Search NASA⌕ Search

SEARCH · Search NASA

Results for “quantitative microscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Defining cell culture conditions to improve human norovirus infectivity assays

Significant difficulties remain for determining whether human noroviruses (hNoV) recovered from water, food, and environmental samples are infectious. Three-dimensional tissue culture of human intestinal cells has shown promise in developing an infectivity assay, but reproducibility, even within a single laboratory, remains problematic. From the literature and our observations, we hypothesized that the common factors that leads to more reproducible hNoV infectivity in vitro requires that the cell line be 1) of human gastrointestinal origin, 2) expresses apical microvilli, and 3) be a positive secretor cell line. The C 2 BBe1 cell line, which is a brush-border producing clone of Caco-2, meets these three criteria. When challenged with Genogroup II viruses, we observed a 2 Log10 increase in viral RNA titer. A passage experiment with GII viruses showed evidence of the ability to propagate hNoV by both reverse transcription quantitative PCR (qRT-PCR) and microscopy. Using 3-D C 2 BBe1 cells improves reproducibility of the infectivity assay for hNoV, but the assay can still be variable. Two sources of variability include the cells themselves (mixed phenotypes of small and large intestine) and initial titer measurements using quantitative reverse transcription PCR (qRT-PCR) that measures all RNA vs. plaque assays that measure infectious virus.

C2BBe1 cells↗

Quantitative assessment of sample stiffness and sliding friction from force curves in atomic force microscopy

It has long been recognized that the angular deflection of an atomic force microscope (AFM) cantilever under ''normal'' loading conditions can be profoundly influenced by the friction between the tip and the surface. It is shown here that a remarkably quantifiable hysteresis occurs in the slope of loading curves whenever the normal flexural stiffness of the AFM cantilever is greater than that of the sample. This situation arises naturally in cantilever-on-cantilever calibration, but also when trying to measure the stiffness of nanomechanical devices or test structures, or when probing any type of surface or structure that is much more compliant along the surface normal than in transverse directions. Expressions and techniques for evaluating the coefficient of sliding friction between the cantilever tip and sample from normal force curves, as well as relations for determining the stiffness of a mechanically compliant specimen are presented. The model is experimentally supported by the results of cantilever-on-cantilever spring constant calibrations. The cantilever spring constants determined here agree with the values determined using the NIST electrostatic force balance within the limits of the largest uncertainty component, which had a relative value of less than 2.5%. This points the way for quantitative testing of micromechanical and nanomechanical components, more accurate calibration of AFM force, and provides nanotribologists access to information about contact friction from normal force curves.

36 MATERIALS SCIENCE↗

Soft X-Ray Tomography Has Evolved into a Powerful Tool for Revealing Cell Structures

Over the past three decades, soft X-ray tomography (SXT) has rapidly evolved from a proof-of-concept microscopy method into a high-throughput quantitative imaging modality. This advancement enables researchers to address central questions in cell biology. Despite its relatively short developmental period compared to light and electron microscopy, SXT has emerged as a powerful imaging technology. It enables measuring chemical changes in cellular organelles, analyzing three-dimensional structures of whole cells and creating digital cellular models to study cell motility. We discuss the unique nature of SXT to visualize cells without fixation or labeling, enabling quantitative analyses of organelle chemical composition. We explore SXT microscopes available worldwide, SXT segmentation software, and the diverse cell types studied using this technique. We conclude with emerging directions in SXT imaging, including a brief discussion of recent discoveries that are highly influential and likely to become integral to cell biology textbooks.

Weinhardt, Venera↗

Investigation of historical metal objects using Laser Induced Breakdown Spectroscopy (LIBS) technique

Analysis of metal objects is a necessary step for establishing an appropriate conservation treatment of an object or to follow up the application's result of the suggested treatments. The main considerations on selecting a method that can be used in investigation and analysis of metal objects are based on the diagnostic power, representative sampling, reproducibility, destructive nature/invasiveness of analysis and accessibility to the appropriate instrument. This study aims at evaluating the usefulness of the use of Laser Induced Breakdown Spectroscopy (LIBS) Technique for analysis of historical metal objects. In this study various historical metal objects collected from different museums and excavations in Egypt were investigated using (LIBS) technique. For evaluating usefulness of the suggested analytical protocol of this technique, the same investigated metal objects were investigated by other methods such as Scanning Electron Microscope with energy-dispersive x-ray analyzer (SEM-EDX) and X-ray Diffraction (XRD). This study confirms that Laser Induced Breakdown Spectroscopy (LIBS) Technique is considered very useful technique that can be used safely for investigating historical metal objects. LIBS analysis can quickly provide information on the qualitative and semi-quantitative elemental content of different metal objects and their characterization and classification. It is practically non-destructive technique with the critical advantage of being applicable in situ, thereby avoiding sampling and sample preparations. It is can be dependable, satisfactory and effective method for low cost study of archaeological and historical metals. But we have to take into consideration that the corrosion of metal leads to material alteration and possible loss of certain metals in the form of soluble salts. Certain corrosion products are known to leach out of the object and therefore, their low content does not necessarily reflect the composition of the metal at the time of the object manufacture. Another point should be taken into consideration that the heterogeneity of a metal alloy object that often result from poor mixing of the different metal alloy composition.There is a necessity to carry out further research to investigate and determine the most appropriate and effective approaches and methods for conservation of these metal objects.

36 MATERIALS SCIENCE↗

Quantitative phase separation in multiferroic Bi{sub 0.88}Sm{sub 0.12}FeO{sub 3} ceramics via piezoresponse force microscopy

BiFeO{sub 3} (BFO) is a classical multiferroic material with both ferroelectric and magnetic ordering at room temperature. Doping of this material with rare-earth oxides was found to be an efficient way to enhance the otherwise low piezoelectric response of unmodified BFO ceramics. In this work, we studied two types of bulk Sm-modified BFO ceramics with compositions close to the morphotropic phase boundary (MPB) prepared by different solid-state processing methods. In both samples, coexistence of polar R3c and antipolar P{sub bam} phases was detected by conventional X-ray diffraction (XRD); the non-polar P{sub nma} or P{sub bnm} phase also has potential to be present due to the compositional proximity to the polar-to-non-polar phase boundary. Two approaches to separate the phases based on the piezoresponse force microscopy measurements have been proposed. The obtained fractions of the polar and non-polar/anti-polar phases were close to those determined by quantitative XRD analysis. The results thus reveal a useful method for quantitative determination of the phase composition in multi-phase ceramic systems, including the technologically most important MPB systems.

36 MATERIALS SCIENCE↗

On the use of peak-force tapping atomic force microscopy for quantification of the local elastic modulus in hardened cement paste

A surface of epoxy-impregnated hardened cement paste was investigated using a novel atomic force microscopy (AFM) imaging mode that allows for the quantitative mapping of the local elastic modulus. The analyzed surface was previously prepared using focussed ion beam milling. The same surface was also characterized by electron microscopy and energy-dispersive X-ray spectroscopy. We demonstrate the capability of this quantitative nanomechanical mapping to provide information on the local distribution of the elastic modulus (from about 1 to about 100 GPa) with a spatial resolution in the range of decananometers, that corresponds to that of low-keV back-scattered electron imaging. Despite some surface roughness which affects the measured nanomechanical properties it is shown that topography, adhesion and Young's modulus can be clearly distinguished. The quantitative mapping of the local elastic modulus is able to discriminate between phases in the cement paste microstructure that cannot be distinguished from the corresponding back-scattered electron images.

36 MATERIALS SCIENCE↗

Nanoscale Disorder and Local Electronic Properties of CaCu,Ti,012: An Integrated Study of Electron, Neutron and X-ray Diffraction, X-ray Absorption Fine Structure and First Principles Calculations

We report a combined experimental and theoretical study of CaCu{sub 3}Ti{sub 4}O{sub 12}. Based on our experimental observations of nanoscale regions of Ca-Cu antisite defects in part of the structure, we carried out density-functional theory (DFT) calculations that suggest a possible electronic mechanism to explain the gigantic dielectric response in this material. The defects are evident in atomically resolved transmission electron microscopy measurements, with supporting evidence from a quantitative analysis of the electron diffraction and DFT which suggests that such defects are reasonable on energetic grounds. To establish the extent of the defects, bulk average measurements of the local structure were carried out: extended x-ray absorption fine structure (EXAFS), atomic pair-distribution function analysis of neutron powder-diffraction data, and single-crystal x-ray crystallography. The EXAFS data are consistent with the presence of the nanoclustered defects with an estimate of less than 10% of the sample being disordered while the neutron powder-diffraction experiments place an upper of -5% on the proportion of the sample in the defective state. Because of the difficulty of quantifying nanoscale defects at such low levels, further work will be required to establish that this mechanism is operative in CaCu{sub 3}Ti{sub 4}O{sub 12} but it presents a nontraditional plausible avenue for understanding colossal dielectric behavior.

36 MATERIALS SCIENCE↗

Cobalt oxide hollow microspheres with micro- and nano-scale composite structure: Fabrication and electrochemical performance

Co{sub 3}O{sub 4} hollow microspheres with micro- and nano-scale composite structure self-assembled by nanosheets were successfully fabricated by the template-free wet-chemical approach. This method is simple, facile and effective. The Co{sub 3}O{sub 4} hollow microspheres with good purity and homogeneous size were well characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM), X-ray diffraction (XRD), Fourier transform IR (FTIR), thermogravimetric analysis (TGA) and inductively coupled plasma atomic emission spectrometer (ICP). The formation mechanism was deeply studied. The micro- and nano-scale composite structure constructed by the porous nanosheets promotes to improve the electrochemical properties of Co{sub 3}O{sub 4} hollow microspheres. The high discharge capacity of 1048 mAh g{sup -1} indicates it to be the potential application in electrode materials of Li-ion battery. - Graphical Abstract: Co{sub 3}O{sub 4} hollow microspheres self-assembled by nanosheets are successfully fabricated by a template-free wet-chemical approach. The hollow microspheres are in good morphology purity and homogeneous size. Co{sub 3}O{sub 4} hollow microspheres constructed by porous nanosheets show the high discharge capacity of 1048 mAh g{sup -1}, indicating it to be the potential electrode material of Li-ion battery.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Composition profiling of GaAs/AlGaAs quantum dots grown by droplet epitaxy

Droplet epitaxy (DE) is a growth method which can create III-V quantum dots (QDs) whose optoelectronic properties can be accurately controlled through the crystallisation conditions. In this work, GaAs/AlGaAs DE-QDs have been analyzed with the complimentary techniques of cross-sectional scanning tunneling microscopy and atom probe tomography. Structural details and a quantitative chemical analysis of QDs of different sizes are obtained. Most QDs were found to be pure GaAs, while a small proportion exhibited high intermixing caused by a local etching process. Large QDs with a high aspect ratio were observed to have an Al-rich crown above the GaAs QD. This structure is attributed to differences in mobility of the cations during the capping phase of the DE growth.

36 MATERIALS SCIENCE↗

Quantitative Observation of Threshold Defect Behavior in Memristive Devices with Operando X-ray Microscopy

Memristive devices are an emerging technology that enables both rich interdisciplinary science and novel device functionalities, such as nonvolatile memories and nanoionics-based synaptic electronics. Recent work has shown that the reproducibility and variability of the devices depend sensitively on the defect structures created during electroforming as well as their continued evolution under dynamic electric fields. However, a fundamental principle guiding the material design of defect structures is still lacking due to the difficulty in understanding dynamic defect behavior under different resistance states. Here, we unravel the existence of threshold behavior by studying model, single-crystal devices: resistive switching requires that the pristine oxygen vacancy concentration reside near a critical value. Theoretical calculations show that the threshold oxygen vacancy concentration lies at the boundary for both electronic and atomic phase transitions. Through operando , multimodal X-ray imaging, we show that field tuning of the local oxygen vacancy concentration below or above the threshold value is responsible for switching between different electrical states. Lastly, these results provide a general strategy for designing functional defect structures around threshold concentrations to create dynamic, field-controlled phases for memristive devices.

36 MATERIALS SCIENCE↗

Microwave Microscopy and Its Applications

Understanding the nanoscale electrodynamic properties of a material at microwave frequencies is of great interest for materials science, condensed matter physics, device engineering, and biology. With specialized probes, sensitive detection electronics, and improved scanning platforms, microwave microscopy has become an important tool for cutting-edge materials research in the past decade. In this article, we review the basic components and data interpretation of microwave imaging and its broad range of applications. In addition to the general-purpose mapping of permittivity and conductivity, microwave microscopy is now exploited to perform quantitative measurements on semiconductor devices, photosensitive materials, ferroelectric domains and domain walls, and acoustic-wave systems. Implementation of the technique in low-temperature and high-magnetic-field chambers has also led to major discoveries in quantum materials with strong correlation and topological order. We conclude the review with an outlook of the ultimate resolution, operation frequency, and future industrial and academic applications of near-field microwave microscopy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterising aggregate surface geometry in thin-sections of mortar and concrete

Measurement of microstructural gradients at the aggregate/cement paste interfacial transition zone (ITZ) in hardened mortar and concrete is commonly performed via quantitative image analysis of multiple micrographs of specimen surfaces, using a scanning electron microscope. However, due to the random orientation of interfaces sectioned by the specimen surface, measurements of the microstructural gradients at the interface have an unknown angular component, and thus have an unknown error. We present a method for the identification of interfaces that are perpendicular to the specimen surface, and therefore, are more suitable for accurate ITZ analysis. This method employs simple optical and electron imaging techniques on petrographic thin-sections. Use of 3D laser scanning confocal microscopy helped to validate the method. Quantitative 2D image analysis of backscattered electron micrographs, captured over three angular classes of interface gives an indication of this error in the determination of interfacial porosity and anhydrous cement content.

36 MATERIALS SCIENCE↗

Evaluation of Delamination of X80 Pipeline Steel Coating Under Alternating Stray Current Via Scanning Electrochemical Microscopy

The delamination of epoxy coating on X80 pipeline steel was evaluated under various stray alternating current (AC) interferences (0-300 A/m{sup 2}). Qualitative and quantitative analyses were carried out using scanning electrochemical microscopy (SECM), electrochemical impedance spectroscopy (EIS), and three-dimensional digital microscopy. The results show that the SECM current is directly proportional to the soaking time and applied current density. The variation in SECM current curve shape indicates the delamination distance of epoxy coatings at the defect area. The depths of corrosion pits at 50, 100, and 300 A/m{sup 2} stray currents were 140, 160, and 240 μm, respectively. The corrosion pits also became wider with increasing current densities. With increasing stray AC densities, both the coating delamination and pit depth became more severe at the same soaking time. The EIS results show that the change in impedance was not significant without stray current, whereas the impedance first decreased and then increased when stray current was applied. These results are consistent with the SECM measurements.

36 MATERIALS SCIENCE↗

Quantitative Analysis of Rhodobacter sphaeroides Storage Organelles via Cryo-Electron Tomography and Light Microscopy

Bacterial cytoplasmic organelles are diverse and serve many varied purposes. Here, we employed Rhodobacter sphaeroides to investigate the accumulation of carbon and inorganic phosphate in the storage organelles, polyhydroxybutyrate (PHB) and polyphosphate (PP), respectively. Using cryo-electron tomography (cryo-ET), these organelles were observed to increase in size and abundance when growth was arrested by chloramphenicol treatment. The accumulation of PHB and PP was quantified from three-dimensional (3D) segmentations in cryo-tomograms and the analysis of these 3D models. The quantification of PHB using both segmentation analysis and liquid chromatography and mass spectrometry (LCMS) each demonstrated an over 10- to 20-fold accumulation of PHB. The cytoplasmic location of PHB in cells was assessed with fluorescence light microscopy using a PhaP-mNeonGreen fusion-protein construct. The subcellular location and enumeration of these organelles were correlated by comparing the cryo-ET and fluorescence microscopy data. A potential link between PHB and PP localization and possible explanations for co-localization are discussed. Finally, the study of PHB and PP granules, and their accumulation, is discussed in the context of advancing fundamental knowledge about bacterial stress response, the study of renewable sources of bioplastics, and highly energetic compounds.

59 BASIC BIOLOGICAL SCIENCES↗

Key Parameters Affecting Quantitative Analysis of STEM-EDS Spectrum Images

In this article, we use simulated and experimental data to explore how three operator-controllable parameters - (1) signal level, (2) detector resolution, and (3) number of factors chosen for analysis - affect quantitative analyses of scanning transmission electron microscopy-energy dispersive X-ray spectroscopy spectrum images processed by principal component analysis (PCA). We find that improvements in both signal level and detector resolution improve the precision of quantitative analyses, but that signal level is the most important. We also find that if the rank of the PCA solution is not chosen properly, it may be possible to improperly fit the underlying data and degrade the accuracy of results. Additionally, precision is degraded in the case when too many factors are included in the model.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗