At least 289 records · Page 16

PyOECP: A flexible open-source software for the measurement and modeling of the dielectric spectrum from the reflection coefficient

We present PyOECP, a Python-based flexible open-source software for estimating and modeling the complex permittivity obtained from the open-ended coaxial probe (OECP) technique. The transformation of the measured reflection coefficient to complex permittivity is performed based on two different models, including the capacitance model and the antenna model. The software library contains dielectric spectra of common reference liquids, which can be used to transform the reflection coefficient into the dielectric spectra. Several Python routines that are commonly employed (e.g., SciPy and NumPy) are only required so that the users can alter the software structure depending on their needs. The modeling algorithm exploits the Markov chain Monte Carlo method for the data regression. The discrete relaxation models can be built by a proper combination of well-known relaxation models. In addition to these models, the electrode polarization, which is a common measurement artifact for interpreting the dielectric spectra, can be incorporated in the modeling algorithm. A continuous relaxation model, which solves the Fredholm integral equation of the first kind (a mathematically ill-posed problem) is also included.

Yoon, Tae-Jun↗

Self-organization in 1 atm DC glows with liquid anodes: current understanding and potential applications

Self-organization refers to the spontaneous generation of spatially or temporally organized patterns in an otherwise disordered system. Self-organization is ubiquitous in plasma physics particularly in the low-pressure regime as observed in astrophysical jets or plasma loaded flux loops that form on the surface of the Sun. In recent times, self-organization in atmospheric pressure plasmas has captured the attention of researchers. Its occurrence has been observed in DBD discharges as well as DC 1 atm glows with liquid electrodes. The mechanism of pattern formation is still not well understood. In this work, we briefly review the current understanding of pattern formation in DC glows with liquid anode, surveying past work, application areas, theories on mechanisms of formation from the context of reaction diffusion systems, current experimental work and computational progress towards predicting pattern formation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Towards a Unified Low-Cost Flow Plate, Flow-Field, PTL Solution for Proton Exchange Membrane Electrolyzers

Proton exchange membrane (PEM) water electrolysis is a highly efficient method for hydrogen production. Research cells typically consist of one proton exchange membrane, two catalyst layers, two porous transport layers, two flow-field plates, and two endplates. In commercial systems, the machined flow-field plates that are employed in research cells are typically replaced by stamped parts or open mesh material solutions to reduce manufacturing cost at scale. Nonetheless, the cell contains about 8 total interfaces: bipolar plate / flow plate material / porous transport medium / electrode / membrane / electrode / porous transport medium / flow plate material / bipolar plate. All these materials and interfaces need to be optimized for maximum performance and efficiency. Reducing the amount of interfaces by combining individual cell components directly benefits the fabrication cost (by reducing the parts count and the needs for surface coatings) and the electrochemical performance (by reducing ohmic losses). We have designed a novel PEM electrolysis cell with a piece of channeled titanium felt functioning as both the anode flow-field and the PTL, referred to as the channeled diffusion layer (CDL). The pores of the felt facilitate both in-plane and through-plane diffusion, ensuring maximum catalyst utilization while also minimizing mass transport loss. The titanium felt can be mass manufactured with existing stamping and forming methods and is therefore a promising candidate to reduce the capital cost of PEM electrolyzers whilst improving hydrogen production efficiency. Experiments conducted with 3mg IrOx/cm2 loading MEAs have shown a approximately 40% boost in peak current by implementing the CDL design. Low catalyst-loading MEAs are being tested in ongoing experiments and their results will be discussed and compared.

08 HYDROGEN↗

Alkaline fuel cell performance investigation

An exploratory experimental fuel cell test program was conducted to investigate the performance characteristics of alkaline laboratory research electrodes. The objective of this work was to establish the effect of temperature, pressure, and concentration upon performance and evaluate candidate cathode configurations having the potential for improved performance. The performance characterization tests provided data to empirically establish the effect of temperature, pressure, and concentration upon performance for cell temperatures up to 300 F and reactant pressures up to 200 psia. Evaluation of five gold alloy cathode catalysts revealed that three doped gold alloys had more that two times the surface areas of reference cathodes and therefore offered the best potential for improved performance.

Martin, R. E.↗

Alkaline fuel cell performance investigation

An exploratory experimental fuel cell test program was conducted to investigate the performance characteristics of alkaline laboratory research electrodes. The objective of this work was to establish the effect of temperature, pressure, and concentration upon performance and evaluate candidate cathode configurations having the potential for improved performance. The performance characterization tests provided data to empirically establish the effect of temperature, pressure, and concentration upon performance for cell temperatures up to 300 F and reactant pressures up to 200 psia. Evaluation of five gold alloy cathode catalysts revealed that three doped gold alloys had more than two times the surface areas of reference cathodes and therefore offered the best potential for improved performance.

Martin, R. E.↗

Acceleration Modes and Transitions in Pulsed Plasma Accelerators

Pulsed plasma accelerators typically operate by storing energy in a capacitor bank and then discharging this energy through a gas, ionizing and accelerating it through the Lorentz body force. Two plasma accelerator types employing this general scheme have typically been studied: the gas-fed pulsed plasma thruster and the quasi-steady magnetoplasmadynamic (MPD) accelerator. The gas-fed pulsed plasma accelerator is generally represented as a completely transient device discharging in approximately 1-10 microseconds. When the capacitor bank is discharged through the gas, a current sheet forms at the breech of the thruster and propagates forward under a j (current density) by B (magnetic field) body force, entraining propellant it encounters. This process is sometimes referred to as detonation-mode acceleration because the current sheet representation approximates that of a strong shock propagating through the gas. Acceleration of the initial current sheet ceases when either the current sheet reaches the end of the device and is ejected or when the current in the circuit reverses, striking a new current sheet at the breech and depriving the initial sheet of additional acceleration. In the quasi-steady MPD accelerator, the pulse is lengthened to approximately 1 millisecond or longer and maintained at an approximately constant level during discharge. The time over which the transient phenomena experienced during startup typically occur is short relative to the overall discharge time, which is now long enough for the plasma to assume a relatively steady-state configuration. The ionized gas flows through a stationary current channel in a manner that is sometimes referred to as the deflagration-mode of operation. The plasma experiences electromagnetic acceleration as it flows through the current channel towards the exit of the device. A device that had a short pulse length but appeared to operate in a plasma acceleration regime different from the gas-fed pulsed plasma accelerators was developed by Cheng, et al. The Coaxial High ENerGy (CHENG) thruster operated on the 10-microseconds timescales of pulsed plasma thrusters, but claimed high thrust density, high efficiency and low electrode erosion rates, which are more consistent with the deflagration mode of acceleration. Separate work on gas-fed pulsed plasma thrusters (PPTs) by Ziemer, et al. identified two separate regimes of performance. The regime at higher mass bits (termed Mode I in that work) possessed relatively constant thrust efficiency (ratio of jet kinetic energy to input electrical energy) as a function of mass bit. In the second regime at very low mass bits (termed Mode II), the efficiency increased with decreasing mass bit. Work by Poehlmann et al. and by Sitaraman and Raja sought to understand the performance of the CHENG thruster and the Mode I / Mode II performance in PPTs by modeling the acceleration using the Hugoniot Relation, with the detonation and deflagration modes representing two distinct sets of solutions to the relevant conservation laws. These works studied the proposal that, depending upon the values of the various controllable parameters, the accelerator would operate in either the detonation or deflagration mode. In the present work, we propose a variation on the explanation for the differences in performance between the various pulsed plasma accelerators. Instead of treating the accelerator as if it were only operating in one mode or the other during a pulse, we model the initial stage of the discharge in all cases as an accelerating current sheet (detonation mode). If the current sheet reaches the exit of the accelerator before the discharge is completed, the acceleration mode transitions to the deflagration mode type found in the quasi-steady MPD thrusters. This modeling method is used to demonstrate that standard gas-fed pulsed plasma accelerators, the CHENG thruster, and the quasi-steady MPD accelerator are variations of the same device, with the overall acceleration of the plasma depending upon the behavior of the plasma discharge during initial transient phase and the relative lengths of the detonation and deflagration modes of operation.

Polzin, Kurt A.↗

PyOECP: A flexible open-source software library for estimating and modeling the complex permittivity based on the open-ended coaxial probe (OECP) technique

Here, we present PyOECP, a Python-based flexible open-source software for estimating and modeling the complex permittivity obtained from the open-ended coaxial probe (OECP) technique. The transformation of the measured reflection coefficient to complex permittivity is performed based on three different methods. The software library contains the dielectric spectra of common reference liquids, which can be used to transform the reflection coefficient into the dielectric spectra. Several Python routines that are commonly employed (e.g., SciPy and NumPy) in the field of science and engineering are required only so that the users can alter the software structure depending on their needs. The modeling algorithm exploits the Markov Chain Monte Carlo method for the data regression. The discrete relaxation models can be built by a proper combination of well-known relaxation models. In addition to these models, electrode polarization, a typical measurement artifact for interpreting dielectric spectra, can be incorporated into the modeling algorithm. A continuous relaxation model, which solves the Fredholm integral equation of the first kind (a mathematically ill-posed problem), is also included. This open-source software enables users to freely adjust the physical parameters to obtain physical insight into their materials under test and will be consistently updated for more accurate measurement and interpretation of dielectric spectra in an automated manner. This work describes the theoretical and mathematical background of the software, lays out the workflow, and validates the software functionality based on both synthetic and empirical data included in the software.

97 MATHEMATICS AND COMPUTING↗

Structure of Layers Formed by [2-(3,6-Disubstituted-9 H -carbazol-9-yl)ethyl]phosphonic Acids on Metal Oxides

[2-(9 H -Carbazol-9-yl)ethyl]phosphonic acid (2PACz) and its derivatives are being used extensively as hole-transport layers in organic and perovskite solar cells due to their ability to modify electrode work function, surface wettability, and in some cases, to improve active-layer adhesion, while minimizing interfacial energy losses. The orientation and coverage of surface modifiers significantly impact these functional properties; however, the detailed structure and packing in these overlayers are challenging to investigate, leading to a lack of understanding of how this structure and packing influence performance and limiting the ability to rationally design molecular modifiers. Here, we investigate monolayers of 2-(9 H -carbazol-9-yl)ethyl phosphonic acid derivatives (from here on referred to as X-2PACz) on indium tin oxide (ITO) and alpha phase aluminum oxide (α-Al 2 O 3 ) using a combination of X-ray photoelectron spectroscopy (XPS), near-edge X-ray absorption fine structure (NEXAFS) spectroscopy, and X-ray reflectivity (XRR). By correlating elemental ratios, molecular orientation, and electron density profiles, we directly quantify surface coverage, layer thickness, and molecular tilt across a series of chemically related monolayers. We find that 2PACz and the X-2PACz derivatives form dense monolayers on α-Al 2 O 3 and ITO, with similar surface coverages on either substrate that are inversely proportional to molecular steric bulk. These surface coverage results indicate that X-2PACz is sterically limited in its monolayer surface packing density, as opposed to site limited. Despite surface packing density differences between molecules, the NEXAFS data show a constant average molecular orientation of 61° to 65° between the plane of the carbazole and the substrate for all the molecules on both substrates. These results increase our general understanding of 2PACz derivatives as they become increasingly useful in high performance solar cells.

NEXAFS↗

Ramp-integration technique for capacitance-type blade-tip clearance measurement

The analysis of a proposed new technique for capacitance type blade tip clearance measurement is presented. The capacitance between the blade tip and a mounted capacitance electrode within a guard ring forms one of the feedback elements of a high speed operational amplifier. The differential equation governing the operational amplifier circuit is formulated and solved for two types of inputs to the amplifier - a constant voltage and a ramp. The resultant solutions shows an output that contains a term that is proportional to the derivative of the product of the input voltage and the time constant of the feedback network. The blade tip clearance capacitance is obtained by subtracting the output of a balancing reference channel followed by integration. The proposed sampled data algorithm corrects the environmental effects and varying rotor speeds on-line, making the system suitable for turbine instrumentation. System requirements, block diagrams, and typical application are included.

Sarma, G. R.↗

Ramp-integration technique for capacitance-type blade-tip clearance measurement

The analysis of a proposed new technique for capacitance type blade tip clearance measurement is presented. The capacitance between the blade tip and a mounted capacitance electrode within a guard ring forms one of the feedback elements of a high speed operational amplifier. The differential equation governing the operational amplifier circuit is formulated and solved for two types of inputs to the amplifier - a constant voltage and a ramp. The resultant solution shows an output that contains a term that is proportional to the derivative of the product of the input voltage and the time constant of the feedback network. The blade tip clearance capacitance is obtained by subtracting the output of a balancing reference channel followed by integration. The proposed sampled data algorithm corrects for environmental effects and varying rotor speeds on-line, making the system suitable for turbine instrumentation. System requirements, block diagrams, and a typical application are included.

Sarma, Garimella R.↗

Effects Of Electric Field On Hydrocarbon-Fueled Flames

It has been observed that flames are susceptible to electric fields that are much weaker than the breakdown field strength of the flame gases. When an external electric field is imposed on a flame, the ions generated in the flame reaction zone drift in the direction of the electric forces exerted on them. The moving ions collide with the neutral species and change the velocity distribution in the affected region. This is often referred to as ionic wind effect. In addition, the removal of ions from the flame reaction zone can alter the chemical reaction pathway of the flame. On the other hand, the presence of space charges carried by moving ions affects the electric field distribution. As a result, the flame often changes its shape, location and color once an external electric field is applied. The interplay between the flame movement and the change of electric field makes it difficult to determine the flame location for a given configuration of electrodes and fuel source. In normal gravity, the buoyancy-induced flow often complicates the problem and hinders detailed study of the interaction between the flame and the electric field. In this work, the microgravity environment established at the 2.2 Second Drop Tower at the NASA Glenn Research Center is utilized to effectively remove the buoyant acceleration. The interaction between the flame and the electric field is studied in a one-dimensional domain. A specially designed electrode makes flame current measurements possible; thus, the mobility of ions, ion density, and ionic wind effect can be evaluated.

Yuan, Z.-G.↗

Distributed Capacitive Sensor for Sample Mass Measurement

Previous robotic sample return missions lacked in situ sample verification/ quantity measurement instruments. Therefore, the outcome of the mission remained unclear until spacecraft return. In situ sample verification systems such as this Distributed Capacitive (DisC) sensor would enable an unmanned spacecraft system to re-attempt the sample acquisition procedures until the capture of desired sample quantity is positively confirmed, thereby maximizing the prospect for scientific reward. The DisC device contains a 10-cm-diameter pressure-sensitive elastic membrane placed at the bottom of a sample canister. The membrane deforms under the weight of accumulating planetary sample. The membrane is positioned in close proximity to an opposing rigid substrate with a narrow gap. The deformation of the membrane makes the gap narrower, resulting in increased capacitance between the two parallel plates (elastic membrane and rigid substrate). C-V conversion circuits on a nearby PCB (printed circuit board) provide capacitance readout via LVDS (low-voltage differential signaling) interface. The capacitance method was chosen over other potential approaches such as the piezoelectric method because of its inherent temperature stability advantage. A reference capacitor and temperature sensor are embedded in the system to compensate for temperature effects. The pressure-sensitive membranes are aluminum 6061, stainless steel (SUS) 403, and metal-coated polyimide plates. The thicknesses of these membranes range from 250 to 500 m. The rigid substrate is made with a 1- to 2-mm-thick wafer of one of the following materials depending on the application requirements glass, silicon, polyimide, PCB substrate. The glass substrate is fabricated by a microelectromechanical systems (MEMS) fabrication approach. Several concentric electrode patterns are printed on the substrate. The initial gap between the two plates, 100 m, is defined by a silicon spacer ring that is anodically bonded to the glass substrate. The fabricated proof-of-concept devices have successfully demonstrated tens to hundreds of picofarads of capacitance change when a simulated sample (100 g to 500 g) is placed on the membrane.

Toda, Risaku↗

Piezoelectrically forced vibrations of electroded doubly rotated quartz plates by state space method

The purpose of this investigation is to develop an analytical method to study the vibration characteristics of piezoelectrically forced quartz plates. The procedure can be summarized as follows. The three dimensional governing equations of piezoelectricity, the constitutive equations and the strain-displacement relationships are used in deriving the final equations. For this purpose, a state vector consisting of stresses and displacements are chosen and the above equations are manipulated to obtain the projection of the derivative of the state vector with respect to the thickness coordinate on to the state vector itself. The solution to the state vector at any plane is then easily obtained in a closed form in terms of the state vector quantities at a reference plane. To simplify the analysis, simple thickness mode and plane strain approximations are used.

Chander, R.↗

ASTROS - High-performance CCD tracker for spacecraft

The architecture, capabilities, and testing of the Advanced Star and Target Reference Optical Sensor (ASTROS) I and II are described. The ASTROS I tracker is to be utilized for a UV telescope experiment on a Shuttle flight and is capable of measuring pointing errors of 1.5 microrad, and the ASTROS II tracker is being developed for the Mariner Mark II spacecraft to perform tracking, guiding, and optical navigation functions. The requirements for the two trackers are compared. Consideration is given to star and target tracking, optical navigation, and mass and power constraints. The compositions of the trackers, in particular the sensor, electrode drives, amplifiers and signal clamp, video signal processor, control and timing generator, memories, microprocessor, and interface, are examined.

Dennison, E. W.↗

Design of the Electromagnetic Particle Injector (EPI) for Tokamak Deployment

Both predicting and controlling disruptions are critical and urgent issues for ITER as some disruptions with a short warning time may be unavoidable. For these cases, a rapid response disruption mitigation system (DMS) referred to as the electromagnetic particle injector (EPI) is being developed. The primary advantages of the EPI are its fast response time and high velocity, which have been demonstrated in offline experiments (Raman et al., 2021). The EPI is capable of accelerating a metallic sabot electromagnetically using a rail gun to the required velocities ( > 2 km/s) within 2 ms. Two high-field racetrack magnets able to generate fields over 2 T are positioned above and below the rails to permit high velocity at low rail currents, a requirement to minimize electrode erosion. At the end of the acceleration phase, a sabot capture mechanism retains the spent sabot inside the vacuum chamber that houses the EPI. At this point, it releases well-defined microspheres, or a shell pellet, of a radiative payload into the disrupting plasma. A remotely operated sabot loading system positioned behind the injector contains several pre-equipped sabots that can be loaded by an operator from the tokamak control room. The injector is interfaced to the tokamak through a guide tube attached to the front of the EPI vacuum chamber. Finally, the advantages of the EPI system over other DMSs under consideration are described in conjunction with the details of an EPI system designed for near-term test on an existing large tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Wearable radio-frequency sensing of respiratory rate, respiratory volume, and heart rate

Abstract Many health diagnostic systems demand noninvasive sensing of respiratory rate, respiratory volume, and heart rate with high user comfort. Previous methods often require multiple sensors, including skin-touch electrodes, tension belts, or nearby off-the-body readers, and hence are uncomfortable or inconvenient. This paper presents an over-clothing wearable radio-frequency sensor study, conducted on 20 healthy participants (14 females) performing voluntary breathing exercises in various postures. Two prototype sensors were placed on the participants, one close to the heart and the other below the xiphoid process to couple to the motion from heart, lungs and diaphragm, by the near-field coherent sensing principle. We can achieve a satisfactory correlation of our sensor with the reference devices for the three vital signs: heart rate ( r = 0.95), respiratory rate ( r = 0.93) and respiratory volume ( r = 0.84). We also detected voluntary breath-hold periods with an accuracy of 96%. Further, the participants performed a breathing exercise by contracting abdomen inwards while holding breath, leading to paradoxical outward thorax motion under the isovolumetric condition, which was detected with an accuracy of 83%.

60 APPLIED LIFE SCIENCES↗

Design of an Online Electrochemical Mass Spectrometry System to Study Gas Evolution from Cells with Lean and Volatile Electrolytes

Gas evolution in high-energy Li-ion batteries remains a pervasive problem for a multitude of chemistries, jeopardizing the electrochemical performance and safety for consumers of electric vehicles. Many electrode–electrolyte degradation processes evolve gasses that may be detected in-situ with online electrochemical mass spectrometry (OEMS). In this work, details are provided for the setup and validation of an OEMS system that operates well under lean and volatile electrolyte conditions. Quite notably, the OEMS cells with only 40 µL of electrolyte and intermittent headspace sampling exhibit comparable electrochemical performance to flooded coin-cells. It is demonstrated that the onset time, shape, and magnitude of the gas evolution profiles calculated from mass spectrometer measurements match well to a known pressure reference through the use of an empirically determined fraction of removal. The off-gassing characteristics from a set of layered-oxide materials, NMC532, NMC811, and LNO, are used to further validate the OEMS setup against the literature. It is shown that many of the features present in the OEMS curves for equivalent systems from other groups are captured by this OEMS system. Finally, at an upper cut-off voltage of 4.4 V, LNO exhibits an intense release of CO 2 , O 2 , and CO gas relative to NMC532 and NMC811.

25 ENERGY STORAGE↗

Electrodes for the thermionic converters, phase 2 - 3

The characteristics of electrodes for thermionic converters are discussed. A metal/ceramic Marchuk tube was constructed and operated with a quiescent cesium vapor plasma corresponding to cesium liquid reservoir temperatures from 376 to 427 K. The work function characteristics of tantalum test emitters coated with anodic films were measured to evaluate the applicability of the materials as the collector surface in a plasma mode thermionic converter. Work function minimum values between 1.4 and 1.5 electron volts were observed. The effect of the electronegative surface layers was partially obscured by additive vapor impurities detected by the clean tantalum reference emitter.

Desteese, J. G.↗