Search NASA⌕ Search

SEARCH · Search NASA

Results for “structural mount”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Cloning, expression, purification, crystallization and preliminary X-ray crystallographic analysis of the mannose 6-phosphate isomerase from Salmonella typhimurium

The cloning, expression, purification, crystallization and preliminary X-ray crystallographic studies of mannose 6-phosphate isomerase from S. typhimurium are reported. Mannose 6-phosphate isomerase (MPI; EC 5.3.1.8) catalyzes the reversible isomerization of d-mannose 6-phosphate (M6P) and d-fructose 6-phosphate (F6P). In the eukaryotes and prokaryotes investigated to date, the enzyme has been reported to play a crucial role in d-mannose metabolism and supply of the activated mannose donor guanosine diphosphate d-mannose (GDP-d-mannose). In the present study, MPI was cloned from Salmonella typhimurium, overexpressed in Escherichia coli and purified using Ni–NTA affinity column chromatography. Purified MPI crystallized in space group P2{sub 1}2{sub 1}2{sub 1}, with unit-cell parameters a = 36.03, b = 92.2, c = 111.01 Å. A data set extending to 1.66 Å resolution was collected with 98.8% completeness using an image-plate detector system mounted on a rotating-anode X-ray generator. The asymmetric unit of the crystal cell was compatible with the presence of a monomer of MPI. A preliminary structure solution of the enzyme has been obtained by molecular replacement using Candida albicans MPI as the phasing model and the program Phaser. Further refinement and model building are in progress.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enabling human–infrastructure interfaces for inspection using augmented reality

Decaying infrastructure maintenance cost allocation depends heavily on accurate and safe inspection in the field. New tools to conduct inspections can assist in prioritizing investments in maintenance and repairs. The industrial revolution termed as “Industry 4.0” is based on the intelligence of machines working with humans in a collaborative workspace. Contrarily, infrastructure management has relied on the human for making day-to-day decisions. New emerging technologies can assist during infrastructure inspections, to quantify structural condition with more objective data. However, today’s owners agree in trusting the inspector’s decision in the field over data collected with sensors. If data collected in the field is accessible during the inspections, the inspector decisions can be improved with sensors. New research opportunities in the human–infrastructure interface would allow researchers to improve the human awareness of their surrounding environment during inspections. This article studies the role of Augmented Reality (AR) technology as a tool to increase human awareness of infrastructure in their inspection work. The domains of interest of this research include both infrastructure inspections (emphasis on the collection of data of structures to inform management decisions) and emergency management (focus on the data collection of the environment to inform human actions). This article describes the use of a head-mounted device to access real-time data and information during their field inspection. The authors leverage the use of low-cost smart sensors and QR code scanners integrated with Augmented Reality applications for augmented human interface with the physical environment. This article presents a novel interface architecture for developing Augmented Reality–enabled inspection to assist the inspector’s workflow in conducting infrastructure inspection works with two new applications and summarizes the results from various experiments. The main contributions of this work to computer-aided community are enabling inspectors to visualize data files from database and real-time data access using an Augmented Reality environment.

Maharjan, D.↗

Observations and Lessons Learned From Installing Residential Roofing-Integrated Photovoltaics

Building-sited solar photovoltaics (PV) could play a key role in decarbonizing the building sector either through racked and mounted PV or through Building-integrated PV (BIPV). BIPV is installed into the building envelope itself, with solar cells and/or modules forming the outer layer of a building structure, thus transforming a single-purpose structure into one that serves the dual purposes of the building envelope and electricity. BIPV can be applied to building roofs, facades, awnings, pergolas, windows, skylights, balustrades, and other external surfaces. Given BIPV products vary widely, the focus of this research is residential roofing integrated PV (RIPV), where solar is incorporated into or otherwise replaces the roofing material. Previous research suggests that residential RIPV could reduce customer acquisition, labor, supply chain, and equipment costs. These products have yet to realize these cost savings and deployment remains significantly less than conventional rooftop PV as a relative share of the addressable market in the US. One potential barrier to broader residential roofing integrated PV deployment may be higher costs relative to conventional rooftop PV, primarily because the design and installation of these products is still evolving. Here, we explore residential RIPV cost-reduction opportunities by analyzing installation processes. Our study documents residential RIPV installations at 2 reroofing sites and the equivalent of 9 new construction sites in California through a methodology known as time and motion study. We also conducted interviews with subject-matter experts to identify barriers and solutions to maximize these products' market penetration. Our time and motion study breaks the RIPV installation process into four steps: 1) staging, unloading, and roof preparation; 2) fire resistant underlayment(s) (synthetic material laid between roof shingles and roof deck); 3) flashings and PV installation; and 4) wiring and monitoring. We measure the time required for each step in terms of worker-hours, representing an hour of labor from a single worker. We further normalize process time by dividing worker-hours by kilowatt (kW) of system capacity. The most time-intensive step was flashings and PV installation, taking around 2.4 worker-hours per kW on average and accounting for around 60% of the process time for an average installation. The total installation process took on average about 6.4 and 3.5 worker-hours per kW at the reroofing sites and new construction sites, respectively. For comparison, a previous time and motion study documented a time of 6.9 worker-hours per kW for conventional rooftop PV. The shorter RIPV installation times are consistent with previous studies suggesting that RIPV could be installed faster than conventional rooftop PV. The time and motion results and feedback from interviewees provide insights into potential residential RIPV cost reduction opportunities. Several interviewees suggested that these products would be more efficient if PV installation was more fully integrated into the roofing/construction industries, which currently use separate supply chains and skillsets. Further integration could reduce supply chain delays and labor force redundancies. Future research could explore specific ways to integrate these industries to help realize the cost savings potential of RIPV.

14 SOLAR ENERGY↗

The radial distribution of H{sub 2} and CO in TW Hya as revealed by resolved ALMA observations of CO isotopologues

CO is widely used as a tracer of molecular gas. However, there is now mounting evidence that gas phase carbon is depleted in the disk around TW Hya. Previous efforts to quantify this depletion have been hampered by uncertainties regarding the radial thermal structure in the disk. Here we present resolved ALMA observations of {sup 13}CO 3-2, C{sup 18}O 3-2, {sup 13}CO 6-5, and C{sup 18}O 6-5 emission in TW Hya, which allow us to derive radial gas temperature and gas surface density profiles, as well as map the CO abundance as a function of radius. These observations provide a measurement of the surface CO snowline at ∼30 AU and show evidence for an outer ring of CO emission centered at 53 AU, a feature previously seen only in less abundant species. Further, the derived CO gas temperature profile constrains the freeze out temperature of CO in the warm molecular layer to <21 K. Combined with the previous detection of HD 1-0, these data constrain the surface density of the warm H{sub 2} gas in the inner ∼30 AU such that Σ{sub warmgas}=4.7{sub −2.9}{sup +3.0} g cm{sup −2}(R/10au){sup −1/2}. We find that CO is depleted by two orders of magnitude from R=10--60 AU, with the small amount of CO returning to the gas phase inside the surface CO snowline insufficient to explain the overall depletion. Finally, this new data is used in conjunction with previous modeling of the TW Hya disk to constrain the midplane CO snowline to 17–23 AU.

79 ASTRONOMY AND ASTROPHYSICS↗

A pulse width modulated picket fence pulser to reduce accelerator start-up transients

This paper describes a solid state modulator used to control the input beam to the Los Alamos Neutron Science Center 'LANSCE' 800 MeV accelerator. This electrostatic Ground Level Deflector (GLD) chops the beam after the 750 keV injection energy. Two GLD's are utilized, one for the 'H+' beam and another for the 'H-' beam. These modulators are mounted on the vacuum beam pipe and directly operate sets of deflection plates. To minimize the accelerator beam start up transients, the beam is let into the accelerator cavity structures by a pulse width modulated picket fence operating between 0 and 12 kV. As the deflection plate structure appears as a capacitive load, a totem-pole switching network is utilized to facilitate rise and fall times of {approx}50 ns that is able to sink and source current to minimize beam induced sidewall activation. This paper will describe the system design and provides operational results as now presently utilized on the LANSCE accelerator system.

43 PARTICLE ACCELERATORS↗

CTE-tuned pyrolytic graphite (PG) substrate to minimize joining stress between laser diode and the substrate

A pyrolytic graphite (PG) substrate and laser diode package includes a substrate body having a PG crystalline structure with a basal plane oriented at a pre-determined orientation angle as measured from a longitudinal axis of a heat generating material, such as a laser diode, mounted on a surface of the PG substrate, so that a coefficient of thermal expansion (CTE) of the PG substrate is substantially matched with a CTE of the material.

Patra, Susant K.↗

CTE-tuned pyrolytic graphite (PG) substrate to minimize joining stress between laser diode and the substrate

A pyrolytic graphite (PG) substrate and laser diode package includes a substrate body having a PG crystalline structure with a basal plane oriented at a pre-determined orientation angle as measured from a longitudinal axis of a heat generating material, such as a laser diode, mounted on a surface of the PG substrate, so that a coefficient of thermal expansion (CTE) of the PG substrate is substantially matched with a CTE of the material.

Patra, Susant↗

Simplified technique for remote monitoring of deflection in arch structures

This article describes a simplified technique to measure the vertical deflection of masonry arches in the presence of horizontal movements. One-dimensional laser Doppler vibrometer was utilized to measure the vertical displacement of the arch. A flat steel plate was mounted on the top surface of the arch crown to eliminate the measurement error due to the curvature of the arch. A reflective mirror was employed to guide the emitted laser beam normal to the surface of the steel plate. Vertical displacements recorded by laser Doppler vibrometer were compared to the readings of the mechanical dial gauge.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In crystallo optical spectroscopy (icOS) as a complementary tool on the macromolecular crystallography beamlines of the ESRF

The current version of the Cryobench in crystallo optical spectroscopy facility of the ESRF is presented. The diverse experiments that can be performed at the Cryobench are also reviewed. The analysis of structural data obtained by X-ray crystallography benefits from information obtained from complementary techniques, especially as applied to the crystals themselves. As a consequence, optical spectroscopies in structural biology have become instrumental in assessing the relevance and context of many crystallographic results. Since the year 2000, it has been possible to record such data adjacent to, or directly on, the Structural Biology Group beamlines of the ESRF. A core laboratory featuring various spectrometers, named the Cryobench, is now in its third version and houses portable devices that can be directly mounted on beamlines. This paper reports the current status of the Cryobench, which is now located on the MAD beamline ID29 and is thus called the ID29S-Cryobench (where S stands for ‘spectroscopy’). It also reviews the diverse experiments that can be performed at the Cryobench, highlighting the various scientific questions that can be addressed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Wind Turbine Controller to Mitigate Structural Loads on a Floating Wind Turbine Platform

This paper summarizes the control design work that was performed to optimize the controller of a wind turbine on the WindFloat structure. The WindFloat is a semi-submersible floating platform designed to be a support structure for a multi-megawatt power-generating wind turbine. A controller developed for a bottom-fixed wind turbine configuration was modified for use when the turbine is mounted on the WindFloat platform. This results in an efficient platform heel resonance mitigation scheme. In addition several control modules, designed with a coupled linear model, were added to the fixed-bottom baseline controller. The approach was tested in a fully coupled nonlinear aero-hydroelastic simulation tool in which wind and wave disturbances were modeled. This testing yielded significant improvements in platform global performance and tower-base-bending loading.

17 WIND ENERGY↗

Remote sensing images, DEM, and point clouds associated with “Accuracy evaluation of cost-effective 3D reconstruction approaches for hydrobiogeochemical processes in non-perennial stream riverbeds”

This data package is associated with the publication “Accuracy evaluation of cost-effective 3D reconstruction approaches for hydrobiogeochemical processes in non-perennial stream riverbeds” published in Frontiers in Environmental Science, Environmental Informatics and Remote Sensing (Bao et al., 2026; doi: 10.3389/fenvs.2026.1725258). This data package includes the drone photos for a section of Umtanum Creek in Washington, Unted States. The photos were used to reconstruct the 3-dimensional (3D) digital elevation model (DEM) of the riverbed for the investigated stream section. The reconstruction results from four approaches are provided: (1) unoccupied aerial vehicle (UAV, colloquially known as drone) imagery-based Structure-from-Motion (SfM), (2) a machine learning-based 3D reconstruction model, Visual Geometry Grounded Deep Structure from Motion (VGGSfM), (3) Visual Geometry Grounded Transformer for long sequence of images (VGGT-Long), and (4) handheld smartphone LiDAR scanning. The ground truth measurements by tripod-mounted optical level kit and ground control points GPS locations for evaluating the accuracy of the four reconstruction approaches are also provided in this data package. A preliminary version of this data package was published in October 2025 at the time of manuscript submission. It was updated in March 2026, at the time of manuscript acceptance, to include additional metadata (this readme, data dictionary, and file level metadata). The data did not change. For details on how to navigate data packages generated by this project, see https://data.ess-dive.lbl.gov/portals/PNNLRiverCorridorSFA/About. In addition to a readme, this data package also includes a file-level metadata (FLMD) file that describes each file and a data dictionary (DD) that describes all column/row headers and variable definitions. This dataset is comprised of (1) 8 folders; (2) the detailed flight configuration html files; (3) field metadata; (4) a readme; (5) a data dictionary; and (6) file-level metadata. The folders “2024_10_18_d01” and “2024_10_18_d02” contain the original drone photos for the two drone flights (d01 and d02) on October 18, 2024. The reconstruction results from each of the approaches are in the folders called “ODM_SfM”, “VGGSfM”, “VGGTLong”, and “LiDAR”. The ground truth measurements are in the folder called “optical_level_kit”. Lastly, results comparing the different approaches are in the folder called “comparisons”. All files are .csv, .html, .jpg, .obj, .txt, and .npy. For information on using the .obj and .npy files, see the readme files within the same folder as the files.

54 ENVIRONMENTAL SCIENCES↗

Portable positional scanning lane

A positional lane scanner and method therefor includes a positional lane cargo scanning structure having a first frame portion, a second frame portion, and a top frame portion connected to define a passage lane for a cargo vessel. The first and second frame portions are located on opposite sides and cargo vessels pass therebetween. The first and second frame portions, or both, include a first housing portion and a scanning device mounted within the first housing portion. A lifting member is provided on the top frame portion facing outward, or if the lifting means is on a transport vehicle, such as a reach spreader, a pair of lifting beams may be arranged on the transport vehicle. The lift member removably connects with a boom portion of the transport vehicle for positioning and relocating the scanning structure to be disposed adjacent a cargo vessel lane.

Stihel, Gregory C.↗

Underground azelaic acid-conferred resistance to Pseudomonas syringae in Arabidopsis

Local interactions between individual plant organs and diverse microorganisms can lead to whole plant immunity via the mobilization of defense signals. One such signal is the plastid lipid-derived oxylipin azelaic acid (AZA). Arabidopsis lacking AZI1 or EARLI1, related lipid transfer family proteins, exhibit reduced AZA transport among leaves and cannot mount systemic immunity. AZA has been detected in roots as well as leaves. Thus, the present study addresses the effects on plants of AZA application to roots. AZA, but not the structurally related suberic acid, inhibits root growth when directly in contact with roots. Treatment of roots with AZA also induces resistance to Pseudomonas syringae in aerial tissues. Additionally, these effects of AZA on root growth and disease resistance depend at least partially on AZI1 and EARLI1. AZI1 in roots localizes to plastids, similar to its known location in leaves. Interestingly, kinases previously shown to modify AZI1 in vitro, MPK3/6, are also needed for AZA-induced root growth inhibition and above ground immunity. Finally, [2H]-AZA applied to the roots does not move to aerial tissues. Therefore, AZA application to roots triggers systemic immunity through an AZI1/EARLI1/MPK3/MPK6-dependent pathway and AZA’s effects may involve an additional mobile signal(s).

59 BASIC BIOLOGICAL SCIENCES↗

Soil Water Retention and Hydraulic Conductivity Data and Model at Pump House in East River Watershed, Colorado 2019-2024

This data package includes soil water retention and hydraulic conductivity data and model fitting results from measurements of ex-situ soil samples and in-situ soil sensors near Pump House at Mount Crested Butte in the East River Watershed. Soil water retention curves (SWRC) characterize soil water content as a function of soil water potential. SWRC depends on soil texture and pore structure and can be used to describe the constraints on biogeochemical processes in terms of soil water availability. In this data package, the sample identification follows the format ER-X-Y, where ER refers to East River, X is the location identifier, and Y is the depth identifier at the same X (shallow Y=1). Specifically, ER-PHS, ER-LMC, ER-LMF, and ER-SMN are associated with ecohydrology sites under the East-Taylor Watershed Community Observatory Sites directory, and ER-RBTn (upslope n=1) are sampling transects during the 2019 Rootball Campaign. The sample and location information can be found in metadata.csv. Sampling and Measurements Each sample falls into one of the three sampling methods – (1) intact cores, (2) repacked samples, or (3) soil sensors – and one of the two measurement methods – (a) laboratory or (b) in-situ. Both intact cores and repacked samples were measured using the laboratory methods, which include measurements of soil water potential (HYPROP & WP4C, METER), saturated (KSAT, METER) and unsaturated hydraulic conductivity (HYPROP). The in-situ method uses a pair of co-located soil sensors to measure volumetric water content (TEROS12, METER) and soil water potential (TEROS21, METER), and the hydraulic conductivity was not measured. In comparison, the laboratory methods progress from full saturation to dry conditions, and the in-situ method includes both dry-to-wet and wet-to-dry cycles. The sampling and measurement methods for each sample can be found in metadata.csv, and more information about the measurements is detailed in the Methods section below. Models Retention and hydraulic conductivity data were fitted with four van-Genuchten-type models (specified by “model_name” column in the files): (1) traditional constrained van Genuchten model (“vG_constrained”), (2) traditional unconstrained van Genuchten model (“vG_unconstrained”), (3) PDI-variant of the constrained van Genuchten model (“vG_constrained_PDI”), and (4) PDI-variant of the unconstrained van Genuchten model (“vG_unconstrained_PDI”). The difference between the constrained (1: n) and the unconstrained (2: n, m) van Genuchten models is the number of pore-size distribution parameters in the model equations, giving the unconstrained model more degrees of freedom when fitting the data. Between the traditional and the PDI-variant models, model fitting differs the most at the dry end of the measurements. The traditional models allow infinite suction at the residual water content (water content does not drop below residual water content), and the PDI-variant models enforce a soil water potential value of pF=6.8 (~ -630 MPa) at oven-dryness (water content reaches 0). The inclusion of the van-Genuchten-type models is due to their common application. If other retention models are required, users can access the data in data.csv for further data fitting. More information about the models can be found in the Methods section below. Fitting Tasks The model fitting can be categorized into three levels of tasks (specified by “fitting_task” column in the files). Level 1 (“fit_retention”) only includes retention data fitting (the only level available for the in-situ method). Level 2 (“fit_retention_conductivity”) includes both retention and hydraulic conductivity data fitting, and the saturated hydraulic conductivity (Ks, a parameter of the hydraulic conductivity functions) is fixed by the measurements from KSAT. Level 3 (“fit_retention_conductivity_Ks”) also includes both retention and hydraulic conductivity data fitting, but Ks is a fitted parameter without the constraints from KSAT measurements. Among the same retention models (e.g. vG_constrained models of the same sample), level 1 should produce the best retention data fitting. Level 2 should have the highest misfit of the retention and hydraulic conductivity data, because the retention and hydraulic conductivity functions share common model parameters, and the unsaturated hydraulic conductivity (HYPROP) data fitting is subject to Ks measured independently by KSAT. Level 3 should have mid-level misfits of the retention and hydraulic conductivity data. While level 3 fits the hydraulic conductivity data better than level 2, the fitted Ks value might be unreasonable due to the lack of constraints at the wet end of the measurements. General recommendation when using this data package: (1) Choice of sampling methods: Intact cores and in-situ soil sensors could be prioritized because these sampling methods are less destructive. While the repacked samples were packed to the target bulk density (estimated post-sampling, when sample volume was known), these samples had altered pore structures. Nevertheless, intact cores might suffer from sample gaps that would lead to overestimation of Ks (sample gaps can be inferred from the “soil_sample_volume” column in metadata.csv when the value is < 249). In-situ method also has higher uncertainty in characterizing the wet end of the SWRC because of sensor limitations and the difficulty in reaching full saturation under natural conditions. (2) Choice of fitting tasks: When only retention data is needed, level 1 (“fit_retention”) should be prioritized. When both retention and hydraulic conductivity data are needed, level 2 (“fit_retention_conductivity”) could be prioritized. (3) Choice of models: This could depend on what the downstream models call for. If no specific model is required, model misfit could be used as a ranking criterion. Model misfit values in terms of RMSE can be found in model_parameters.csv. The following files are included in this data package: (1) metadata.csv – This file includes the general information of each sample, including location (description, geocoordinates, elevation), sampling and measurements details (method, depth, time or period, volume, instruments), and soil physical properties (bulk density, saturated hydraulic conductivity, only applicable to physical soil samples). (2) data.csv – This file includes soil water potential, volumetric water content, and unsaturated hydraulic conductivity data of each sample. Column “instrument” specifies the instrument (HYPROP, WP4C, or TEROS) used to perform the measurements. (3) model_fit.csv – This file includes soil water potential, volumetric water content, and unsaturated hydraulic conductivity fitted from the four models and three fitting tasks. Column “model_name” specifies the retention model used, and “fitting_task” specifies the level of data fitting. Missing values indicate that the variable does not apply to that fitting task. (4) model_parameters.csv – This file includes the fitted model parameters, model misfits, and conventional water content thresholds (field capacity and wilting point) from the four models and three fitting tasks. Column “model_name” specifies the retention model used, and “fitting_task” specifies the level of data fitting. Missing values indicate that the parameter does not apply to that model and/or that fitting task. (5) data_Ks.csv – This file includes the saturated hydraulic conductivity measurements from KSAT. (6) /figure/*.png – This folder includes three quick visualizations of the data, retention model fitting results and misfits, and hydraulic conductivity model fitting results, misfits, and parameters. The model fitting results are separated by samples and fitting tasks and colored by models. Zoom-in required. (7) /hyprop/*.bdhx – This folder includes proprietary hyprop files that require the free Labros SoilView-Analysis (METER) to open. Users can explore data fitting using other retention models (i.e. Brooks-Corey, Fredlund-Xing, Kosugi, bimodal models). Be aware that Ks value is pre-entered under “Fitting tab, Conductivity functions parameters” for level 2 fitting. If the value is lost, please refer to metadata.csv under “Ks” column. (8) Six file-level metadata that summarize file, header, column, and variable information of all files. This work was supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231.

EARTH SCIENCE > LAND SURFACE > SOILS↗

Study of correlation effects in nuclei at the limit of stability. Final report

Exotic nuclei far from the valley of stability are a particularly exciting testing ground to probe nucleon-nucleon correlations in a regime where the numbers of constituent protons and neutrons are out of balance and the influence of isospin-dependent terms within the nuclear force becomes amplified. The grant DE-FG02-08ER41556 has supported from 2008 to 2019 an MSU graduate student research assistantship at the heart of a research program that explored the evolution of nuclear structure in exotic nuclei with gamma-ray spectroscopy experiments in the N=40 region of neutron-rich nuclei at NSCL and at ATLAS at Argonne National Laboratory and that mounted a new low-energy Coulomb excitation program at NSCL’s ReA accelerator within the PI’s research program. This final scientific/technical report describes the results and outcomes resulting from the support by the Department of Energy, Office of Science, Office of Nuclear Physics.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design of the FRIB Cryomodule

An advanced, modular bottom-supported cryomodule design is described which is highly optimized for mass-production and efficient precision-assembly. The FRIB driver linac uses 4 types of superconducting resonators and 2 solenoid lengths which in turn require 7 individual cryomodule configurations. To meet alignment tolerances a precision-machined bolted cryomodule rail system is described. A novel, kinematic mounting system of the cold mass is introduced which allows for thermal contractions while preserving alignment. A first prototype will incorporate a wire position monitor for alignment verification. The cold alignment structure is supported by composite posts which also function as thermal isolators. The cryogenic system provides separate 2 K and 4.5 K liquid helium lines to cavities and solenoids. Details of the JT valves, heat exchanger, cool-down circuit and junction to cryogenic line will be provided. Transient cool-down was simulated for stresses and buckling failure. A 1100-O Aluminum shield is used as a thermal radiation shield. The paper also describes cryomodule interfaces with the linac tunnel, the RF input cables, and the cryogenic distribution system.

43 PARTICLE ACCELERATORS↗

A Novel Mobile Examination and Remediation Facility for On-Site Remediation of Dry Storage Systems - 18389

Most of the spent nuclear fuel (SNF) in dry storage in the United States is safely and securely stored in dual-purpose (i.e., storage and transportation) canisters [1]. However, some of the SNF is stored in storage-only (i.e., non-transportable) packages, or packages that may become nonconforming for continued storage or transportation for a variety of reasons. Currently, the capability to remediate dry storage systems (DSSs) for SNF that are not transportable or that need to be repaired to maintain confinement boundary integrity during storage service does not exist without on-site access to a spent fuel pool. Hence, there is a potential future need for a mobile facility with remediation capabilities that can be used at multiple storage installations. These capabilities would permit needed repairs to an existing DSS to support continued storage or for the dry transfer of fuel to a new conveyance suitable for transport, if necessary. This is a technical paper that does not take into account the contractual limitations under the Standard Contract for Disposal of Spent Nuclear Fuel and/or High-Level Radioactive Waste (Standard Contract) (10 CFR Part 961). Under the provisions of the Standard Contract, DOE does not consider spent nuclear fuel in canisters to be an acceptable waste form, absent a mutually agreed to contract amendment. To the extent discussions or recommendations in this paper conflict with the provisions of the Standard Contract, the Standard Contract provisions prevail. A novel design concept for a Mobile Examination and Remediation Facility (MERF) is proposed with functions and capabilities to remediate a DSS. The proposed MERF would be a multi-purpose facility, remotely operated and computer-controlled with semi-automated equipment to allow trained operators to safely perform remediation activities while keeping worker radiation dose as low as reasonably achievable. It would include a shielded rotating platform with support towers and would use commercial off- the-shelf examination and repair equipment. A slip ring arrangement underneath the rotating platform would allow for the power supply without impeding the continuous rotation and would simplify cable management. The support towers would be mounted on the rotating platform, and each tower would have vertical and horizontal positioning capability for axial and radial tool location. The rotating platform would be attached to the main MERF structure. Capabilities would include visual, surface, and volumetric examinations to fully characterize physical conditions on canister surface before and after a repair; repair techniques, e.g., laser beam welding, friction stir welding, or cold spray, to perform needed remediation activities; and associated equipment for surface preparation such as cutting and grinding equipment. The proposed design would be simple, modular, robust, economically viable, and easily transportable and would have a small footprint. The modular design would present several advantages including compatibility with a variety of different DSSs, on-site assembly, and transportability; it also would be built in interchangeable sections to facilitate decontamination. Further, shielding would be supplemented through interface with the existing transfer cask and storage overpack. Robustness and canister stability would be achieved using pneumatic holders and steel support structures designed with vibration absorbers to reduce impacts and/or a 'pendulum' effect during a seismic event. Thus, the proposed MERF would be designed to: (i) minimize handling of an affected DSS to the extent practicable, (ii) provide radiation shielding and minimize dose to operators and the public during remediation activities, and (iii) enable examination, repair, and repackaging. This paper describes the proposed MERF design concept and capabilities, main components, equipment, different modes of operation, and operating procedures. Structural and safety assessments would need to be performed before final design, licensing, and deployment. The MERF is evaluated with respect to regulatory impact (first of a kind, prior experience), operational impact (safety, security, staffing, ongoing operations, constraints), worker dose (low, medium, high), cost (low, medium, high), schedule (duration, time sequence), and technology readiness level. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Combined Structural Analysis of Core and Image Log of TGH 76-31 South East of Mt Baker, Washington State

Despite active volcanism, few geothermal energy resources have been developed in the Cascades Range. Temperature Gradient Hole 76-31 was drilled to ~440 m measured depth to probe for zones where fractures provide fluid conduits that transport deep volcanic heat to shallow depths that could support baseload, carbon neutral electrical generation. These zones were predicted by a Play Fairway assessment (PFA) of resource potential along a zone 11 km west-southwest of the summit of Mount Baker Volcano. Rock core, temperature logs, and an acoustic image log were obtained. By comparison to outcrops, the core has been initially interpreted as the Chilliwack group comprised of partially metamorphosed basaltic to andesitic volcanics. Core mapping reveals complex, steeply dipping networks of fractures and brecciation along slickensided strike slip faults; clay alteration is common in many of these structures. The majority of fractures are thoroughly healed by layers of chlorite and calcite; preservation of pyrite indicates anoxic conditions. The majority of fracture porosity resides in very dense fractures a few centimeters or less in length. The image log provides good insights into attitude of fractures that fully transect the core, but generally underestimates fracture density. The combination of complex, non-planar fracture zones containing many short fractures and healing promote misinterpretation of natural fracture attitude and density in the image log. The healing and anoxic minerals are consistent with the conductive temperature gradient measured in the well below a shallow isothermal zone, although, several fractures are open or only partially healed and resulted in fluid entries into the well. Here, the equilibrated measured temperature gradient of 64ºC/km and calculated heat flow of 145 mW/m2 is more than twice the regional average, indicating local influence of the Mt Baker magmatic system at the Little Park Creek TGH site.

Cascades↗