Search NASA⌕ Search

SEARCH · Search NASA

Results for “study protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

No Clinically Significant Changes in Pulmonary Function Following Stereotactic Body Radiation Therapy for Early- Stage Peripheral Non-Small Cell Lung Cancer: An Analysis of RTOG 0236

Purpose: To investigate pulmonary function test (PFT) results and arterial blood gas changes (complete PFT) following stereotactic body radiation therapy (SBRT) and to see whether baseline PFT correlates with lung toxicity and overall survival in medically inoperable patients receiving SBRT for early stage, peripheral, non-small cell lung cancer (NSCLC). Methods and Materials: During the 2-year follow-up, PFT data were collected for patients with T1-T2N0M0 peripheral NSCLC who received effectively 18 Gy × 3 in a phase 2 North American multicenter study (Radiation Therapy Oncology Group [RTOG] protocol 0236). Pulmonary toxicity was graded by using the RTOG SBRT pulmonary toxicity scale. Paired Wilcoxon signed rank test, logistic regression model, and Kaplan-Meier method were used for statistical analysis. Results: At 2 years, mean percentage predicted forced expiratory volume in the first second and diffusing capacity for carbon monoxide declines were 5.8% and 6.3%, respectively, with minimal changes in arterial blood gases and no significant decline in oxygen saturation. Baseline PFT was not predictive of any pulmonary toxicity following SBRT. Whole-lung V5 (the percentage of normal lung tissue receiving 5 Gy), V10, V20, and mean dose to the whole lung were almost identical between patients who developed pneumonitis and patients who were pneumonitis-free. Poor baseline PFT did not predict decreased overall survival. Patients with poor baseline PFT as the reason for medical inoperability had higher median and overall survival rates than patients with normal baseline PFT values but with cardiac morbidity. Conclusions: Poor baseline PFT did not appear to predict pulmonary toxicity or decreased overall survival after SBRT in this medically inoperable population. Poor baseline PFT alone should not be used to exclude patients with early stage lung cancer from treatment with SBRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hematologic Toxicity in Patients Treated With Postprostatectomy Whole-Pelvis Irradiation With Different Intensity Modulated Radiation Therapy Techniques Is Not Negligible and Is Prolonged: Preliminary Results of a Longitudinal, Observational Study

Purpose: To address the thus-far poorly investigated severity and duration of hematologic toxicity from whole-pelvis radiation therapy (WPRT) in a cohort of chemo-naïve patients treated with postprostatectomy radiation therapy including WPRT with different intensity modulated radiation therapy (IMRT) techniques, doses, and fractionations. Methods and Materials: This analysis pertains to 125 patients (70 from a pilot study and 55 from an observational protocol) for whom 1 baseline and at least 3 subsequent blood samples (median 6), obtained at irradiation midpoint and end, and thereafter at 3, 6, and 12 months, were available. Patients were treated with adjuvant (n=73) or salvage intent; static-field IMRT (n=19); volumetric modulated arc therapy (n=60) or helical Tomotherapy (n=46); and conventional (n=39) or moderately hypofractionated (median 2.35 Gy per fraction, n=86) regimens. The median 2-Gy equivalent dose (EQD2) to the prostatic bed was 70.4 Gy with a lymph-nodal planning target volume of 50.2 Gy. Clinical and dosimetric data were collected. Results: Both leukopenia and thrombocytopenia were significant (median nadir count 65% and 67% of baseline, respectively), with leukopenia also persisting (1-year median count 75% of baseline). Lymphopenia was the major contributor to the severity and 1-year persistence of leukopenia; all patients developed acute grade ≥1 lymphopenia (61% and 26% grade 2 and ≥3, respectively), whereas 1-year grade ≥2 lymphopenia was still present in 16%. In addition to an independent predictive role of corresponding baseline values, multivariable analyses highlighted that higher EQD2 doses to lymph nodal planning target volume increased risk of acute neutropenia and hypofractionation for acute thrombocytopenia. Of note, patients of older age were at higher risk for acute grade 2 lymphopenia, and interestingly, increased risk of grade >2 lymphopenia for those who smoked at least one year. No role for different IMRT techniques indicated. Conclusions: Leukopenia and lymphopenia after postprostatectomy WPRT were found to be less negligible and more prolonged than expected. A number of radiation-related and clinical factors favoring hematologic toxicity, whose awareness may be crucial when prescribing WPRT, in particular if concomitant to chemotherapy, were identified.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Machine learning prediction on the fractional free volume of polymer membranes

Fractional free volume (FFV) characterizes the microstructural level features of polymers and affects their properties including thermal, mechanical, and separation performance. Experimental measurements and theoretical analyses have been used to quantify the FFV of polymers, but challenges remain because of their limitations. Experimental measurements are laborious and based on semi empirical equations, while Bondi’s group contribution theory involves ambiguities like the determination of van der Waals volume and the choice of factor values in the theoretical equation. To efficiently evaluate the FFV of polymers, this study utilizes high-throughput molecular dynamics (MD) simulations to build a large dataset regarding polymer’s FFV. Based on this large dataset, we further build machine learning (ML) models to establish the composition-structure relation. Inspired by group contribution theory which correlates polymer’s functional groups to FFV, our ML models correlate polymer’s substructures or physico-chemical indexes to FFV. Here, our study first benchmarks the MD simulation protocol to obtain reliable FFV of polymers and then carries out high-throughput MD simulations for more than 6,500 homopolymers and 1,400 polyamides. Such a large and diverse dataset makes the well-trained ML models more generalizable, compared with the group contribution theory. The efficiency of a feed forward neural network model is further demonstrated by applying it to a hypothetical polyimide dataset of more than 8 million chemical structures. The predicted FFVs of hypothetical polyimides are further validated by MD simulations. The obtained FFVs of the 8 million polymers, plus their previously reported gas separation performances, demonstrate the promising capability of ML virtual screening for the discovery of polymer membranes with exceptional permeability/selectivity.

36 MATERIALS SCIENCE↗

Parallel evaluation of alternative skin barrier models and excised human skin for dermal absorption studies in vitro

Skin permeation is a primary consideration in the safety assessment of cosmetic ingredients, topical drugs, and human users handling veterinary medicinal products. While excised human skin (EHS) remains the ‘gold standard’ for in vitro permeation testing (IVPT) studies, unreliable supply and high cost motivate the search for alternative skin barrier models. In this study, a standardized dermal absorption testing protocol was developed to evaluate the suitability of alternative skin barrier models to predict skin absorption in humans. Under this protocol, side-by-side assessments of a commercially available reconstructed human epidermis (RhE) model (EpiDerm-200-X, MatTek), a synthetic barrier membrane (Strat-M, Sigma-Aldrich), and EHS were performed. The skin barrier models were mounted on Franz diffusion cells and the permeation of caffeine, salicylic acid, and testosterone was quantified. Transepidermal water loss (TEWL) and histology of the biological models were also compared. EpiDerm-200-X exhibited native human epidermis-like morphology, including a characteristic stratum corneum, but had an elevated TEWL as compared to EHS. The mean 6 h cumulative permeation of a finite dose (6 nmol/cm2) of caffeine and testosterone was highest in EpiDerm-200-X, followed by EHS and Strat-M. Salicylic acid permeated most in EHS, followed by EpiDerm-200-X and Strat-M. Altogether, evaluating novel alternative skin barrier models in the manner outlined herein has the potential to reduce the time from basic science discovery to regulatory impact.

60 APPLIED LIFE SCIENCES↗

Testing Pollen Sorted by Flow Cytometry as the Basis for High-Resolution Lacustrine Chronologies

Documenting leads and lags in terrestrial records of past climate change is critical to understanding the behavior of Earth’s natural climate system and making reliable predictions of future climate conditions. However, uncertainties of several hundred years in age models make it difficult to distinguish synchronicity and feedbacks in paleo archives. In lakes this is often due to the lack of terrestrial macrofossils in climate-sensitive locations, such as high alpine or dryland settings. The potential of radiocarbon (14C) dating of pollen has long been recognized, but the difficulty of cleanly separating pollen from other kinds of organic carbon has limited its usefulness. Here we report 14C ages on pollen separated by flow cytometry, from a set of closely spaced samples from Mono Lake, California. The accuracy of the pollen ages is tested using well-dated bracketing tephras, the South Mono and North Mono-Inyo tephras. In spite of the purity of the sorted samples, the pollen dates are older than the bounding tephras by ~400 yr, similar to some other pollen-dating studies. While improvements in sample preparation protocols are planned, understanding the geological processes involved in the production, preservation, and deposition of pollen at each site will be critical to developing robust high-resolution age models.

58 GEOSCIENCES↗

Structure of Novel Phosphonium-Based Ionic Liquids with S and O Substitutions from Experiments and a Mixed Quantum-Classical Approach

This article presents experimental characterization information and synchrotron X-ray scattering measurements on a set of novel O- and S-substituted phosphonium-based ionic liquids (ILs) all coupled with the bis(fluorosulfonyl)imide (FSI-) anion. The ILs include the ethoxyethyltriethylphosphonium (P 222(2O2) + ) and triethyl[2-(ethylthio)ethyl]phosphonium (P 222(2S2) + ) cations, and we contrast results on these with those for unsubstituted triethylpentylphosphonium (P 2225 + ). The article also introduces a physics-based protocol that combines classical force field studies on larger simulation boxes with classical and first-principles studies on smaller boxes. The method produces significantly improved S(q) functions in the regime which in prior publications we have associated with inter- and intraionic adjacency correlations. By understanding which shorter-range structural changes improve S(q) in the q-regime of interest, we are also able to pinpoint specific deficiencies in the classical force field model. The approach we take should be quite general and could help study other complex liquids on different length scales.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigating Fundamental Principles of Nonequilibrium Assembly Using Temperature-Sensitive Copolymers

Both natural biomaterials and synthetic materials benefit from complex energy landscapes that provide the foundation for structure–function relationships and environmental sensitivity. Understanding these nonequilibrium dynamics is important for the development of design principles to harness this behavior. Using a model system of poly(ethylene glycol) methacrylate-based thermoresponsive lower critical solution temperature (LCST) copolymers, we explored the impact of composition and stimulus path on nonequilibrium thermal hysteretic behavior. Through turbidimetry analysis of nonsuperimposable heat–cool cycles, we observe that LCST copolymers show clear hysteresis that varies as a function of pendent side chain length and hydrophobicity. Hysteresis is further impacted by the temperature ramp rate, as insoluble states can be kinetically trapped under optimized temperature protocols. As a result, this systematic study brings to light fundamental principles that can enable the harnessing of out-of-equilibrium effects in synthetic soft materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Controlled Synthesis of SnO 2 Nanocrystals with Tunable Band Gaps

Tin(IV) oxide nanocrystals (SnO 2 NCs) have significant potential in various applications, with their performance closely related to their band gap. The band gap is influenced by the size and shape of the NCs, which can be precisely controlled by adjusting reaction conditions. In this study, we present deliberately designed synthesis protocols to produce high-quality SnO 2 NCs with tunable band gaps using different methods. Key factors affecting the synthesis include control of the oxidizing agent, reaction temperature, solvent selection, and reaction time optimization. The resulting NCs were characterized by using TEM, XRD, XPS, and optical spectroscopy. Notably, SnO 2 NCs synthesized by controlling the oxidizing agent (air injection) in a hot organic solution were smaller in size and exhibited abundant oxygen vacancies. In contrast, extending the reaction time or using ethanol as a solvent in hydrothermal systems facilitated larger spherical or rod-like SnO 2 NCs with fewer oxygen vacancies. Further analysis of the band gap and valence band maximum energy revealed that the abundant vacancies in SnO 2 NCs synthesized with the air-controlled hot organic solution method resulted in a narrower band gap and an upshifted valence band. These synthetic strategies illustrate the potential for deliberately designing SnO 2 NCs with optimized electronic structures for various applications.

band gap↗

Scalable graphene sensor array for real-time toxins monitoring in flowing water

Abstract Risk management for drinking water often requires continuous monitoring of various toxins in flowing water. While they can be readily integrated with existing water infrastructure, two-dimensional (2D) electronic sensors often suffer from device-to-device variations due to the lack of an effective strategy for identifying faulty devices from preselected uniform devices based on electronic properties alone, resulting in sensor inaccuracy and thus slowing down their real-world applications. Here, we report the combination of wet transfer, impedance and noise measurements, and machine learning to facilitate the scalable nanofabrication of graphene-based field-effect transistor (GFET) sensor arrays and the efficient identification of faulty devices. Our sensors were able to perform real-time detection of heavy-metal ions (lead and mercury) and E. coli bacteria simultaneously in flowing tap water. This study offers a reliable quality control protocol to increase the potential of electronic sensors for monitoring pollutants in flowing water.

47 OTHER INSTRUMENTATION↗

Loss-tolerant quantum secure positioning with weak laser sources

Quantum position verification (QPV) is the art of verifying the geographical location of an untrusted party. It has recently been shown that the widely studied Bennett & Brassard 1984 (BB84) QPV protocol is insecure after the 3 dB loss point assuming local operations and classical communication (LOCC) adversaries. Here in this paper, we propose a time-reversed entanglement swapping QPV protocol (based on measurement-device-independent quantum cryptography) that is highly robust against quantum channel loss. First, assuming ideal qubit sources, we show that the protocol is secure against LOCC adversaries for any quantum channel loss, thereby overcoming the 3 dB loss limit. Then, we analyze the security of the protocol in a more practical setting involving weak laser sources and linear optics. Lastly, in this setting, we find that the security only degrades by an additive constant and the protocol is able to verify positions up to 47 dB channel loss.

47 OTHER INSTRUMENTATION↗

SU-E-J-229: Magnetic Resonance Imaging of Small Fiducial Markers for Proton Beam Therapy

Purpose: For proton beam therapy, small fiducial markers are preferred for patient alignment due to less interference with the proton beam. Visualizing small fiducial markers can be challenging in MRI. This study intends to investigate MRI imaging protocols for better visualization of small fiducial markers. Methods: Two carbon and two coil-shaped gold markers were placed into a gel phantom. Both carbon markers had a diameter of 1mm and a length of 3mm. Both gold markers had a length of 5mm. One gold marker had a diameter of 0.5mm and the other had a diameter of 0.75mm. T1 VIBE, T2 SPACE, TrueFISP and susceptibility weighted (SW) images were acquired. To improve marker contrast, high spatial resolution was used to reduce partial volume effect. Slice thickness was 1.5mm for all four sequences and in-plane resolution was 0.6mm for TrueFISP, 0.7mm for T1 VIBE, and 0.8mm for T2 SPACE and SW. For comparison purpose, a 3D T1 VIBE image set at 3mm slice thickness and 1.2mm in-plane resolution was also acquired. Results: All markers were visible in all high-resolution image sets. In each image set, marker-induced signal void was the smallest (in diameter) for carbon markers, followed by the 0.5mm gold marker and the largest for the 0.75mm gold marker. The SW images had the largest marker-induced signal void. However, those might be confused by susceptibility-gradient-induced signal voids. T1 VIBE had good visualization of markers with nicely defined edges. T2 SPACE had reasonable visualization of markers but edges were slightly blurred. TrueFISP had good visualization of markers only if they were not masked by banding artifacts. As a comparison, all markers were hardly visible in the standard resolution T1 VIBE images. Conclusion: 3D high-resolution T1 VIBE and SW have great potential in providing good visualization of small fiducial markers for proton beam therapy.

60 APPLIED LIFE SCIENCES↗

Technical Note: Phantom study to evaluate the dose and image quality effects of a computed tomography organ-based tube current modulation technique

Purpose: This technical note quantifies the dose and image quality performance of a clinically available organ-dose-based tube current modulation (ODM) technique, using experimental and simulation phantom studies. The investigated ODM implementation reduces the tube current for the anterior source positions, without increasing current for posterior positions, although such an approach was also evaluated for comparison. Methods: Axial CT scans at 120 kV were performed on head and chest phantoms on an ODM-equipped scanner (Optima CT660, GE Healthcare, Chalfont St. Giles, England). Dosimeters quantified dose to breast, lung, heart, spine, eye lens, and brain regions for ODM and 3D-modulation (SmartmA) settings. Monte Carlo simulations, validated with experimental data, were performed on 28 voxelized head phantoms and 10 chest phantoms to quantify organ dose and noise standard deviation. The dose and noise effects of increasing the posterior tube current were also investigated. Results: ODM reduced the dose for all experimental dosimeters with respect to SmartmA, with average dose reductions across dosimeters of 31% (breast), 21% (lung), 24% (heart), 6% (spine), 19% (eye lens), and 11% (brain), with similar results for the simulation validation study. In the phantom library study, the average dose reduction across all phantoms was 34% (breast), 20% (lung), 8% (spine), 20% (eye lens), and 8% (brain). ODM increased the noise standard deviation in reconstructed images by 6%–20%, with generally greater noise increases in anterior regions. Increasing the posterior tube current provided similar dose reduction as ODM for breast and eye lens, increased dose to the spine, with noise effects ranging from 2% noise reduction to 16% noise increase. At noise equal to SmartmA, ODM increased the estimated effective dose by 4% and 8% for chest and head scans, respectively. Increasing the posterior tube current further increased the effective dose by 15% (chest) and 18% (head) relative to SmartmA. Conclusions: ODM reduced dose in all experimental and simulation studies over a range of phantoms, while increasing noise. The results suggest a net dose/noise benefit for breast and eye lens for all studied phantoms, negligible lung dose effects for two phantoms, increased lung dose and/or noise for eight phantoms, and increased dose and/or noise for brain and spine for all studied phantoms compared to the reference protocol.

60 APPLIED LIFE SCIENCES↗

Benefits of Fast Battery Formation in a Model System

Lithium-ion battery formation affects battery cost, energy density, and lifetime. An improved understanding of the first cycle of solid-electrolyte interphase (SEI) growth on carbonaceous negative electrodes could aid in the design of optimized formation protocols. In this work, we systematically study SEI growth during the formation of carbon black negative electrodes in a standard carbonate electrolyte. We show that the initial ethylene carbonate (EC) reduction reaction occurs at ~0.5-1.2 V during the first lithiation, except under fast lithiation rates (≥10C). The products of this EC reduction reaction do not passivate the electrode; only the SEI formed at lower potentials affects the second-cycle Coulombic efficiency. Thus, cycling quickly through the voltage regime of this reaction can decrease both formation time and first-cycle capacity loss, without an increase in subsequent-cycle capacity loss. We also show that the capacity consumed by this reaction is minimized at low temperatures and low salt concentrations. Finally, we discuss the mechanism behind our experimental results. This work reveals the fundamental processes underlying initial SEI growth on carbonaceous negative electrodes and provides insights for both optimizing the battery formation process and enabling novel electrolytes.

25 ENERGY STORAGE↗

Catalyst Deactivation Modes of PdO/γ-Al 2 O 3 Catalysts for Lean Methane Oxidation

PdO/γ-Al 2 O 3 catalysts are one of the most active catalytic components for the complete oxidation of methane. Under reaction conditions, especially in a wet feed, the catalysts suffer severe performance degradation. This study establishes a series of testing protocols to systematically investigate the causes of catalyst deactivation under methane oxidation reaction conditions. Four distinct catalyst deactivation modes are identified. Two of the deactivation modes are directly related to H 2 O, either from the feed gas or as a part of the reaction products, with one (Mode 2) being attributed to the formation of surface hydroxyl groups and the other (Mode 3) to the competitive adsorption of H 2 O on the catalysts. The impact of the two deactivation modes is acute and severe but reversible. In contrast, the other two deactivation modes are gradual and persistent but irreversible. Both modes are induced by CH 4 oxidation reaction, with the impact of a wet feed (Mode 4) being substantially more severe than that of a dry feed (Mode 1). The major cause of the irreversible catalyst deactivation is attributed to surface reconstruction of PdO nanoparticles, which behaves as a passivation layer lowering the number of coordinately unsaturated Pd sites for CH 4 activation. Although the passivation layer is relatively stable against thermal or hydrothermal treatment, it is not completely inert. Formation and partial regeneration of the passivation layer is a highly dynamic process and heavily depends on the reaction temperature: a lower reaction temperature (≤ 450 ℃) can lead to quicker catalyst deactivation; but a higher reaction temperature (between 500 – 550 ℃) can result in a greater extent of catalyst deactivation.

PdO/γ-Al2O3↗

Pilot Residential Deep Energy Retrofits and the PNNL Lab Homes

This report summarizes research investigating the technical and economic feasibility of several pilot deep energy retrofits, or retrofits that save 30% to 50% or more on a whole-house basis while increasing comfort, durability, combustion safety, and indoor air quality. The work is being conducted for the U.S. Department of Energy Building Technologies Program as part of the Building America Program. As part of the overall program, Pacific Northwest National Laboratory (PNNL) researchers are collecting and analyzing a comprehensive dataset that describes pre- and post-retrofit energy consumption, retrofit measure cost, health and comfort impacts, and other pertinent information for each home participating in the study. The research and data collection protocol includes recruitment of candidate residences, a thorough test-in audit, home energy modeling, and generation of retrofit measure recommendations, implementation of the measures, test-out, and continued evaluation. On some homes, more detailed data will be collected to disaggregate energy-consumption information. This multi-year effort began in October 2010. To date, the PNNL team has performed test-in audits on 51 homes in the marine, cold, and hot-humid climate zones, and completed 3 retrofits in Texas, 10 in Florida, and 2 in the Pacific Northwest. Two of the retrofits are anticipated to save 50% or more in energy bills and the others - savings are in the 30% to 40% range. Fourteen other retrofits are under way in the three climate zones. Metering equipment has been installed in seven of these retrofits - three in Texas, three in Florida, and one in the Pacific Northwest. This report is an interim update, providing information on the research protocol and status of the PNNL deep energy retrofit project as of December, 2011. The report also presents key findings and lessons learned, based on the body of work to date. In addition, the report summarizes the status of the PNNL Lab Homes that are new manufactured homes procured with minimal energy-efficiency specifications typical of existing homes in the region, and sited on the PNNL campus. The Lab Homes serve as a flexible test facility (the first of its kind in the Pacific Northwest) to rapidly evaluate energy-efficient and grid-smart technologies that are applicable to residential construction.

54 ENVIRONMENTAL SCIENCES↗

Preparation of Aluminum Oxide Films Under Water Exposure – Preliminary Report on 1100 Series Alloys

This report describes laboratory experiments performed to produce oxyhydroxide (oxide) films on aluminum 1100 series alloy substrates at various water/temperature conditions. The aluminum alloys selected in this program are types used on aluminum-clad research reactor fuel, and the water/temperature conditions are selected to produce film structures that would be prototypic to those formed on the fuel as a result of reactor exposure and post-discharge water and/or dry storage exposure. The experimental set-up and results to characterize the oxide morphology, thickness, structure, and chemical composition are reported. The results from this work will be compared to oxide characterizations of fuel cladding alloys that have been exposed to actual reactor and post-discharge service conditions. The aim is to develop a laboratory protocol to produce specimens for further studies for response under drying and radiation conditions. The work in this report is interim results and preliminary information prepared under Task 6, Milestone 6.1 in TTQAP SRNL-RP-2018-00610 as part of the action plan described in Ref. [1]. Additional experimental milestones are in progress and will be reported upon completion.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Monitoring, Reporting, and Verification Considerations for Carbon Dioxide Removal

The project investigates Measurement, Reporting, and Verification (MRV) methods for Enhanced Weathering and Marine Carbon Dioxide Removal (mCDR) technologies. Enhanced Weathering accelerates natural mineral processes to capture CO2, while mCDR leverages oceanic processes for carbon sequestration. The study focuses on developing standardized MRV protocols, assessing environmental impacts, and evaluating the scalability and economic feasibility of these carbon sequestration methods. The goal is to ensure reliable and transparent data for validating and improving CO2 removal technologies.

Priyadarshini↗

Optimization of electroporation method and promoter evaluation for type-1 methanotroph, Methylotuvimicrobium alcaliphilum

Methanotrophic bacteria are promising hosts for methane bioconversion to biochemicals or bioproducts. However, due to limitations associated with long genetic manipulation timelines and, lack of choice in genetic tools required for strain engineering, methanotrophs are currently not employed for bioconversion technologies. In this study, a rapid and reproducible electroporation protocol is developed for type 1 methanotroph, Methylotuvimicrobium alcaliphilum using common laboratory solutions, analyzing optimal electroshock voltages and post-shock cell recovery time. Successful reproducibility of the developed method was achieved when different replicative plasmids were assessed on lab adapted vs. wild-type M. alcaliphilum strains (DASS vs. DSM19304). Overall, a ∼ 3-fold decrease in time is reported with use of electroporation protocol developed here, compared to conjugation, which is the traditionally employed approach. Additionally, an inducible (3-methyl benzoate) and a constitutive (sucrose phosphate synthase) promoter is characterized for their strength in driving gene expression.

59 BASIC BIOLOGICAL SCIENCES↗