At least 289 records · Page 16

NASA charging analyzer program: A computer tool that can evaluate electrostatic contamination

A computer code, the NASA Charging Analyzer Program (NASCAP), was developed to study the surface charging of bodies subjected to geomagnetic substorm conditions. This program will treat the material properties of a surface in a self-consistent manner and calculate the electric fields in space due to the surface charge. Trajectories of charged particles in this electric field can be computed to determine if these particles enhance surface contamination. A preliminary model of the Spacecraft Charging At The High Altitudes (SCATHA) satellite was developed in the NASCAP code and subjected to a geomagnetic substorm environment to investigate the possibility of electrostatic contamination. The results indicate that differential voltages will exist between the spacecraft ground surfaces and the insulator surfaces. The electric fields from this differential charging can enhance the contamination of spacecraft surfaces.

Stevens, N. J.↗

Boundary-layer transition effects on airplane stability and control

Surface contamination of laminar-flow airfoils can significantly modify the location of transition from laminar-to-turbulent boundary-layer flow. The contamination can be the result of insect debris, environmental effects such as ice crystals and moisture due to mist or rain, surface damage, or other contamination adhering to the surface. Location and mode of transition have a dominant effect on the lift-and-drag characteristics of a lifting surface. The influences of laminar boundary-layer flow behavior on airplane stability and control are examined through theoretical results and experimental (wind-tunnel and free-flight) data. For certain airfoils with a relatively steep pressure recovery it is shown that loss of laminar flow near the leading edge can result in premature separation of the turbulent boundary layer and, consequently, in loss of lift and control effectiveness. Aerodynamic modifications which minimize boundary-layer transition effects on airplane stability and control are also discussed.

Van Dam, C. P.↗

Effect of Blown Powder Directed Energy Deposition Angle On Overspray Contamination

Abstract Blown powder directed energy deposition (DED) hybrid machine tools are particularly beneficial when the net shape of a component is to be manufactured in an additive and machined interleaved fashion. This investigation seeks to analyze the effect of the additive head lean angle relative to the part on blown powder DED surface contamination due to overspray. These hybrid DED platforms are commonly installed on multi-axis machining systems where the lean of the deposition head relative to the component surface can be controlled by tilting the component. The blown powder DED process has a 10–50% lower catchment efficiency as compared to wire fed DED systems. This excess powder is still fed towards the deposition location where the particles are heated by the laser and rebound off the melt pool. Some of these heated particles impact the previously machined thin-wall surface. While the deposition process and tool path planning process has been evaluated, the effect of the overspray due to lean angle of the deposition head on the previously thin-wall machined surface is not yet fully understood. This investigation found that minimum lean angle coincides with minimal overspray effect with nearly no contamination. If a lean angle is required, the maximum lean angle possible should be implemented for the smallest effected overspray area on the machined surface which was found to decrease the affect zone by half compared to intermediate lean angles. A diameter divergence was also noticed as the deposition angle was increased. In this study, a thorough analysis of the surface and geometric effects when depositing thin-walled components at varying angles is completed. It has been shown that part quality can be significantly affected by lean angle and thus must be incorporated as an additional design consideration in the manufacturing process.

Heinrich, Lauren↗

A Reduced-Temperature Process for Preparing Atomically Clean Si(100) and SiGe(100) Surfaces with Vapor HF

Silicon processing techniques such as atomic precision advanced manufacturing (APAM) and epitaxial growth require surface preparations that activate oxide desorption (typically >1000 °C) and promote surface reconstruction toward atomically clean, flat, and ordered Si(100)-2 × 1. Here, in this study, we compare the aqueous and vapor phase cleaning of Si and Si/SiGe surfaces to prepare APAM-ready and epitaxy-ready surfaces at lower temperatures. Angle resolved X-ray photoelectron spectroscopy (ARXPS) and Fourier transform infrared (FTIR) spectroscopy indicate that vapor hydrogen fluoride (VHF) cleans dramatically reduce carbon surface contamination and allow the chemically prepared surface to reconstruct at lower temperatures, 600 °C for Si and 580 °C for a Si/Si 0.7 Ge 0.3 heterostructure, into an ordered atomic terrace structure indicated by scanning tunneling microscopy (STM). After thermal treatment and vacuum hydrogen termination, we demonstrate STM hydrogen desorption lithography (HDL) on VHF-treated Si samples, creating reactive zones that enable area-selective chemistry by using a thermal budget similar to CMOS process flows. We anticipate that these results will establish new pathways to integrate APAM with Si foundry processing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Detailed surface analysis of incremental Centrifugal Barrel Polishing (CBP) and EP of single-crystal niobium samples.

Detailed surface analysis of incremental Centrifugal Barrel Polishing (CBP) and EP of single-crystal niobium samples. Ari Palczewski, Hui Tian, Olga Trofimova, Charles Reece Jefferson Lab, Newport News, VA 23606 We performed Centrifugal Barrel Polishing (CBP) on single crystal niobium samples housed in a stainless steel sample holder following a polishing recipe recently developed at FNAL [1]. We were able to obtain a mirror-like finish after the final stage of tumbling, although some defects and imbedded particles remain. Our presentation will discuss the initial results from the coupon study, including qualitative and quantitative analysis of the surface characteristics from each step in the CBP process, followed by HPR and well controlled incremental EP. These will include surface roughness, size and character of contaminants, surface crystal structure, and overall finish. We will discuss how the surface characteristics should guide the SRF community in exploiting or adapting the Fermi recipe; including why minimal subsequent EP is needed, and possible places for modification of the recipe to reduce polishing time. This work is authored by Jefferson Science Associates, LLC under U.S. DOE Contract No. DE-AC05-06OR23177. [1]CA Cooper, LD Cooley , ?Mirror Smooth Superconducting RF Cavities by Mechanical Polishing with Minimal Acid Use,? http://lss.fnal.gov/archive/2011/pub/fermilab-pub-11-032-td.pdf, (May 31, 2011)

Reece, Charles↗

Comparative study of glow discharge wall conditioning using H{sub 2} and Ar-H{sub 2} gas mixture of ADITYA Tokamak vacuum vessel

Low temperature glow discharge wall conditioning (GDC) using H{sub 2} gas is effective in reduction of oxygen and carbon (low-Z) contain impurities on near surface region of vessel wall. The high retention of hydrogen in vessel wall/components due to long operation of H{sub 2} GDC increases hydrogen out-gassing during tokamak operation and affects the production of high temperature plasma. The hydrogen retention can be reduced using inert gas GDC by sputter cleaning for short duration. But in that case the out-gassing rate of inert gas increases, that again impairs the plasma performance. To overcome above problems, the GDC with hydrogen-inert gas mixture can be used for better removal of C and O surface contaminants and low hydrogen retention in surface. In ADITYA tokamak, H{sub 2}-GDC is carried out regularly after plasma operation, while the GDC with argon-hydrogen (Ar-H{sub 2}) mixture has been experimentally tested to observe the reduction of oxygen and carbon impurities along with low hydrogen retention. In Ar-H{sub 2} GDC, the reason being the formation of ArH{sup +} hydride ions, which has quite long life and more energy compared to H{sub 2}{sup +} ions formed in H{sub 2} GDC for breaking the bond of wall molecules. A systematic comparative study of H{sub 2} GDC and Ar-H{sub 2} Mixture GDC by changing the mixture ratio has been carried out in ADITYA tokamak. The relative levels of oxygen and carbon contain impurities have been measured using residual gas analyzer in both GDC's. We have observed a substantial reduction in oxygen and carbon impurities with a significant improvement in wall condition with Ar-H{sub 2} GDC compared to the H{sub 2} GDC. The effect of wall conditioning by Ar-H{sub 2} GDC on the performance of high temperature plasma operation will be presented in this paper. (author)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A New Approach to Predict Hydrogeological Parameters Using Shear Waves from the Multichannel Analysis of Surface Waves Method

For near-surface contaminant characterization, the accurate prediction of hydrogeological parameters in anisotropic and heterogeneous environments has been a challenge since the last decades. However, recent advances in near-surface geophysics have facilitated the use of geophysical data for hydrogeological characterization in the last few years. A pseudo 3-D high resolution P-wave shallow seismic reflection survey was performed at the P Reactor Area, Savannah River Site, South Carolina in order to delineate and predict migration pathways of a large contaminant plume including trichloroethylene. This contaminant plume originates from the northwest section of the reactor facility that is located within the Upper Atlantic Coastal Plain. The data were collected with 40 Hz geophones, an accelerated weight-drop as seismic source and 1 m receiver spacing with near- and far-offsets of 0.5 and 119.5 m, respectively. In such areas with near-surface contaminants, a detailed subsurface characterization of the vadose zone hydraulic parameters is very important. Indeed, an inexpensive method of deriving such parameters by the use of seismic reflection surveys is beneficial, and our approach uses the relationship between seismic velocity and hydrogeological parameters together with empirical observations relating porosity to permeability and hydraulic conductivity. Shear wave velocity ( V s ) profiles were estimated from surface wave dispersion analysis of the seismic reflection data and were subsequently used to derive hydraulic parameters such as porosity, permeability, and hydraulic conductivity. Additional geophysical data including core samples, vertical seismic profiling, surface electrical resistivity tomography, natural gamma and electrical resistivity logs allowed for a robust assessment of the validity and geological significance of the estimated V s and hydrogeological models. The results demonstrate the usefulness of this approach for the upper 15 m of shallow unconsolidated sediments even though the survey design parameters were not optimal for surface wave analysis due to the higher than desired frequency geophones.

Engineering↗

Characteristics of LaB{sub 6} thin films grown by pulsed laser deposition

LaB{sub 6} thin films were deposited at a temperature of 500 °C under vacuum or Ar atmosphere by the pulsed laser deposition technique on (100) Si substrates using a KrF laser. Grazing incidence x-ray diffraction investigations found that films were nanocrystalline, with grain size dimensions from 86 to 102 nm and exhibited microstrain values around 1.1%. Simulations of the x-ray reflectivity curves acquired from the deposited films showed that films had a density around 4.55 g/cm{sup 3}, and were very smooth, with a surface roughness root-mean-square of 1.5 nm, which was also confirmed by scanning electron and atomic force microscopy measurements. All films were covered by a ∼2 nm thick contamination layer that formed when samples were exposed to the ambient. Auger electron spectroscopy investigations found very low oxygen impurity levels below 1.5 at. % once the contamination surface layer was removed by Ar ion sputtering. Four point probe measurements showed that films were conductive, with a resistivity value around 200 μΩ cm for those deposited under Ar atmosphere and slightly higher for those deposited under vacuum. Nanoindentation and scratch investigations showed that films were rather hard, H ∼ 16 GPa, E ∼ 165 GPa, and adherent to the substrate. Thermionic emission measurements indicated a work function value of 2.66 eV, very similar to other reported values for LaB{sub 6}.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Detecting Contamination With Photoelectron Emission

Photoelectron emission from aluminum or epoxy-painted aluminum can be used to reveal presence and concentration of surface contaminants. Emission can be used to locate those parts of surface that are excessively contaminated and to which coatings cannot be reliably bonded. Cleaning can then be done on areas that most need it. Probe moves at rate of typically 1 ft/s (30 cm/s), speed slow enough to ensure sensitivity but fast enough to keep scanning time within reasonable limit.

Smith, T.↗

Analysis of the Monitoring Network at the Salmon, Mississippi, Site

The Salmon site in southern Mississippi was the location of two underground nuclear tests and two methane-oxygen gas explosion tests conducted in the Tatum Salt Dome at a depth of 2,715 feet below ground surface. The U.S. Atomic Energy Commission (a predecessor agency of the U.S. Department of Energy [DOE]) and the U.S. Department of Defense jointly conducted the tests between 1964 and 1970. The testing operations resulted in surface contamination at multiple locations on the site and contamination of shallow aquifers. No radionuclides from the nuclear tests were released to the surface or to groundwater, although radionuclide-contaminated drill cuttings were brought to the surface during re-entry drilling. Drilling operations generated the largest single volume of waste materials, including radionuclide-contaminated drill cuttings and drilling fluids. Nonradioactive wastes were also generated as part of the testing operations. Site cleanup and decommissioning began in 1971 and officially ended in 1972. DOE conducted additional site characterization between 1992 and 1999. The historical investigations have provided a reasonable understanding of current surface and shallow subsurface conditions at the site, although some additional investigation is desirable. For example, additional hydrologic data would improve confidence in assigning groundwater gradients and flow directions in the aquifers. The U.S. Environmental Protection Agency monitored groundwater at the site as part of its Long-Term Hydrologic Monitoring Program from 1972 through 2007, when DOE's Office of Legacy Management (LM) assumed responsibility for site monitoring. The current monitoring network consists of 28 monitoring wells and 11 surface water locations. Multiple aquifers which underlie the site are monitored. The current analyte list includes metals, radionuclides, and volatile organic compounds (VOCs).

54 ENVIRONMENTAL SCIENCES↗

Size Reduction of Contaminated Magnox Pond Skips Using Laser Cutting - 16192

Magnox and TWI Ltd (TWI) have recently developed a first-of-a-kind automated remote laser cutting facility. The facility has been commissioned at Hinkley Point 'A' (HPA) nuclear power station and used to successfully demonstrate the capability of TWI's laser cutting technology to remotely size reduce contaminated Intermediate Level Waste (ILW) Magnox pond skips. The benefits of the facility include reduced cutting times, significantly reduced dose uptake, and significant cost savings. The facility has been designed with a 'plug-and-play' approach such that it could be de-planted and re-mobilised to another nuclear site for other applications. Three contaminated ILW Magnox pond skips with activities of 10.3, 25.1 and 218 GBq/t have been successfully size reduced with this facility; with less than 2.5 hours required to size reduce one skip, and the elapsed laser cutting time being less than 40 minutes. Subsequent radiological assessment showed that the surface contamination and airborne activity were confined within a specifically designed modular containment unit. Continuous real-time air monitoring results indicated a rapid rise and fall of airborne activity. The largest proportion of the airborne activity was removed from the modular containment within 10 minutes by local HEPA ventilation, with the residual activity taking approximately one hour to settle out entirely. The measured dose uptakes were mostly associated with manual handling of the skips to and from the size reduction facility, thus indicating the significance of an automated remote skip size reduction facility. This paper describes the design and performance of the laser skip size reduction facility and presents results of the radiological assessment for three contaminated skips with varying activities. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ultrahigh vacuum and low-temperature cleaning of oxide surfaces using a low-concentration ozone beam

We present a novel method of delivering a low-concentration (<15%) ozone beam to an ultra-high vacuum environment for the purpose of cleaning and dosing experimental samples through oxidation processing. The system described is safe, low-cost, and practical and overcomes the limitations of ozone transport in the molecular flow environment of high or ultrahigh vacuum whilst circumventing the use of pure ozone gas which is potentially highly explosive. The effectiveness of this method in removing surface contamination is demonstrated through comparison of high-temperature annealing of a simple oxide (MgO) in ozone and oxygen environments as monitored using quadrupole mass spectroscopy and Auger electron spectroscopy. Additionally, we demonstrate the potential of ozone for obtaining clean complex oxide surfaces without the need for high-temperature annealing which may significantly alter surface structure.

36 MATERIALS SCIENCE↗

Improved thermoelectrically cooled quartz crystal microbalance

Design changes in the thermoelectrically-cooled quartz microbalance, which is used to monitor surface contamination in space simulation chambers, is described in terms of its extended temperature range, increased temperature control, mass sensitivity, and cooling power. The mass sensor uses 20 MHz quartz crystals having a sensitivity of 8.8 x 10 to the minus tenth power g/sq cm - Hz. The crystals are optically polished, metal plated, and overplated with magnesium fluoride to simulate an optical surface. The microbalance temperature circuitry is designed to readout and control surface temperature between 100 C and minus 59 C to plus or minus 0.5 C, and readout only temperature between minus 60 C and minus 199 C using auxiliary liquid nitrogen cooling. Data is included on the measurement of oil contamination of surfaces as a function of temperature in space simulation chambers.

D. McKeown↗

Flatback airfoil wind tunnel experiment.

A computational fluid dynamics study of thick wind turbine section shapes in the test section of the UC Davis wind tunnel at a chord Reynolds number of one million is presented. The goals of this study are to validate standard wind tunnel wall corrections for high solid blockage conditions and to reaffirm the favorable effect of a blunt trailing edge or flatback on the performance characteristics of a representative thick airfoil shape prior to building the wind tunnel models and conducting the experiment. The numerical simulations prove the standard wind tunnel corrections to be largely valid for the proposed test of 40% maximum thickness to chord ratio airfoils at a solid blockage ratio of 10%. Comparison of the computed lift characteristics of a sharp trailing edge baseline airfoil and derived flatback airfoils reaffirms the earlier observed trend of reduced sensitivity to surface contamination with increasing trailing edge thickness.

17 WIND ENERGY↗

Hydrogen desorption from hydrogen fluoride and remote hydrogen plasma cleaned silicon carbide (0001) surfaces

Due to the extreme chemical inertness of silicon carbide (SiC), in-situ thermal desorption is commonly utilized as a means to remove surface contamination prior to initiating critical semiconductor processing steps such as epitaxy, gate dielectric formation, and contact metallization. In-situ thermal desorption and silicon sublimation has also recently become a popular method for epitaxial growth of mono and few layer graphene. Accordingly, numerous thermal desorption experiments of various processed silicon carbide surfaces have been performed, but have ignored the presence of hydrogen, which is ubiquitous throughout semiconductor processing. In this regard, the authors have performed a combined temperature programmed desorption (TPD) and x-ray photoelectron spectroscopy (XPS) investigation of the desorption of molecular hydrogen (H{sub 2}) and various other oxygen, carbon, and fluorine related species from ex-situ aqueous hydrogen fluoride (HF) and in-situ remote hydrogen plasma cleaned 6H-SiC (0001) surfaces. Using XPS, the authors observed that temperatures on the order of 700–1000 °C are needed to fully desorb C-H, C-O and Si-O species from these surfaces. However, using TPD, the authors observed H{sub 2} desorption at both lower temperatures (200–550 °C) as well as higher temperatures (>700 °C). The low temperature H{sub 2} desorption was deconvoluted into multiple desorption states that, based on similarities to H{sub 2} desorption from Si (111), were attributed to silicon mono, di, and trihydride surface species as well as hydrogen trapped by subsurface defects, steps, or dopants. The higher temperature H{sub 2} desorption was similarly attributed to H{sub 2} evolved from surface O-H groups at ∼750 °C as well as the liberation of H{sub 2} during Si-O desorption at temperatures >800 °C. These results indicate that while ex-situ aqueous HF processed 6H-SiC (0001) surfaces annealed at <700 °C remain terminated by some surface C–O and Si–O bonding, they may still exhibit significant chemical reactivity due to the creation of surface dangling bonds resulting from H{sub 2} desorption from previously undetected silicon hydride and surface hydroxide species.

36 MATERIALS SCIENCE↗

THE ABSORPTION OF HYDROGEN ON LOW PRESSURE HYDRIDE MATERIALS

For this study, hydrogen getter materials (Zircaloy-4 and pure zirconium) that have a high affinity for hydrogen (and low overpressure) have been investigated to determine the hydrogen equilibrium pressure on Zircaloy-4 and pure zirconium. These materials, as with most getter materials, offered significant challenges to overcome given the low hydrogen equilibrium pressure for the temperature range of interest. Hydrogen-zirconium data exists for pure zirconium at 500 C and the corresponding hydrogen overpressure is roughly 0.01 torr. This manuscript presents the results of the equilibrium pressures for the absorption and desorption of hydrogen on zirconium materials at temperatures ranging from 400 C to 600 C. The equilibrium pressures in this temperature region range from 150 mtorr at 600 C to less than 0.1 mtorr at 400 C. It has been shown that the Zircaloy-4 and zirconium samples are extremely prone to surface oxidation prior to and during heating. This oxidation precludes the hydrogen uptake, and therefore samples must be heated under a minimum vacuum of 5 x 10{sup -6} torr. In addition, the Zircaloy-4 samples should be heated at a sufficiently low rate to maintain the system pressure below 0.5 mtorr since an increase in pressure above 0.5 mtorr could possibly hinder the H{sub 2} absorption kinetics due to surface contamination. The results of this study and the details of the testing protocol will be discussed.

08 HYDROGEN↗

Assessment of Electrode Contamination Mitigation at 0.5 MA Scale

The Z Machine at Sandia National Laboratories uses current pulses with peaks up to 27 MA to drive target implosions and generate high energy density conditions of interest for stockpile stewardship programs pertinent to the NNSA program portfolio . Physical processes in the region near the Z Machine target create electrode plasmas which seed parasitic current loss that reduce the performance and output of a Z experiment. Electrode surface contaminants (hydrogen, water, hydrocarbons) are thought to be the primary constituent of electrode plasmas which contribute to loss mechanisms. The Sandia team explore d in situ heating and plasma discharge techniques by integrating requisite infrastructure into Sandia's Mykonos LTD accelerator, addressing potential impacts to accelerator operation, and reporting on the impact of these techniques on electrode plasma formation and shot performance. The in situ discharge cleaning utilizes the electrodes of the accelerator to excite an argon-oxygen plasma to sputter and chemically react contaminants from electrode surfaces. Insulating breaks are required to isolate the plasma in electrode regions where loss processes are most likely to occur. The shots on Mykonos validate that these breaks do not perturb experiment performance, reducing the uncertainty on the largest unknown about the in situ cleaning system. Preliminary observations with electrical and optical diagnostics suggest that electrode plasma formation is delayed, and overall inventory has been substantively reduced. In situ heating embeds cartridge heaters into accelerator electrodes and employs a thermal bakeout to rapidly desorb contaminants from electrode surfaces. For the first time, additively manufactured (AM) electrode assemblies were used on a low impedance accelerator to integrate cooling channels and manage thermal gradients. Challenges with poor supplier fabrication to specifications, load alignment, thermal expansion and hardware movement and warpage appears to have introduced large variability in observed loss, though, preventing strong assertions of loss reduction via in situ heating. At this time, an in situ discharge cleaning process offers the lowest risk path to reduce electrode contaminant inventories on Z, though we recommend continuing to develop both approaches. Additional engineering and testing are required to improve the implementation of both systems. .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗