Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample acquisitions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Sensor Web in Antarctica: Developing an Intelligent, Autonomous Platform for Locating Biological Flourishes in Cryogenic Environments

The most rigorous tests of the ability to detect extant life will occur where biotic activity is limited by severe environmental conditions. Cryogenic environments are among the most severe-the energy and nutrients needed for biological activity are in short supply while the climate itself is actively destructive to biological mechanisms. In such settings biological activity is often limited to brief flourishes, occurring only when and where conditions are at their most favorable. The closer that typical regional conditions approach conditions that are actively hostile , the more widely distributed biological blooms will be in both time and space. On a spatial dimension of a few meters or a time dimension of a few days, biological activity becomes much more difficult to detect. One way to overcome this difficulty is to establish a Sensor Web that can monitor microclimates over appropriate scales of time and distance, allowing a continuous virtual presence for instant recognition of favorable conditions. A more sophisticated Sensor Web, incorporating metabolic sensors, can effectively meet the challenge to be in "the right place in the right time". This is particularly of value in planetary surface missions, where limited mobility and mission timelines require extremely efficient sample and data acquisition. Sensor Webs can be an effective way to fill the gap between broad scale orbital data collection and fine-scale surface lander science. We are in the process of developing an intelligent, distributed and autonomous Sensor Web that will allow us to monitor microclimate under severe cryogenic conditions, approaching those extant on the surface of Mars. Ultimately this Sensor Web will include the ability to detect and/or establish limits on extant microbiological activity through incorporation of novel metabolic gas sensors. Here we report the results of our first deployment of a Sensor Web prototype in a previously unexplored high altitude East Antarctic Plateau "micro-oasis" at the MacAlpine Hills, Law Glacier, Antarctica.

Delin, K. A.↗

Pancam Imaging of the Mars Exploration Rover Landing Sites in Gusev Crater and Meridiani Planum

The Mars Exploration Rovers carry four Panoramic Camera (Pancam) instruments (two per rover) that have obtained high resolution multispectral and stereoscopic images for studies of the geology, mineralogy, and surface and atmospheric physical properties at both rover landing sites. The Pancams are also providing significant mission support measurements for the rovers, including Sun-finding for rover navigation, hazard identification and digital terrain modeling to help guide long-term rover traverse decisions, high resolution imaging to help guide the selection of in situ sampling targets, and acquisition of education and public outreach imaging products.

Bell, J. F., III↗

Measurements of Flow Turbulence in the NASA Langley Transonic Dynamics Tunnel

An assessment of the flow turbulence in the NASA Langley Transonic Dynamics Tunnel (TDT) was conducted during calibration activities following the facility conversion from a Freon-12 heavy-gas test medium to an R134a heavy-gas test medium. Total pressure, static pressure, and acoustic pressure levels were measured at several locations on a stingmounted rake. The test measured wall static pressures at several locations although this paper presents only those from one location. The test used two data acquisition systems, one sampling at 1000 Hz and the second sampling at 125 000 Hz, for acquiring time-domain data. This paper presents standard deviations and power spectral densities of the turbulence points throughout the wind tunnel envelope in air and R134a. The objective of this paper is to present the turbulence characteristics for the test section. No attempt is made to assess the causes of the turbulence. The present paper looks at turbulence in terms of pressure fluctuations. Reference 1 looked at tunnel turbulence in terms of velocity fluctuations.

Wiesman, Carol D.↗

HYDRA: High Speed Simulation Architecture for Precision Spacecraft Formation Flying

This viewgraph presentation describes HYDRA, which is architecture to facilitate high-fidelity and real-time simulation of formation flying missions. The contents include: 1) Motivation; 2) Objective; 3) HYDRA-Description and Overview; 4) HYDRA-Hierarchy; 5) Communication in HYDRA; 6) Simulation Specific Concerns in HYDRA; 7) Example application (Formation Acquisition); and 8) Sample Problem Results.

simpulations↗

Atom Probe Tomography and Three-Dimensional Atomic Scale Characterisation of Interplanetary Dust Particles: Inorganic and Organic, Hydrous and Anhydrous Assemblages

Interplanetary dust particles (IDPs)preserve primordial fragments from our Solar System and external stellar systems, sampled from a vast range of dust forming bodies that often display smaller degrees of parent body processing than is seen in meteorites. IDPs preserve some of the smallest astromaterials from our Solar System, many of which are believed to be among the most important materials for studying physical and chemical processing, and formation mechanisms occurring within the interstellar medium (ISM), Solar Nebula and external planetary systems[1]. However, their formation processes and provenance are poorly constrained, owing in part to spatial resolution limitations of traditional analytical techniques. Atom probe tomography (APT) uses a pulsed laser to field-evaporate material at the atomic scale from needle-shaped samples, and time-of-flight spectrometry for 3D reconstruction of element and isotope distribution in samples after data acquisition. This technique has the highest spatial resolution available of any technique used within the geoscience field[2]. However, measuring multi-phase specimens and porous media in APT can be challenging, two primary characteristics of IDPs. Here we present a custom method for APT needle design and the first results of a 3Datomic scale study of interplanetary dust particles, salt crystals and extraterrestrial insoluble and soluble organic matter designed to overcome the challenges of studying IDP-like materials.

N D Nevill↗

Using X-Ray Computed Tomography as a Tool for Preliminary Examination Tool of Current and Future Extraterrestrial Sample Return Missions

The Astromaterials Acquisition and Curation Office at the Johnson Space Center is the past, present, and future home of all of NASA’s astromaterials sample collections. The primary goals of the curation office are to maintain the long-term integrity of the samples and ensure that the samples are distributed for scientific study in a fair, timely, and responsible manner, thus maximizing the return on each sample. Part of the curation process is planning for the future. To this end, we perform fundamental research in advanced curation initiatives to better prepared for future sample return missions. Advanced Curation is tasked with developing procedures, technology, and data sets necessary for curating new sample collections, or getting new results from existing sample collections. As part of these advanced curation efforts, we have installed and are operating a Nikon XTH 320 X-ray Computed Tomography(XCT) system in the JSC curation office with four interchangeable X-ray sources, a large-area detector, and a heavy-duty stage. These instrument characteristics allow us exceptional flexibility to analyze a wide range of sample sizes, from sub-mm soil particles to rocks >10 cm in diameter. The penetrative nature of the XCT scans allows for astromaterials samples to be analyzed within sealed low-density containers (e.g., Teflon bags), preserving the pristinity of the samples. We have begun scanning of the Apollo and Antarctic Meteorite sample suites in order to non-destructively map out lithic clasts (and other features) within the samples. The data from these scans will be made available to scientists via the JSC curation website and the Astromaterials Curation Newsletter. We anticipate sample requests from these “new” lithic clasts identified in these “old” samples. We also anticipate that XCT analyses like these would be useful for future sample return missions, like the OSIRIS REx mission, as well as future sample return missions.

Zeigler, Ryan↗

Fidelity Analysis of Sampled Imaging Systems

Many modeling, simulation and performance analysis studies of sampled imaging systems are inherently incomplete because they are conditioned on a discrete-input, discrete-output model that only accounts for blurring during image acquisition and additive noise. For those sampled imaging systems where the effects of digital image acquisition, digital filtering and reconstruction are significant, the modeling, simulation and performance analysis should be based on a more comprehensive continuous-input, discrete-processing, continuous-output end-to-end model. This more comprehensive model should properly account for the low-pass filtering effects of image acquisition prior to sampling, the potentially important noiselike effects of the aliasing caused by sampling, additive noise due to device electronics and quantization, the generally high-boost filtering effects of digital processing, and the low-pass filtering effects of image reconstruction. This model should not, however, be so complex as to preclude significant mathematical analysis, particularly the mean-square (fidelity) type of analysis so common in linear system theory. We demonstrate that, although the mathematics of such a model is more complex, the increase in complexity is not so great as to prevent a complete fidelity-metric analysis at both the component level and at the end-to-end system level: that is, computable mean-square-based fidelity metrics are developed by which both component-level and system-level performance can be quantified. In addition, we demonstrate that system performance can be assessed qualitatively by visualizing the output image as the sum of three component images, each of which relates to a corresponding fidelity metric. The cascaded, or filtered, component accounts for the end-to-end system filtering of image acquisition, digital processing, and image reconstruction; the random noise component accounts for additive random noise, modulated by digital processing and image reconstruction filtering; and the aliased noise component accounts for the frequency folding effect of sampling, modulated by digital processing and image reconstruction filtering.

Park, Stephen K.↗

Thermocouple Temperature Measurements in Selective Laser Melting Additive Manufacturing

The extreme thermal history resulting from selective laser melting leads to microstructural characteristics and residual stresses that have considerable impact on the mechanical behavior of the printed part. Accurate measurements of the temperature combined with thermal models are needed to better understand and control the thermal history to optimize mechanical properties. In order to calibrate and validate models, experimental temperature data must be accurately measured in a rapid fashion due to the high speeds of the laser. In this work, a novel method to read data from thermocouples is created with enhanced circuitry that achieves a sampling rate of 10 kHz. This data acquisition rate allows for high precision sampling of SLM heating and cooling cycles.

additive manufacturing↗

Instrumentation and data acquisition for full-scale aircraft crash testing

The Landing and Impact Dynamics Branch of the NASA Langley Research Center has been conducting full-scale aircraft crash tests since the 1970s. Using a pendulum method, aircraft are suspended by cables from a 240-ft high gantry and swung into the impact surface at various attitudes and velocities. Instrumentation for these tests include on-board high-speed cameras, strain gages, load cells, displacement transducers, and accelerometers. Transducers in the aircraft are hard-wired through a long umbilical cable to the data acquisition room. Up to 96 channels of data can be collected at a typical rate of 4000 samples per second. Data acquisition using an FM multiplexed analog system and a high-speed personal computer based digital system is described.

Jones, Lisa E.↗

Perserving Samples and Their Scientific Integrity - Insights into MSR from the Astromaterials Acquisition and Curation Office at NASA Johnson Space Center

The Astromaterials Acquisition and Curation Office at NASA Johnson Space Center (JSC), in Houston, TX (henceforth Curation Office) manages the curation of all past, present, and future extraterrestrial samples returned by NASA missions and shared collections from international partners, preserving their integrity for future scientific study while providing the samples to the international community in a fair and unbiased way. The Curation Office also curates flight and non-flight reference materials and other materials from spacecraft assembly of sample return missions that would have the potential to cross-contaminate a present or future NASA astromaterials collection. These materials are primarily collected during the assembly, test, and launch operations (ATLO) phase and after flight during the recovery and curation phase. In addition, the Curation Office curates non-flight, flight-like, and flown witness plates for sample return missions. These reference materials and witness plates provide the scientific community with the fundamental ability to reconstruct the contamination/alteration history of the sample collection through the course of the mission, with the overall goal of strengthening the scientific conclusions drawn from the study of returned materials.

Harrington, A. D.↗

Smart Sensor Node Development, Testing and Implementation for Rocket Propulsion Systems

Successful design and implementation of an Integrated System Health Management (ISHM) approach for rocket propulsion systems requires the capability improve the reliability of complex systems by detecting and diagnosing problems. One of the critical elements in the ISHM is an intelligent sensor node for data acquisition that meets specific requirements for rocket motor testing including accuracy, sample rate and size/weight. Traditional data acquisition systems are calibrated in a controlled environment and guaranteed to perform bounded by their tested conditions. In a real world ISHM system, the data acquisition and signal conditioning needs to function in an uncontrolled environment. Development and testing of this sensor node focuses on a design with the ability to self check in order to extend calibration times, report internal faults and drifts and notify the overall system when the data acquisition is not performing as it should. All of this will be designed within a system that is flexible, requiring little re-design to be deployed on a wide variety of systems. Progress in this design and initial testing of prototype units will be reported.

Mengers, Timothy R.↗

NASA's Astromaterials Database: Enabling Research Through Increased Access to Sample Data, Metadata and Imagery

The Astromaterials Acquisition & Curation Office at NASA's Johnson Space Center (JSC) is the designated facility for curating all of NASA's extraterrestrial samples. Today, the suite of collections includes the lunar samples from the Apollo missions, cosmic dust particles falling into the Earth's atmosphere, meteorites collected in Antarctica, comet and interstellar dust particles from the Stardust mission, asteroid particles from Japan's Hayabusa mission, solar wind atoms collected during the Genesis mission, and space‐exposed hardware from several missions. To support planetary science research on these samples, JSC's Astromaterials Curation Office hosts NASA's Astromaterials Curation digital repository and data access portal [http://curator.jsc.nasa.gov/], providing descriptions of the missions and collections, and critical information about each individual sample. Our office is designing and implementing several informatics initiatives to better serve the planetary research community. First, we are re‐hosting the basic database framework by consolidating legacy databases for individual collections and providing a uniform access point for information (descriptions, imagery, classification) on all of our samples. Second, we continue to upgrade and host digital compendia that summarize and highlight published findings on the samples (e.g., lunar samples, meteorites from Mars). We host high resolution imagery of samples as it becomes available, including newly scanned images of historical prints from the Apollo missions. Finally we are creating plans to collect and provide new data, including 3D imagery, point cloud data, micro CT data, and external links to other data sets on selected samples. Together, these individual efforts will provide unprecedented digital access to NASA's Astromaterials, enabling preservation of the samples through more specific and targeted requests, and supporting new planetary science research and collaborations on the samples.

Evans, Cindy↗

Monolithic four-quadrant multiplier

Integrated configuration for "differential" sequential processor is less susceptible to noise than one using discrete components. Accuracy of version is unaffected by sample-and-hold (S/H) acquisition speed, S/H droop rate, and stray pickup by separate card-mounted parts.

Lampe, D. R.↗

A technique for thick polymer coating of inertial-confinement-fusion targets

A technique to coat a stalk-mounted inertial-confinement fusion (ICF) target with a thick polymer layer has been successfully demonstrated. The polymer solution is first atomized, allowed to coalesce into a droplet, and positioned in a stable acoustic levitating field. The stalk-mounted ICF target is then moved into the acoustic field by manipulating a 3-D positioner to penetrate the surface membrane of the droplet, thus immersing the target in the levitated coating solution. The target inside the droplet is maintained at the center of the levitated liquid using the 3-D positional information provided by two orthogonally placed TV cameras until the drying process is completed. The basic components of the experimental apparatus, including an acoustic levitator, liquid sample deployment device, image acquisition instrumentation, and 3-D positioner, are briefly described.

Lee, M. C.↗

Development of a 0.5 micrometer incoherent Doppler lidar for space application

This paper describes the current status of a prototype 0.53 micrometer Doppler lidar system under development at RCA. This system consists of a frequency doubled Nd:YAG laser constrained to yield a narrow bandwidth, single frequency pulse, a Fabry-Perot Inteferometer (FPI) using an Image Plane Detector (IPD) to measure the backscatter spectrum for each pulse and a Data Acquisition System (DAS) to sample, store, and analyze the backscattered signal. These individual subsystem components have been assembled and preliminary atmospheric testing has recently begun. Atmospheric backscatter spectra are presented which demonstrate the capabilities of this system to distinguish between return signals from aerosols, molecules, and clouds.

Rosenberg, A.↗

Hemodynamic Responses to Head and Neck Cooling

Personal thermoregulatory systems which provide head and neck cooling are used in the industrial and aerospace environments to alleviate thermal stress. However, little information is available regarding the physiologic and circulatory changes produced by routine operation of these systems. The objective of this study was to measure the scalp temperature and circulatory responses during use of one commercially available thermal control system. The Life Support Systems, Inc. Mark VII portable cooling system and a liquid cooling helmet were used in this study. Two EEG electrodes and one skin temperature transducer were placed on the anterior midline of the scalp to measure the scalp blood and temperature. Blood flow was measured using a bipolar impedance rheograph. Ten subjects, seated in an upright position at normal room temperature, were tested at high, medium, moderate, moderate-low and low coolant temperatures. Scalp blood flow was recorded continuously using a computer data acquisition system with a sampling frequency of 200 Hz. Scalp temperature and cooling helmet Inlet temperature was logged periodically during the test period. This study quantifies the effect of head cooling upon scalp temperature and blood flow. These data may also be used to select operational specifications of the head cooling system for biomedical applications such as the treatment of migraine headaches, scalp cooling during chemotherapy, and cooling of multiple sclerosis patients.

Ku, Yu-Tsuan E.↗

Operational Characteristics of Two Commercially Available Personal Cooling Vests

Personal thermoregulatory systems which provide chest cooling are used in the industrial and aerospace environments to alleviate thermal stress. However, little information is available regarding the physiologic and circulatory changes produced by routine operation of these systems. The objectives of this study were to compare the effectiveness of two passive cooling vests, and to measure the body temperature and circulatory changes produced by each cooling vest configuration. A Life Enhancement Technologies, (LET) ice vest garment and a Steele, Inc. vest were used to cool the chest region of 11 male subjects (25 to 55 yr) in this study. Calf, forearm and finger blood flows were measured using a tetrapolar impedance rheograph. The subjects, seated in an upright position at normal room temperature (approximately 21 C) were tested for 60 min. with the cooling system operating at its maximum cooling capacity. Blood flows were recorded continuously using a computer data acquisition system with a sampling frequency of 250 Hz. Oral, right and left ear temperatures and cooling system parameters were logged manually every 5 min. Arm, leg, chest and rectal temperatures; heart rate; respiration; and an activity index were recorded continuously on a U.F.I., Inc. Biolog ambulatory monitor. No significant differences were found in either the oral or ear temperature responses to the two vests. However, the rectal and mean skin temperatures at the end of the cooling period were both significantly lower (P less than 0.05), approximately 0.2 and 1.9 C, respectively for the LET vest than for the Steele garment. These data show that different vest configurations may produce different thermal responses in healthy male subjects which should be considered in the use of these cooling garments.

Ku, Yu-Tsuan E.↗

Operational Characteristics of Four Commercially Available Personal Cooling Vests

Personal thermoregulatory systems which provide chest cooling are used in the industrial and aerospace environments to alleviate thermal stress. However, little information is available regarding the physiologic and circulatory changes produced by routine operation of these systems. The objectives of this study were to compare the effectiveness of two passive and two active cooling vests, and to measure the body temperature and circulatory changes produced by each cooling vest configuration. The MicroClimate Systems and the Life Enhancement Tech(LET) lightweight liquid cooling vests, the Steele Vest and LET's Zipper Front Garment were used to cool the chest region of 11 male and 10 female subjects (25 to 55 yr.) in this study. Calf, forearm and finger blood flows were measured using a tetrapolar impedance rheograph. The subjects, seated in an upright position at normal room temperature (approx.21 C), were tested for 60 min. with the cooling system operated at its maximum cooling capacity. Blood flows were recorded continuously using a computer data acquisition system with a sampling frequency of 250 Hz. Oral, right and left ear temperatures and cooling system parameters were logged manually every 5 min. Arm, leg, chest and rectal temperatures; heart rate; respiration; and an activity index were recorded continuously on a URI Inc. Biolog ambulatory monitor. In general, the male and female subjects' rectal and ear temperature responses to cooling were similar for all vest configurations tested. Oral temperatures during the recovery period were significantly (P<0.05) lower than during the control period, approx.0.2 - 0.5 C, for both men and women wearing any of the four different garments. The corresponding car temperatures were significantly (P<0.05) decreased approx.0.2 - 0.3 C by the end of the recovery period. Compared to the control period, no significant differences were found in rectal temperatures during cooling and recovery periods. These results show that all vest configurations elicit a similar thermal response in both male and female subject groups. However, subject population variance was rather large and may have masked differences between the vests. One vest may prove more effective than another for a given individual, and experience is the only means of determining this.