Earth resources experiment package sensor performance evaluation. Volume 2: S191

An S191 performance summary based on ground testing and orbital operations in terms of pertinent parameters is provided. Additional tasks covering S191 short-wavelength radiometric calibration, data-acquisition camera, and viewfinder tracking system design criteria, radiometric comparison of S190A, S191, and S192, and wavelength calibration data are included as supplemental analyses. Descriptions of techniques employed in the performance analyses are also discussed. Final results of the evaluations in terms of significant performance degradation, sensor and system anomalies, and achieved performance are presented. Conclusions were based on S191 performance and interaction of S191 with the EREP system. Recommendations for additional analyses and improvements in design and operation are presented.

Kenney, G. P.↗

TM Digital Image Products for Applications

LANDSAT-4 Thematic Mapper (TM) digital image products recorded onto computer compatible tapes (CCTs), which were available for internal research purposes prior to August, 1983, are reviewed. The SCROUNGE image processing system at Goddard Space Flight Centr generated in tape formats: (1) raw band-sequential data (CCT-BT), generally used for internal transportation of digital data from one ground processing system to another; (2) calibrated data (CCT-AT), useful for reseachers doing radiometric characterization; and (3) geometrically resampled data (CCT-PT), the final product. The formats represent different steps in the process of producing fully-corrected TM data. The CCT-BT images are re-sequenced from telemetry format to image format, but are uncorrected radiometrically and geometrically. The CCT-AT images had data from two faulty data channels replaced and all data radiometrically calibrated. The CCT-PT images were resampled by cubic convolution procedures to provide a geometrically corrected image using satellite ephemeris and altitude data and scan-mirror correction data. The final product, the CCT-PT, is the one to which all of the radiometric and geometric corrections were applied.

Barker, J. L.↗

Satellite Sensor Requirements for Monitoring Essential Biodiversity Variables of Coastal Ecosystems

The biodiversity and high productivity of coastal terrestrial and aquatic habitats are the foundation for important benefits to human societies around the world. These globally distributed habitats need frequent and broad systematic assessments, but field surveys only cover a small fraction of these areas. Satellite-based sensors can repeatedly record the visible and near-infrared reflectance spectra that contain the absorption, scattering, and fluorescence signatures of functional phytoplankton groups, colored dissolved matter, and particulate matter near the surface ocean, and of biologically structured habitats (floating and emergent vegetation, benthic habitats like coral, seagrass, and algae). These measures can be incorporated into Essential Biodiversity Variables (EBVs), including the distribution, abundance, and traits of groups of species populations, and used to evaluate habitat fragmentation. However, current and planned satellites are not designed to observe the EBVs that change rapidly with extreme tides, salinity, temperatures, storms, pollution, or physical habitat destruction over scales relevant to human activity. Making these observations requires a new generation of satellite sensors able to sample with these combined characteristics: (1) spatial resolution on the order of 30 to 100-m pixels or smaller; (2) spectral resolution on the order of 5 nm in the visible and 10 nm in the short-wave infrared spectrum (or at least two or more bands at 1,030, 1,240, 1,630, 2,125, and/or 2,260 nm) for atmospheric correction and aquatic and vegetation assessments; (3) radiometric quality with signal to noise ratios (SNR) above 800 (relative to signal levels typical of the open ocean), 14-bit digitization, absolute radiometric calibration less than 2%, relative calibration of 0.2%, polarization sensitivity less than 1%, high radiometric stability and linearity, and operations designed to minimize sunglint; and (4) temporal resolution of hours to days. We refer to these combined specifications as H4 imaging. Enabling H4 imaging is vital for the conservation and management of global biodiversity and ecosystem services, including food provisioning and water security. An agile satellite in a 3-d repeat low-Earth orbit could sample 30-km swath images of several hundred coastal habitats daily. Nine H4 satellites would provide weekly coverage of global coastal zones. Such satellite constellations are now feasible and are used in various applications.

aquatic↗

Detector Based Calibration of a Portable Imaging Spectrometer for CLARREO Pathfinder Mission

The Climate Absolute Refractivity and Reflectance Observatory (CLARREO) Pathfinder (CPF) mission is being developed to demonstrate SI-traceable retrievals of reflectance at unprecedented accuracies for global satellite observations. An Independent Calibration of the CPF sensor using the Goddard Laser for Absolute Measurement of Radiance (GLAMR) is planned to allow validation of CPF accuracies. GLAMR is a detector-based calibration system relies on a set of NIST-calibrated transfer radiometers to assess the spectral radiance from the GLAMR sphere source to better than 0.3 % (k=2). The current work describes the calibration of the Solar, Lunar Absolute Reflectance Imaging Spectroradiometer (SOLARIS) that was originally developed as a calibration demonstration system for the CLARREO mission and is now being used to assess the independent calibration being developed for CPF. The methodology for the radiometric calibration of SOLARIS is presented as well as results from the GLAMR-based calibration of SOLARIS. The portability of SOLARIS makes it capable of collecting field measurements of earth scenes and direct solar and lunar irradiance similar to those expected during the on-orbit operation of the CPF sensor. Results of SOLARIS field measurements are presented. The use of SOLARIS in this effort also allows the testing protocols for GLAMR to be improved and the field measurements by SOLARIS build confidence in the error budget for GLAMR calibrations. Results are compared to accepted solar irradiance models to demonstrate accuracy values giving confidence in the error budget for the CLARREO reflectance retrieval.

Aytac, Yigit↗

Processing TES Level-1B Data

TES L1B Subsystem is a computer program that performs several functions for the Tropospheric Emission Spectrometer (TES). The term "L1B" (an abbreviation of "level 1B"), refers to data, specific to the TES, on radiometric calibrated spectral radiances and their corresponding noise equivalent spectral radiances (NESRs), plus ancillary geolocation, quality, and engineering data. The functions performed by TES L1B Subsystem include shear analysis, monitoring of signal levels, detection of ice build-up, and phase correction and radiometric and spectral calibration of TES target data. Also, the program computes NESRs for target spectra, writes scientific TES level-1B data to hierarchical- data-format (HDF) files for public distribution, computes brightness temperatures, and quantifies interpixel signal variability for the purpose of first-order cloud and heterogeneous land screening by the level-2 software summarized in the immediately following article. This program uses an in-house-developed algorithm, called "NUSRT," to correct instrument line-shape factors.

DeBaca, Richard C.↗

Band-to-Band Misregistration of the Images of MODIS Onboard Calibrators and Its Impact on Calibration

The Moderate Resolution Imaging Spectroradiometer (MODIS) instruments aboard Terra and Aqua satellites are radiometrically calibrated on-orbit with a set of onboard calibrators (OBCs), including a solar diffuser, a blackbody, and a space view port through which the detectors can view the dark space. As a whisk-broom scanning spectroradiometer, thirty-six MODIS spectral bands are assembled in the along-scan direction on four focal plane assemblies (FPAs). These bands capture images of the same target sequentially with the motion of a scan mirror. Then the images are coregistered onboard by delaying the appropriate band-dependent amount of time, depending on the band locations on the FPA. While this coregistration mechanismis functioning well for the far-field remote targets such as earth view scenes or the moon, noticeable band-to-band misregistration in the along-scan direction has been observed for near field targets, particularly in OBCs. In this paper, the misregistration phenomenon is presented and analyzed. It is concluded that the root cause of the misregistration is that the rotating element of the instrument, the scan mirror, is displaced from the focus of the telescope primary mirror. The amount of the misregistrationis proportional to the band location on the FPA and is inversely proportional to the distance between the target and the scan mirror. The impact of this misregistration on the calibration of MODIS bands is discussed. In particular, the calculation of the detector gain coefficient m1of bands 8-16 (412 nm 870 nm) is improved by up to 1.5% for Aqua MODIS.

Wang, Zhipeng↗

Multitemporal Cross-Calibration of the Terra MODIS and Landsat 7 ETM+ Reflective Solar Bands

In recent years, there has been a significant increase in the use of remotely sensed data to address global issues. With the open data policy, the data from the Moderate Resolution Imaging Spectroradiometer (MODIS) and Enhanced Thematic Mapper Plus (ETM+) sensors have become a critical component of numerous applications. These two sensors have been operational for more than a decade, providing a rich archive of multispectral imagery for analysis of mutitemporal remote sensing data. This paper focuses on evaluating the radiometric calibration agreement between MODIS and ETM+ using the near-simultaneous and cloud-free image pairs over an African pseudo-invariant calibration site, Libya 4. To account for the combined uncertainties in the top-of-atmosphere (TOA) reflectance due to surface and atmospheric bidirectional reflectance distribution function (BRDF), a semiempirical BRDF model was adopted to normalize the TOA reflectance to the same illumination and viewing geometry. In addition, the spectra from the Earth Observing-1 (EO-1) Hyperion were used to compute spectral corrections between the corresponding MODIS and ETM+ spectral bands. As EO-1 Hyperion scenes were not available for all MODIS and ETM+ data pairs, MODerate resolution atmospheric TRANsmission (MODTRAN) 5.0 simulations were also used to adjust for differences due to the presence or lack of absorption features in some of the bands. A MODIS split-window algorithm provides the atmospheric water vapor column abundance during the overpasses for the MODTRAN simulations. Additionally, the column atmospheric water vapor content during the overpass was retrieved using the MODIS precipitable water vapor product. After performing these adjustments, the radiometric cross-calibration of the two sensors was consistent to within 7%. Some drifts in the response of the bands are evident, with MODIS band 3 being the largest of about 6% over 10 years, a change that will be corrected in Collection 6 MODIS processing.

MODIS↗

TM report

Key spectral, radiometric, and geometric characteristics of the TM sensor are examined. Spectrally, band 5 is slightly wider than specified and its upper edge at 50% of miximum of 1784 nm includes some unintended overlap with water absorption bands. Thermal band 6 is half the expected width. Radiometrically, the TM has extreme linearity and stability in comparison with previous MSS photomultiplier systems. Forward and reverse scans on TM show some unexplained radiometric differences of up to four digital levels. Primary focal plane bands show a monotomic decrease in gain of about 5% in the five months since launch. The relative internal gains of bands 5 and 7 varied with a period of about 60 days and an amplitude of about 6%. Radiometric calibration must be applied before histogram equalization algorithms to preserve radiometric accuracy. Geometrically, channel 4 in band 2 has a smaller modulation transfer function than desired. There is apparent misregistration of .75 pixels along scan and 0.2 pixels across scan.

Barker, J. L.↗

CALIPSO Lidar Calibration at 532 nm: Version 4 Nighttime Algorithm

Data products from the Cloud-Aerosol Lidar with Orthogonal Polarization (CALIOP) on board Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observations (CALIPSO) were recently updated following the implementation of new (version 4) calibration algorithms for all of the level 1 attenuated backscatter measurements. In this work we present the motivation for and the implementation of the version 4 nighttime 532 nm parallel channel calibration. The nighttime 532 nm calibration is the most fundamental calibration of CALIOP data, since all of CALIOP’s other radiometric calibration procedures – i.e., the 532 nm daytime calibration and the 1064 nm calibrations during both nighttime and daytime – depend either directly or indirectly on the 532 nm nighttime calibration. The accuracy of the 532 nm nighttime calibration has been significantly improved by raising the molecular normalization altitude from 30-34 km to 36-39 km to substantially reduce stratospheric aerosol contamination. Due to the greatly reduced molecular number density and consequently reduced signal-to-noise ratio (SNR) at these higher altitudes, the signal is now averaged over a larger number of samples using data from multiple adjacent granules. As well, an enhanced strategy for filtering the radiation-induced noise from high energy particles was adopted. Further, the meteorological model used in the earlier versions has been replaced by the improved MERRA-2 model. An aerosol scattering ratio of 1.01 ± 0.01 is now explicitly used for the calibration altitude. These modifications lead to globally revised calibration coefficients which are, on average, 2-3% lower than in previous data releases. Further, the new calibration procedure is shown to eliminate biases at high altitudes that were present in earlier versions and consequently leads to an improved representation of stratospheric aerosols. Validation results using airborne lidar measurements are also presented. Biases relative to collocated measurements acquired by the Langley Research Center (LaRC) airborne high spectral resolution lidar (HSRL) are reduced from 3.6% ± 2.2% in the version 3 data set to 1.6% ± 2.4 % in the version 4 release.

Jayanta Kar↗

State of The Art Radiometer Standards For NASA'S Earth Observing System

The Multi-Angle Imaging SpectroRadiometer (MISR), to be launched in 1998, is one of five instruments on NASA's first Earth Observing System (EOS) platform. The 3% absolute radiometric calibration requirement is considered challenging, particularly since it must be maintained through the five-year mission life. The Instrument requirements have led to the development of an On-Board Calibrator (OBC) consisting of diffuse panels and photodiode-based radiometric standards.

SpectroRadiometer↗

Measuring Crosstalk in MODIS Spectral Bands On-orbit Using the SRCA

Near-identical MODIS instruments launched on-board the Terra and Aqua spacecraft in 1999 and 2002, respectively. Each MODIS instrument has36 spectral bands covering 0.41 to 14.2μm mounted among four focal plane assemblies, along with a series of on-board calibrators (OBCs) used to characterize the instrument performance on-orbit. One such OBC is the Spectro-radiometric Calibration Assembly (SRCA), which is a multi-function calibrator, able to provide calibration sources to measure spatial, spectral, or radiometric properties of the MODIS bands depending on its configuration. The MODIS instrument performance, including measurements of the signal cross-contamination (crosstalk) between bands, was measured on-orbit during early-mission characterization for both instruments. This crosstalk test used the SRCA in its spatial mode while utilizing the thin slit, which is normally used for spectral calibrations. A similar crosstalk test was recently performed for Terra MODIS. Since the Terra safe mode event in 2016, the PVLWIR bands specifically (6.7-9.7μm) have shown increased influence from crosstalk. The process involved in preparing and performing this crosstalk test is included in this work, as well as the findings from the recent and previous SRCA-based crosstalk characterizations.

MODIS↗

Additional characterization of Libya-4 in support of post-launch vicarious calibration of satellite imagers

Libya-4 (28.55° N and 23.39° E) is one of the most characterized and utilized Pseudo Invariant Calibration Site (PICS) for post-launch radiometer drift monitoring and sensor pair radiometric scaling. Libya-4 is one of the driest and most reflective PICS located in an extensive sand dune region void of any vegetation with an elevation of 118 m. It is positioned near the northeast border with Egypt. With minimal cloud cover and the monthly mean precipitation of ~ 1mm, Libya-4 is one of the temporally, spectrally, and spatially stable CEOS recommended PICS and Cosnefroy et al. 1996 identified sites. The Libya-4 PICS has been extensively used for post-launch radiometric calibration and validation of high-, medium, and low-resolution satellite imagers, including Landsat, MODIS, VIIRS, and Meteosats. The CERES Imager and Geostationary Calibration Group (IGCG) at NASA LaRC utilizes Libya-4 to perform an independent assessment of the radiometric stability of the MODIS and VIIRS L1B products. The site is also used for absolute radiometric scaling between MODIS, VIIRS, and geostationary imagers to ensure consistent cloud and radiative flux retrievals. Multi-year Terra-MODIS, Aqua-MODIS , NPP-VIIRS and Metoesat-7 observations over Libya-4 show very similar TOA reflectance temporal variability. Although, the surface reflectance and atmospheric column varies seasonally, the inter-annual variability of the seasonal cycle should be small. Especially during 2013, the Libya-4 TOA reflectance was found to be greater than usual in all 4 satellite records. Preliminary comparisons with mean wind speed and aerosol optical depth (AOD) indicate that the year 2013 is marked by elevated levels of both conditions. The goal of this study is to tie the Libya-4 visible reflectance inter-annual variability with corresponding meteorological measurements to further improve the characterization of the site.

David R. Doelling↗

Multi-frequency and polarimetric radar backscatter signatures for discrimination between agricultural crops at the Flevoland experimental test site

We describe the calibration and analysis of multi-frequency, multi-polarization radar backscatter signatures over an agriculture test site in the Netherlands. The calibration procedure involved two stages: in the first stage, polarimetric and radiometric calibrations (ignoring noise) were carried out using square-base trihedral corner reflector signatures and some properties of the clutter background. In the second stage, a novel algorithm was used to estimate the noise level in the polarimetric data channels by using the measured signature of an idealized rough surface with Bragg scattering (the ocean in this case). This estimated noise level was then used to correct the measured backscatter signatures from the agriculture fields. We examine the significance of several key parameters extracted from the calibrated and noise-corrected backscatter signatures. The significance is assessed in terms of the ability to uniquely separate among classes from 13 different backscatter types selected from the test site data, including eleven different crops, one forest and one ocean area. Using the parameters with the highest separation for a given class, we use a hierarchical algorithm to classify the entire image. We find that many classes, including ocean, forest, potato, and beet, can be identified with high reliability, while the classes for which no single parameter exhibits sufficient separation have higher rates of misclassification. We expect that modified decision criteria involving simultaneous consideration of several parameters increase performance for these classes.

Freeman, A.↗

Functional test and calibration plan for the Lightning Imaging Sensor

The Lightning Imaging Sensor (LIS) wide field-of-view solid-state camera can measure the global distribution of lightning from LEO, through the use of a narrowband interference filter to detect the neutral O band at 777.4 nm. Prelaunch testing and calibration of the LIS has required three separate laboratory systems; absolute radiometric calibration of the sensor will be furnished over the whole spectral range by a high resolution monochromator and motorized gimbals.

Bergstrom, James W.↗

Calibration: Practical experience with ERS-1

Viewgraphs and discussion of calibration:practical experience with ERS-1 are presented. Topics covered include: radiometric calibration, geometric calibration, phase calibration, and polarimetric calibration. Basic synthetic aperture radar (SAR) measurement parameters are radar backscattering, target position, target speed, and polarization. SAR calibration facilitates quantitative measurements needed to derive geophysical parameters of the area under observation from basic SAR measurements (e.g. soil moisture, biomass, ocean wave energy, ocean currents, ice type, and ice flow).

Louet, Jacques↗

Investigation of passive atmospheric sounding using millimeter and submillimeter wavelength channels

Progress by the Georgia Institute of Technology's Laboratory for Radio-science and Remote Sensing in developing techniques for passive microwave retrieval of water vapor profiles and cloud and precipitation parameters using millimeter and submillimeter wavelength channels is reviewed. Channels of particular interest are in the tropospheric transmission windows at 90, 166, 220, 340, and 410 GHz and centered around the water vapor lines at 183 and 325 GHz. Collectively, these channels have potential application in high-resolution precipitation mapping (e.g., from geosynchronous orbit), remote sensing of cloud and precipitation parameters, including cirrus ice mass, and improved retrieval of water vapor profiles. During the period from January 1, 1994 through June 30, 1994 research activities focussed on calibrating and interpreting data from the Millimeter-Wave Imaging Radiometer (MIR). The MIR was deployed on the NASA ER-2 during the Convective Atmospheric Moisture Experiment (CAMEX, September-October 1993) to obtain the first submillimeter-wave tropospheric imagery of convective precipitations. A 325-GHz radiometer consisted of a submillimeter-wave DSB receiver with three IF channels at +/- 1, 3, and 8.5 GHz, and approximately 14 dB DSB noise figure was successfully operated during these experiments. Activities supported under this grant include a study of the impact of local oscillator reflections from the MIR calibration loads, the development of optimal gain and offset filters for radiometric calibration, and the modeling and interpretation of the MIR 325-GHz data over both clear and cloudy atmospheres. In addition, polarimetric radiometer measurements and modeling for ocean surface and atmospheric cloud-ice studies_were supported.

Gasiewski, Albin J.↗

Characterizations of a KHz Pulsed Laser Detection System

A KHz Pulsed Laser Detection System was developed employing the concept of charge integration with an electrometer, in the NASA Goddard Space Flight Center, Code 618 Calibration Lab for the purpose of using the pulsed lasers for radiometric calibration. Comparing with traditional trans-impedance (current-voltage conversion) detection systems, the prototype of this system consists of a UV-Enhanced Si detector head, a computer controlled shutter system and a synchronized electrometer. The preliminary characterization work employs light sources running in either CW or pulsed mode. We believe this system is able to overcome the saturation issue when a traditional trans-impedance detection system is used with the pulsed laser light source, especially with high peak-power pulsed lasers operating at kilohertz repetition rates (e.g. Ekspla laser or KHz OPO). The charge integration mechanism is also expected to improve the stability of measurements for a pulsed laser light source overcoming the issue of peak-to-peak stability. We will present the system characterizations including signal-to-noise ratio and uncertainty analysis and compare results against traditional trans-impedance detection systems.

Ding, Leibo↗

Characterizations of a KHz Pulsed Laser Detection System

A KHz Pulsed Laser Detection System was developed employing the concept of charge integration with an electrometer, in the NASA Goddard Space Flight Center, Code 618 Calibration Lab for the purpose of using the pulsed lasers for radiometric calibration. Comparing with traditional trans-impedance (current-voltage conversion) detection systems, the prototype of this system consists of a UV-Enhanced Si detector head, a computer controlled shutter system and a synchronized electrometer. The preliminary characterization work employs light sources running in either CW or pulsed mode. We believe this system is able to overcome the saturation issue when a traditional trans-impedance detection system is used with the pulsed laser light source, especially with high peak-power pulsed lasers operating at kilohertz repetition rates (e.g. Ekspla laser or KHz OPO). The charge integration mechanism is also expected to improve the stability of measurements for a pulsed laser light source overcoming the issue of peak-to-peak stability. We will present the system characterizations including signal-to-noise ratio and uncertainty analysis and compare results against traditional trans-impedance detection systems.

Ding, Leibo↗