Search NASA⌕ Search

SEARCH · Search NASA

Results for “refractivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Real-time measurement of parametric influences on the refractive index and length changes in silica optical fibers

In this paper, we present a simple cascaded Fabry-Perot interferometer (FPI) that can be used to measure in real-time the refractive index (RI) and length variation in silica optical fibers caused due to external physical parameters, such as temperature, strain, and radiation. As a proof-of-concept, we experimentally demonstrate real-time monitoring of temperature effects on the RI and length and measure the thermo-optic coefficient (TOC) and thermal expansion coefficient (TEC) by using the cascaded FPI within a temperature range of 21–486°C. The experimental results provide a TEC of 5.53 × 10 −7 /°C and TOC of 4.28 × 10 −6 /°C within the specified temperature range. Such a simple cascaded FPI structure will enable the design of optical sensors to correct for measurement errors by understanding the change in RI and length of optical fiber caused by environment parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Refractive axicon for X-ray microscopy applications: design, optimization, and experiment

In a full-field transmission X-ray microscopy (TXM) setup, a condenser X-ray optical element is used to illuminate the sample by condensing the X-ray beam delivered by the synchrotron storage ring. On-going and future upgrades of synchrotron facilities to diffraction-limited storage rings will pose new challenges to these TXM setups, such as much smaller X-ray beams on the condenser. Here, we demonstrate that a refractive axicon can be used as an X-ray beam shaper to match the ring-shaped aperture of the condenser. Aiming at more efficient use of the incoming X-ray intensity, we explore several axicon designs both analytically and with numerical simulations. The axicons were produced by two-photon polymerization 3D printing on thin silicon nitride membrane substrates. The first characterization of the axicon was carried out at the TOMCAT beamline of the Swiss Light Source (Switzerland).

47 OTHER INSTRUMENTATION↗

Nonlinear refraction and absorption properties of optical materials for high-peak-power long-wave-infrared lasers

Optical materials transparent in the CO 2 laser wavelength range have been evaluated regarding their suitability for components in ultrashort-pulse (≤ a few ps), high-peak-power (≥ a few TW) long-wave infrared (LWIR) lasers. We provide values for the nonlinear refractive index ( n 2 ) for seventeen materials, and onsets for nonlinear absorption for eleven materials. Characterizations were performed using a 2 ps laser pulse at λ =9.2 μ m. This paper methodically presents the newly acquired data in conjunction with existing literature on linear optical properties, establishing it as a comprehensive reference for designing high-peak-power LWIR laser systems.

43 PARTICLE ACCELERATORS↗

High speed laser-induced refractive index change in ophthalmic HEMA hydrogel using a line focus

Laser-induced refractive index change (LIRIC) techniques typically focus femtosecond laser pulses to a tight spot to achieve the high intensities required to alter ophthalmic materials. A line-focus implementation using 800 nm pulses at 1 kHz repetition rate has been shown to greatly increase the effective writing speed of the process, but the high pulse energies used led to nonlinear propagation effects, presenting challenges for the fabrication of ophthalmic correctors. By taking advantage of the lower effective order of multiphoton absorption for 514 nm pulses, power levels may be reduced, allowing overlapped pulse writing. We demonstrate that this allows high-quality phase bars and devices to be made at high speeds.

Manning, Zachary A. [University of Rochester, NY (↗

Temperature dependent index of refraction compensation and radiation resistance in monolithic optical systems

Monolithic catadioptric optical systems are susceptible to defocus errors caused by inhomogeneous temperature within the glass material due to temperature dependent index of refraction. This invention discloses methods to mitigate these errors using tuned materials in its optical design coupled with active optical radiative heating to provide optimal performance and includes methods to enhance radiation resistance.

36 MATERIALS SCIENCE↗

Computational Determination of the Refractive Index of TATB, LLM-105, β-HMX, & α-RDX

In this study, we use Materials Studio CASTEP, an ab initio quantum mechanical (QM) program employing density functional theory (DFT), to compute the refractive index (RI) of solid energetic materials, specifically, PETN (tetragonal phase), TATB, LLM-105, β-HMX, and α-RDX. The use of quantum mechanical DFT methods affords the investigation of the optical mate rial properties of a system without the need for any experimental input. The RI values of PETN and TATB have been experimentally determined previously and are compared here to the QM derived RI values as validation of the theoretical approach in determining material optical proper ties. To date, experimental measurements to determine the RI values for LLM-105 have yet to be determined. This fact obviates the need to determine LLM-105 RI values using quantum mechanical means.

36 MATERIALS SCIENCE↗

Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems

Engineering cellular metabolism for targeted biosynthesis can require extensive design-build-test-learn (DBTL) cycles as the engineer works around the cell's survival requirements. Alternatively, carrying out DBTL cycles in cell-free environments can accelerate this process and alleviate concerns with host compatibility. A promising approach to cell-free metabolic engineering (CFME) leverages metabolically active crude cell extracts as platforms for biomanufacturing and for rapidly discovering and prototyping modified proteins and pathways. Realizing these capabilities and optimizing CFME performance requires methods to characterize the metabolome of lysate-based cell-free platforms. That is, analytical tools are necessary for monitoring improvements in targeted metabolite conversions and in elucidating alterations to metabolite flux when manipulating lysate metabolism. In this work, metabolite analyses using high-performance liquid chromatography (HPLC) coupled with either optical or mass spectrometric detection were applied to characterize metabolite production and flux in E. coli S30 lysates. Specifically, this report describes the preparation of samples from CFME lysates for HPLC analyses using refractive index detection (RID) to quantify the generation of central metabolic intermediates and by-products in the conversion of low-cost substrates (i.e., glucose) to various high-value products. The analysis of metabolite conversion in CFME reactions fed with 13 C-labeled glucose through reversed-phase liquid chromatography coupled to tandem mass spectrometry (MS/MS), a powerful tool for characterizing specific metabolite yields and lysate metabolic flux from starting materials, is also presented. Altogether, applying these analytical methods to CFME lysate metabolism enables the advancement of these systems as alternative platforms for executing faster or novel metabolic engineering tasks.

59 BASIC BIOLOGICAL SCIENCES↗

First Temperature Profile of a Stellar Flare Using Differential Chromatic Refraction

We present the first derivation of a stellar flare temperature profile from single-band photometry. Stellar flare DWF 030225.574−545707.45129 was detected in 2015 by the Dark Energy Camera as part of the Deeper, Wider, Faster program. The brightness (Δm g = −6.12) of this flare, combined with the high air mass (1.45 ≲ X ≲ 1.75) and blue filter (DES g, 398–548 nm) in which it was observed, provided ideal conditions to measure the zenithward apparent motion of the source due to differential chromatic refraction (DCR) and, from that, infer the effective temperature of the event. We model the flare’s spectral energy distribution as a blackbody to produce the constraints on flare temperature and geometric properties derived from single-band photometry. We additionally demonstrate how simplistic assumptions on the flaring spectrum, as well as on the evolution of flare geometry, can result in solutions that overestimate the effective temperature. Exploiting DCR enables studying chromatic phenomena with ground-based astrophysical surveys, and stellar flares on M dwarfs are a particularly enticing target for such studies due to their ubiquity across the sky and the heightened color contrast between their red quiescent photospheres and the blue flare emission. Our novel method will enable similar temperature constraints for a large sample of objects in upcoming photometric surveys like the Vera C. Rubin Legacy Survey of Space and Time.

Clarke, Riley W. [University of Delaware, Newark, ↗