Search NASA⌕ Search

SEARCH · Search NASA

Results for “submillimeter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

A novel noncontacting waveguide backshort for millimeter and submillimeter wave frequencies

A new noncontacting waveguide backshort was developed for millimeter and submillimeter wave frequencies. It employs a metallic bar with rectangular or circular holes. The size and spacing of the holes are adjusted to provide a periodic variation of the guide impedance on the correct length scale to give a large reflection of RF frequency power. This design is mechanically rugged and can be easily fabricated for millimeter wave frequencies above 300 GHz where conventional backshorts are difficult to fabricate. Model experiments were performed at 4 to 6 GHz to optimize the design. Values of reflected power greater than 95 percent over a 30 percent bandwidth were achieved. The design was scaled to WR-10 band (75 to 110 GHz) with comparably good results.

Mcgrath, W. R.↗

Report of the heterodyne submillimeter-wave sensors panel

After reviewing the science goals of the Astrotech 21 mission set, and comparing the resulting receiver performance requirements with existing technology, the panel determined that there were significant unmet requirements in four areas: local oscillator power and mixer sensitivity in the Tera-Hz regime, infrared spectrometer channel count, and array technology in any form. A comprehensive development plan has been prepared to provide these capabilities in the time frame needed before technology freeze dates of the respective missions. It was also noted that development of these capabilities has immense payoff for future astrophysics missions, as it opens entire new areas of spectroscopy and imaging in the critical submillimeter wave regime rich in molecular transitions.

Wilson, Robert↗

An adjustable RF tuning element for microwave, millimeter wave, and submillimeter wave integrated circuits

Planar RF circuits are used in a wide range of applications from 1 GHz to 300 GHz, including radar, communications, commercial RF test instruments, and remote sensing radiometers. These circuits, however, provide only fixed tuning elements. This lack of adjustability puts severe demands on circuit design procedures and materials parameters. We have developed a novel tuning element which can be incorporated into the design of a planar circuit in order to allow active, post-fabrication tuning by varying the electrical length of a coplanar strip transmission line. It consists of a series of thin plates which can slide in unison along the transmission line, and the size and spacing of the plates are designed to provide a large reflection of RF power over a useful frequency bandwidth. Tests of this structure at 1 GHz to 3 Ghz showed that it produced a reflection coefficient greater than 0.90 over a 20 percent bandwidth. A 2 GHz circuit incorporating this tuning element was also tested to demonstrate practical tuning ranges. This structure can be fabricated for frequencies as high as 1000 GHz using existing micromachining techniques. Many commercial applications can benefit from this micromechanical RF tuning element, as it will aid in extending microwave integrated circuit technology into the high millimeter wave and submillimeter wave bands by easing constraints on circuit technology.

Lubecke, Victor M.↗

Far-infrared and submillimeter wavelength observations of star-forming dense cores. II - Images

This paper reports on far-infrared and submillimeter wavelength observations of low-mass protostellar candidates. The data set comprises emission maps of nine sources observed over a wavelength range 100-800 microns. The emission is extended at all wavelengths longer than 100 microns. The apparent size of the emission regions is weakly correlated with the beam size and is consistent with an underlying specific intensity profile which is scale-free. The observed emission maps are not circular, but have a mean aspect ratio of 1.3, and the position angles are similar to those determined from maps of molecular emission. The observational results are used in conjunction with theoretical considerations to constrain the physical properties of the putative protostellar envelopes.

Ladd, E. F.↗

Submillimeter horizontal position determination using very long baseline interferometry

An analysis of interferometric phase delays from 15 years of Mark I and Mark III very long baseline interferometry (VLBI) experiments carried out with two radio telescopes in Westford, Massachusetts, about 1.24 km apart, yields weighted root-mean-square (WRMS) scatters about the mean locally horizontal coordinates of 1.0 and 2.0 mm in the north and east directions, respectively. It is concluded that VLBI antennas of at least of the structural quality of the pair in Westford satisfy a necessary but not sufficient condition for being able to maintain a global reference system with submillimeter per year accuracy for intervals in excess of a decade. These data are also used to determine an error model for the VLBI group delay measurements, and, for this particular pair of telescopes, they indicate that the WRMS difference between group and phase delays is composed of a constant part (5.4 mm, for the most recent data) and a SNR term which is about 10 percent larger than that computed theoretically.

Herring, T. A.↗

Submillimeter backward-wave oscillators

A novel submillimeter wave backward-wave oscillator (BWO) that can provide tens of mW of power over a voltage tunable frequency range of more than an octave could serve as the local oscillator for a new class of array sensors in the range from 200 to 2000 GHz. The BWO appears to be the best device available for supporting a wide variety of heterodyne detection systems. It is voltage tunable, able to be phase locked, and can provide sufficient power for all envisioned systems including the arrays of detectors needed for fast data recovery in monitoring upper atmospheric conditions.

Stankiewicz, N.↗

System design for lunar-based optical and submillimeter interferometers

The designs and performances of lunar optical and submillimeter interferometer systems for the Space Exploration Initiative (SEI) are described. Attention is given to the conceptual design of these systems and to the concepts for the launch, transport, deployment, maintenance, and toleration of the lunar environment (both natural and induced by crew activity). Consideration is also given to the requirements for SEI resources (such as cargo space and crew time), the data return concepts, and the flight system technonogy develpment needs.

Gershman, R.↗

A quasioptically stabilized resonant-tunneling-diode oscillator for the millimeter- and submillimeter-wave regions

A semiconfocal open-cavity resonator has been used to stabilize a resonant-tunneling-diode waveguide oscillator at frequencies near 100 GHz. The high quality factor of the open cavity resulted in a linewidth of approximately 10 kHz at 10 dB below the peak, which is about 100 times narrower than the linewidth of an unstabilized waveguide oscillator. This technique is well suited for resonant-tunneling-diode oscillators in the submillimeter-wave region.

Brown, Elliott R.↗

An extension of the high-resolution millimeter- and submillimeter-wave spectrum of methanol to high angular momentum quantum numbers

The high-resolution laboratory millimeter- and submillimeter-wave spectra of C-12H(3)OH and C-13H(3)OH have been extended to include transitions involving significantly higher angular momentum quantum numbers than studied previously. For C-12H(3)OH, the data set now includes 549 A torsional substate transitions and 524 E torsional substate transitions through J is not greater than 24, exclusive of blends. For C-13H(3)OH the data set now includes 453 A torsional substate transitions and 440 E torsional substate transitions through J is not greater than 24, exclusive of blends. The extended internal axis method Hamiltonian has been used to analyze the transitions to experimental accuracy. The molecular constants determined by this approach have been used to predict accurately the frequencies of many transitions through J = 25 not measured in the laboratory.

Anderson, Todd↗

Submillimeter sources for radiometry using high power Indium Phosphide Gunn diode oscillators

A study aimed at developing high frequency millimeter wave and submillimeter wave local oscillator sources in the 60-600 GHz range was conducted. Sources involved both fundamental and harmonic-extraction type Indium Phosphide Gunn diode oscillators as well as varactor multipliers. In particular, a high power balanced-doubler using varactor diodes was developed for 166 GHz. It is capable of handling 100 mW input power, and typically produced 25 mW output power. A high frequency tripler operating at 500 GHz output frequency was also developed and cascaded with the balanced-doubler. A dual-diode InP Gunn diode combiner was used to pump this cascaded multiplier to produce on the order of 0.5 mW at 500 GHz. In addition, considerable development and characterization work on InP Gunn diode oscillators was carried out. Design data and operating characteristics were documented for a very wide range of oscillators. The reliability of InP devices was examined, and packaging techniques to enhance the performance were analyzed. A theoretical study of a new class of high power multipliers was conducted for future applications. The sources developed here find many commercial applications for radio astronomy and remote sensing.

Deo, Naresh C.↗

Varactor diodes for millimeter and submillimeter wavelengths

Whisker-contacted GaAs Schottky barrier varactor diodes are the most common high-frequency multiplier element in use today. They are inherently simple devices that have very high frequency response and have been used to supply local oscillator power for Schottky heterodyne receivers to frequencies approaching 700 GHz. This paper discusses the development of improved varactor diode technology for space based applications at millimeter and submillimeter wavelengths.

Rizzi, Brian J.↗

A Schottky/2-DEG varactor diode for millimeter and submillimeter wave multiplier applications

A new Schottky diode is investigated for use as a multiplier element in the millimeter and submillimeter wavelength regions. The new diode is based on the Schottky contact at the edge of a 2-dimensional electron gas (2-DEG). As a negative voltage is applied to the Schottky contact, the depletion layer between the Schottky contact and the 2-DEG expands and the junction capacitance decreases, resulting in a nonlinear capacitance-voltage characteristic. In this paper, we outline the theory, design, fabrication, and evaluation of the new device. Recent results include devices having cutoff frequencies of 1 THz and above. Preliminary multiplier results are also presented.

Peatman, W. C. B.↗

Zone plate lens antennas for millimeter and submillimeter wavelengths

Zone plate lenses are a type of focusing element which function essentially as differential phase shifters, having a relatively few, coarsely quantized phase delays across the incident beam of radiation. The major advantages are ease of fabrication and much reduced thickness, compared to conventional refractive focusing elements. These considerations are both of particular importance for the submillimeter range, in which manufacturing tolerances for curved optical elements can pose significant problems, and where the absorption of readily available dielectric materials is quite large. In this presentation we briefly review the theory of zone plate lens operations, present a relatively simple method for calculating the aperture efficiency of zone plate lenses used as antennas, and show some theoretical and measured results in the 100 GHz range.

Goldsmith, Paul F.↗

Onset of dispersion in Nb microstrip transmission lines at submillimeter wave frequencies

We have measured the dispersion in phase velocity of a Nb-SiO(x)-Nb microstrip transmission line resonator over a frequency range from 50 GHz to 800 GHz. A submicron Nb/Al-AlO(x)/Nb Josephson junction was used as a voltage-controlled oscillator to excite the high order modes in the resonator. The same junction is used as a direct detector resulting in a series of step-like structures in the DC current-voltage characteristic at the position of each mode frequency. The transmission line is dispersionless up to about 500 GHz where the phase velocity begins to decrease. This is well below the gap frequency f(sub g) approx. equals 700 GHz. Results agree qualitatively with the expected theoretical behavior near f(sub g). This onset of dispersion and loss in Nb transmission lines will have a significant impact on the design of submillimeter wave RF circuits.

Javadi, H. H. S.↗

Resonant tunneling diodes as sources for millimeter and submillimeter wavelengths

High-quality Resonant Tunneling Diodes have been fabricated and tested as sources for millimeter and submillimeter wavelengths. The devices have shown excellent I-V characteristics with peak-to-valley current ratios as high as 6:1 and current densities in the range of 50-150 kA/cm(exp 2) at 300 K. Used as local oscillators, the diodes are capable of state of the art output power delivered by AlGaAs-based tunneling devices. As harmonic multipliers, a frequency of 320 GHz has been achieved by quintupling the fundamental oscillation of a klystron source.

Vanbesien, O.↗

Submillimeter line observations of the proto-planetary nebula CRL 2688

The protoplanetary nebula CRL 2688 with 14-arcsec resolution was observed, and the envelope in CO, (C-13)O, CS, and H(C-13)N was mapped. The submillimeter lines show strong emission from two components of the envelope: a cold, dense, optically thick slow wind and a warm, optically thin fast wind. In the maps, the slow wind appears compact and circularly symmetric. A mass-loss rate in the fast wind of 0.00002 solar mass/yr is estimated, if the wind was continuous. The C-12/C-13 ratio in the fast wind is 5, compared to about 20 in the slow wind. The value in the HCN/CO abundance ratio may be lower in the fast wind than in the slow wind. It is argued that the velocity gradients are not caused by rotation, but rather by asymmetries in the envelope associated with the fast wind.

Jaminet, P. A.↗

Thermal design optimization of a segmented GFRP primary reflector for a submillimeter telescope

Results are presented of a thermal design optimization study of the segmented GFRP primary reflector of the earth-orbiting Submillimeter Imager and Line Survey telescope. The paper examines the thermal requirements of the primary reflector and the thermal environment of the telescope and describes the thermal design of the primary reflector. Particular attention is given to the geometric math model and the thermal math model of the telescope. A summary for the steady-state thermal performance of the optimized design is presented, showing that the optimized design has reduced, by an order of magnitude, structural spatial temperature gradients, which were earlier shown to be the most significant obstacle in maintaining the required telescope figure accuracy.

Tsuyuki, Glenn T.↗

Phasing of a space based segmented submillimeter wavelength telescope using focal plane measurements

As part of a technology development program for realizing a space based submillimeter telescope, two different approaches to the absolute phasing of a segmented primary mirror using focal plane measurements have been implemented for feasibility. The method of optimization by simulated annealing evaluates the image quality of a point spread function after all the telescope segments have been randomly moved. It accepts each iteration which improves the image quality, as well as a random number of iterations which do not, thus keeping the Strehl in the initialization procedure from falling into local maxima. Methods for determining the annealing schedule, and the step size for random segment movements are presented and discussed. Using phase diversity and a model for the telescope imaging system, a nonlinear least squares algorithm has also been implemented which parameterizes each of the segment actuator movements. Using multiple out of focus images, the segment actuator positions are estimated using an iterative procedure. Nonlinear least squares, although computationally intensive, offers a large savings in the actuator movements over simulated annealing and pairwise phasing methods for large numbers of segments. These algorithms have been integrated into a general simulation program which models the behavior of the telescope under anticipated space conditions.

Levine, B. M.↗