Search NASA⌕ Search

SEARCH · Search NASA

Results for “responsive loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Application of the mobility power flow approach to structural response from distributed loading

The problem of the vibration power flow through coupled substructures when one of the substructures is subjected to a distributed load is addressed. In all the work performed thus far, point force excitation was considered. However, in the case of the excitation of an aircraft fuselage, distributed loading on the whole surface of a panel can be as important as the excitation from directly applied forces at defined locations on the structures. Thus using a mobility power flow approach, expressions are developed for the transmission of vibrational power between two coupled plate substructures in an L configuration, with one of the surfaces of one of the plate substructures being subjected to a distributed load. The types of distributed loads that are considered are a force load with an arbitrary function in space and a distributed load similar to that from acoustic excitation.

Cuschieri, J. M.↗

Do Integrins Mediate the Skeletal Response to Altered Loading?

In vivo experiments were performed to examine the role of B1 integrin in skeletal adaptation to reduced and increased loading. Transgenic mice were generated with a dominant negative form of the B1 integrin cytoplasmic domain with expression driven by the osteocalcin promoter (pOCb1DN). This fragment consists of the transmembrane and intracellular domains and interferes with endogenous integrin signalling in vitro. This promoter targets expression of the transgene to mature bone cells. Expression of the transgene was confirmed by immunoprecipitation and western blotting. Reduced loading was generated by hindlimb suspension and increased loading the resumption of normal loading following hindlimb suspension. Two groups of female 35-day old mice were examined: poCb1DN transgenic mice (TG) and wild-type littermate controls (WT). Animals were hindlimb suspended for 1 week (HU, n = l0/gp) or 4 weeks (HU, n = 4 - 7/gp) or suspended for 4 weeks followed by reloading by normal ambulation for 4 weeks (RL, n = l0/gp). Age-matched controls (CT) were pairfed based on the HU food intake. The protocols were approved by the NASA Ames Research Center IACUC. Upon completion of the experimental protocol, body mass was recorded and tissues of interest removed and analyzed following standard procedures. Femoral whole bone structural behavior was measured in torsion to failure to obtain whole bone strength (failure torque) and torsional rigidity. Ash content (ash) and fraction (% ash) were determined for the tibia. Total ash is indicative of bone size whereas %ash is a material property. Tibial curvature was measured from microradiographs. For each experiment, the effects of genotype (TG, WT) and treatment (CT, HU/RL) were assessed by two-factor ANOVA followed by the Tukey-Kramer posthoc to identify significant differences at an alpha level of 0.05. Our goal was to understand differences resulting from altered integrin function in the adaptation to altered loading.

vanderMeulen, Marjolein C. H.↗

Integration of a Finite Element Model with the DAP Bone Remodeling Model to Characterize Bone Response to Skeletal Loading

NASA's Digital Astronaut Project (DAP) has developed a bone remodeling model that has been validated for predicting volumetric bone mineral density (vBMD) changes of trabecular and cortical bone in the absence of mechanical loading. The model was recently updated to include skeletal loading from exercise and free living activities to maintain healthy bone using a new daily load stimulus (DLS). This new formula was developed based on an extensive review of existing DLS formulas, as discussed in the abstract by Pennline et al. The DLS formula incorporated into the bone remodeling model utilizes strains and stress calculated from finite element model (FEM) of the bone region of interest. The proximal femur was selected for the initial application of the DLS formula, with a specific focus on the femoral neck. METHODS: The FEM was generated from CAD geometry of a femur using de-identified CT data. The femur was meshed using linear tetrahedral elements Figure (1) with higher mesh densities in the femoral neck region, which is the primary region of interest for the initial application of the DLS formula in concert with the DAP bone remodeling model. Nodal loads were applied to the femoral head and the greater trochanter and the base of the femur was held fixed. An L2 norm study was conducted to reduce the length of the femoral shaft without significantly impacting the stresses in the femoral neck. The material properties of the FEM of the proximal femur were separated between cortical and trabecular regions to work with the bone remodeling model. Determining the elements with cortical material properties in the FEM was based off of publicly available CT hip scans [4] that were segmented, cleaned, and overlaid onto the FEM.

Bone Remodeling↗

CDKN1A/P21’S Role in Osteoprogenitor Fate Regulation in Response to Mechanical Loading: A Single Cell Resolution Investigation

Forces generated by gravity in load-bearing tissues such as bone marrow promote stem cell-based tissue-regenerative processes by increasing proliferation and differentiation of tissue progenitors. Conversely, in microgravity, mouse bone marrow mesenchymal and hematopoietic precursors down-regulate differentiation markers and up-regulate stemness maintenance genes. During microgravity, these transcriptomic changes are associated with Cdkn1a overexpression in osteoprogenitors, and further the homozygous deletion of the CDKN1a gene in the mouse model results in elevated stem-cell based regeneration of severed digits and ear-hole punches. In this work we sought to test the hypothesis that gravity mechanotransduction regulates mesenchymal stem cell derived osteoprogenitor based osteogenesis by modulating proliferation and differentiation fates at specific cell cycle stages via a p21/CDKN1a-regulated mechanism.. To test our hypothesis, we isolated primary mouse bone marrow osteoprogenitors from Cdkn1a-/- (null) or wildtype mice, cultured the cells for 7-days unloaded in osteogenic differentiation media, to allow commitment of the adherent cell population, and subsequently, cultured an additional 48-hours under cyclic stretch or static control loading conditions. After 48-hours of dynamic mechanical loading, we used a 10X Genomics Chromium/Single Cell controller to generate bar-coded single cell Illumina libraries and sequenced expressomes for 6,000 static control and 6,000 cyclic stretch cells for each genotype. Stage-specific single cell analyses show Cdkn1a-/- osteogenic cultures are more differentiated with fewer progenitors, and that cyclic stretch further promotes the conversion of progenitors to osteoblasts in both wildtype and Cdkn1a-/- backgrounds. The proportion of late mineralizing osteoblasts doubled in Cdkn1a-/- cultures, but is not affected by load. Finally, single cell expression of Cdkn1a, in the wildtype cells, is most strongly suppressed by cyclic stretch both in early and late osteoblasts, and minimally in the progenitor population. Collectively, our results support the hypothesis that Cdkn1a constitutively plays a mechano-reversible anti-proliferative role during stem cell-based bone tissue regeneration, and suggests a new molecular target to counter regenerative deficits caused by disuse.

Eduardo Almeida↗

Extracting maximal frequency response potential in controllable loads

Methods and apparatus are disclosed for extracting maximal frequency response potential in controllable loads. In one example, a method includes assigning a fitness metric to at least one electrical device coupled to a power grid, assigning a frequency threshold based on the fitness metric, and transmitting the assigned frequency threshold to the at least one electrical device. The fitness metric can be based at least in part on an availability component and a quality component associated with the at least one device and the frequency threshold can cause the at least one electrical device to activate autonomously based on a frequency of the power grid.

Lian, Jianming↗

Electrical Load Modeling and Simulation

Electricity consumer demand response and load control are playing an increasingly important role in the development of a smart grid. Smart grid load management technologies such as Grid FriendlyTM controls and real-time pricing are making their way into the conventional model of grid planning and operations. However, the behavior of load both affects, and is affected by load control strategies that are designed to support electric grid planning and operations. This chapter discussed the natural behavior of electric loads, how it interacts with various load control and demand response strategies, what the consequences are for new grid operation concepts and the computing issues these new technologies raise.

Demand Response↗

On the solution of problems involving impact type loading

The response of beam and plate members to pulse and impact loading is investigated, and numerical methods are analyzed and compared. The equations of motion, the finite difference and finite element methods, the time integration/Runge-Kutta techniques, and material modeling are discussed in detail. It is found that both the finite difference and the finite element methods could be accurately employed to discretize the spatial variation in the displacements. Central differences or a fourth order Runge-Kutta algorithm could be used for the time integration. The total energy of the system would give the stability and accuracy of the solution. Results showed that the finite element method provided better efficiency in obtaining accurate solution than the finite difference method when a scalar processor is used. However, the finite difference method was more efficient on the vector processor. Therefore, the most efficient method of solution depends on the type of computer present for the analysis.

Moyer, E. T., Jr.↗