Search NASA⌕ Search

SEARCH · Search NASA

Results for “quantum image processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Theoretical and experimental analysis of AlGaInP micro-LED array with square-circle anode

An array of 320 × 240 micro-light-emitting diodes (micro-LEDs) based on an AlGaInP epitaxial wafer and with a unit size of 100 µm×100 µm was designed and fabricated. The optimum width of the isolation groove between adjacent light-emitting units was determined based on a compromise between full isolation of each LED and maximization of the light emitting area, and was found to be 20 µm. The grooves were filled with a mixed Si granule-polyurethane composite medium, because this type of insulating material can reflect part of the emitted light from the sidewall to the window layer in each light-emitting unit, and could thus improve lighting output efficiency. The 10-µm-wide square-circle anode was designed to increase the light emitting area while simultaneously being simple to fabricate. The device current used was in the 0.42–1.06 mA range to guarantee internal quantum efficiency of more than 85%, with a corresponding voltage range of 2–2.3 V. The layered temperature distribution in a single unit was simulated under a drive voltage of 2.2 V, and the maximum device temperature was 341 K. The micro-opto-electro-mechanical systems (MOEMS) technology-based fabrication process, experimental images of the device and device test results are presented here.

36 MATERIALS SCIENCE↗

On-chip generation and control of the vortex beam

A method to generate and control the amplitude and phase distributions of an optical vortex beam is proposed. By introducing a holographic grating on the top of a dielectric waveguide, the free space vortex beam and the in-plane guiding wave can be converted to each other. This microscale holographic grating is very robust against the variation of geometry parameters. The designed vortex beam generator can produce the target beam with a fidelity up to 0.93, and the working bandwidth is about 175 nm with the fidelity larger than 0.80. In addition, a multiple generator composed of two holographic gratings on two parallel waveguides is studied, which can perform an effective and flexible modulation on the vortex beam by controlling the phase of the input light. Our work opens an available avenue towards the integrated orbital angular momentum devices with multiple degrees of optical freedom, which can be used for optical tweezers, micronano imaging, information processing, and so on.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

X-ray microtomographic scanners

The article studies the operating procedures of an X-ray microtomographic scanner and the module of reconstruction and analysis 3D-image of a test sample in particular. An algorithm for 3D-image reconstruction based on image shadow projections and mathematical methods of the processing are described. Chapter 1 describes the basic principles of X-ray tomography and general procedures of the device developed. Chapters 2 and 3 are devoted to the problem of resources saving by the system during the X-ray tomography procedure, which is achieved by preprocessing of the initial shadow projections. Preprocessing includes background noise removing from the images, which reduces the amount of shadow projections in general and increases the efficiency of the group shadow projections compression. In conclusion, the main applications of X-ray tomography are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A glimpse of gluons through deeply virtual compton scattering on the proton

The proton is composed of quarks and gluons, bound by the most elusive mechanism of strong interaction called confinement. In this work, the dynamics of quarks and gluons are investigated using deeply virtual Compton scattering (DVCS): produced by a multi-GeV electron, a highly virtual photon scatters off the proton which subsequently radiates a high energy photon. Similarly to holography, measuring not only the magnitude but also the phase of the DVCS amplitude allows to perform 3D images of the internal structure of the proton. The phase is made accessible through the quantum-mechanical interference of DVCS with the Bethe-Heitler (BH) process, in which the final photon is emitted by the electron rather than the proton. Here, we report herein the first full determination of the BH-DVCS interference by exploiting the distinct energy dependences of the DVCS and BH amplitudes. In the high energy regime where the scattering process is expected to occur off a single quark in the proton, these accurate measurements show an intriguing sensitivity to gluons, the carriers of the strong interaction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of an assisting detection system for early infarct diagnosis

In this paper, a detection assisting system for early infarct detection is developed. This new developed method is used to assist the medical practitioners to diagnose infarct from computed tomography images of brain. Using this assisting system, the infarct could be diagnosed at earlier stages. The non-contrast computed tomography (NCCT) brain images are the data set used for this system. Detection module extracts the pixel data from NCCT brain images, and produces the colourized version of images. The proposed method showed great potential in detecting infarct, and helps medical practitioners to make earlier and better diagnoses.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accuracy of volume measurement using 3D ultrasound and development of CT-3D US image fusion algorithm for prostate cancer radiotherapy

Purpose: To evaluate the accuracy of measuring volumes using three-dimensional ultrasound (3D US), and to verify the feasibility of the replacement of CT-MR fusion images with CT-3D US in radiotherapy treatment planning. Methods: Phantoms, consisting of water, contrast agent, and agarose, were manufactured. The volume was measured using 3D US, CT, and MR devices. A CT-3D US and MR-3D US image fusion software was developed using the Insight Toolkit library in order to acquire three-dimensional fusion images. The quality of the image fusion was evaluated using metric value and fusion images. Results: Volume measurement, using 3D US, shows a 2.8 {+-} 1.5% error, 4.4 {+-} 3.0% error for CT, and 3.1 {+-} 2.0% error for MR. The results imply that volume measurement using the 3D US devices has a similar accuracy level to that of CT and MR. Three-dimensional image fusion of CT-3D US and MR-3D US was successfully performed using phantom images. Moreover, MR-3D US image fusion was performed using human bladder images. Conclusions: 3D US could be used in the volume measurement of human bladders and prostates. CT-3D US image fusion could be used in monitoring the target position in each fraction of external beam radiation therapy. Moreover, the feasibility of replacing the CT-MR image fusion to the CT-3D US in radiotherapy treatment planning was verified.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantitative analysis of autoradiographic image intensification using Thiourea-S35

Photographic images enhanced by the method of Thiourea-S35 autoradiography are evaluated in terms of signal-to-noise ratio, detective quantum efficiency (DQE), and Wiener spectrum analysis using digitized images. It is determined that the original signal-to-noise ratio is not degraded by the intensification process which allows an increase in the practical working DQE as a function of density. These results apply at all spatial frequencies that were tested. The advantage given by autoradiography is the ability to produce usable images from emulsions originally exposed to the low densities corresponding to maximum DQE and movement of faint image densities above the level of the threshold for detection.

Askins, B. S.↗

Entanglement Enabled Intensity Interferometry of different wavelengths of light

Highlights: • We use quantum entanglement to erase the color of photons for a new imaging method. • Can achieve higher resolution imaging by accessing hidden phase information. • We detail practical experimental designs to implement our theoretical protocols. We propose methods to perform intensity interferometry of photons having two different wavelengths. Distinguishable particles typically cannot interfere with each other, but we overcome that obstacle by processing the particles via entanglement and projection so that they lead to the same final state at the detection apparatus. Specifically, we discuss how quasi-phase-matched nonlinear crystals can be used to convert a quantum superposition of light of different wavelengths onto a common wavelength, while preserving the phase information essential for their meaningful interference. We thereby gain access to a host of new observables, which can probe subtle frequency correlations and entanglement. Further, we generalize the van Cittert–Zernike formula for the intensity interferometry of extended sources, demonstrate how our proposal supports enhanced resolution of sources with different spectral character, and suggest potential applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An improved back projection algorithm of ultrasound tomography

Binary logic back projection algorithm is improved in this work for the development of fast ultrasound tomography system with a better effect of image reconstruction. The new algorithm is characterized by an extra logical value ‘2’ and dual-threshold processing of collected raw data. To compare with the original algorithm, a numerical simulation was conducted by the verification of COMSOL simulations formerly, and then a set of ultrasonic tomography system is established to perform the experiments of one, two and three cylindrical objects. The object images are reconstructed through the inversion of signals matrix acquired by the transducer array after a preconditioning, while the corresponding spatial imaging errors can obviously indicate that the improved back projection method can achieve modified inversion effect.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantum-Compatible Variational Segmentation for Image-to-Image Wildfire Detection Using Satellite Data

Wildfire occurrences have been increasing for the past decade, leaving devastating traces across the world. In the recent efforts, remote sensing and airborne missions have been utilized to better understand and manage wildfires. This has resulted in an exponential increase in volume of remote sensing data, which has pushed the need for intelligent automation of data extraction for wildfire studies. Machine learning offers accurate automation in detecting such natural anomalies and enable decision-makers to take actions in a timely manner. Recent advances in machine learning algorithms, namely probabilistic generative methods, allow researchers and decisionmakers to step beyond detection and study “what-if” scenarios for wildfire occurrences. Additionally, they offer better imitations to the stochastic behavior of nature, and wildfire events. However, optimizing the performance of these probabilistic generative models is a computationally expensive process, specially using digital computers. On the other hand, quantum computers have recently shown a promise to reduce computationally costly training of such models and provide performance improvements. There is a body of research investigating the potential for improved machine learning methods in which key operations are performed on a quantum computer. In this study, we propose a probabilistic image-toimage segmentation approach combining a very well-known segmentation method, U-NET, with a Conditional Variational Auto-Encoder (CVAE) to not only detect wildfires but also describe the stochasticity of the phenomenon and be capable of running “what-if” scenarios. Our proposed model is compatible with training on quantum computers, which results in a quantum-assisted image-to-image segmentation approach and can be used to benchmark the potential benefit of quantum computing over the classical one.

quantum↗

Evaluation of negative ion distribution changes by image processing diagnostic

Distributions of hydrogen Balmer-α (H{sub α}) intensity and its reduction behavior close to a plasma grid (PG) surface have been observed by a spectrally selective imaging system in an arc discharge type negative hydrogen ion source in National Institute for Fusion Science. H{sub α} reduction indicates a reduction of negative hydrogen ions because the mutual neutralization process between H{sup +} and H{sup −} ions causes the dominant excitation process for H{sub α} emission in the rich H{sup −} condition such as in ionic plasma. We observed a significant change in H{sub α} reduction distribution due to change in the bias voltage, which is used to suppress the electron influx. Small H{sub α} reduction in higher bias is likely because the production of negative ions is suppressed by the potential difference between the plasma and PG surface.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimization of phosphor-based detector design for oblique x-ray incidence in digital breast tomosynthesis

Purpose: In digital breast tomosynthesis (DBT), a volumetric reconstruction of the breast is generated from a limited range of x-ray projections. One trade-off of DBT is resolution loss in the projections due to non-normal (i.e., oblique) x-ray incidence. Although degradation in image quality due to oblique incidence has been studied using empirical data and Monte Carlo simulations, a theoretical treatment has been lacking. The purpose of this work is to extend Swank's calculations of the transfer functions of turbid granular phosphors to oblique incidence. The model is ultimately used as a tool for optimizing the design of DBT detectors. Methods: A quantum-limited system and 20 keV x-rays are considered. Under these assumptions, the modulation transfer function (MTF) and noise power spectra (NPS) are derived using the diffusion approximation to the Boltzmann equation to model optical scatter within the phosphor. This approach is applicable to a nonstructured scintillator such as gadolinium oxysulfide doped with terbium (Gd{sub 2}O{sub 2}S:Tb), which is commonly used in breast imaging and which can reasonably approximate other detector materials. The detective quantum efficiency (DQE) is then determined from the Nishikawa formulation, where it is written as the product of the x-ray quantum detection efficiency, the Swank factor, and the Lubberts fraction. Transfer functions are calculated for both front- and back-screen configurations, which differ by positioning the photocathode at the exit or entrance point of the x-ray beam, respectively. Results: In the front-screen configuration, MTF and DQE are found to have considerable angular dependence, while NPS is shown to vary minimally with projection angle. As expected, the high frequency MTF and DQE are degraded substantially at large angles. By contrast, all transfer functions for the back-screen configuration have the advantage of significantly less angular dependence. Using these models, we investigated the possibility for optimizing the design of DBT detectors. As an example optimization strategy, the phosphor thickness which maximizes the DQE at a fixed frequency is analyzed. This work demonstrates that the optimal phosphor thickness for the front-screen is angularly dependent, shifting to lower thickness at higher angles. Conversely, the back-screen is not optimized by a single thickness but instead attains reasonably high DQE values over a large range of thicknesses. Although the back-screen configuration is not suited for current detectors using a glass substrate, it may prove to be preferred in future detectors using newly proposed plastic thin-film transistor (TFT) substrates. Conclusions: Using the diffusion approximation to the Boltzmann equation to model the spread of light in a scintillator, this paper develops an analytical model of MTF, NPS, and DQE for a phosphor irradiated obliquely. The model is set apart from other studies on oblique incidence in being derived from first principles. This work has applications in the optimization of DBT detector design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Matrix phased array (MPA) imaging technology for resistance spot welds

A three-dimensional MPA probe has been incorporated with a high speed phased array electronic board to visualize nugget images of resistance spot welds. The primary application area of this battery operated portable MPA ultrasonic imaging system is in the automotive industry which a conventional destructive testing process is commonly adopted to check the quality of resistance spot welds in auto bodies. Considering an average of five-thousand spot welds in a medium size passenger vehicle, the amount of time and effort given to popping the welds and measuring nugget size are immeasurable in addition to the millions of dollars' worth of scrap metals recycled per plant per year. This wasteful labor intensive destructive testing process has become less reliable as auto body sheet metal has transitioned from thick and heavy mild steels to thin and light high strength steels. Consequently, the necessity of developing a non-destructive inspection methodology has become inevitable. In this paper, the fundamental aspects of the current 3-D probe design, data acquisition algorithms, and weld nugget imaging process are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low temperature multi-alkali photocathode processing technique for sealed intensified CCD tubes

A low temperature photocathode process has been used to fabricate an intensified CCD visual photocathode image tube, by incorporating a thinned, backside-illumined CCD as the target anode of a digicon tube of Hubble Space Telescope (HST) design. The CCD digicon tube employs the HST's sodium bialkali photocathode and MgF2 substrate, thereby allowing a direct photocathode quantum efficiency comparison between photocathodes produced by the presently employed low temperature process and those of the conventional high temperature process. Attention is given to the processing chamber used, as well as the details of gas desorption and photocathode processing.

Doliber, D. L.↗

Frequency-domain computing using nonlinear acoustic-wave device on lithium niobate

Abstract Multiply-accumulation are crucial computing operations in signal processing, numerical simulations, and machine learning. In recent years, optical analog approaches have demonstrated higher computing performance and better power efficiency than their digital counterparts. However, analog computing chips usually need large areas and complex structures for parallel computing, as a single device element only executes one computing operation at a single time. Here, we demonstrate frequency-domain computing using the nonlinear acoustic-wave devices on lithium niobate, featuring a normalized external second-harmonic generation conversion efficiency of ~ 5.7 × 10-4 W-1. The second-order sum-frequency nonlinear process of lithium niobate enables multiplication of inputs encoded in the frequency domain. Compared to the analog schemes, our device features a notably simpler design, and nanofabrication requires only one lift-off. Using a single acoustic-wave device within an area of 0.03 mm2, we can simultaneously conduct over 130,000 multiply-accumulation operations. Our acoustic-wave device shows applications in real and complex vector convolutions and image processing. This demonstration sets the stage for experimental realizations into frequency-domain integrated nonlinear acoustic computing systems, potentially shaping future developments in acoustic neural networks and quantum computing.

chai, mingzhao (ORCID:0009000466226341)↗

Temporal and spectral imaging with micro-CT

Purpose: Micro-CT is widely used for small animal imaging in preclinical studies of cardiopulmonary disease, but further development is needed to improve spatial resolution, temporal resolution, and material contrast. We present a technique for visualizing the changing distribution of iodine in the cardiac cycle with dual source micro-CT. Methods: The approach entails a retrospectively gated dual energy scan with optimized filters and voltages, and a series of computational operations to reconstruct the data. Projection interpolation and five-dimensional bilateral filtration (three spatial dimensions + time + energy) are used to reduce noise and artifacts associated with retrospective gating. We reconstruct separate volumes corresponding to different cardiac phases and apply a linear transformation to decompose these volumes into components representing concentrations of water and iodine. Since the resulting material images are still compromised by noise, we improve their quality in an iterative process that minimizes the discrepancy between the original acquired projections and the projections predicted by the reconstructed volumes. The values in the voxels of each of the reconstructed volumes represent the coefficients of linear combinations of basis functions over time and energy. We have implemented the reconstruction algorithm on a graphics processing unit (GPU) with CUDA. We tested the utility of the technique in simulations and applied the technique in an in vivo scan of a C57BL/6 mouse injected with blood pool contrast agent at a dose of 0.01 ml/g body weight. Postreconstruction, at each cardiac phase in the iodine images, we segmented the left ventricle and computed its volume. Using the maximum and minimum volumes in the left ventricle, we calculated the stroke volume, the ejection fraction, and the cardiac output. Results: Our proposed method produces five-dimensional volumetric images that distinguish different materials at different points in time, and can be used to segment regions containing iodinated blood and compute measures of cardiac function. Conclusions: We believe this combined spectral and temporal imaging technique will be useful for future studies of cardiopulmonary disease in small animals.

60 APPLIED LIFE SCIENCES↗

Detecting brain tumor in computed tomography images using Markov random fields and fuzzy C-means clustering techniques

Brain tumors, are an abnormal growth of tissues in the brain. They may arise in people of any age. They must be detected early, diagnosed accurately, monitored carefully, and treated effectively in order to optimize patient outcomes regarding both survival and quality of life. Manual segmentation of brain tumors from CT scan images is a challenging and time consuming task. Size and location accurate detection of brain tumor plays a vital role in the successful diagnosis and treatment of tumors. Brain tumor detection is considered a challenging mission in medical image processing. The aim of this paper is to introduce a scheme for tumor detection in CT scan images using two different techniques Hidden Markov Random Fields (HMRF) and Fuzzy C-means (FCM). The proposed method has been developed in this research in order to construct hybrid method between (HMRF) and threshold. These methods have been applied on 4 different patient data sets. The result of comparison among these methods shows that the proposed method gives good results for brain tissue detection, and is more robust and effective compared with (FCM) techniques.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Atomic resolution scanning transmission electron microscopy at liquid helium temperatures for quantum materials

Fundamental quantum phenomena in condensed matter, ranging from correlated electron systems to quantum information processors, manifest their emergent characteristics and behaviors predominantly at low temperatures. This necessitates the use of liquid helium (LHe) cooling for experimental observation. Atomic resolution scanning transmission electron microscopy combined with LHe cooling (cryo-STEM) provides a powerful characterization technique to probe local atomic structural modulations and their coupling with charge, spin and orbital degrees-of-freedom in quantum materials. However, achieving atomic resolution in cryo-STEM is exceptionally challenging, primarily due to sample drifts arising from temperature changes and noises associated with LHe bubbling, turbulent gas flow, etc. In this work, we demonstrate atomic resolution cryo-STEM imaging at LHe temperatures using a commercial side-entry LHe cooling holder. Firstly, we examine STEM imaging performance as a function of He gas flow rate, identifying two primary noise sources: He-gas pulsing and He-gas bubbling. Secondly, we propose two strategies to achieve low noise conditions for atomic resolution STEM imaging: either by temporarily suppressing He gas flow rate using the needle valve or by acquiring images during the natural warming process. Lastly, we show the applications of image acquisition methods and image processing techniques in investigating structural phase transitions in Cr 2 Ge 2 Te 6 , CuIr 2 S 4 , and CrCl 3 . In conclusion, our findings represent an advance in the field of atomic resolution electron microscopy imaging for quantum materials and devices at LHe temperatures, which can be applied to other commercial side-entry LHe cooling TEM holders.

36 MATERIALS SCIENCE↗