Search NASA⌕ Search

SEARCH · Search NASA

Results for “rf”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Nuclear rotation at the fission limit in Rf 254

A ground-state rotational band in the fissile nucleus Rf254 was observed for the first time. Levels up to spin 14 and excitation energy of 1.56 MeV were observed. The Rf254 nuclei were produced using the Pb206(Ti50,2n) fusion-evaporation reaction. It is the weakest reaction channel ever studied using in-beam γ-ray spectroscopic methods. The reaction products were separated from the beam in the Argonne gas-filled analyzer (AGFA). The Rf254 nuclei were implanted into a double-sided Si strip detector at the AGFA focal plane and tagged with subsequent ground-state spontaneous fission decays using temporal and spatial correlations. Prompt γ rays in coincidence with the Rf254 recoils were detected in the Gammasphere array of Ge detectors. In order to identify the ground-state rotational band in Rf254, a method for identifying rotational bands in low statistics γ-ray spectra was developed. The deduced Rf254 kinematic moment of inertia is smaller compared to neighboring even-even nuclei. This is most likely associated with a slightly lower quadrupole deformation and stronger pairing correlations in Rf254. The behavior of the moment of inertia as a function of rotational frequency is similar to that of the lighter N=150 isotones Fm250 and No252.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Low-Power Characterization and Integration of Carbon Black Resistive Ink for Aerosol Jet-Printed RF Components

Aerosol jet printing (AJP) is gaining attention in additive manufacturing research, especially in the discipline of microwave engineering. Currently, no reliable AJP method exists to fabricate resistors that are both electrically small and with a resistance compatible with waveguide impedances for use in microwave components. In this work, the commercially available Metalon JR-038 is characterized and used to fabricate a resistor that is 100 μ m long by 250 μ m wide for the first time to the best of our knowledge. Furthermore, this resistor was then used to fabricate a Ka-band Wilkinson power divider using only the AJP process.

36 MATERIALS SCIENCE↗

Modeling of Thermal Quench in Superconducting RF Cavities

Superconducting radio frequency (SRF) cavities are often limited by thermal quench, which is an excessive electromagnetic heating that occurs in the high magnetic field area and expands thereafter forcing the cavity to lose its superconducting state. In this paper, we demonstrate how the quench phenomena can be modeled using a coupled electromagnetic thermal analysis. The proposed model takes into account the nonlinearity of the material properties at cryogenic temperature and the effect of Kapitza resistance. The proposed approach is used to compute the thermal quench field of a 3.9 GHz 9-cell accelerating cavity, a 2.815 GHz deflecting cavity, and a 1.3GHz 9-cell accelerating cavity. Here, the computed values of quenchfield are in good agreement with the measured ones observedduring vertical testing at 2 K. Without loss of generality, theproposed methodology can be applied to other cavity geometries.

43 PARTICLE ACCELERATORS↗

Construction of a New MgB 2 Coating System for 1.3-GHz Superconducting RF Cavities at LANL

After many years of evaluating MgB 2 films prepared with various techniques for the application to superconducting radio-frequency (SRF) cavities, we have decided to build a system to coat full-size 1.3-GHz elliptical cavities. This paper describes the design and construction of the system. Additionally, we briefly describe experimental results with a small system and first tests with the new large system. In conclusion, we were able to obtain superconducting samples with a T c of up to 38 K with the small system, but we have not been able to get any superconducting samples with the new system yet.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Magnetron R&D for high efficiency CW RF sources for industrial accelerators

The scheme of using high-efficiency magnetrons to drive radiofrequency accelerators has been demonstrated at 2450 MHz in CW mode *. Magnetron test stands at JLab and GA have been set up to further test the noise figure and the locking speed of the injection phase-lock method. For higher power applications, power combining experiments using a TM010 cavity-type combiner and a magic tee for the binary combiner while using a single clean injection signal has been carried out at 2450 MHz. The frequency pulling effect between the magnetron and a low-Q cavity has been shown to enhance the frequency locking bandwidth compared to the injection phase-lock alone. The principle has been studied by the equivalent circuit simulation, analytical model, and finally confirmed experimentally on the magnetrons. Due to the pandemic delay in 2020, the equivalent high power tests using a 75kW, 915MHz industrial magnetron will be done in 2021 and will be reported in a future paper.