Search NASA⌕ Search

SEARCH · Search NASA

Results for “pumping test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Rotordynamic forces on centrifugal pump impellers

The asymmetric flow around an impeller in a volute exerts a force upon the impeller. To study the rotordynamic force on an impeller which is vibrating around its machine axis of rotation, the impeller, mounted on a dynamometer, is made to whirl in a circular orbit within the volute. The measured force is expressed as the sum of a steady radial force and an unsteady force due to the eccentric motion of the impeller. These forces were measured in separate tests on a centrifugal pump with radically increased shroud clearance, a two-dimensional impeller, and an impeller with an inducer, the impeller of the HPOTP (High Pressure Oxygen Turbopump) of the SSME (Space Shuttle Main Engine). In each case, a destabilizing force was observed over a region of positive whirl.

Franz, R.↗

On the feasibility of closed-loop control of intra-aortic balloon pumping

A closed-loop control scheme for the control of intra-aortic balloon pumping has been developed and tested in dog experiments. A performance index reflecting the general objectives of balloon-assist pumping is developed and a modified steepest ascent control algorithm is utilized for the selection of a proper operating point for the balloon during its pumping cycle. This paper attempts to indicate the feasibility of closed-loop control of balloon pumping, and particularly its flexibility in achieving both diastolic augmentation of mean aortic pressure and control of the level of end-diastolic pressure (EDP) an important factor in reducing heart work.

Clark, J. W., Jr.↗

Recent Progress Made in the Development of High-Energy UV Transmitter

In this paper, the status of an all-solid-state UV converter development for ozone sensing applications is discussed. A high energy Nd:YAG laser for pumping the UV converter arrangement was recently reported. The pump is an all-solid-state, single longitudinal mode, and conductively cooled Nd:YAG laser operating at 1064 nm wavelength. Currently, this pump laser provides an output pulse energy of greater than 1J/pulse at 50 Hz PRF and a pulsewidth of 22 ns with an electrical-to-optical system efficiency of greater than 7% and a M(sup 2) value of approx. 2. The spatial profile of the output beam is a rectangular super Gaussian. This Nd:YAG pump laser has been developed to pump the nonlinear optics based UV converter arrangement to generate 320 nm and 308 nm wavelengths by means of 532 nm wavelength. Previously, this UV converter arrangement has demonstrated IR-to-UV conversion efficiency of 24% using a flash lamp pumped laser providing a round, flat top spatial profile. Recently, the UV converter was assembled and tested at NASA LaRC for pumping with the diode pumped Nd:YAG laser. With current spatial profile, the UV converter was made operational. Current efforts to maximize the nonlinear conversion efficiency by refining its spatial profile to match RISTRA OPO requirements are progressing.

Prasad, Narasimha S.↗

PIPER Continuous Adiabatic Demagnetization Refrigerator

We report upon the development and testing of a 4-stage adiabatic demagnetization refrigerator (ADR) capable of continuous cooling at 0.100 Kelvin. This cooler is being built to cool the detector array aboard NASA's Primordial Inflation Polarization Explorer (PIPER) observatory. The goal of this balloon mission is to measure the primordial gravitational waves that should exist if the theory of cosmological inflation is correct. At altitude, the ADR will hold the array of transition-edge sensors at 100 mK continuously while periodically rejecting heat to a 1.2 K pumped helium bath. During testing on ground, the array is held at the same temperature but heat is rejected to a 4.2 K helium bath indicating the flexibility in this coolers design.

Magnetic Cooling Sub-Kelvin ADR↗

Promoted-Combustion Chamber with Induction Heating Coil

An improved promoted-combustion system has been developed for studying the effects of elevated temperatures on the flammability of metals in pure oxygen. In prior promoted-combustion chambers, initial temperatures of metal specimens in experiments have been limited to the temperatures of gas supplies, usually near room temperature. Although limited elevated temperature promoted-combustion chambers have been developed using water-cooled induction coils for preheating specimens, these designs have been limited to low-pressure operation due to the hollow induction coil. In contrast, the improved promoted-combustion chamber can sustain a pressure up to 10 kpsi (69 MPa) and, through utilization of a solid induction coil, is capable of preheating a metal specimen up to its melting point [potentially in excess of 2,000 F (approximately equal to 1,100 C)]. Hence, the improved promoted combustion chamber makes a greater range of physical conditions and material properties accessible for experimentation. The chamber consists of a vertical cylindrical housing with an inner diameter of 8 in. (20.32 cm) and an inner height of 20.4 in. (51.81 cm). A threaded, sealing cover at one end of the housing can be unscrewed to gain access for installing a specimen. Inlet and outlet ports for gases are provided. Six openings arranged in a helical pattern in the chamber wall contain sealed sapphire windows for viewing an experiment in progress. The base of the chamber contains pressure-sealed electrical connectors for supplying power to the induction coil. The connectors feature a unique design that prevents induction heating of the housing and the pressure sealing surfaces; this is important because if such spurious induction heating were allowed to occur, chamber pressure could be lost. The induction coil is 10 in. (25.4 cm) long and is fitted with a specimen holder at its upper end. At its lower end, the induction coil is mounted on a ceramic base, which affords thermal insulation to prevent heating of the base of the chamber during use. A sapphire cylinder protects the coil against slag generated during an experiment. The induction coil is energized by a 6-kW water-cooled power supply operating at a frequency of 400 kHz. The induction coil is part of a parallel-tuned circuit, the tuning of which is used to adjust the coupling of power to the specimen. The chamber is mounted on a test stand along with pumps, valves, and plumbing for transferring pressurized gas into and out of the chamber. In addition to multiple video cameras aimed through the windows encircling the chamber, the chamber is instrumented with gauges for monitoring the progress of an experiment. One of the gauges is a dual-frequency infrared temperature transducer aimed at the specimen through one window. Chamber operation is achieved via a console that contains a computer running apparatus-specific software, a video recorder, and real-time video monitors. For safety, a blast wall separates the console from the test stand.

Richardson, Erin↗

Pressure pulsations above turbomolecular pumps

Lange and Singleton (1978) have observed pressure pulses above a turbomolecular pump. They reported that the mean pulse frequency increased with the temperature of the pump cooling water and that the evolved gas was mainly hydrogen. The present investigation takes into account tests conducted with a similar pumping system. The pumping system was equipped with additional pressure-monitoring equipment in order to study these pulsations in more detail. It was found that at least two distinct types of pressure pulsations may be present in a turbomolecular-pumped ultrahigh vacuum system. The random hydrogen pulses are easily eliminated for period of days by changing the cooling water temperature. The cyclic pulses consisting mainly of water vapor are not likely to be a problem in normal experiments.

Danziger, S.↗

A large high vacuum, high pumping speed space simulation chamber for electric propulsion

Testing high power electric propulsion devices poses unique requirements on space simulation facilities. Very high pumping speeds are required to maintain high vacuum levels while handling large volumes of exhaust products. These pumping speeds are significantly higher than those available in most existing vacuum facilities. There is also a requirement for relatively large vacuum chamber dimensions to minimize facility wall/thruster plume interactions and to accommodate far field plume diagnostic measurements. A 4.57 m (15 ft) diameter by 19.2 m (63 ft) long vacuum chamber at NASA Lewis Research Center is described. The chamber utilizes oil diffusion pumps in combination with cryopanels to achieve high vacuum pumping speeds at high vacuum levels. The facility is computer controlled for all phases of operation from start-up, through testing, to shutdown. The computer control system increases the utilization of the facility and reduces the manpower requirements needed for facility operations.

Grisnik, Stanley P.↗

Summary of Recent Inducer Testing at MSFC and Future Plans

This viewgraph presentation covers water flow tests on the RS-83 Main LOX Inducer for the Space Shuttle Main Engine (SSME). The presentation lists recent water tests on the SSME liquid oxygen (LOX) pump inducer, includes images and diagrams of the water test facility at Marshall Space Flight Center (MSFC), profiles inducer hydrodynamic forces, and diagrams the performance of the RS-83 inducer.

Skelley, Stephen↗

HST Super Lightweight Interchangeable Carrier (SLIC) Static Test

The HST Super Light Weight Interchangeable Carrier Static Test program calls for a total of 15 load cases with an average of 9 simultaneous push/pull locations per load case. This testing program represents the most complex static test ever attempted at Goddard Space Flight Center. Many unique multi-pull fixtures were designed to apply the simultaneous loading. Additionally, a total of 600 channels of data required processing for each loadcase. A total of 1100 separate strain gages were installed on SLIC. A team of 15 trained technicians were needed to apply test loads via mechanical hand pumps for several load cases. All 15 load cases were successfully conducted within 15 weeks. The ManTech team successfully tested all SLIC 1200 interface clips to the required testing loads. Several unique designs were needed to address testing challenges as loadline interference, Payload Safety, payload flexibility and opposing load applications.

Chambers, William V.↗

Investigation of the HPFTP first stage impeller crack

The occurrence of a crack in the HPFTP first stage impeller of pump 2608 R2 during test 750-245 prompted this analysis to examine possible causes of the failure. Preliminary analysis, using an existing NASTRAN model of the impeller, showed a deficiency in the model's ability to reliably calculate stress in the area of concern (outboard edge of the impeller shroud). A new NASTRAN model was constructed to better define the stress state in the area of crack initiations. Static stress analysis and normal models analysis were performed on the new model. Results are presented.

Source record↗

An integrated development facility for the calibration of low-energy charged particle flight instrumentation

A system was developed for the calibration and development of thermal ion instrumentation. The system provides an extended beam with usable current rates, approx. 1 pA/sq cm, at beam energies as low as 1 eV, with much higher values available with increasing energy. A tandem electrostatic and variable geometry magnetic mirror configuration within the ion source optimizes the use of the ionizing electrons. The system is integrated under microcomputer control to allow automatic control and monitoring of the beam energy and composition and the mass and angle-dependent response of the instrument under test. The system is pumped by a combination of carbon vane and cryogenic sorption roughing pumps and ion and liquid helium operating pumps.

Biddle, A. P.↗

Development of mid-infrared solid state lasers for spaceborne lidar

The laser performance of a Ho(3+):Tm(3+):Cr(3+):YAG crystal was measured under flashlamp pumping at various operating temperatures. The normal mode laser thresholds of a Ho(3+)(0.45 at. percent):Tm(3+)(2.5 at. percent):Cr(3+)(1.5 at. percent ):YAG crystal were found to range from 26 to 50 J between 120 and 200 K with slope efficiencies up to 0.36 percent with a 60 percent reflective output mirror. From the Q-switched operations a slope efficiency corresponding to 90 percent of the normal mode operation was observed. Laser wavelengths were measured for various operating conditions and fluorescence spectra were obtained at various temperatures in order to help understand the dynamic energy processes among the Ho(3+), Tm(3+), and Cr(3+) ions. A pulse forming network for a flashlamp pumped Cr:GSAG laser, which is to be used as a high power laser diode simulator in rare earth laser pumping, was completed and tested. The network provided critically damped, 1 ms FWHM, square pulses with a rise time of about 160 micrometers at an input electrical energy of 300 J.

Whitney, Donald A.↗