load growth scenarios correspond with the rates outlined in EPRI (2024) and include 3.71%, 5%, 10%, and 15% annual growth of electricity demand for data centers from 2023 values in 37 states across the CONUS. Market gravity scenarios correspond to the relative importance of proximity to data center markets or high population areas compared to locational cost in the siting algorithm. 0% market gravity means that siting decisions were entirely determined by the locational cost in each feasible location. 100% market gravity means that only market proximity was considered when siting. Other scenarios have weight placed on both components where total weight always equals 100%. Locational cost is dependent on facility cooling type and corresponding electricity cost, taxes, and other factors. Facility cooling type is spatially determined where high water stress and/or areas with high summer wet bulb temperatures are assumed to operate with mechanical cooling for a higher fraction of the year rather than evaporative cooling. Feasible data center siting areas are based on geospatial suitability raster data developed with open-source information. The following areas are excluded from siting: Areas within 300 m of a federal airport runway or within an airport area boundary Waterbodies Areas with slope >16% Areas susceptible to sinkholes High coastal or inland flood risk areas Local, state, and federal parks, leisure areas, and cemeteries Areas >2 km away from electric substations Areas >5 km away from a municipal water supplier service area Areas >2 km away from high-speed fiber provider service territory USGS Protected Areas Database of the United States (PAD-US) GAP status 1, 2, or 3 areas US National Parks Wetlands USFWS critical habitats BIA land areas Railroads, major roadways, and minor roadways Military areas and training grounds NLCD developed lands Areas >0.8 km (0.5 miles) from NLCD developed lands Because we use open-source information, proprietary information that can influence siting decisions such as individual tax agreements with cities, detailed fiber line connectivity, electric grid power capacity agreements, and others, are not currently accounted for in the modeling process. Using specific building locations and footprints in the dataset for local planning purposes is not advised. Technical Information Geospatial data is provided in geojson format using the Albers Equal Area Conic (ESRI:102003) coordinate reference system. The datasets contain the following parameters: id - unique identification number within given scenario file growth_scenario – data center demand growth scenario market_gravity_weight – market gravity weight scenario (%) region – name of region (i.e., US State) total_cost_million_usd – locational siting cost ($million) campus_size_square_ft – total land acquired for data center facility (square ft) data_center_it_power_mw – IT power of data center facility (MW) mechanical_cooling_frac – fraction of year when data center uses mechanical cooling system water_cooling_frac– fraction of year when data center uses evaporative cooling system cooling_energy_demand_mwh – total annual facility energy demand for cooling (MWh) cooling_water_demand_mgy – total annual facility water demand for cooling (MG) cooling_water_consumption_mgy – total annual facility water consumed (MG) normalized_locational_cost – normalized total locational cost score for location normalized_gravity_score – normalized market gravity score for location weighted_siting_score – total weighted siting score of locational cost and gravity score geometry – polygon geometry of facility Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. License This data is made available under a CCBY4.0 License Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830

Mongird, Kendall (ORCID:0000000328077088)↗

An effective survey method for studying volant species activity and behavior at tall structures

The effects of anthropogenic modification of air space on wildlife, particularly volant species, is not fully understood. Thus, it is essential to understand wildlife-interactions with tall structures to implement effective mitigation strategies. Yet, we are currently lacking standard protocols for visual surveys of wildlife behavior at such heights. Our study sought to determine an effective, repeatable method using readily available night vision and thermal technology to survey wildlife at tall structures. Using bats as the taxonomic group of interest, we (1) created a key to identify bats and their behavior, (2) compared the effectiveness of 2 different technologies, and (3) assessed optimal equipment placement to visually capture bat activity and behavior in proximity to wind turbine towers. For the latter, we tested thermal cameras at four distances from the base of the tower. The results of our study revealed that thermal cameras captured ∼34% more flying animals than night vision at a 2 m distance. However, due to the heat signature of the turbine towers themselves, it was challenging to identify behaviors and interactions that occurred in close proximity to the towers. In contrast, it was difficult to identify bats approaching the towers using night vision, yet we were able to clearly observe interactions with the towers themselves. With regards to equipment placement, we visually captured more bats with the thermal cameras placed 2 m from the tower base compared to farther distances. From our findings, we recommend that when using either thermal or night vision technology at tall structures, they be placed 2 m from the base to effectively observe interactions along the length of these structures. In addition, we further recommend that consideration be given to the use of these two technology types together to effectively conduct such surveys. If these survey techniques are incorporated into standard protocols, future surveys at a variety of tall structures are likely to become comparable and repeatable, thereby more effectively informing any mitigation strategies that may be required.

54 ENVIRONMENTAL SCIENCES↗

Electrostatic graphene speaker

This disclosure provides systems, methods, and apparatus associated with an electrostatically driven graphene speaker. In one aspect, a device includes a graphene membrane, a first frame on a first side of the graphene membrane, and a second frame on a second side of the graphene membrane. The first frame and the second frame both include substantially circular open regions that define a substantially circular portion of the graphene membrane. A first electrode is proximate the first side of the circular portion of the graphene membrane. A second electrode proximate the second side of the circular portion of the graphene membrane.

42 ENGINEERING↗

OLED with minimal plasmonic losses

A top-emitting organic light emitting device (OLED) that comprises: a substrate having an inward side and an outward side; an OLED body that includes a transparent bottom electrode proximate to the inward side of the substrate, an organic emitting layer, and a transparent top electrode in that order; a non-metallic, diffuse reflective layer with a roughened top surface proximate to and facing the bottom transparent electrode; and a high refractive index waveguide layer. The diffuse reflective layer is positioned between the inward side of the substrate and the OLED body, and the waveguide layer is positioned between the diffuse layer and the bottom transparent electrode.

42 ENGINEERING↗

Electrostatic graphene speaker

This disclosure provides systems, methods, and apparatus associated with an electrostatically driven graphene speaker. In one aspect, a device includes a graphene membrane, a first frame on a first side of the graphene membrane, and a second frame on a second side of the graphene membrane. The first frame and the second frame both include substantially circular open regions that define a substantially circular portion of the graphene membrane. A first electrode is proximate the first side of the circular portion of the graphene membrane. A second electrode proximate the second side of the circular portion of the graphene membrane.

42 ENGINEERING↗

Internal cooling passages for rotating cutting tools

A cutting tool comprising a tool body comprising a shank and a cutter opposite the shank, the body defining a length from a shank end to an end face opposite the shank end, a central axis extends along the length of the body; at least one tooth having a cutting edge, the cutting edge extending along the tooth from the shank to the end face; a flute formed adjacent the at least one tooth; at least one cooling channel formed in the tooth proximate the at least one cutting edge, the at least one cooling channel having an elongated cross sectional shape with an elliptical portion and a circular portion opposite the elliptical portion, wherein the elliptical portion is located proximate the cutting edge.

Wang, Zhigang↗