Search NASA⌕ Search

SEARCH · Search NASA

Results for “record”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Effect of flutter on theoretical bit error rates for digital recording systems.

Tape recorders employed to record and eventually reproduce digital data introduce errors into the data. It is desirable to understand the sources of these errors so that predictions may be made of the resultant error rate. While specific predictions are difficult to apply to whole classes of machines and their respective electronic systems, it is possible to make general predictions which give insight into the problems and processes involved. A heuristic viewpoint is developed for understanding the problems involved in machines and systems that now exist.

Byers, R. A.↗

Mariner 9 infrared interferometer spectrometer (IRIS) reduced data records documentation

The Mariner 9 spacecraft was successfully inserted into orbit around Mars. One of the five instruments on board, an infrared interferometer spectrometer is used to record the thermal emission spectrum of Mars between 200 and 2000 cm/1. The spatial resolution for vertical viewing is a circular area of approximately 110 km diameter for a periapsis height of 1400 km. The total number of calibrated spectra included in the final data set is 21167. The final calibrated thermal emission spectra contained in the reduced data records are reported.

Source record↗

Device for recording the 20 Hz - 200 KHz sound frequency spectrum using teletransmission

The device described consists of two distinct parts: (1) The sound pickup system consisting of the wide-frequency band condenser microphone which contains in the same assembly the frequency-modulated oscillator and the output stage. Being transistorized and small, this system can be easily moved, so that sounds can be picked up even in places that are difficult to reach with larger devices. (2) The receiving and recording part is separate and can be at a great distance from the sound pickup system. This part contains a 72 MHz input stage, a frequency changer that gives an intermediate frequency of 30 MHz and a multichannel analyzer coupled to an oscilloscope and a recorder.

Baciu, I.↗

Measuring probe position recorder

A device which enables a person to record the location of measurements made by a hand held nonconducting probe is described. The hand probe is coupled to a linear potentiometer and a sine-cosine potentiometer by means that varies the output of the linear potentiometer proportional to the distance between the hand probe and the linear potentiometer and that varies the output of the sine-cosine potentiometer proportional to the angular movement of the hand probe relative to the sine-cosine potentiometer. The output of the linear potentiometer is applied directly to one input of the sine-cosine potentiometer and is applied through an inverter to the other input or the sine-cosine potentiometer. The cosine and sine outputs of the sine-cosine potentiometer are applied to the X and Y outputs, respectively, of an X-Y recorder.

Flagge, B.↗

Laser recording on MnBi films

The results of laser recording experiments in which a magnetic field controls the magnetization distribution along Curie-point switched micron-wide tracks are described. These experiments showed that analog as well as digital information may be recorded in this manner.

Lewicki, G.↗

An ultrahigh rate digital tape recorder for spacecraft applications

Spaceborne digital recorders must satisfy the conflicting requirements of maximum data storage of high-rate data (particularly for high-resolution sensor data) and a long life with high reliability (meaning rugged design and moderate head-to-tape speeds). The multitrack longitudinal (fixed head) recorder can successfully resolve this conflict and satisfy both requirements. An evolutionary machine is described which was originally designed to store and reproduce 30 minutes of 39.9-Mb/sec sensor data, for mission lives on the order of one year; newer designs have surpassed these parameters by significant amounts.

Thompson, C. R.↗

Study of multiple hologram recording in lithium niobate

The results of detailed experimental and theoretical considerations relating to multiple hologram recording in lithium niobate are reported. The following problem areas are identified and discussed: (1) the angular selectivity of the stored holograms, (2) interference effects due to the crystal surfaces, (3) beam divergence effects, (4) material recording sensitivity, and (5) scattered light from material inhomogeneities.

Gaylord, T. K.↗

Effects of three activities on annoyance responses to recorded flyovers

Human subjects participated in an experiment in which they were engaged in TV viewing, telephone listening, or reverie (no activity) for a 1/2-hour session. During the session, they were exposed to a series of recorded aircraft sounds at the rate of one flight every 2 minutes. At each session, four levels of flyover noise, separated by 5 db increments were presented several times in a Latin Square balanced sequence. The peak levels of the noisiest flyover in any session was fixed at 95, 90, 85, 75, or 70 db. At the end of the test session, subjects recorded their responses to the aircraft sounds, using a bipolar scale which covered the range from very pleasant to extremely annoying. Responses to aircraft noises are found to be significantly affected by the particular activity in which the subjects are engaged.

Gunn, W. J.↗

Effects of three activities on annoyance responses to recorded flyovers

Subjects participated in an experiment in which they were engaged in TV viewing, telephone listening, or reverie (no activity) for a 1/2-hour session. During the session, they were exposed to a series of recorded aircraft sounds at the rate of one flight every 2 minutes. Within each session, four levels of flyover noise, separated by 5dB increments, were presented several times in a Latin Square balanced sequence. The peak level of the noisiest flyover in any session was fixed at 95, 90, 85, 75, or 70 dBA. At the end of the test session, subjects recorded their responses to the aircraft sounds, using a bipolar scale which covered the range from 'very pleasant' to 'extremely annoying'. Responses to aircraft noises were found to be significantly affected by the particular activity in which the subjects were engaged. Furthermore, not all subjects found the aircraft sounds to be annoying.

Gunn, W. J.↗

Analog data recording on MnBi film

High coercive-force films have reduced sensitivity to wall-domain motion and can record at higher spatial frequencies. Tracks switched in high coercive-force films have track widths independent of applied magnetic field. Upper spatial frequency limit recorded by Curie-point switching in alternating field is greater.

Guisinger, J. E.↗

Computerized tomography using video recorded fluoroscopic images

A computerized tomographic imaging system is examined which employs video-recorded fluoroscopic images as input data. By hooking the video recorder to a digital computer through a suitable interface, such a system permits very rapid construction of tomograms.

Kak, A. C.↗

Study of multiple hologram recording in lithium niobate

The results of a number of theoretical and experimental studies relating to multiple hologram recording in lithium niobate are reported. The analysis of holographic gratings stored in lithium niobate has been extended to cover a more realistic range of physical situations. A new successful dynamic (feedback) theory for describing recording, nondestructive reading, erasure, enhancement, and angular sensitivity has been developed. In addition, the possible architectures of mass data storage systems have been studied.

Gaylord, T. K.↗

Hygroscopic Properties of Magnetic Recording Tape

Relative humidity has been recognized as an important environmental factor in many head-tape interface phenomena such as headwear, friction, staining, and tape shed. Accordingly, the relative humidity is usually specified in many applications of tape use, especially when tape recorders are enclosed in hermetically sealed cases. Normally, the relative humidity is believed regulated by humidification of the fill gas to the specification relative humidity. This study demonstrates that the internal relative humidity in a sealed case is completely controlled by the time-dpendence of the hygroscopic properties of the pack of magnetic recording tape. Differences are found in the hygroscopic properties of the same brand of tape, which apparently result from aging, and which may have an effect on the long-term humidity-regulating behavior in a sealed case, and on the occurrence of head-tape interface phenomena from the long-term use of the tape. Results are presented on the basic hygroscopic properties of magnetic tape, its humidity-regulating behavior in a sealed case, and a theoretical commentary on the relative humidity dependence of head-wear by tape, is included.

Cuddihy, E. F.↗

A CCD integrated circuit for transient recorders

A 50 MHz CCD integrated circuit is described that was developed for use in transient analog signal recorders to sample and time expand transient signals. The integrated circuit achieves an effective 200 MHz sample rate by using four 32 stage peristaltic CCDs to sample the transient signal four times each clock period. Dual frequency, 4 phi clocking is used to sample and time expand the sampled data. The output signals of the four CCDs are multiplexed on chip into a single low frequency output data line. When operated with 50 MHz/165 KHz 4 phi clocks, this circuit has a 200 MHz sample rate, a record length of 640 nanoseconds, a time expansion factor of 303, and overall signal to noise ratio of 40:1. The signal to noise ratio is limited by fixed pattern noise of the four CCDs.

Balch, J. W.↗

Packaging of a large capacity magnetic bubble domain spacecraft recorder

A Solid State Spacecraft Data Recorder (SSDR), based on bubble domain technology, having a storage capacity of 10 to the 8th power bits, was designed and is being tested. The recorder consists of two memory modules each having 32 cells, each cell containing sixteen 100 kilobit serial bubble memory chips. The memory modules are interconnected to a Drive and Control Unit (DCU) module containing four microprocessors, 500 integrated circuits, a RAM core memory and two PROM's. The two memory modules and DCU are housed in individual machined aluminum frames, are stacked in brick fashion and through bolted to a base plate assembly which also houses the power supply.

Becker, F. J.↗

The record of solar and galactic radiations in the ancient lunar regolith and their implications for the early history of the sun and moon

The paper reviews research into the nature and history of the lunar environment, as recorded in rocks and core samples, performed by studying effects produced by the energetic nuclear particles constituting the solar wind, solar flares, and galactic cosmic rays. Results obtained with lunar rocks are discussed which suggest a remarkable constancy of the lunar environment at least over the last several million years. Analyses of lunar core samples are examined which indicate an apparent secular change in the N-15/N-14 ratio with time in solar-wind-related nitrogen, possibly due to greatly enhanced solar flare activity in the past. Lunar and meteoritic breccias are proposed as obvious candidates for extending the radiation record much further back in time, perhaps even close to the beginning of the solar system.

Grozaz, G.↗

A sea-level recorder for tectonic studies

In the past tide gauges have provided valuable information concerning the vertical ground deformation associated with major earthquakes. Although tide-gauge data contains numerous sources of noise, a spacing of less than 40 km between gauges is indicated for a useful study of dilatant behavior, and a spacing of less than 80 km may be adequate for the study of crustal downwarping in island arcs. An inexpensive tide gauge which is designed to provide a continuous record of sea level with a measurement precision of 1 mm is described. Hydraulic filtering is incorporated into the instrument to attenuate daily tides relative to longer period variations of sea level. The instrument is designed to operate from flashlight batteries for a year unattended and to withstand temporary submersion as might be caused by tsunamis. Several of these sea-level recorders have been installed in seismic gaps in the Aleutians and in the Caribbean.

Bilham, R.↗

The application of high density tape recording to image processing

The Image Processing Facility at Goddard Space Flight Center has the requirement to move volumes of digital data (100 billion data bits per day) that exceed the capacity of conventional computer tape. This paper presents the requirements for a high-density digital tape recorder compatible with conventional computer systems. The steps leading to the formulation of these requirements are described. The use and interaction of the recorder with the various elements in the facility are treated. The formulation of the requirements resulted in the selection of a tape transport modified for digital serial-in, serial-out operation. This selection followed a competitive procurement action.

Heffner, P.↗