Search NASA⌕ Search

SEARCH · Search NASA

Results for “radiometric instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Multibeam 1.4-GHz Pushbroom Microwave Radiometer

Airborne prototype of multiple-beam pushbroom microwave radiometer (PBMR) developed to advance radiometric technology necessary for remote sensing of geophysical parameters. Instrument used in several joint Langley Research Center/United States Department of Agriculture soil-moisture flight experiments in Virginia, Texas, and California. Data from experiments used to modify, develop, and verify algorithms used to predict soil moisture from remote-sensing measurements. Image data useful in study of effects of characters of beams on radiometer imaging data.

Lawrence, Roland W.↗

Regional surface fluxes from satellite-derived surface temperatures (AVHRR) and radiosonde profiles

Radiometric surface temperatures, derived from measurements by the AVHRR instrument aboard the NOAA-9 and the NOAA-11 polar orbiting satellites, were used in combination with wind velocity and temperature profiles measured by radiosondes, to calculate surface fluxes of sensible heat. The measurements were made during FIFE, the First ISLSCP (International Satellite Land Surface Climatology Project) Field Experiment, in a hilly tall grass prairie area of northeastern Kansas. The method of calculation was based on turbulent similarity formulations for the atmospheric boundary layer. Good agreement (r = 0.7) was obtained with reference values of sensible heat flux, taken as arithmetric means of measurements with the Bowen ratio method at six ground stations. The values of evaporation (latent heat fluxes), derived from these sensible heat fluxes by means of the energy budget, were also in good agreement (r = 0.94) with the corresponding reference values from the ground stations.

Brutsaert, Wilfried↗

Demonstration of Imaging Fourier Transform Spectrometer (FTS) Performance for Planetary and Geostationary Earth Observing

The combination of massively parallel spatial sampling and accurate spectral radiometry offered by imaging FTS makes it extremely attractive for earth and planetary remote sensing. We constructed a breadboard instrument to help assess the potential for planetary applications of small imaging FTS instruments in the 1 - 5 micrometer range. The results also support definition of the NASA Geostationary Imaging FTS (GIFTS) instrument that will make key meteorological and climate observations from geostationary earth orbit. The Planetary Imaging FTS (PIFTS) breadboard is based on a custom miniaturized Bomen interferometer that uses corner cube reflectors, a wishbone pivoting voice-coil delay scan mechanism, and a laser diode metrology system. The interferometer optical output is measured by a commercial infrared camera procured from Santa Barbara Focalplane. It uses an InSb 128x128 detector array that covers the entire FOV of the instrument when coupled with a 25 mm focal length commercial camera lens. With appropriate lenses and cold filters the instrument can be used from the visible to 5 micrometers. The delay scan is continuous, but slow, covering the maximum range of +/- 0.4 cm in 37.56 sec at a rate of 500 image frames per second. Image exposures are timed to be centered around predicted zero crossings. The design allows for prediction algorithms that account for the most recent fringe rate so that timing jitter produced by scan speed variations can be minimized. Response to a fixed source is linear with exposure time nearly to the point of saturation. Linearity with respect to input variations was demonstrated to within 0.16% using a 3-point blackbody calibration. Imaging of external complex scenes was carried out at low and high spectral resolution. These require full complex calibration to remove background contributions that vary dramatically over the instrument FOV. Testing is continuing to demonstrate the precise radiometric accuracy and noise characteristics.

Revercomb, Henry E.↗

Modeling Studies of the MODIS Solar Diffuser Attenuation Screen and Comparison with On-Orbit Measurements

The MODIS instrument relies on solar calibration to achieve the required radiometric accuracy. This solar calibration occurs as the TERRA spacecraft comes up over the North Pole. The earth underneath the spacecraft is still dark for approximately one minute and the sun is just rising over the earth's north polar regions. During this time the sun moves through about 4 degrees, the scan mirror rotates about 19 times and about 50 frames (exposures) are made of the white solar diffuser. For some of MODIS'S bands the brightness of the screen is reduced, to prevent detector saturation, by means of a pinhole screen, which produces approximately 600 pinhole images of the sun within the field of view of any one detector. Previous attempts at creating a detailed radiometric model of this calibration scenario produced intensity variations on the focal planes with insufficient detail to be useful. The current computational approach produces results, which take into account the motion of the sun and the scan mirror and produces variations, which strongly resemble the observed focal plane intensity variations. The computational approach and results and a comparison with actual observational data are presented.

Waluschka, Eugene↗

Cassini/Huygens Science Instruments, Spacecraft, and Mission

The Cassini spacecraft will take 18 scientific instruments to Saturn. After launch and a seven-year cruise, Cassini will arrive at Saturn and separate into a Saturn orbiter and an atmospheric probe, called Huygens, which will descend to the surface of Titan. The orbiter will orbit the planet for four years, making close flybys of five satellites, including multiple flybys of Titan. Communication with Earth is at X-band; the maximum downlink rate from Saturn is 166 x 10(exp 3) bps. Orbiter instruments are body mounted; the spacecraft must be turned to point some of them toward objects of interest. The orbiter carries 12 instruments. Optical instruments provide imagery and spectrometry. Radar supplies imaging, altimetry, and radiometry. Radio links contribute information about intervening material and gravity fields. Other instruments measure electromagnetic fields and the properties of plasma, energetic particles, and dust particles. The probe is spin stabilized. It returns data via an S-band link to the orbiter. The probe's six instruments include sensors to determine atmospheric physical properties and composition. Radiometric and optical sensors will produce data on thermal balance and obtain images of Titan's atmosphere and surface. Doppler measurements between probe and orbiter will provide wind profiles. Surface sensors will measure impact acceleration, thermal and electrical properties, and, if the surface is liquid, density and refractive index. This design will enable Cassini to determine the composition; the physical, morphological, and geological nature; and the physical and chemical processes of the atmospheres, surfaces, and magnetosphere of the Saturnian system. This paper briefly describes the Cassini mission and spacecraft and, in somewhat more detail, the scientific instruments.

Jaffe, Leonard D.↗

The atmosphere as a research window - Signal or noise

The interpretation of measurements by instruments with FOV that are large enough to contain pronounced radiometric variations is discussed, focusing on the retrieval of cloud properties from satellite radiance measurements. Examples are presented for three retrieval approaches. The use of a physical principle to establish a relationship between the measurement and the desired parameter is shown for cirrus-cloud optical depth and precipitation from passive microwave measurements. Examples of the use of inherent variability of the atmosphere and the statistical character of this variability are the spatial covariance method and the threshold method. Also, two examples using a hybrid of these two methods are presented. It is shown that the natural variability (noise) within the instrument FOV biases the relationship between the measurement and the parameter of interest which would be predicted by simple one-dimensional radiative-transfer theory. It is suggested that the noise of the measurement also contains signal, forming the basis for hybrid methods.

Stephens, Graeme L.↗

Development of techniques and associated instrumentation for high temperature emissivity measurements

The calibrating and testing procedures for the radiometric emittance measurement apparatus are described. Test results are given for the NBS platinum-rhodium standard (SRM No. 1409), the NBS oxidized Kanthal standard, and the oxidized Rene 41 materials. Results indicate that with the platinum-rhodium standard the measurement system compared with the NBS data to within 0.02 for both total and spectral normal emitttance. Data from the Kanthal strip was consistently higher than NBS values. For oxidized Rene 41, no significant changes in as prepared emittance was observed. The emittance was stable for temperatures up to 1150 K.

Cunnington, G. R.↗

On the radiometric stability of the shuttle borne solar backscatter ultraviolet spectrometer

The Shuttle Solar Backscatter Ultraviolet (SSBUV) spectrometer instrument provides regular in-orbit calibration checks on the SBUV/2 ozone/solar irradiance monitoring instruments which are being flown routinely on NOAA operational satellites. The goal of the long-term ozone monitoring program is to detect possible changes in stratospheic ozone with a two sigma accuracy of approximately 1 percent over the course of a decade. This translates into a requirement that the SSBUV instrument be calibrated to a one sigma precision of 1 percent at the wavelengths used for ozone monitoring. We have previously shown that the precision of the SSBUV calibrations is such that we can meet this requirement. Here we discuss SSBUV radiometric sensitivity changes occurring as a result of the first two Space Shuttle flights. Finally, we present and compare SSBUV solar irradiance measurements taken during these flights.

Cebula, Richard P.↗

Initial On-Orbit Spectral Calibration of the PACE Ocean Color Instrument

The NASA Plankton, Aerosol, Cloud, and ocean Ecosystem (PACE) mission Project Science Team has used Ocean Color Instrument (OCI) measurements of Fraunhofer lines in spectra of sunlight reflected by the solar diffuser and measurements of atmospheric absorption bands in cloudtop and ocean spectra to characterize the spectral calibration of OCI on orbit. Multiple lines have been analyzed for both the ultraviolet to visible (UVVIS, 340−607 nm) and visible to near-infrared (VISNIR, 597−897 nm) grating spectrographs. The spectrographs yield hyperspectral observations with 5 nm bandwidths and 0.625 nm sampling intervals. The on-orbit observations have been compared with the prelaunch spectral calibration of OCI performed by the Goddard Laser for Absolute Measurement of Radiance (GLAMR) during thermal vacuum testing to track any changes in the calibration since launch. The calibration analyzed the line positions and strengths for the Fraunhofer lines for each spectrograph by comparing the solar spectra measured by OCI with predicted solar spectra derived from the solar reference spectrum and the BRDF of the solar diffuser, convolved with the OCI relative spectral responses. The calibration also compared the line positions of the atmospheric absorption bands with the model transmissions used by the PACE Project. The line position comparisons show that the root mean square (RMS) spectral difference between the measured and predicted spectra is 0.15 nm, the average spectral shift is 0.062 nm, and the residual spectral dispersion over the wavelength range of the Fraunhofer lines is 0.17 nm. All three estimates of the spectral accuracy of OCI meet the instrument functional requirement of a spectral accuracy of 0.5 nm and are well within the 0.625 nm sampling interval of the data. The line strength comparisons between measured and predicted spectra are essentially the same. These results show that the spectral calibration of OCI on orbit has not drifted since the prelaunch calibration of OCI by GLAMR and that the on-orbit spectral calibration of OCI is stable over time. These results also provide a baseline for monitoring the future spectral performance of OCI on orbit.

Radiometric Calibration↗

Investigation of passive atmospheric sounding using millimeter and submillimeter wavelength channels

Activities within the period from July 1, 1992 through December 31, 1992 by Georgia Tech researchers in millimeter and submillimeter wavelength tropospheric remote sensing have been centered around the calibration of the Millimeter-wave Imaging Radiometer (MIR), preliminary flight data analysis, and preparation for TOGA/COARE. The MIR instrument is a joint project between NASA/GSFC and Georgia Tech. In the current configuration, the MIR has channels at 90, 150, 183(+/-1,3,7), and 220 GHz. Provisions for three additional channels at 325(+/-1,3) and 8 GHz have been made, and a 325-GHz receiver is currently being built by the ZAX Millimeter Wave Corporation for use in the MIR. Past Georgia Tech contributions to the MIR and its related scientific uses have included basic system design studies, performance analyses, and circuit and radiometric load design, in-flight software, and post-flight data display software. The combination of the above millimeter wave and submillimeter wave channels aboard a single well-calibrated instrument will provide unique radiometric data for radiative transfer and cloud and water vapor retrieval studies. A paper by the PI discussing the potential benefits of passive millimeter and submillimeter wave observations for cloud, water vapor and precipitation measurements has recently been published, and is included as an appendix.

Gasiewski, Albin J.↗

Measurements and Calculations of Microwave Radiance and Reflectivity for Storm-Associated Frozen Hydrometeors

During the TEFLUN-B (Texas-Florida under-flights for the Tropical Rainfall Measuring Mission (TRMM)) field experiment of August-September, 1998, a number of ER-2 aircraft flights with a host of microwave instruments were conducted over many convective storms, including some hurricanes, in the coastal region of Florida and Texas. These instruments include MIR (Millimeter-wave Imaging Radiometer), AMPR (Advanced Microwave Precipitation Radiometer), and EDOP (ER-2 Doppler Radar). EDOP is operated at the frequency of 9.7 GHz, while the AMPR and the MIR together give eleven channels of radiometric measurements in the frequency range of 10-340 GHz. The concurrent measurements from these instruments provide unique data sets for studying the details of the microphysics of hydrometeors. Preliminary examination of these data sets shows features that are generally well understood; i.e., radiometric measurements at frequencies <= 37 GHz mainly respond to rain, while those at frequencies >= 150 GHz, to snow and ice clouds above the freezing level. In this paper we present results of comparisons between these measurements and model calculations of brightness temperature and radar reflectivity. For simplicity the analysis is limited to the anvil region of the storms where only frozen hydrometeors are present. Various models of particle size distribution (e.g., Gunn-Marshall, Sekhon-Srivastava, and the Central Equatorial Pacific Experiment (CEPEX)) are examined in the calculations of brightness temperatures at the MIR frequencies and radar reflectivity at the EDOP frequency. Estimation of ice water path is made based on the best agreement between the measurements and calculations of brightness temperature and reflectivity. Problems associated with these analyses and measurement accuracy will be discussed.

Wang, James R.↗

Measurements and Calculations of Microwave Radiance and Reflectivity for Storm-Associated Frozen Hydrometeors

During the TEFLUN-B (Texas-Florida under-flights for TRMM) field experiment of August-September, 1998, a number of ER-2 aircraft flights with a host of microwave instruments were conducted over many convective storms, including some hurricanes, in the coastal region of Florida and Texas. These instruments include MIR (Millimeter-wave Imaging Radiometer), AMPR (Advanced Microwave Precipitation Radiometer), and EDOP (ER-2 Doppler Radar). EDOP is operated at the frequency of 9.7 GHz, while the AMPR and the MIR together give eleven channels of radiometric measurements in the frequency range of 10-340 GHz. The concurrent measurements from these instruments provide unique data sets for studying the details of the microphysics of hydrometeors. Preliminary examination of these data sets shows features that are generally well understood; i.e., radiometric measurements at frequencies less than or equal to 37 GHz mainly respond to rain, while those at frequencies greater than or equal to 150 GHz, to ice particles above the freezing level. Model calculations of brightness temperature and radar reflectivity are performed and results compared with these measurements. For simplicity the analysis is limited to the anvil region of the storms where hydrometeors are predominantly frozen. Only one ice particle size distribution is examined in the calculations of brightness temperature and radar reflectivity in this initial study. Estimation of ice water path is made based on the best agreement between the measurements and calculations of brightness temperature and reflectivity. Problems associated with these analyses and measurement accuracy will be discussed.

Wang, James R.↗

Early Mission Radiometric Performance of NOAA-21 VIIRS Reflective Solar Bands

The Visible Infrared Imaging Radiometer Suite (VIIRS) is a key instrument on the recently launched NOAA-21 (previously JPSS-2) satellite. The VIIRS, like its predecessors on the SNPP and NOAA-20 satellites, provides daily global coverage in 22 spectral bands from 0.41 to 12.0 micrometers. The geometrically and radiometrically calibrated observations are the basis for numerous operational applications and scientific research studies. Fourteen of the 22 bands are reflective solar bands (RSBs), covering wavelengths from 0.41 to 2.25 micrometers. The RSBs were radiometrically calibrated prelaunch and are regularly calibrated on orbit through the onboard solar diffuser (SD) and scheduled lunar observations. The on-orbit SD’s reflectance change is determined by the onboard solar diffuser stability monitor (SDSM). Here, we report our findings on the early mission NOAA-21 VIIRS RSB radiometric performance, and the performance of the SD and the SDSM.

N21 VIIRS↗

Practical aspects of achieving accurate radiometric field measurements

This paper provides practical advice for investigators new to the field of high accuracy radiometric experiments. Sources typically used for calibrating land reflectance measurement instruments are identified, and some special considerations for their use are highlighted. The physical nature of the processes determining the output of these sources is emphasized, and an estimate of the typical calibration accuracies achieved with these sources is described. Several techniques for the validation and verification of instrument characterization are reviewed. Experiment design of the Backscattered Ultraviolet Spectrometer (BUV) and the Earth Radiation Budget Experiment (ERBE) are introduced as successful mission designs for accomplishing high accuracy radiation measurements from space. The goal of this paper is to introduce reasoning developed in other missions to experiments devoted to sensing the earth's surface and near surface.

Guenther, B.↗

Comparison of laboratory calibrations of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) at the beginning and end of the first flight season

Spectral and radiometric calibrations of AVIRIS are described together with changes in instrument characteristics that occurred during the flight season. These changes include detachment of the optical fibers to two of the four AVIRIS spectrometers, degradation in the optical alignment of the spectrometers due to thermally induced and mechanical warpage, and breakage of a thermal blocking filter in one of the spectrometers. Means of improving the instrument are discussed.

Vane, Gregg↗

Evolution of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) flight and ground data processing system

The modifications made to both the AVIRIS instrument and the data processing facility since the instrument made its initial flight in the summer of 1987 are described. Historical development of the data system is discussed and attention is given to enhancements to instrument stability and noise performance. AVIRIS data facility objectives include rapid and automated decommutation and archiving of data, the ability to assess the quality of the data and health of the instrument, and the provision of an automated procedure for applying radiometric corrections to the data and providing responsive processing of data requests from investigators. The modifications described have resulted in an overall radiometric stability of better than 10 percent, with stability of only a few percent during a single flight.

Porter, Wallace M.↗

MODIS-N - Moderate Resolution Imaging Spectrometer-Nadir

The Moderate Resolution Imaging Spectrometer-Nadir (MODIS-N) for the Earth Observing System (EOS) is intended to provide daily global surveys for the atmosphere, the oceans, and the land. To achieve this capability, MODIS-N requires an at-least 2300-km swath width, and provides geometric-instantaneous-fields-of-view (GIFOVs) that are either 856 m, 428 m, or 214 m in size with reference to a 705 km satellite altitude. The 214 m GIFOV may or may not be used depending on total data rate impact assessments traded with science needs. To achieve the data for the multiplicity of science investigations MODIS-N provides nominally 36 spectral bands that are selected for specific locations and bandpasses in the spectral range from the visible to the long wave infrared. Another driver of this instrument combination is the need for long term spectral and radiometric calibration stability. Specific calibration capabilities are to be built into MODIS-N to achieve calibration knowledge over a 5 year operational life.

Weber, Richard R.↗