Search NASA⌕ Search

SEARCH · Search NASA

Results for “radiometer calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

A Three-Frequency Feed for Millimeter-Wave Radiometry

A three-frequency millimeter-wave feed horn was developed as part of an advanced component technology task that provides components necessary for higher-frequency radiometers to meet the needs of the Surface Water and Ocean Topography (SWOT) mission. The primary objectives of SWOT are to characterize ocean sub-mesoscale processes on 10-km and larger scales in the global oceans, and to measure the global water storage in inland surface water bodies, including rivers, lakes, reservoirs, and wetlands. In this innovation, the feed provides three separate output ports in the 87-to- 97-GHz, 125-to-135-GHz, and 161-to-183- GHz bands; WR10 for the 90-GHz channel, WR8 for the 130-GHz channel, and WR5 for the 170-GHz channel. These ports are in turn connected to individual radiometer channels that will also demonstrate component technology including new PIN-diode switches and noise diodes for internal calibration integrated into each radiometer front end. For this application, a prime focus feed is required with an edge taper of approximately 20 dB at an illumination angle of 40 deg. A single polarization is provided in each band. Preliminary requirements called for a return loss of better than 15 dB, which is achieved across all three bands. Good pattern symmetry is also obtained throughout all three-frequency bands. This three-frequency broadband millimeter-wave feed also minimizes mass and provides a common focal point for all three millimeter-wave bands.

Hoppe, Daniel J.↗

Some tests of wet tropospheric calibration for the CASA Uno Global Positioning System experiment

Wet tropospheric path delay can be a major error source for Global Positioning System (GPS) geodetic experiments. Strategies for minimizing this error are investigted using data from CASA Uno, the first major GPS experiment in Central and South America, where wet path delays may be both high and variable. Wet path delay calibration using water vapor radiometers (WVRs) and residual delay estimation is compared with strategies where the entire wet path delay is estimated stochastically without prior calibration, using data from a 270-km test baseline in Costa Rica. Both approaches yield centimeter-level baseline repeatability and similar tropospheric estimates, suggesting that WVR calibration is not critical for obtaining high precision results with GPS in the CASA region.

Dixon, T. H.↗

Sea surface temperatures from the scanning multichannel microwave radiometer on Nimbus 7

Because of problems with the design and calibration of the scanning multichannel microwave radiometer (SMMR) on Nimbus 7, sea surface temperature (SST) algorithms had to be developed that corrected for instrument effects. Several stages of this development are reported here. The quality of the SST products from the final version is assessed. Thirty-four months of data have been analyzed; the average SST error is about 1.12 C over the whole globe. The error is smaller in the equatorial region and larger in the northern oceans. The main source of error is due to heating of the SMMR instrument. Specific problems in the design of the instrument are discussed. The details of the ST algorithms are given in an appendix.

Milman, A. S.↗

Validation of the CERES Shortwave Measurements over Desert and Cloud Scenes

The Clouds and the Earth's Radiant Energy System (CERES) broadband shortwave channel, 0.3 - 5 micron, measures atmosphere and surface reflected solar radiation. CERES provides an in-flight tungsten lamp to monitor the shortwave radiometric stability over the lifetime of the instrument. Initial Tropical Rainfall Measurement Mission (TRMM) tungsten calibration results indicate a 0.6% change over the first six months of mission life. The three channel intercomparison technique and the solar diffuser calibration results show shortwave stabilities of 0.2% and 0.3% for the same time period. Current belief is that the tungsten lamp, not the radiometer, has drifted. Radiometers, optics, and onboard calibrators exposed to the harsh space environment often degrade. Independent validation studies based on bright Earth viewing measurements are necessary to support the in-flight filtered calibration results. Instrument measurements of filtered radiances are

Currey, Chris↗

SeaWiFS Postlaunch Technical Report Series: The Fifth Sea-WiFS Intercalibration Round-Robin Experiment (SIRREX-5), July 1996 - Volume 7

This report documents the fifth Sea-viewing Wide Field-of-view Sensor (SeaWiFS) Intercalibration Round-Robin Experiment (SIRREX-5), which was held at the National Institute of Standards and Technology (NIST) on 23-30 July 1996. The agenda for SIRREX-5 was established based on recommendations made during SIRREX-4. For the first time in a SIRREX activity, instrument intercomparisons were performed at field sites, which were near NIST. The goals of SIRREX-5 were to continue the emphasis on training and the implementation of standard measurement practices, investigate the calibration methods and measurement chains in use by the oceanographic community, provide opportunities for discussion, and intercompare selected instruments. As at SIRREX-4, the day was divided between morning lectures and afternoon laboratory exercises. A set of core laboratory sessions were performed: 1) in-water radiant flux measurements; 2) in-air radiant flux measurements; 3) spectral radiance responsivity measurements using the plaque method; 4) device calibration or stability monitoring with portable field sources; and 5) various ancillary exercises designed to illustrate radiometric concepts. Before, during, and after SIRREX-5, NIST calibrated the SIRREX-5 participating radiometers for radiance and irradiance responsivity. The Facility for Automated Spectroradiometric Calibrations (FASCAL) was scheduled for spectral irradiance calibrations for standard lamps during SIRREX-5. Three lamps from the SeaWiFS community were submitted and two were calibrated.

Hooker, Stanford B.↗

GPM Plans for Radiometer Intercalibration

The international Global Precipitation Measurement (GPM) mission led by NASA and JAXA is planned as a multi-radiometer constellation mission. A key mission component is the ability to intercalibrate the Tb from the partner constellation radiometers and create inter-calibrated, mission consistent Tc. One of the enabling strategies for this approach is the launching of a joint NASA/JAXA core satellite which contains a JAXA/NICT provided dual precipitation radar and a NASA provided Microwave Imaging passive radiometer. The observations from these instruments on the core satellite provide the opportunity to develop a transfer reference standard that can then be applied across the partner provided constellation radiometers that enables the creation of mission consistent brightness temperatures. The other aspect of the strategy is the development of a community consensus intercalibration algorithm that will be applied to the Tb observations from partner radiometers and create the best calibrated Tc. Also described is the development of the framework in which the inter-calibration is included in the final algorithm. A part of the latter effort has been the development of a generic, logical structure which can be applied across radiometer types and which guarantees the user community that key information for using Tc properly is recorded. Key

Stocker, Erich Franz↗

Lessons Learned from the Aquarius Radiometer Engineering Model

The Aquarius instrument is a combination microwave radiometer and scatterometer operating in the L-band for the measurement of sea surface salinity (SSS) over the open-ocean. "The Aquarius science goals are to observe and model the processes that relate salinity variations to climatic changes in the global cycling of water and to understand how these variations influence the general ocean circulation. By measuring salinity globally and synoptically every month for 3 years, Aquarius will provide an unprecedented new view of the ocean's role in climate." (http://aquarius.asfc.nasa.gov on Jan. 4, 2007). To launch in 2009, Aquarius will provide 8-day global coverage and monthly-averaged salinity maps at approx.120-km spatial resolution. Because the microwave emissivity of the ocean surface is weakly dependent upon salinity, the Aquarius radiometer remain sufficiently stable to provide accurate salinity measurements. An engineering model (EM) of one radiometer receiver was developed and tested for functionality and performance at NASA's Goddard Space Flight Center. It was tested for long-term stability starting July 27,2006. Two discrepancies where found at the start of testing and a four-month correction process ensued. This paper covers the testing and debugging of the EM radiometer through resolution of the problems. The radiometer is required to have calibration stability of less than or equal to 0.15 K over 7 days. The radiometer is in a three-beam push-broom configuration with each beam being an independent three-state Dicke radiometer (antenna, reference load, and additive noise). Internal noise diodes and reference loads provide periodic and rapid calibration of the receiver. Front-end loss contributions must be corrected as the lossy components are outside the calibration loop. A key design feature for obtaining stability is active thermal control of the front-end lossy components and the RF receiver. The thermal stability is predicted to be about 0.1 C over an orbit and no more than 1 C over a year. The radiometric stability requirement is 0.13 K rms 1 7 days without using temperature corrections. Temperature corrections and post-launch calibration are expected to extend the stability period through the life of the mission.

Piepmeier, Jeffrey↗

Nimbus-7 scanning multichannel microwave radiometer /SMMR/ in-orbit performance appraisal

Calibration and processing techniques enacted during first year of operation of the Nimbus-7 scanning multichannel microwave radiometer (SMMR) are described. It was found that in-orbit calibration was necessary, as was fine-tuning of the geophysical parameter retrieval parameters to account for anomalies such as lower-than-expected polarization differences in ocean radiances. Phase shifts in the scan angles were corrected in order to avoid polarization mixing. Calibration constants to eliminate cross-talk and phase shift effects were established for radiation reflected from the earth, then averaged over data from 300 orbits to fit points on a sine curve to better than 0.2 K accuracy. An iterative approach was determined to be necessary due to signal anomalies caused by antenna dish oscillations. Global ocean and atmosphere parameters used to construct a radiation model of ten latitude bands are presented for use in radiation transfer equations.

Gloersen, P.↗

Electron cyclotron emission measurements and modeling in optically semi-transparent plasma on the HSX stellarator

On the Helically Symmetric Experiment (HSX), electron cyclotron emission (ECE) at the second harmonic of the electron gyrofrequency is measured with a 16-channel heterodyne receiver. An ECE radiometer diagnostic has been calibrated with a broadband frequency source, allowing independent measurements of the electron temperature. The antenna pattern has a significant impact on the measurements, and modeling its effect is necessary to produce an ECE radiation temperature spectrum. Measurements, calibration results, and modeling of the ECE data are presented in this paper. At a relatively high plasma density, HSX plasmas are thermal, and the radiation temperature measured by the radiometer is in good agreement with the electron temperature measured by a Thomson scattering diagnostic. At a relatively low plasma density, the deviation from a Maxwellian distribution is large, and asymmetry in the radiation temperature profile is measured. These measurements are supported by single-pass and multi-pass ray tracing calculations of the electron cyclotron emission using the TRAVIS ray tracing code. Thermal and nonthermal electron populations exist in HSX, and the effect of these populations on the asymmetry in the measured emission is presented.

Cyclotron radiation↗

Calibration of the DSCOVR EPIC Visible and NIR Channels using Multiple LEO Radiometers

The first five years of operation of the Deep Space Climate Observatory (DSCOVR) Earth Polychromatic Imaging Camera (EPIC) at the Lagrange one point have produced results that uniquely complement the data from currently operating low orbit Earth-observing instruments. In this paper we describe an updated unified approach to EPIC calibration. In this approach, calibration coefficients and their trends were obtained by comparing EPIC observations to the measurements from polar orbiting radiometers. In this study L1B reflectances from Moderate Resolution Imaging Spectroradiometer (MODIS) onboard the Aqua and Terra satellites, Multi-angle Imaging Spectroradiometer (MISR) onboard Terra and Visible Infrared Imaging Radiometer (VIIRS) onboard the Suomi National Polar-orbiting Partnership (Suomi NPP) spacecraft were used to infer calibration coefficients for four EPIC visible and near-infrared channels: 443 nm, 551 nm, 680 nm, and 780 nm. EPIC Version three measurements made between June 2015 and August 2020 were used for comparison. The calibration procedure identifies the most homogeneous low Earth orbit radiometer scenes matching scattering angles that are temporarily and spatially collocated with EPIC observations. These scenes are used to determine reflectance to count (R/C) ratios in spectrally analogous channels. Seasonal average R/C ratios were analyzed to obtain EPIC calibration gains and trends. The trends for the full dataset period are not statistically significant except in the 443 nm channel. No significant changes in calibration were found after the instrument’s exit from safe hold in March 2020. The R/C ratios were also used to determine the differences in EPIC gains resulting from separate calibrations: against MODIS Aqua or Terra, as well as against forward or aftward MISR cameras. Statistical tests indicate that the differences between the two datasets are not significant except in the 780 nm channels where Aqua-derived coefficients may be around 2% lower compared to Terra. The dependence of EPIC calibration gains on the instrument scattering angle and on DSCOVR-Earth distance were investigated. Lastly, model Low Earth Orbit (LEO) reflectances calculated to match the EPIC viewing geometry were employed to study how EPIC calibration coefficients depend on EPIC-LEO viewing geometry differences. The effect of LEO and EPIC angular mismatch on calibration was shown to be small.

deep space climate observatory/earth polychromatic↗

Optimum frequencies of passive microwave radiometer for tropospheric path-length correction

Radio-astronomical observations require accurate calibration of tropospheric path length. Such calibration can be achieved by microwave radiometers operating near the 22-GHz water vapor line. However, the performances of current passive microwave radiometers are meteorology-profile dependent. This is due mainly to incorrect frequency combinations and to saturation of brightness temperatures. By properly selecting an optimum frequency pair and removing the saturation effect, the dependency is alleviated and can be further adjusted by surface measurements alone. Hence, a universal calibration equation is applicable to all environmental conditions. Optimum frequency pairs are systematically searched. Simulation analysis indicates that calibration for the tropospheric water-vapor path-length error is better than 0.3 cm at zenith and better than 2 cm for an elevation angle as low as 10 deg.

Wu, S.-C.↗

(abstract) A VLBI Test of Tropospheric Delay Calibration with WVRs

Dual frequency (S/X band) very long baseline interferometry (VLBI) observations were used to test troposphere calibration by water vapor radiometers (WVRs). Comparison of the VLBI and WVR measurements show a statistical agreement (specifically, their structure functions agree) on time scales less than 700 seconds. On longer time scales, VLBI instrumental errors become important. The improvement in VLBI residual delays from WVR calibration was consistent with the measured level of tropospheric fluctuations.

VLBI water vapor radiometers troposphere interfero↗

VNIR and SWIR transfer radiometers developed at NRLM for preflight laboratory cross-calibration

One purpose of preflight laboratory cross-calibration is to avoid the incorrect setting of instrument dynamic range due to calibration mistakes at individual instrument manufacturers. A second purpose is to make corrections of instrument responsivities to have consistent radiance scales among instruments. A third reason is to clarify the state of the art in the absolute responsivity determination of VIS/NIR and SWIF instruments in the EOS era. And fourth is the purpose of improving the preflight calibration accuracy if necessary to meet the EOS requirement.

Ono, A.↗

High-resolution imaging of rain systems with the advanced microwave precipitation radiometer

An advanced Microwave Precipitation Radiometer (AMPR) has been developed and flown in the NASA ER-2-high-altitude aircraft for imaging various atmospheric and surface processes, primarily the internal structure of rain clouds. The AMPR is a scanning four-frequency total power microwave radiometer that is externally calibrated with high-emissivity warm and cold loads. Separate antenna systems allow the sampling of the 10.7- and 19.35-GHz channels at the same spatial resolution, while the 37.1- and 85.5-GHz channels utilize the same multifrequency feedhorn as the 19.35-GHz channel. Spatial resolutions from an aircraft altitude of 20-km range from 0.6 km at 85.5 GHz to 2.8 km at 19.35 and 10.7 GHz. All channels are sampled every 0.6 km in both along-track and cross-track directions, leading to a contiguous sampling pattern of the 85.5-GHz 3-dB beamwidth footprints, 2.3X oversampling of the 37.1-GHz data, and 4.4X oversampling of the 19.35- and 10.7-GHz data. Radiometer temperature sensitivities range from 0.2 to 0.5 C. Details of the system are described, including two different calibration systems and their effect on the data collected. Examples of oceanic rain systems are presented from Florida and the tropical west Pacific that illustrate the wide variety of cloud water, rainwater, and precipitation-size ice combinations that are observable from aircraft altitudes.

Spencer, Roy W.↗

Global Precipitation Measurement (GPM) Mission: Precipitation Processing System (PPS) GPM Mission Gridded Text Products Provide Surface Precipitation Retrievals

In February 2015, the Global Precipitation Measurement (GPM) mission core satellite will complete its first year in space. The core satellite carries a conically scanning microwave imager called the GPM Microwave Imager (GMI), which also has 166 GHz and 183 GHz frequency channels. The GPM core satellite also carries a dual frequency radar (DPR) which operates at Ku frequency, similar to the Tropical Rainfall Measuring Mission (TRMM) Precipitation Radar, and a new Ka frequency. The precipitation processing system (PPS) is producing swath-based instantaneous precipitation retrievals from GMI, both radars including a dual-frequency product, and a combined GMIDPR precipitation retrieval. These level 2 products are written in the HDF5 format and have many additional parameters beyond surface precipitation that are organized into appropriate groups. While these retrieval algorithms were developed prior to launch and are not optimal, these algorithms are producing very creditable retrievals. It is appropriate for a wide group of users to have access to the GPM retrievals. However, for researchers requiring only surface precipitation, these L2 swath products can appear to be very intimidating and they certainly do contain many more variables than the average researcher needs. Some researchers desire only surface retrievals stored in a simple easily accessible format. In response, PPS has begun to produce gridded text based products that contain just the most widely used variables for each instrument (surface rainfall rate, fraction liquid, fraction convective) in a single line for each grid box that contains one or more observations.This paper will describe the gridded data products that are being produced and provide an overview of their content. Currently two types of gridded products are being produced: (1) surface precipitation retrievals from the core satellite instruments GMI, DPR, and combined GMIDPR (2) surface precipitation retrievals for the partner constellation satellites. Both of these gridded products are generated for a.25 degree x.25 degree hourly grid, which are packaged into daily ASCII (American Standard Code for Information Interchange) files that can downloaded from the PPS FTP (File Transfer Protocol) site. To reduce the download size, the files are compressed using the gzip utility.This paper will focus on presenting high-level details about the gridded text product being generated from the instruments on the GPM core satellite. But summary information will also be presented about the partner radiometer gridded product. All retrievals for the partner radiometer are done using the GPROF2014 algorithmusing as input the PPS generated inter-calibrated 1C product for the radiometer.

precipitation↗

Calibration of the visible and near-infrared channels of the NOAA-9 AVHRR using high-altitude aircraft measurements from August 1985 and October 1986

Visible and near infrared wavelength sensors mounted on operational satellites now in use do not have onboard absolute calibration devices. One means of establishing an in-orbit calibration for a satellite sensor is to make simultaneous measurement of a bright, relatively uniform scene along the satellite view vector from a calibrated instrument on board a high altitude aircraft. Herein, aircraft data were recorded over White Sands, New Mexico at satellite overpass time. Comparison of the coincident aircraft and orbiting satellite data for the visible and near infrared wavelength channels of the NOAA-9 Advanced Very High Resolution Radiometer shows that the calibration of the visible channel was unchanged from prelaunch values, but that the near infrared channel has degraded 6 percent by Aug. 1985. By Oct. 1986 the visible channel had degraded 13 percent and the near infrared channel had degraded 19 percent.

Smith, Gilbert R.↗

GPM Mission Overview

The Global Precipitation Measurement (GPM) Mission is an international satellite mission to unify and advance precipitation measurements from a constellation of research and operational sensors to provide "next-generation" precipitation products. Relative to current global rainfall products, GPM data products will be characterized by: (1) more accurate instantaneous precipitation measurements (especially for light rain and cold-season solid/snow precipitation), (2) more frequent sampling by an expanded constellation of microwave radiometers that include operational humidity sounders over land, (3) inter-calibrated microwave brightness temperatures from constellation radiometers within a unified framework, and (4) physical-based precipitation retrievals from constellation radiometers using a common a priori cloud hydrometeor database derived from GPM Core sensor measurements. The cornerstone of the GPM mission is the deployment of a Core Observatory in a unique 65 degree non-Sun-synchronous orbit to serve as a physics observatory and a calibration reference to improve precipitation measurements by a constellation of dedicated and operational passive microwave sensors. The Core Observatory will carry a KulKa-band Dual-frequency Precipitation Radar (DPR) and a multi-channel (10-183 GHz) GPM Microwave Radiometer (GMI). The combined use ofDPR and GMI measurements will place greater constraints on possible solutions to radiometer retrievals to improve the accuracy and consistency of precipitation retrievals from all constellation radiometers. As a science mission with integrated application goals, GPM is designed to (1) advance precipitation measurement capability from space through combined use of active and passive microwave sensors, (2) advance the knowledge of the global water/energy cycle and freshwater availability through better description of the space-time variability of global precipitation, and (3) improve weather, climate, and hydrological prediction capabilities through more accurate and frequent measurements of instantaneous precipitation rates and time-integrated rainfall accumulation. An overview of the GPM mission concept and science activities in the United States, together with an update on international collaborations in radiometer intercalibration and ground validation, will be presented.

Hou, Arthur Y.↗