Search NASA⌕ Search

SEARCH · Search NASA

Results for “software compatibility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

LIP: The Livermore Interpolation Package, Version 1.4

This report describes LIP, the Livermore Interpolation Package. Because LIP is a stand-alone version of the interpolation package in the Livermore Equation of State (LEOS) access library, the initials LIP alternatively stand for the 'LEOS Interpolation Package'. LIP was totally rewritten from the package described in [1]. In particular, the independent variables are now referred to as x and y, since the package need not be restricted to equation of state data, which uses variables {rho} (density) and T (temperature). LIP is primarily concerned with the interpolation of two-dimensional data on a rectangular mesh. The interpolation methods provided include piecewise bilinear, reduced (12-term) bicubic, and bicubic Hermite (biherm). There is a monotonicity-preserving variant of the latter, known as bimond. For historical reasons, there is also a biquadratic interpolator, but this option is not recommended for general use. A birational method was added at version 1.3. In addition to direct interpolation of two-dimensional data, LIP includes a facility for inverse interpolation (at present, only in the second independent variable). For completeness, however, the package also supports a compatible one-dimensional interpolation capability. Parametric interpolation of points on a two-dimensional curve can be accomplished by treating the components as a pair of one-dimensional functions with a common independent variable. LIP has an object-oriented design, but it is implemented in ANSI Standard C for efficiency and compatibility with existing applications. First, a 'LIP interpolation object' is created and initialized with the data to be interpolated. Then the interpolation coefficients for the selected method are computed and added to the object. Since version 1.1, LIP has options to instead estimate derivative values or merely store data in the object. (These are referred to as 'partial setup' options.) It is then possible to pass the object to functions that interpolate or invert the interpolant at an arbitrary number of points. The first section of this report describes the overall design of the package, including both forward and inverse interpolation. Sections 2-6 describe each interpolation method in detail. The software that implements this design is summarized function-by-function in Section 7. For a complete example of package usage, refer to Section 8. The report concludes with a few brief notes on possible software enhancements. For guidance on adding other functional forms to LIP, refer to Appendix B. The reader who is primarily interested in using LIP to solve a problem should skim Section 1, then skip to Sections 7.1-4. Finally, jump ahead to Section 8 and study the example. The remaining sections can be referred to in case more details are desired. Changes since version 1.1 of this document include the new Section 3.2.1 that discusses derivative estimation and new Section 6 that discusses the birational interpolation method. Section numbers following the latter have been modified accordingly.

97 MATHEMATICS AND COMPUTING↗

Strain and lattice orientation distribution in SiN/Ge complementary metal–oxide–semiconductor compatible light emitting microstructures by quick x-ray nano-diffraction microscopy

This paper presents a study of the spatial distribution of strain and lattice orientation in CMOS-fabricated strained Ge microstripes using high resolution x-ray micro-diffraction. The recently developed model-free characterization tool, based on a quick scanning x-ray diffraction microscopy technique can image strain down to levels of 10{sup −5} (Δa/a) with a spatial resolution of ∼0.5 μm. Strain and lattice tilt are extracted using the strain and orientation calculation software package X-SOCS. The obtained results are compared with the biaxial strain distribution obtained by lattice parameter-sensitive μ-Raman and μ-photoluminescence measurements. The experimental data are interpreted with the help of finite element modeling of the strain relaxation dynamics in the investigated structures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

ATLAS: a Snakemake workflow for assembly, annotation, and genomic binning of metagenome sequence data

Background: Metagenomics and metatranscriptomics studies provide valuable insight into the composition and function of microbial populations from diverse environments, however the data processing pipelines that rely on mapping reads to gene catalogs or genome databases for cultured strains yield results that underrepresent the genes and functional potential of uncultured microbes. Recent improvements in sequence assembly methods have eased the reliance on genome databases, thereby allowing the recovery of genomes from uncultured microbes. However, configuring these tools, linking them with advanced binning and annotation tools, and maintaining provenance of the processing continues to be challenging for researchers. Results: Here we present ATLAS, a software package for customizable data processing from raw sequence reads to functional and taxonomic annotations using state-of-the-art tools to assemble, annotate, quantify, and bin metagenome and metatranscriptome data. Genome-centric resolution and abundance estimates are provided for each sample in a dataset. ATLAS is written in Python and the workflow implemented in Snakemake; it operates in a Linux environment, and is compatible with Python 3.5+ and Anaconda 3+ versions. The source code for ATLAS is freely available, distributed under a BSD-3 license. Conclusions: ATLAS provides a user-friendly, modular and customizable Snakemake workflow for metagenome and metatranscriptome data processing; it is easily installable with conda and maintained as open-source on GitHub at https://github.com/metagenome-atlas/atlas.

59 BASIC BIOLOGICAL SCIENCES↗

Quantitative Imaging with a Mobile Phone Microscope

Use of optical imaging for medical and scientific applications requires accurate quantification of features such as object size, color, and brightness. High pixel density cameras available on modern mobile phones have made photography simple and convenient for consumer applications; however, the camera hardware and software that enables this simplicity can present a barrier to accurate quantification of image data. This issue is exacerbated by automated settings, proprietary image processing algorithms, rapid phone evolution, and the diversity of manufacturers. If mobile phone cameras are to live up to their potential to increase access to healthcare in low-resource settings, limitations of mobile phone–based imaging must be fully understood and addressed with procedures that minimize their effects on image quantification. Here we focus on microscopic optical imaging using a custom mobile phone microscope that is compatible with phones from multiple manufacturers. We demonstrate that quantitative microscopy with micron-scale spatial resolution can be carried out with multiple phones and that image linearity, distortion, and color can be corrected as needed. Using all versions of the iPhone and a selection of Android phones released between 2007 and 2012, we show that phones with greater than 5 MP are capable of nearly diffraction-limited resolution over a broad range of magnifications, including those relevant for single cell imaging. We find that automatic focus, exposure, and color gain standard on mobile phones can degrade image resolution and reduce accuracy of color capture if uncorrected, and we devise procedures to avoid these barriers to quantitative imaging. By accommodating the differences between mobile phone cameras and the scientific cameras, mobile phone microscopes can be reliably used to increase access to quantitative imaging for a variety of medical and scientific applications.

59 BASIC BIOLOGICAL SCIENCES↗

Berkeley Unified Parallel C (UPC) runtime library

This software comprises a portable, open-source implementation of a runtime library to support applications written in the Unified Parallel C (UPC) language. This library implements the UPC-specific functionality, including shared-memory allocation and distributed locks. The network-dependent functionality is implemented as a thin wrapper around the separate GASNet (Global-Address Space Networking) library, which is required for operation. This software implements the "Berkeley UPC Runtime Specification", which is targeted by at least four separate UPC compiler front-ends. The implementation is highly portable and runs over hardware ranging from laptops to custom supercomputers. An external library is required for certain local memory allocation operations; a well-defined interface allows for multiple implementations of this library, but at present the "umalloc" library from LBNL is the only compatible implementation.

Bonachea, Dan↗

Los Angeles Air Force Base Vehicle-to-Grid Demonstration (Final Project Report)

Electrification of non-tactical vehicle fleets represents a key efficiency and energy security objective for the United States Department of Defense. To achieve electrification, the department targeted vehicle-to-grid services as a way to decrease the overall cost of operating the vehicle fleet and achieve rough parity with traditional internal combustion engine vehicle fleets. This report describes efforts to aggregate a fleet of bi-directional electric vehicles and charging stations to provide regulation up and regulation down in the California Independent System Operator ancillary services market. A 29-vehicle electric vehicle demonstration fleet, consisting of mixed purpose and duty vehicles such as sedans, pickups, vans, and medium-duty trucks, was deployed at the Los Angeles Air Force base. The fleet provided frequency regulation to the California Independent System Operator’s wholesale electricity market to determine the capability of recouping some of the additional costs of procuring electric vehicles and their supporting infrastructure. Lawrence Berkeley National Laboratory, with its partner Kisensum, LLC, developed the fleet scheduling, optimization, and control software to allow the vehicle fleet at the air force base to participate in the ancillary services markets. This report focuses on the control software and market interactions, the significant challenges faced and solutions devised to address them, and examines the potential of using the electric vehicle fleet as an energy storage resource for the base buildings, an application known as vehicle-tobuilding, in providing demand response and emergency backup power. The report discusses key findings related to providing frequency regulation to the California Independent System Operator market, electric vehicle fleet performance, compatibility of varying resource parameters of vehicle fleet aggregation, the need for automated methods for communicating hour-ahead energy bidding, challenges related to battery capacity and charge/discharge rates, and monthly settlement revenue.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Docker Containers for MCNP ® Development

Containers are a revolutionary technology in software development and deployment that provides a lightweight, portable environment for ensuring consistency across multiple computing environments. In anticipation of the MCNP 6.3.1 release, two Docker container images have been released on DockerHub for general use. The MCNP source code is not included in the images, and users are still required to obtain it through RSICC. The images produced by Docker are compliant with the OCI (Open Container Initiative) standards, ensuring compatibility with other container engines such as Podman or Kubernetes’ CRI-O. Initially, the images are stored under the author’s personal space on DockerHub (docker.io/azukaitis), but they will be relocated to a dedicated MCNP group space once approved. In the future, they will also be available through the registry feature of the https://github.com/lanl/mcnp-containers project. The use of Docker provides a pre-configured environment for building and running MCNP, ensuring reproducibility of results across various host architectures. This significantly improves consistency when running MCNP on different systems. Notably, executables and installers from the Docker images have successfully passed the MCNP development branch testing suite on x86-64 architectures, including Windows, macOS, and Linux operating systems. Furthermore, testing has demonstrated compatibility with macOS Docker in emulation mode on the latest Apple Mac M2 Ultra hardware, ensuring robust support even on the latest platforms. In this document, we will provide a step-by-step guide to using the Docker images across multiple platforms. Additionally, we will present performance numbers for building and running the MCNP test suite.

97 MATHEMATICS AND COMPUTING↗

MTUQ: a framework for estimating moment tensors, point forces, and their uncertainties

SUMMARY We introduce MTUQ, an open-source Python package for seismic source estimation and uncertainty quantification, emphasizing flexibility and operational scalability. MTUQ provides MPI-parallelized grid search and global optimization capabilities, compatibility with 1-D and 3-D Green’s function database formats, customizable data processing, C-accelerated waveform and first-motion polarity misfit functions, and utilities for plotting seismic waveforms and visualizing misfit and likelihood surfaces. Applicability to a range of full- and constrained-moment tensor, point force, and centroid inversion problems is possible via a documented application programming interface, accompanied by example scripts and integration tests. We demonstrate the software using three different types of seismic events: (1) a 2009 intraslab earthquake near Anchorage, Alaska; (2) an episode of the 2021 Barry Arm landslide in Alaska; and (3) the 2017 Democratic People’s Republic of Korea underground nuclear test. With these events, we illustrate the well-known complementary character of body waves, surface waves, and polarities for constraining source parameters. We also convey the distinct misfit patterns that arise from each individual data type, the importance of uncertainty quantification for detecting multimodal or otherwise poorly constrained solutions, and the software’s flexible, modular design.

58 GEOSCIENCES↗

The Multi-Isotope Process (MIP) Monitor Project: FY12 Progress and Accomplishments

The Multi-Isotope Process (MIP) Monitor, being developed at Pacific Northwest National Laboratory (PNNL), provides an efficient approach to monitoring the process conditions in reprocessing facilities in support of the goal of "...(minimization of) the risks of nuclear proliferation and terrorism." The MIP Monitor measures distributions of a suite of indicator (radioactive) isotopes present within product and waste streams of a nuclear reprocessing facility. These indicator isotopes are monitored on-line by gamma spectrometry and compared, in near-real-time, to spectral patterns representing "normal" process conditions using multivariate pattern recognition software. The monitor utilizes this multivariate analysis and gamma spectroscopy of reprocessing streams to detect small changes in the gamma spectrum, which may indicate changes in process conditions. Multivariate analysis methods common in chemometrics, such as principal component analysis (PCA) and partial least squares regression (PLS), act as pattern recognition techniques, which can detect small deviations from the expected, nominal condition. By targeting multiple gamma-emitting indicator isotopes, the MIP Monitor approach is compatible with the use of small, portable, relatively high-resolution gamma detectors that may be easily deployed throughout an existing facility. The automated multivariate analysis can provide a level of data obscurity, giving a built-in information barrier to protect sensitive or proprietary operational data. Proof-of-concept simulations and experiments have been performed in previous years to demonstrate the validity of this tool in a laboratory setting. Development of the MIP Monitor approach continues to evaluate the efficacy of the monitor for automated, real-time or near-real-time application. This report details follow-on research and development efforts sponsored by the U.S. Department of Energy Fuel Cycle Research and Development related to the MIP Monitor for fiscal year 2012 (FY12).

fuel characterization↗

Specification of the Advanced Burner Test Reactor Multi-Physics Coupling Demonstration Problem

This document specifies the multi-physics nuclear reactor demonstration problem using the SHARP software package developed by NEAMS. The SHARP toolset simulates the key coupled physics phenomena inside a nuclear reactor. The PROTEUS neutronics code models the neutron transport within the system, the Nek5000 computational fluid dynamics code models the fluid flow and heat transfer, and the DIABLO structural mechanics code models structural and mechanical deformation. The three codes are coupled to the MOAB mesh framework which allows feedback from neutronics, fluid mechanics, and mechanical deformation in a compatible format.

97 MATHEMATICS AND COMPUTING↗

Intelligent Experiments through Real-Time AI: Fast Data Processing and Autonomous Detector Control for High-Energy Nuclear Experiments

The aim of this project is to develop software and hardware for fast real-time data processing and autonomous detector control and calibration for the sPHENIX and the future EIC experiments. Below summarizes Georgia Tech team efforts in the past year: 1. We developed a real-time clustering algorithm and FPGA-based pipeline architecture for processing fired pixel data from ALPIDE sensors in sPHENIX experiments. Our Columnar Clustering Co-Design introduces a hardware-aware, stream-friendly approach that segments pixel data by column pairs using a Column Pair Clustering (CPC) strategy, followed by Cluster Stitching to merge adjacent subclusters. Implemented in Vitis HLS, the pipeline comprises five stages—read-in, subclustering, stitching, analysis, and write-out—connected by tagged HLS streams with custom end-of-event signaling for robust synchronization. We designed a pipelined dataflow model optimized for throughput, low latency, and minimal buffering, enabling scalable clustering across events of arbitrary size. Our system maintains spatial precision via center-of-mass and shape key extraction and efficiently handles edge cases such as fragmented or nested clusters. Compared against DBSCAN in both software and hardware, our approach demonstrates competitive performance under FPGA constraints. 2. We also conducted a comprehensive algorithm-to-hardware co-design of connected component analysis tailored for sPHENIX experiments, focusing on real-time, low-latency processing using FPGAs and High-Level Synthesis (HLS). Starting from a Python-based particle tracking pipeline, the team translated the core logic—graph traversal via DFS and Union-Find—into an HLS-compatible C++ model, replacing dynamic memory and recursion with static arrays and pipelined control flow. The final design includes a fully streamed and dataflow-compatible Union-Find kernel optimized across five iterations, incorporating loop pipelining, array partitioning, AXI/FIFO interface tuning, and function flattening. Experimental results show up to 14.8× speedup over the CPU baseline, reducing per-graph latency to 1.58 μs and demonstrating strong resource efficiency with only ~7k LUTs and zero BRAM usage. The design maintains functional correctness against the Python reference using a Python-based C-simulation framework and Mean Squared Error metrics. This work validates the potential of HLS-driven FPGA designs for edge-level HEP data acquisition, laying a scalable foundation for future integration with real-time detector pipelines and multi-graph processing systems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Enhancing Monte Carlo Workflows for Nuclear Reactor Analysis with Metamodel-Driven Modeling

Monte Carlo codes are essential components of many reactor physics simulation workflows as high-fidelity continuous-energy neutron transport solvers. Among Monte Carlo radiation transport codes, MCNP is particularly notable due to its diverse simulation capabilities, large user base, and long validation history. Despite being a powerful simulation tool, MCNP provides limited capabilities to allow automated execution, model transformation, or support for user-defined logic and abstractions that limit its compatibility with modern workflows. Here, to better integrate MCNP into a modern scientific workflow, we have developed an intuitive yet full-featured MCNP Application Program Interface (API) in Python, named MCNPy, which provides a specialized set of classes for MCNP input development. Moreover, to guarantee that our reading, writing, and modeling capabilities remain self-consistent (and to render the huge scope of the MCNP API manageable), we have adopted a strategy of model-driven software development in which a generalized model of the MCNP input format has been created. From this generalized model, or “metamodel,” problem-specific implementations such as an engine for input validation or a codebase for programmatic operations may be automatically generated. Since MCNPy primarily acts as a Python front-end to the underlying Java API that directly interfaces with the metamodel, it is intrinsically linked to the metamodel and thus remains maintainable. With MCNPy, users can programmatically read, write, and modify any syntactically valid MCNP input file regardless of its origin. These capabilities allow users to automate complicated tasks like design optimization and model translation for nuclear systems. As examples, this work demonstrates the use of MCNPy to find the critical radius of a plutonium sphere and to translate a 9000+ line MCNP input file into a corresponding OpenMC model.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SU-E-I-02: A Framework to Perform Batch Simulations of Computational Voxel Phantoms to Study Organ Doses in Computed Tomography Using a Commercial Monte Carlo Software Package

Purpose: ImpactMC (CT Imaging, Erlangen, Germany) is a Monte Carlo (MC) software package that offers a GPU enabled, user definable and validated method for 3D dose distribution calculations for radiography and Computed Tomography (CT). ImpactMC, in and of itself, offers limited capabilities to perform batch simulations. The aim of this work was to develop a framework for the batch simulation of absorbed organ dose distributions from CT scans of computational voxel phantoms. Methods: The ICRP 110 adult Reference Male and Reference Female computational voxel phantoms were formatted into compatible input volumes for MC simulations. A Matlab (The MathWorks Inc., Natick, MA) script was written to loop through a user defined set of simulation parameters and 1) generate input files required for the simulation, 2) start the MC simulation, 3) segment the absorbed dose for organs in the simulated dose volume and 4) transfer the organ doses to a database. A demonstration of the framework is made where the glandular breast dose to the adult Reference Female phantom, for a typical Chest CT examination, is investigated. Results: A batch of 48 contiguous simulations was performed with variations in the total collimation and spiral pitch. The demonstration of the framework showed that the glandular dose to the right and left breast will vary depending on the start angle of rotation, total collimation and spiral pitch. Conclusion: The developed framework provides a robust and efficient approach to performing a large number of user defined MC simulations with computational voxel phantoms in CT (minimal user interaction). The resulting organ doses from each simulation can be accessed through a database which greatly increases the ease of analyzing the resulting organ doses. The framework developed in this work provides a valuable resource when investigating different dose optimization strategies in CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CodeScribe Agent

SF-26-086 CodeScribe introduces a structured, multi-stage pipeline that combines deterministic program analysis with LLM-powered translation to enable incremental, testable Fortran-to-C++ migration. First, `code-scribe index` traverses the project directory tree and produces `scribe.yaml` metadata files recording all modules, subroutines, and functions at each level, giving the LLM accurate structural context instead of a hallucinated codebase model. Second, `code-scribe draft` performs the deterministic portion of translation — converting Fortran types to C++ equivalents, replacing `use` statements with `#include` and `using namespace` directives, and detecting constructs requiring special handling — while embedding`scribe-prompt` annotations that guide the LLM through non-trivial cases such as statement-function-to-lambda conversions and `extern "C"` wrapper generation. Third, `code-scribe translate` applies project-specific TOML-based few-shot prompt templates and submits the composed prompt to a pluggable LLM backend (OpenAI, Anthropic, Argonne ARGO, any OpenAI-compatible endpoint, or local Hugging Face checkpoints), producing a C++ source file, a header, and a Fortran-C++ interface file for each translated routine so the codebase compiles and runs correctly throughout the migration. Beyond translation, CodeScribe includes a tool-using coding agent (`code-scribe agent`) with read, bash, edit, and write capabilities, and a bounded loop mode (`code-scribe loop`) that runs repeated stateless agent sessions over a task file with restricted tool access — enabling sustained, auditable software development workflows for broader scientific computing tasks.

Dhruv, Akash [Argonne National Laboratory (ANL), A↗

Measurement of oxidative stress parameters using liquid chromatography-tandem mass spectroscopy (LC-MS/MS)

There is increasingly intense scientific and clinical interest in oxidative stress and the many parameters used to quantify the degree of oxidative stress. However, there remain many analytical limitations to currently available assays for oxidative stress markers. Recent improvements in software, hardware, and instrumentation design have made liquid chromatography and tandem mass spectroscopy (LC-MS/MS) methods optimal choices for the determination of many oxidative stress markers. In particular, LC-MS/MS often provides the advantages of higher specificity, higher sensitivity, and the capacity to determine multiple analytes (e.g. 4-11 oxidative stress markers per LC run) when compared to other available methods, such as gas chromatography-MS, immunoassays, spectrophotometric or flourometric assays. LC-MS/MS methods are also compatible with cleanup and sample preparation methods including prior solid phase extraction or automated two dimensional LC/LC chromatography followed by MS/MS. LC-MS/MS provides three analytical filtering functions: (1) the LC column provides initial separation as each analyte elutes from the column. (2) The first MS dimension isolates ions of a particular mass-to-charge (m/z) ratio. (3) The selected precursor ion is fragmented into product ions that provide structural information about the precursor ion. Quantitation is achieved based on the abundances of the product ions. The sensitivity limits for LC-MS/MS usually lie within the range of fg-pg of analyte per LC on-column injection. In this article, the present capabilities of LC-MS/MS are briefly presented and some specific examples of the strengths of these LC-MS/MS assays are discussed. The selected examples include methods for isoprostanes, oxidized proteins and amino acids, and DNA biomarkers of oxidative stress.

60 APPLIED LIFE SCIENCES↗

International database of reference gamma spectra for nuclear safeguards applications

Nuclear safeguards missions use gamma spectroscopy as a non-destructive measurement technique for examining nuclear materials. Despite advances in the development of detection equipment as well as software codes, one of the concerns is the lack of well-documented spectra needed to test and validate isotopic analysis codes for their applicability. To address this need, this work introduces IDB, an international database of the reference gamma spectra of uranium, plutonium and mixed oxide nuclear material samples. IDB provides access to well-characterized sets of gamma spectra described by rich metadata, including information on the sample, measurement configuration and detector specifications. These spectra are accessible in different formats, also compatible with analysis code standards, thus promoting their sustainability and maintenance.

None, Dipti [International Atomic Energy Agency (I↗

DeconMSn: A Software Tool for accurate parent ion monoisotopic mass determination for tandem mass spectra

We present a new software tool for tandem MS analyses that: • accurately calculates the monoisotopic mass and charge of high–resolution parent ions • accurately operates regardless of the mass selected for fragmentation • performs independent of instrument settings • enables optimal selection of search mass tolerance for high mass accuracy experiments • is open source and thus can be tailored to individual needs • incorporates a SVM-based charge detection algorithm for analyzing low resolution tandem MS spectra • creates multiple output data formats (.dta, .MGF) • handles .RAW files and .mzXML formats • compatible with SEQUEST, MASCOT, X!Tandem

Mayampurath, Anoop M.↗

TH-C-17A-05: Cherenkov Excited Phosphorescence Oxygen (CEPhOx) Imaging During Multi-Beam Radiation Therapy

Purpose: Cherenkov radiation is created during external beam radiation therapy that can excite phosphorescence in tissue from oxygen-sensitive, bio-compatible probes. Utilizing the known spatial information of the treatment plan with directed multiple beam angles, Cherenkov Excited Phosphorescence Oxygen (CEPhOx) imaging was realized from the reconstructions of Cherenkov excited phosphorescence lifetime. Methods: Platinum(II)-G4 (PtG4) was used as the oxygen-sensitive phosphorescent probe and added to a oxygenated cylindrical liquid phantom with a oxygenated/deoxygenated cylindrical anomaly. Cherenkov excited phosphorescence was imaged using a time-gated ICCD camera temporallysynchronized to the LINAC pulse output. Lifetime reconstruction was carried out in NIRFAST software. Multiple angles of the incident radiation beam was combined with the location of the prescribed treatment volume (PTV) to improve the tomographic recovery as a function of location. The tissue partial pressure of oxygen (pO2) in the background and PTV was calculated based on the recovered lifetime distribution and Stern-Volmer equation. Additionally a simulation study was performed to examine the accuracy of this technique in the setting of a human brain tumor. Results: Region-based pO2 values in the oxygenated background and oxygenated/deoxygenated PTV were correctly recovered, with the deoxygenated anomaly (15.4 mmHg) easily distinguished from the oxygenated background (143 mmHg). The data acquisition time could be achieved within the normal irradiation time for a human fractionated plan. The simulations indicated that CEPhOx would be a sufficient to sample tumor pO2 sensing from tumors which are larger than 2cm in diameter or within 23mm depth from the surface. Conclusion: CEPhOx could be a novel imaging tool for pO2 assessment during external radiation beam therapy. It is minimally invasive and should work within the established treatment plan of radiation therapy with multiple beams in situations where tumor pO2 measurement is a pertinent radiotherapy efficiency and dosimetric need.

07 ISOTOPE AND RADIATION SOURCES↗