Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample identifier”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Microbial Load Monitor

The Microbial Load Monitor (MLM) is an automated and computerized system for detection and identification of microorganisms. Additionally, the system is designed to enumerate and provide antimicrobic susceptibility profiles for medically significant bacteria. The system is designed to accomplish these tasks in a time of 13 hours or less versus the traditional time of 24 hours for negatives and 72 hours or more for positives usually required for standard microbiological analysis. The MLM concept differs from other methods of microbial detection in that the system is designed to accept raw untreated clinical samples and to selectively identify each group or species that may be present in a polymicrobic sample.

Gibson, S. F.↗

Laboratory studies of actinide partitioning relevant to 244Pu chronometry

Actinide partitioning and light lanthanide fractionation have been studied to gain an understanding of Pu chemistry under meteoritic and lunar conditions. The goal of the study was to identify conditions and samples from which chronological information can be retrieved. The laboratory investigations involved particle track radiography of the crystal/liquid partitioning of Th, U and Pu among diopsidic clinopyroxene, whitlockite and liquid. It is found that trivalent Pu plays an important role in partitioning for lunar and most meteoritic conditions. The use of Pu/Nd for relative age assessments is supported to some extent by the investigations; samples with unfractionated U, Th and Nd abundances (relative to average solar system values) may be suitable for Pu chronometry.

Benjamin, T.↗

Microgravity effects on electrodeposition of metals and metal-cermet mixtures

An experimental system, designed to investigate the potential advantages of electrodeposition in microgravity, is being developed by the McDonnell Douglas Astronautics Company-Huntsville Division and the University of Alabama in Huntsville. It is intended to fly as an Orbiter payload when NASA resumes STS operations. The system will provide power, thermal conditioning, command and control for the production of electrodeposits; system performance data will be recorded for post-flight analysis. Plated metal surfaces will be created using simple electrolytic cells with pure metal electrodes immersed in aqueous electrolytic solutions. Crystalline structure and other properties will be analyzed to identify differences between samples produced in flight and those obtained from ground-based operations.

Maybee, George W.↗

The globular cluster system of M31

Previous data on globular cluster candidates in M31 have been studied in order to identify a large sample of clusters with reliable UBV photometry and independent reddening estimates. The distribution of the intrinsic colors of the M31 globular clusters is similar to that of the Galactic globulars. While the flattening and kinematics of the system of metal-rich clusters suggest a disk, the more metal-poor clusters reveal little evidence for rotation. It is noted that the flattening of the system of metal-poor and intermediate clusters resembles that of the M31 spheroid, and that the effective radius of the intermediate system also resembles that of the spheroid.

Elson, Rebecca A.↗

Cerebrospinal fluid constituents of cat vary with susceptibility to motion sickness

The cerebrospinal fluid drawn from the fourth ventricles of the brains of cats during and after the development of motion sickness was studied to determine what neurotransmitters may be involved in the development of the sickness. The analytical procedure, which uses HPLC coupled with n-electrode coulometric electrochemical detection to measure many compounds with picogram sensitivity, is described. Baseline levels of DOPAC, MHPGSO4, uric acid, DA, 5-HIAA, and HVA were lower on motion and control days in cats which became motion sick when compared with cats which did not. None of the total of 36 identified compounds identified in the samples varied as a function of either exposure to motion or provocation of emesis. It is concluded that susceptibility to motion sickness is a manifestation of individual differences related to fundamental neurochemical composition.

Lucot, James B.↗

LV software support for supersonic flow analysis

During 1991, the software developed allowed an operator to configure and checkout the TSI, Inc. laser velocimeter (LV) system prior to a run. This setup procedure established the operating conditions for the TSI MI-990 multichannel interface and the RMR-1989 rotating machinery resolver. In addition to initializing the instruments, the software package provides a means of specifying LV calibration constants, controlling the sampling process, and identifying the test parameters.

Bell, William A.↗

CFD Code Survey for Thrust Chamber Application

In the quest fo find analytical reference codes, responses from a questionnaire are presented which portray the current computational fluid dynamics (CFD) program status and capability at various organizations, characterizing liquid rocket thrust chamber flow fields. Sample cases are identified to examine the ability, operational condition, and accuracy of the codes. To select the best suited programs for accelerated improvements, evaluation criteria are being proposed.

Gross, Klaus W.↗

Effect of Temperature and Deformation Rate on the Tensile Mechanical Properties of Polyimide Films

In order to study the structure-property relationships of different processed oriented polyimide films, the mechanical properties will be identified by using tensile tester Instron 4505 and structural information such as the 3-dimensional birefringence molecular symmetry axis and 3-dimensional refractive indices will be determined by using wave guide coupling techniques. The monoaxial drawing techniques utilized in this research are very useful for improving the tensile mechanical properties of aromatic polyimide films. In order to obtain high modulus/high strength polyimide films the following two techniques have been employed, cold drawing in which polyimide films are drawn at room temperature at different cross head speeds and hot drawing in which polyimide films are drawn at different temperatures and cross head speeds. In the hot drawing process the polyimide films are drawn at different temperatures until the glass transition temperature (Tg) is reached by using the environmental chamber. All of the mechanical and optical property parameters will be identified for each sample processed by both cold and hot drawing techniques.

Moghazy, Samir F.↗

BATSE imaging survey of the Galactic plane

The burst and transient source experiment (BATSE) onboard the Compton Gamma Ray Observatory (CGRO) provides all sky monitoring capability, occultation analysis and occultation imaging which enables new and fainter sources to be searched for in relatively crowded fields. The occultation imaging technique is used in combination with an automated BATSE image scanner, allowing an analysis of large data sets of occultation images for detections of candidate sources and for the construction of source catalogs and data bases. This automated image scanner system is being tested on archival data in order to optimize the search and detection thresholds. The image search system, its calibration results and preliminary survey results on archival data are reported on. The aim of the survey is to identify a complete sample of black hole candidates in the galaxy and constrain the number of black hole systems and neutron star systems.

Grindlay, J. E.↗

Development of a Deltoid Shoulder Muscle Model for Rhesus Monkey Spaceflight Studies

The acromiodeltoid shoulder muscle was demonstrated to be a suitable model for spaceflight studies. The muscle contains a mixture of fast and slow fibers, permitting analysis of muscle fiber type specific changes. Two biopsy sites per muscle were identified that provided samples not degraded by the biopsy procedure. Both sites contained sufficient numbers fibers for determining changes in fiber type percentages and size. There was adequate bilateral symmetry regarding fiber type composition in the left and right muscles such that a total of four times points can be compared. The ESOP cage did not cause atrophy of deltoid muscle fibers; this means that microgravity-induced atrophy should be detectable. As expected, muscle excision stimulated muscle IgM and IgG muscle autoantibody production. Nonrestrained control animals suppressed this response whereas restrained monkeys showed an abnormally pronounced response indicative a compromised immune system. The presence of ESOP cage-induced changes in the immune response may mask spaceflight-induced effects. The ESOP cage modified the dominant hand operation of the PTS. These results demonstrate the importance of high fidelity ground based controls.

Riley, Danny A.↗

Comparison of ER-2 Aircraft and POAM-III, MLS, and SAGE-II Satellite Measurements During SOLVE Using Traditional Correlative Analysis and Trajectory Hunting Technique

We compared the version 5 Microwave Limb Sounder (MLS) aboard the Upper Atmosphere Research Satellite (UARS), version 3 Polar Ozone and Aerosol Measurement-III (POAM-111) aboard the French satellite SPOT-IV, version 6.0 Stratospheric Aerosol and Gas Experiment 11 (SAGE-II) aboard the Earth Radiation Budget Satellite, and NASA ER-2 aircraft measurements made in the northern hemisphere in January-February 2000 during the SAGE III Ozone Loss and Validation Experiment (SOLVE). This study addresses one of the key scientific objectives of the SOLVE campaign, namely, to validate multi-platform satellite measurements made in the polar stratosphere during winter. This intercomparison was performed using a traditional correlative analysis (TCA) and a trajectory hunting technique (THT). Launching backward and forward trajectories from the points of measurement, the THT identifies air parcels sampled at least twice within a prescribed match criterion during the course of 5 days. We found that the ozone measurements made by these four instruments agree most of the time within 110% in the stratosphere up to 1400 K (approximately 35 km). The water vapor measurements from POAM-III and the ER-2 Harvard Lyman-alpha hygrometer and JPL laser hygrometer agree to within 10.5 ppmv (or about +/-10%) in the lower stratosphere above 380 K. The MLS and ER-2 ClO measurements agree within their error bars for the TCA. The MLS and ER-2 nitric acid measurements near 17-20 km altitude agree within their uncertainties most of the time with a hint of a positive offset by MLS according to the TCA. We also applied the AER box model constrained by the ER-2 measurements for analysis of the ClO and HN03 measurements using the THT. We found that: (1) the model values of ClO are smaller by about 0.3-0.4 (0.2) ppbv below (above) 400 K than those by MLS and (2) the HN03 comparison shows a positive offset of MLS values by approximately 1 and 1-2 ppbv below 400 K and near 450 K, respectively. It is hard to quantify the HN03 offset in the 400-440 K range because of the high sensitivity of nitric acid to the PSC schemes. Our study shows that, with some limitations (like HN03 comparison under PSC conditions), the THT is a more powerful tool for validation studies than the TCA, making conclusions of the comparison statistically more robust.

Danilin, M. Y.↗

Phase-Imaging with a Sharpened Multi-Walled Carbon Nanotube AFM Tip: Investigation of Low-k Dielectric Polymer Hybrids

Phase shift tapping mode scanning force microscopy (TMSFM) has evolved into a very powerful technique for the nanoscale surface characterization of compositional variations in heterogeneous samples. Phase shift signal measures the difference between the phase angle of the excitation signal and the phase angle of the cantilever response. The signal correlates to the tip-sample inelastic interactions, identifying the different chemical and/or physical property of surfaces. In general, the resolution and quality of scanning probe microscopic images are highly dependent on the size of the scanning probe tip. In improving AFM tip technology, we recently developed a technique for sharpening the tip of a multi-walled carbon nanotube (CNT) AFM tip, reducing the radius of curvature of the CNT tip to less than 5 nm while still maintaining the inherent stability of multi-walled CNT tips. Herein we report the use of sharpened (CNT) AFM tips for phase-imaging of polymer hybrids, a precursor for generating nanoporous low-k dielectrics for on-chip interconnect applications. Using sharpened CNT tips, we obtained phase-contrast images having domains less than 10 nm. In contrast, conventional Si tips and unsharpened CNT tips (radius greater than 15 nm) were not able to resolve the nanoscale domains in the polymer hybrid films. C1early, the size of the CNT tip contributes significantly to the resolution of phase-contrast imaging. In addition, a study on the nonlinear tapping dynamics of the multi-walled CNT tip indicates that the multi-walled CNT tip is immune to conventional imaging instabilities related to the coexistence of attractive and repulsive tapping regimes. This factor may also contribute to the phase-contrast image quality of multi-walled CNT AFM tips. This presentation will also offer data in support of the stability of the CNT tip for phase shift TMSFM.

Nguyen, Cattien V.↗

Pressure Flammability Thresholds of Selected Aerospace Materials

A test program was performed to determine the highest pressure in oxygen where materials used in the planned NASA Constellation Program Orion Crew Exploration Vehicle (CEV) Crew Module (CM) would not propagate a flame if an ignition source was present. The test methodology used was similar to that previously used to determine the maximum oxygen concentration (MOC) at which self-extinguishment occurs under constant total pressure conditions. An upward limiting pressure index (ULPI) was determined, where approximately 50 percent of the materials self-extinguish in a given environment. Following this, the maximum total pressure (MTP) was identified; where all samples tested (at least five) self-extinguished following the NASA-STD-6001.A Test 1 burn length criteria. The results obtained on seven materials indicate that the non-metallic materials become flammable in oxygen between 0.4 and 0.9 psia.

Hirsch, David B.↗

The Evolution of Ly-alpha Emitting Galaxies Between z = 2.1 and z = 3.l

We describe the results of a new, wide-field survey for z= 3.1 Ly-alpha emission-line galaxies (LAEs) in the Extended Chandra Deep Field South (ECDF-S). By using a nearly top-hat 5010 Angstrom filter and complementary broadband photometry from the MUSYC survey, we identify a complete sample of 141 objects with monochromatic fluxes brighter than 2.4E-17 ergs/cm^2/s and observers-frame equivalent widths greater than ~ 80 Angstroms (i.e., 20 Angstroms in the rest-frame of Ly-alpha). The bright-end of this dataset is dominated by x-ray sources and foreground objects with GALEX detections, but when these interlopers are removed, we are still left with a sample of 130 LAE candidates, 39 of which have spectroscopic confirmations. This sample overlaps the set of objects found in an earlier ECDF-S survey, but due to our filter's redder bandpass, it also includes 68 previously uncataloged sources. We confirm earlier measurements of the z=3.1 LAE emission-line luminosity function, and show that an apparent anti-correlation between equivalent width and continuum brightness is likely due to the effect of correlated errors in our heteroskedastic dataset. Finally, we compare the properties of z=3.1 LAEs to LAEs found at z=2.1. We show that in the approximately 1 Gyr after z approximately 3, the LAE luminosity function evolved significantly, with L * fading by approximately 0.4 mag, the number density of sources with L greater than 1.5E42 ergs/s declining by approximately 50%, and the equivalent width scalelength contracting from 70^{+7}_{-5} Angstroms to 50^{+9}_{-6} Angstroms. When combined with literature results, our observations demonstrate that over the redshift range z approximately 0 to z approximately 4, LAEs contain less than approximately 10% of the star-formation rate density of the universe.

Ciardullo, Robin↗

Examples of Optical Assessment of Surface Cleanliness of Genesis Samples

Optical microscope assessment of Genesis solar wind collector surfaces is a coordinated part of the effort to obtain an assessed clean subset of flown wafer material for the scientific community. Microscopic survey is typically done at 50X magnification at selected approximately 1 square millimeter areas on the fragment surface. This survey is performed each time a principle investigator (PI) returns a sample to JSC for documentation as part of the established cleaning plan. The cleaning plan encompasses sample handling and analysis by Genesis science team members, and optical survey is done at each step in the process. Sample surface cleaning is performed at JSC (ultrapure water [1] and UV ozone cleaning [2]) and experimentally by other science team members (acid etch [3], acetate replica peels [4], CO2 snow [5], etc.). The documentation of each cleaning method can potentially be assessed with optical observation utilizing Image Pro Plus software [6]. Differences in particle counts can be studied and discussed within analysis groups. Approximately 25 samples have been identified as part of the cleaning matrix effort to date.

Rodriquez, Melissa C.↗

A Comparison of Anorthositic Lunar Lithologies: Variation on the FAN Theme

Certain anorthositic rocks that are rare in the returned lunar samples have been identified among lunar meteorites. The variety of anorthosites in the Apollo collection also is more varied than is widely recognized. James eta. identified three lithologies in a composite clast o ferroan anorthosite (FAN)-suite rocks in lunar breccia 64435. They further divided all FANs into four subgroups: anorthositic ferroan (AF), mafic magnesian (MM), mafic ferroan (MF), and anorthositic sodic (AS, absent in the 64435 clast). Here we report Sm-Nd isotopic studies of the lithologies present in the 64435 composite clast and compare the new data to our previous data for lunar anorthosites incuding lunar anorthositic meteorites. Mineralogy-petrography, in situ trace element studies, Sr-isotope studies, and Ar-Ar chronology are included, but only the Nd-isotopic studies are currently complete.

Nyquist, L. E.↗