Search NASA⌕ Search

SEARCH · Search NASA

Results for “relative humidity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

A Bimodal Diagnostic Cloud Fraction Parameterization. Part I: Motivating Analysis and Scheme Description

Cloud fraction parameterizations are beneficial to regional, convection-permitting numerical weather prediction. For its operational regional midlatitude forecasts, the Met Office uses a diagnostic cloud fraction scheme that relies on a unimodal, symmetric subgrid saturation-departure distribution. This scheme has been shown before to underestimate cloud cover and hence an empirically based bias correction is used operationally to improve performance. This first of a series of two papers proposes a new diagnostic cloud scheme as a more physically based alternative to the operational bias correction. The new cloud scheme identifies entrainment zones associated with strong temperature inversions. Additionally, for model grid boxes located in this entrainment zone, collocated moist and dry Gaussian modes are used to represent the subgrid conditions. The mean and width of the Gaussian modes, inferred from the turbulent characteristics, are then used to diagnose cloud water content and cloud fraction. It is shown that the new scheme diagnoses enhanced cloud cover for a given gridbox mean humidity, similar to the current operational approach. It does so, however, in a physically meaningful way. Using observed aircraft data and ground-based retrievals over the southern Great Plains in the United States, it is shown that the new scheme improves the relation between cloud fraction, relative humidity, and liquid water content. An emergent property of the scheme is its ability to infer skewed and bimodal distributions from the large-scale state that qualitatively compare well against observations. A detailed evaluation and resolution sensitivity study will follow in Part II.

54 ENVIRONMENTAL SCIENCES↗

The Effects of Morphology and Hydration on Anion Transport in Self-Assembled Nanoporous Membranes

Ordered nanoporous polymer membranes offer opportunities for systematically probing the mechanisms of ion transport under confinement and for realizing useful materials for electrochemical devices. Here, we examine the impact of morphology and ion hydration on the transport of hydroxide and bromide anions in nanostructured polymer membranes with 1 nm scale pores. We use aqueous lyotropic self-assembly of an amphiphilic monomer, with a polymerizable surfactant to create direct hexagonal (H I ) and gyroid mesophases. UV-induced cross-linking leads to the formation of nanoporous polymers with water continuous channels. The membranes are mechanically robust and chemically durable, resisting degradation during extended exposure to 1 M NaOH solutions. We use a combination of electrochemical impedance spectroscopy, pulsed-field gradient NMR spectroscopy, and molecular simulations to elucidate anion and water transport. The as-prepared hexagonal systems display higher conductivity and lower activation energies for both anions relative to the gyroid system. When compared at equivalent hydration, however, gyroid and hexagonal membranes show similar activation energies, with nearly identical conductivities at ambient temperatures. Both ionic conductivity and water diffusivity increase with increasing hydration. Here, the water uptake as a function of relative humidity for the hexagonal and gyroid mesophases ultimately dictates the water diffusion and magnitude of the ionic conductivity, with the hexagonal system showing overall higher capacity for hydration and thus faster ion transport. The durability of these materials under aggressive alkaline conditions and their relatively high hydroxide ion conductivity suggest that these nanostructured polymers could be of interest as membranes for alkaline fuel cells.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Self-Aligned Fluorinated-Organic Ligand for Boosting the Performance of Perovskite Solar Cells

Surface passivation is evident to be one of the most efficient approaches to achieve high efficiency with superior stability of perovskite solar cells (PeSCs). However, most previous approaches to surface passivation involve adding an additional coating process either before or after perovskite film fabrication, thereby introducing an extra processing step and significantly increasing production costs. Here, a simple yet novel one-step interfacial passivation approach was implemented by utilizing the self-aligning properties of fluorinated organic ligands (F4TmI) within a perovskite precursor solution. The inherent propensity of the ligand to spontaneously anchor onto the surface of perovskite guides the crystallization process of perovskites, thus largely enhancing the device performance and humidity stability. The optimized F4TmI-based devices achieved an efficiency of 21.1%, surpassing that of the control (19.8%). Furthermore, the device stability significantly improved after the incorporation of F4TmI, maintaining 78.9 and 95.1% of its initial efficiency after aging at 60 °C and 60% relative humidity, respectively, for 330 h.

14 SOLAR ENERGY↗

Evaluating cloud liquid detection against Cloudnet using cloud radar Doppler spectra in a pre-trained artificial neural network

Detection of liquid-containing cloud layers in thick mixed-phase clouds or multi-layer cloud situations from ground-based remote-sensing instruments still poses observational challenges, yet improvements are crucial since the existence of multi-layer liquid layers in mixed-phase cloud situations influences cloud radiative effects, cloud lifetime, and precipitation formation processes. Hydrometeor target classifications such as from Cloudnet that require a lidar signal for the classification of liquid are limited to the maximum height of lidar signal penetration and thus often lead to underestimations of liquid-containing cloud layers. Here we evaluate the Cloudnet liquid detection against the approach of Luke et al. (2010) which extracts morphological features in cloud-penetrating cloud radar Doppler spectra measurements in an artificial neural network (ANN) approach to classify liquid beyond full lidar signal attenuation based on the simulation of the two lidar parameters particle backscatter coefficient and particle depolarization ratio. We show that the ANN of Luke et al. (2010) which was trained under Arctic conditions can successfully be applied to observations at the mid-latitudes obtained during the 7-week-long ACCEPT field experiment in Cabauw, the Netherlands, in 2014. In a sensitivity study covering the whole duration of the ACCEPT campaign, different liquid-detection thresholds for ANN-predicted lidar variables are applied and evaluated against the Cloudnet target classification. Independent validation of the liquid mask from the standard Cloudnet target classification against the ANN-based technique is realized by comparisons to observations of microwave radiometer liquid-water path, ceilometer liquid-layer base altitude, and radiosonde relative humidity. In addition, a case-study comparison against the cloud feature mask detected by the space-borne lidar aboard the CALIPSO satellite is presented. Three conclusions were drawn from the investigation. First, it was found that the threshold selection criteria of liquid-related lidar backscatter and depolarization alone control the liquid detection considerably. Second, all threshold values used in the ANN framework were found to outperform the Cloudnet target classification for deep or multi-layer cloud situations where the lidar signal is fully attenuated within low liquid layers and the cloud radar is able to detect the microphysical fingerprint of liquid in higher cloud layers. Third, if lidar data are available, Cloudnet is at least as good as the ANN. The times when Cloudnet outperforms the ANN in liquid detections are often associated with situations where cloud dynamics smear the imprint of cloud microphysics on the radar Doppler spectra.

54 ENVIRONMENTAL SCIENCES↗

A Custom High-Throughput Optical Mapping Instrument (OMI) for Accelerated Stress Testing of PV Module Materials

The performance and integrity of photovoltaic (PV) modules and materials may be assessed through optical characterizations. We have developed a custom Optical Mapping Instrument (OMI) to improve measurement throughput time, facilitate automated measurements, and obtain spatial information relative to commercial benchtop spectrophotometer instruments. Both the key components and the methods used to improve the measurements are described. The measurement precision for the OMI is benchmarked for hemispherical transmittance relative to a previous round-robin study for commercial spectrophotometers. Example mapping measurements and their implications are given for specimens from other studies, including: (1) the depletion of the UV absorber is revealed for specimens beyond a certain size after standardized artificial ultraviolet (UV) weathering, (2) an optical degradation by internal haze formation is confirmed following Damp Heat (85°C/85% relative humidity) testing, (3) the better uniformity of the wear pattern for falling sand abrasion is used to select the DIN 52348 fixture over the ASTM D968 fixture, and (4) the local (millimeter-scale) heterogeneity of surface contamination in the soiling-prone location of Dubai relative to Kuwait. The results of the UV study have already been used to improve the standardized weathering of encapsulants. The example for Damp Heat testing is given to increase awareness of a degradation believed to be ubiquitously occurring in safety and design-type qualification testing of PV modules.

41 EE - Solar Energy Technologies Office (EE-4S)↗

A Custom High-Throughput Optical Mapping Instrument for Accelerated Stress Testing of PV Module Materials

The performance and integrity of photovoltaic (PV) modules and materials may be assessed through optical characterizations. We have developed a custom optical mapping instrument (OMI) to improve measurement throughput time, facilitate automated measurements, allow for localized specimen examination, obtain spatial information relative to commercial benchtop spectrophotometer instruments, and provide automated data analysis. Both the key components and the methods used to improve the measurements are described. The measurement precision for the OMI is benchmarked for hemispherical transmittance relative to a previous round-robin study for commercial spectrophotometers. In addition to the unique instrument developed in this study, new insights have emerged from the examination of specimens from previous experiments, including: the depletion of the UV absorber is revealed for specimens beyond a certain size after artificial ultraviolet (UV) weathering; an optical degradation by internal haze formation is confirmed following Damp Heat (85 °C/85% relative humidity) testing; the better uniformity of the wear pattern for falling sand abrasion is used to select the DIN 52348 fixture over the ASTM D968 fixture; and the greater local (in the order of millimeters) heterogeneity of surface contamination in the soiling-prone location of Dubai relative to Kuwait. The results of the UV study have already been used to improve the standardized weathering of encapsulants. The example for Damp Heat testing is given to increase awareness of a degradation believed to be ubiquitously occurring in safety and design-type qualification testing of PV modules.

14 SOLAR ENERGY↗

Sensitivity of Atmospheric River Vapor Transport and Precipitation to Uniform Sea Surface Temperature Increases

Abstract Filaments of intense vapor transport called atmospheric rivers (ARs) are responsible for the majority of poleward vapor transport in the midlatitudes. Despite their importance to the hydrologic cycle, there remain many unanswered questions about changes to ARs in a warming climate. In this study we perform a series of escalating uniform SST increases (+2, +4, and +6K, respectively) in the Community Atmosphere Model version 5 in an aquaplanet configuration to evaluate the thermodynamic and dynamical response of AR vapor content, transport, and precipitation to warming SSTs. We find that AR column integrated water vapor (IWV) is especially sensitive to SST and increases by 6.3–9.7% per degree warming despite decreasing relative humidity through much of the column. Further analysis provides a more nuanced view of AR IWV changes: Since SST warming is modest compared to that in the midtroposphere, computing fractional changes in IWV with respect to SST results in finding spuriously large increases. Meanwhile, results here show that AR IWV transport increases relatively uniformly with temperature and at consistently lower rates than IWV, as modulated by systematically decreasing low‐level wind speeds. Similarly, changes in AR precipitation are related to a compensatory relationship between enhanced near‐surface moisture and damped vertical motions.

54 ENVIRONMENTAL SCIENCES↗

ARM data-oriented metrics and diagnostics package for climate model evaluation (ARM-DIAGS-V3) version 3

A Python-based metrics and diagnostics package is currently being developed by the ARM Infrastructure Team at Lawrence Livermore National Laboratory to facilitate the use of long-term high frequency measurements from the ARM program in evaluating the regional climate simulation of clouds, radiation, precipitation, and aerosols. This metrics and diagnostics package computes climatological means of targeted climate model simulation and generates tables and plots for comparing the model simulation with ARM observational data. The CMIP model data sets are also included in the package to enable model inter-comparison as demonstrated in Zhang et al. (2018) and Zhang et al. (2020). The mean of the CMIP model can be served as a reference for individual models. Basic performance metrics are computed to measure the accuracy of mean state and variability of climate models. The evaluated physical quantities include cloud fraction, temperature, relative humidity, cloud liquid water path, total column water vapor, precipitation, sensible and latent heat fluxes, aerosol optical depth, and radiative fluxes, with plan to extend to more fields, such as the evaluation of model simulated aerosol physicochemical properties and cloud microphysics properties. Process-oriented diagnostics focusing on aerosol, cloud, and precipitation-related phenomena are also being developed for the evaluation and development of specific model physical parameterizations. In addition to the Southern Great Plains (SGP), North Slope of Alaska (NSA) and Tropical Western Pacific (TWP) atmospheric observatories in the ARMDIAGS version 2.0, the version 3.0 package have extended to the data collected at the ARM Eastern North Atlantic (ENA) atmospheric observatory and the Observation and Modeling of the Green Ocean Amazon (GOAMAZON) field campaign. The metrics and diagnostics package are currently built upon standard Python libraries and additional Python packages developed by DOE (CDAT). The ARM metrics and diagnostic package is available publicly with the hope that it can serve as an easy entry point for climate modelers to compare their models with ARM data. In this report, we first provide an overview of major metrics in section 2. The input data, which constitutes the core content of the metrics and diagnostics package, is summarized in section 3. A user's guide documenting the workflow/structure of the version 3.0 codes and including step-by-step instruction for running the package is described in section 4.

54 ENVIRONMENTAL SCIENCES↗

Diagnosis of PV Cell Antireflective Coating Degradation Resulting From Hot-Humid High-Voltage Potential Aging

Corrosion of the antireflective coating on a photovoltaic cell ("ARc corrosion") has previously been observed in studies using hot-humid test conditions with external high-voltage (HV) bias. This study primarily focuses on known vulnerable legacy aluminum back surface field cells in mini-modules (MiMos) put through comparative stepped stress tests. Each cell type had MiMos at +1500 V, -1500 V, or unbiased ("Voc") potential, which were sequentially subjected to test conditions of 60 degrees C/60% relative humidity (RH) for 96 h, as in International Electrotechnical Commission Technical Specification 62804-1; 70 degrees C/70% RH for 200 h; and 85 degrees C/85% RH for 200 h. Characterizations at each step included visual camera and electroluminescence (EL) imaging, colorimetry, and current-voltage curve tracing. Final characterizations included: Suns-Voc, spatial mapping of external quantum efficiency, high-resolution photoluminescence, EL, and dark lock-in thermography imaging. Forensics were performed on extracted cores, including scanning electron microscopy (SEM) with energy-dispersive X-ray spectroscopy (EDS), X-ray photoelectron spectroscopy, and scanning Auger microscopy (SAM). Forensics were also conducted on MiMos from previous studies that underwent stepped HV aging and separate outdoor aged full-sized modules. ARc corrosion was specifically seen for the glass/encapsulant/cell side of the +1500 V (HV+) stressed MiMos and modules. Appearance, color, and reflectance were the most distinguishing characteristics relative to glass corrosion, gridline corrosion and delamination, and other concurrent degradation modes. SEM/EDS and SAM identified the conversion of silicon nitride to hydrated silica, hydrous silica, or hydrated amorphous silica, which preferentially occurred at the edges and tips of the pyramidal textured cell surface.

14 SOLAR ENERGY↗

Oxygen Isotope Fractionation in U 3 O 8 during Thermal Processing in Humid Atmospheres

The incorporation of oxygen isotopes from water into uranium oxides during industrial processing presents a pathway for determining a material’s geographical origin. This study is founded on the hypothesis that oxygen isotopes from atmospheric water vapor will exchange with isotopes of oxygen in solid uranium oxides during thermal processing or calcination. Using a commonly encountered oxide, U 3 O 8 , the exchange kinetics and equilibrium fractionation with water vapor (in a concentration range of 50–55% relative humidity) were investigated using processing temperatures of 400, 600, and 800 °C. In an atmosphere containing only water vapor diluted in N 2 , oxygen isotope equilibration in U 3 O 8 occurred within 12 h at 400 °C and within 2 h at 600 and 800 °C. Fractionation factors (1000lnα, U 3 O 8 –H 2 O) between the water and oxide were –12.1, –11.0, and –8.0 at 400, 600, and 800 °C, respectively. With both humidity and O 2 present in the calcining atmosphere, isotopic equilibration is attained within 2 h at and above 400 °C. In this mixed atmosphere, which was designed to emulate Earth’s troposphere, isotopes are incorporated preferentially from water vapor at 400 °C and from O 2 at 600 and 800 °C. Rapid and temperature/species-dependent isotope exchange also elucidated the impact of retrograde exchange in humid air, showing a shift from O 2 -dependent to H 2 O-dependent fractionation as U 3 O 8 cooled from 800 °C. These results confirm that uranium oxides inherit oxygen isotopes from humidity during thermal processing, illuminating an important mechanism in the formation of this forensic signature.

07 ISOTOPE AND RADIATION SOURCES↗

Diagnosis of PV Cell Antireflective Coating Degradation Resulting from Hot-Humid, High Voltage Potential Aging

Corrosion of the antireflective coating on a photovoltaic cell ("ARc corrosion") has previously been observed in studies using hot-humid test conditions with external high-voltage (HV) bias. This study primarily focuses on known vulnerable, legacy aluminum back surface field (Al-BSF) cells in mini-modules (MiMos) put through comparative stepped stress tests. Each cell type had MiMos at +1500 V, -1500 V, or unbiased ("Voc") potential, which were sequentially subjected to test conditions of 60deg C/60% relative humidity (RH) for 96 h, as in International Electrotechnical Commission (IEC) Technical Specification 62804-1; 70 deg C/70% RH for 200 h; and 85 deg C/85% RH for 200 h. Characterizations at each step included visual camera and electroluminescence (EL) imaging, colorimetry, and current-voltage (I-V) curve tracing. Final characterizations included: Suns-Voc; spatial mapping of external quantum efficiency (EQE); high-resolution photoluminescence (PL), EL, and dark lock-in thermography (DLIT) imaging. Forensics were performed on extracted cores, including scanning electron microscopy (SEM) with energy-dispersive X-ray spectroscopy (EDS), X-ray photoelectron spectroscopy (XPS), and scanning Auger microscopy (SAM). Forensics were also conducted on MiMos from previous studies that underwent stepped HV aging and separate outdoor aged full-sized modules. ARc corrosion was specifically seen for the glass/encapsulant/cell side of the +1500V (HV+) stressed MiMos and modules. Appearance, color, and reflectance were the most distinguishing characteristics relative to glass corrosion, gridline-corrosion and -delamination as well as other concurrent degradation modes. SEM/EDS and SAM identified conversion of silicon nitride to hydrated silica, hydrous silica, or hydrated amorphous silica, which preferentially occurred at the edges and tips of the pyramidal textured cell surface.

14 SOLAR ENERGY↗

Membrane Thickness Impact on Chemical Degradation Rates

Abstract A comprehensive investigation of PFSA membrane chemical degradation rates as a function of thickness (8-20 µm) is reported. The two-pronged study was conducted on bare membranes and as components of chemically-mitigated and mechanically-reinforced, state-of-the-art (SOA) membrane electrode assemblies (MEAs). The bare membranes were subjected to H2O2 vapor test and MEAs were degraded under OCV conditions, both at 90°C. Both test types employed fluoride release rates (FRR) to monitor chemical degradation rates. Vapor tests revealed that area-specific degradation rates were positively correlated with membrane thickness, but thickness normalized degradation rates were independent of thickness. Open-circuit voltage (OCV) investigations spanning the membrane thickness series of MEAs was probed via a 27-experiment 3(4-1) fractional factorial experimental design. Statistical analysis of the FRR values revealed that chemical degradation rates were dominated by the relative humidity value and that the area-specific degradation rates of MEAs were independent of membrane thickness. The OCV chemical durability insensitivity to membrane thickness is supported by on-load membrane chemical durability studies at the stack level. The results suggest that ,despite smaller ionomer inventory, SOA thin membranes and MEAs are not greatly disadvantaged relative to thicker membranes from a chemical durability perspective, provided oxidative stress levels are controlled throughout application lifetime.

Coms, Frank D. (ORCID:0000000249160350)↗

Effect of inorganic-to-organic mass ratio on the heterogeneous OH reaction rates of erythritol: implications for atmospheric chemical stability of 2-methyltetrols

The 2-methyltetrols have been widely chosen as chemical tracers for isoprene-derived secondary organic aerosols. While they are often assumed to be relatively unreactive, a laboratory study reported that pure erythritol particles (an analog of 2-methyltetrols) can be heterogeneously oxidized by gas-phase OH radicals at a significant rate. This might question the efficacy of these compounds as tracers in aerosol source-apportionment studies. Additional uncertainty could arise as organic compounds and inorganic salts often coexist in atmospheric particles. To gain more insights into the chemical stability of 2-methyltetrols in atmospheric particles, this study investigates the heterogeneous OH oxidation of pure erythritol particles and particles containing erythritol and ammonium sulfate (AS) at different dry inorganic-to-organic mass ratios (IOR) in an aerosol flow tube reactor at a high relative humidity of 85 %. The same reaction products are formed upon heterogenous OH oxidation of erythritol and erythritol–AS particles, suggesting that the reaction pathways are not strongly affected by the presence and amount of AS. On the other hand, the effective OH uptake coefficient, $γ_{eff}$, is found to decrease by about a factor of ~20 from 0.45±0.025 to 0.02±0.001 when the relative abundance of AS increases and the IOR increases from 0.0 to 5.0. One likely explanation is the presence of dissolved ions slows down the reaction rates by decreasing the surface concentration of erythritol and reducing the frequency of collision between erythritol and gas-phase OH radicals at the particle surface. Hence, the heterogeneous OH reactivity of erythritol and likely 2-methyltetrols in atmospheric particles would be slower than previously thought when the salts are present. Given 2-methyltetrols often coexist with a significant amount of AS in many environments, where ambient IOR can vary from ~1.89 to ~250, our kinetic data would suggest that 2-methyltetrols in atmospheric particles are likely chemically stable against heterogeneous OH oxidation under humid conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterizing photovoltaic backsheet adhesion degradation using the wedge and single cantilever beam tests, Part II: Accelerated tests

Photovoltaic (PV) backsheets provide critical moisture, mechanical, and electrical insulation to the backside of PV modules, but their continued functionality depends upon their ability to remain well adhered over years of harsh environmental exposure. A study of adhesive strength was conducted on several PV backsheet types exposed to indoor accelerated weathering. Two adhesion tests – the wedge test and single cantilever beam test – were used to measure adhesion energy in four backsheets: two with fluoropolymer-based outer (airside) layers – polyvinyl fluoride (PVF), polyvinylidene fluoride (PVDF) – and two with non-fluoropolymer-based outer layers–polyamide (PA) and polyethylene terephthalate (PET). The effects of changes in temperature, ultraviolet (UV) irradiance, relative humidity, and a periodic water spray were studied. The PET-, PVF- and PVDF-based backsheets all showed instances of debonding in an adhesive layer, which is commonly reported. Furthermore, for the PA-, PET-, and PVDF-based backsheets, adhesion energy dropped fairly rapidly with exposure, reaching very low levels by 4000 h. The PVF-based backsheet was relatively robust to weathering. Pull-off of an outer chalking layer in the PA- and PET-based backsheets suggested a sensitivity to UV. Adhesion in these two backsheets was also highly sensitive to changes in moisture level. Changes in UV irradiance and temperature did not show a statistically significant effect on adhesion loss for the exposure levels used. The present work is part of a two-part adhesion study on both field-weathered and indoor-exposed backsheets, and forms a basis for understanding adhesion degradation across a variety of backsheet types and degradation factors.

14 SOLAR ENERGY↗

High-temperature low-humidity proton exchange membrane with “stream-reservoir” ionic channels for high-power-density fuel cells

The perfluorosulfonic acid (PFSA) proton exchange membrane (PEM) is the key component for hydrogen fuel cells (FCs). We used in situ synchrotron scattering to investigate the PEM morphology evolution and found a “stream-reservoir” morphology, which enables efficient proton transport. The short-side-chain (SSC) PFSA PEM is fabricated under the guidance of morphology optimization, which delivered a proton conductivity of 193 milliSiemens per centimeter [95% relativity humidity (RH)] and 40 milliSiemens per centimeter (40% RH) at 80°C. The improved glass transition temperature, water permeability, and mechanical strength enable high-temperature low-humidity FC applications. Performance improvement by 82.3% at 110°C and 25% RH is obtained for SSC-PFSA PEM FCs compared to Nafion polymer PEM devices. The insights in chain conformation, packing mechanism, crystallization, and phase separation of PFSAs build up the structure-property relationship. In addition, SSC-PFSA PEM is ideal for high-temperature low-humidity FCs that are needed urgently for high-power-density and heavy-duty applications.

25 ENERGY STORAGE↗

Synthesis of porous organic cage CC3 via solvent modulated evaporation

We demonstrate a Humidity Modulated Solvent Evaporation (HMSE) approach to promote the nucleation and growth of CC3 crystals. This approach relies on the gradual evaporation of dichloromethane (solvent) from a diluted concentration of CC3 precursors deposited on aluminum foil. The slow solvent evaporation allowed enough time for the organization and formation of CC3 porous organic cage. The solvent diffusion rate was modulated by the relative humidity in the system. The slow kinetics implied during the development of CC3 phase, allowed the formation of CC3 crystals. HRTEM, SAED, SEM, and XRD patterns were used as pivotal characterization techniques to follow and confirm the formation of CC3 crystals.

porous organic cages, modulated evaporation, cryst↗

Characterizing Thunderstorm Gust Fronts near Complex Terrain

Fire safety, aviation, wind energy, and structural-engineering operations are impacted by thunderstorm outflow boundaries or gust fronts (GFs) particularly when they occur in mountainous terrain. For example, during the 2013 Arizona Yarnell Hill Fire, 19 firefighters were killed as a result of sudden changes in fire behavior triggered by a passing GF. Knowledge of GF behavior in complex terrain also determines departure and landing operations at nearby airports, and GFs can induce exceptional structural loads on wind turbines. Furthermore, while most examinations of GF characteristics focus on well-organized convection in areas such as the Great Plains, here the investigation is broadened to explore GF characteristics that evolve near the complex terrain of the Colorado Rocky Mountains. Using in situ observations from meteorological towers, as well as data from wind-profiling lidars and a microwave radiometer, 24 GF events are assessed to quantify changes in wind, temperature, humidity, and turbulence in the lowest 300 m AGL as these GFs passed over the instruments. The changes in magnitude for all variables are on average weaker in the Colorado Front Range than those typically observed from organized, severe storms in flatter regions. Most events from this study experience an increase in wind speed from 1 to 8 m s -1 , relative humidity from 1% to 8%, and weak vertical motion from 0.3 to 3.6 m s -1 during GF passage while temperature drops by 0.2°–3°C and turbulent kinetic energy peaks at >4 m2 s -2 . Vertical profiles reveal that these changes vary little with height in the lowest 300 m.

54 ENVIRONMENTAL SCIENCES↗

Multi-Parameter Optical Fiber for Distributed Sensing of Humidity, CH4, CO2, and Corrosion

This work describes the use of the optical fiber sensor (OFS) for successful monitoring of humidity, CH4, and CO2 based on the strain produced along the single-mode fiber (SMF) sensor. This is enabled by absorption of H2O/gases onto the commercially available polyacrylate coated jacketed portion of the fiber resulting in a change in strain. Under equilibrium, a differential microstrain was observed along the jacketed portion of the SMF with N2, CH4, and CO2 at different relative humidity (RH) conditions. The strain response of the SMF under various mixed gas composition and different RH conditions were also measured and made calibration curves accordingly. Linear regression and principal component analysis of the strain datasets provided deconvolution of the impact of strain from H2O, N2, CH4, and CO2. Additionally, modified OFS comprised of the Fe coated fiber section was employed to monitor corrosion based on the increase in backscattered intensity amplitude of the light being passed once corrosion of Fe occurs. Also, corrosion of Fe was studied under soil by installing the fiber in soil with protective measures which would prevent the sensor being mechanically disturbed or broken during installation. The corrosion rates were studied by monitoring the rate at which the intensity of backscattered light amplitude attains a steady state value when complete corrosion of Fe with a specific coating thickness occurs.

Mainali, Badri↗