Search NASA⌕ Search

SEARCH · Search NASA

Results for “targeted quantification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Multiscale modeling of HBV infection integrating intra- and intercellular viral propagation to analyze extracellular viral markers

Chronic infection with hepatitis B virus (HBV) is caused by the persistence of closed circular DNA (cccDNA) in the nucleus of infected hepatocytes. Despite available therapeutic anti-HBV agents, eliminating the cccDNA remains challenging. Thus, quantifying and understanding the dynamics of cccDNA are essential for developing effective treatment strategies and new drugs. However, such study requires repeated liver biopsy to measure the intrahepatic cccDNA, which is basically not accepted because liver biopsy is potentially morbid and not common during hepatitis B treatment. We here aimed to develop a noninvasive method for quantifying cccDNA in the liver using surrogate markers in peripheral blood. We constructed a multiscale mathematical model that explicitly incorporates both intracellular and intercellular HBV infection processes. The model, based on age-structured partial differential equations, integrates experimental data from in vitro and in vivo investigations. By applying this model, we roughly predicted the amount and dynamics of intrahepatic cccDNA within a certain range using specific viral markers in serum samples, including HBV DNA, HBsAg, HBeAg, and HBcrAg. Our study represents a significant step towards advancing the understanding of chronic HBV infection. The noninvasive quantification of cccDNA using our proposed method holds promise for improving clinical analyses and treatment strategies. By comprehensively describing the interactions of all components involved in HBV infection, our multiscale mathematical model provides a valuable framework for further research and the development of targeted interventions.

59 BASIC BIOLOGICAL SCIENCES↗

Integration of a hyphenated HPIC-ICPMS protocol for the measurement of transplutonium isotopic mass distributions for 252Cf campaigns at Oak Ridge National Laboratory

Rapid measurement of transplutonium isotopic mass distributions during 252Cf production campaigns at Oak Ridge National Laboratory is a critical need. Mass measurements for the isotopes of plutonium, americium, curium, and californium are routinely requested to support the α-hydroxy-isobutyrate runs for the purification and recovery of the heavy curium target material and final 249Bk, 252Cf, and 254Es enriched isotope products. This paper presents the integration of an online high-pressure ion chromatography inductively coupled plasma mass spectrometry technique together with the protocol and chemistry that allows for rapid baseline separation and direct quantification of the transplutonium elemental concentrations and isotopic compositions.

Roach, Benjamin↗

Elastic scattering of 3 He + 4 He with the SONIK scattering chamber

Measurements of the elastic scattering cross section of 3 He and 4 He are important in order to improve constraints on theoretical models of 4 He ⁢( 3 He ,𝛾)⁢ 7 Be, a key reaction in Big Bang nucleosynthesis and solar neutrino production. The astrophysical 𝑆 factor for this reaction is a significant source of uncertainty in the standard-solar-model prediction of the 7 Be and 8 B solar neutrino fluxes. The elastic scattering measurements reported in the literature do not extend to low energies and lack proper uncertainty quantification. A new measurement of the 4 He ⁢( 3 He, 3 He)⁢ 4 He reaction has been made at center-of-mass energies 𝐸c.m.=0.38−3.13 MeV using the Scattering of Nuclei in Inverse Kinematics (SONIK) scattering chamber: a windowless, extended gas target surrounded by an array of 30 collimated silicon charged particle detectors situated at TRIUMF. This is the first elastic scattering measurement of 3 He + 4 He made below 500 keV and it has greater angular range and better precision than previous measurements. The elastic scattering data were analyzed using both 𝑅-matrix and halo effective field theory frameworks, and values of the 𝑠-wave scattering length and effective range were extracted. Here, the resulting improvement in knowledge of the 𝑠-wave effective-range function at low energies reduces the overall uncertainty in 𝑆 34 at solar energies.

Elastic scattering reactions↗

SU-G-IeP3-07: High-Resolution, High-Sensitivity Imaging and Quantification of Intratumoral Distributions of Gold Nanoparticles Using a Benchtop L-Shell XRF Imaging System

Purpose: To demonstrate the ability to perform high-resolution imaging and quantification of sparse distributions of gold nanoparticles (GNPs) within ex vivo tumor samples using a highly-sensitive benchtop L-shell x-ray fluorescence (XRF) imaging system. Methods: An optimized L-shell XRF imaging system was assembled using a tungsten-target x-ray source (operated at 62 kVp and 45 mA). The x-rays were filtered (copper: 0.08 mm & aluminum: 0.04 mm) and collimated (lead: 5 cm thickness, 3 cm aperture diameter) into a cone-beam in order to irradiate small samples or objects. A collimated (stainless steel: 4 cm thickness, 2 mm aperture diameter) silicon drift detector, capable of 2D translation, was placed at 90° with respect to the beam to acquire XRF/scatter spectra from regions of interest. Spectral processing involved extracting XRF signal from background, followed by attenuation correction using a Compton scatter-based normalization algorithm. Calibration phantoms with water/GNPs (0 and 0.00001–10 mg/cm{sup 3}) were used to determine the detection limit of the system at a 10-second acquisition time. The system was then used to map the distribution of GNPs within a 12×11×2 mm{sup 3} slice excised from the center of a GNP-loaded ex vivo murine tumor sample; a total of 110 voxels (2.65×10{sup −3} cm{sup 3}) were imaged with 1.3-mm spatial resolution. Results: The detection limit of the current cone-beam benchtop L-shell XRF system was 0.003 mg/cm{sup 3} (3 ppm). Intratumoral GNP concentrations ranging from 0.003 mg/cm{sup 3} (3 ppm) to a maximum of 0.055 mg/cm{sup 3} (55 ppm) and average of 0.0093 mg/cm{sup 3} (9.3 ppm) were imaged successfully within the ex vivo tumor slice. Conclusion: The developed cone-beam benchtop L-shell XRF imaging system can immediately be used for imaging of ex vivo tumor samples containing low concentrations of GNPs. With minor finetuning/optimization, the system can be directly adapted for performing routine preclinical in vivo imaging tasks. Supported by NIH/NCI grant R01CA155446 This investigation was supported by NIH/NCI grant R01CA155446.

60 APPLIED LIFE SCIENCES↗

Hydrologic Model Analyses for Decision Support at the Los Alamos National Laboratory Site - 18363

Modeling hydrologic flow and transport in the subsurface presents a number of challenges including large datasets that contain limited information about the properties of the subsurface and models with a large number of parameters characterizing the properties of the subsurface and the ambient hydrologic conditions (e.g., groundwater recharge). This, in turn, leads to substantial uncertainty in predictions about quantities of interest (e.g., the concentration of a contaminant at points of compliance). We present a number of methods and tools that have recently been developed to address these problems. The model calibration tools are capable of assimilating large datasets (for example, on the order of 1,000,000 model calibration targets) into numerical models, calibrating models with a large number of model parameters (on the order of 1,000,000), or both. These tools leverage recently developed methods in numerical linear algebra such as matrix-free methods and randomized matrix sketching. The uncertainty quantification tools are highly-parallel and enable us to robustly quantify the uncertainties in model parameters (and therefore uncertainty in quantities of interest). Having these capabilities in model analysis tools enables more informed decision making related to remediation of groundwater contaminants. The model analyses that we present are related to the Los Alamos National Laboratory (LANL) chromium site. The analyses are performed by MADS (Model Analysis and Decision Support; http://mads.lanl.gov). (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Quantification of water content by laser induced breakdown spectroscopy on Mars

Laser induced breakdown spectroscopy (LIBS), as performed by the ChemCam instrument, provides a new technique to measure hydrogen at the surface of Mars. Using a laboratory replica of the LIBS instrument onboard the Curiosity rover, different types of hydrated samples (basalts, calcium and magnesium sulfates, opals and apatites) covering a range of targets observed on Mars have been characterized and analyzed in this paper. A number of factors related to laser parameters, atmospheric conditions and differences in targets properties can affect the standoff LIBS signal, and in particular the hydrogen emission peak. Dedicated laboratory tests were run to identify a normalization of the hydrogen signal which could best compensate for these effects and enable the application of the laboratory calibration to Mars data. We check that the hydrogen signal increases linearly with water content; and normalization of the hydrogen emission peak using to oxygen and carbon emission peaks (related to the breakdown of atmospheric carbon dioxide) constitutes a robust approach. Finally, moreover, the calibration curve obtained is relatively independent of the samples types.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Low-Cost alpha Alane for Hydrogen Storage

This project was directed towards the further development of the Savannah River National Laboratory (SRNL) lab-scale electrochemical synthesis of the hydrogen storage material alpha-alane and Ardica Technologies-SRI International (SRI) chemical downstream processes that are necessary to meet DoE cost metrics and transition alpha-alane synthesis to an industrial scale. Ardica has demonstrated the use of alpha-alane in a fuel-cell system for the U.S. Army WFC20 20W soldier power system that has successfully passed initial field trials with individual soldiers. While alpha-alane has been clearly identified as a desirable hydrogen storage material, cost-effective means for its production and regeneration on a scale of use applicable to the industry have yet to be established. We focused on three, principal development areas: 1. The construction of a comprehensive engineering techno-economic model to establish the production costs of alpha-alane by both electrochemical and chemical routes at scale. 2. The identification of critical, cost-saving design elements of the electrochemical cell and the quantification of the product yields of the primary electrochemical process. A moving particle-bed reactor design was constructed and operated. 3. The experimental quantification of the product yields of candidate downstream chemical processes necessary to produce alpha-alane to complete the most cost-effective overall manufacturing process. Our techno-economic model shows that under key assumptions most 2015 and 2020 DOE hydrogen storage system cost targets for low and medium power can be achieved using the electrochemical alane synthesis process. To meet the most aggressive 2020 storage system cost target, $1/g, our model indicates that 420 metric tons per year (MT/y) production of alpha-alane is required. Laboratory-scale experimental work demonstrated that the yields of two of the three critical component steps within the overall “electrochemical process” were sufficiently high to meet this production target. In the case of the yield of the third step, the crystallization of alpha-alane from the primary alane-related product of the electrochemical reaction, further development is required.

08 HYDROGEN↗

In-Situ Reaction Monitoring for Lunar Applications Utilizing a Single Quadrupole Residual Gas Analyzer

With a revived focus to create a permeant presence on the moon and in preparation for future Mars exploration, it is imperative that all re-sources are utilized to their fullest potential. In-Situ Resource Utilization (ISRU) will be critical for future mission success as it would enable independent operation of missions while minimally relying on the complex supply chain created between the Earth, moon and Mars. One of the most critical resources that have been identified for ISRU is the creation of liquid oxygen (O2) for not only breathable air, but also for rocket fuel. On the moon and potentially Mars, one of the most O2 rich resources is in the presence of regolith. Although there are numerous minerals within regolith and various processes to extract O2, this is not the scope of this paper. Since the O2 extraction method can vary, a critical standardized analytical method is needed to verify O2 (or oxygenated precursor compounds) for extraction efficiency and purity. Our group utilizes a modified consumer off-the-shelf (COTS), Residual Gas Analyzer (RGA) Single Quadrupole Mass Spectrometer (QMS). Due to the current field mission requirements, the gas analysis module will need to rely only on mass-to-charge ratios (m/z) and peak intensities to differentiate and quantitate targeted gas-phase reactants or products, i.e. carbon monoxide (CO), carbon dioxide (CO2), methane (CH4) and hydrogen (H2). However, due to solar wind implanted volatiles and various other compounds present in lunar regolith, such as nitrogen (N2), helium (He), and deuterium (D2), deconvolution and quantification of isobaric compounds becomes quite difficult. Specifically, the presence of N2 makes quantification of CO, an oxygenated precursor, difficult due to both compounds having a peak at m/z 28. Approaches to differentiate isobaric components: Initially, the solution to overcome isobaric overlap was to use isotopic ratios, particularly be-tween carbon-13 and nitrogen-15. Although limited literature discuss isotopic composition and attempt to quantify the ratios, variation is particularly high and limited to a few lunar regolith samples. The following were identified as potential approaches to quantify isobaric species, N2 and CO, using our RGA. Threshold Ionization. CO and N2 both have peaks at m/z 28, but only N2 is capable of producing a peak at m/z 7. While a N2 peak at m/z 7 is generally rare, instrument parameters can be optimized in order to maximize the peak intensity. Typically a standard ionization energy of 70 eV is used to monitor a batch process and would produce reliable results for a majority of the reactants or products that we are interested in quantifying. However, to analyze the rare molecular fragment of N2 (N2+ at m/z 7), a different ionization energy may be beneficial. Threshold Ionization Mass Spectrometry (TIMS) will be explored to optimize the N2+ peak at m/z 7 by varying parameters such as ionization energy and pressure. Therefore, a quantitative value at m/z 7 will be used to determine the product gas concentration of N2, which will be subtracted from the total concentration determined at m/z 28 enabling us to approximate the amount of CO. Secondary Detector (infrared gas detector, IR). Another approach to quantitate and differentiate be-tween isobaric components is to leverage alternative modes of detection. Unlike mass spectrometry, which generally uses a separation step prior to analysis (i.e. gas chromatography), IR produces energy that is specifically absorbed depending on the bond and configuration of the molecule. This technique could be leveraged since it is generally only active on non-symmetric molecules, i.e. CO. Utilizing concentrations of CO determined from another detector could help correct concentrations of CO obtained from the QMS. However, the inclusion of another detector adds additional mission requirements, such as power, software changes and avionics updates that add additional cost and schedule requirements.

mass spectrometry↗

In-Situ Reaction Monitoring for Lunar Applications Utilizing a Single Quadrupole Residual Gas Analyzer

With a revived focus to create a permanent presence on the moon and in preparation for future Mars exploration, it is imperative that all resources are utilized to their fullest potential.[1] In-Situ Resource Utilization (ISRU) will be critical for future mission success as it would enable independent operation of missions while minimally relying on the complex supply chain created between the Earth, moon and Mars. One of the most critical resources that have been identified for ISRU is the creation of liquid oxygen(LO2) for not only breathable air, but also for rocket propellant. On the moon and potentially Mars, one of the most O2 rich resources is in the presence of regolith.[2],[3] Although there are numerous minerals within regolith and various processes to extract O2,this is not the scope of this paper. Since the O2 extraction method can vary, a critical standardized analytical method is needed to verify O2(or oxygenated precursor compounds) for extraction efficiency and purity. Our group utilizes a modified consumer off-the-shelf (COTS), Residual Gas Analyzer (RGA) Single Quadrupole Mass Spectrometer (QMS). Due to the current field mission requirements, the gas analysis module will need to rely only on mass-to-charge ratios (m/z) and peak intensities to differentiate and quantitate targeted gas-phase reactants or products, i.e. carbon monoxide(CO), carbon dioxide (CO2), methane (CH4) and hydrogen (H2). However, due to solar wind implanted volatiles and various other compounds present in lunar regolith, such as nitrogen (N2), helium (He), and deuterium (D2), deconvolution and quantification of isobaric compounds becomes quite difficult. Specifically, the presence of N2 makes quantification of CO, an oxygenated precursor, difficult due to both compounds having a peak at m/z 28.

Mass Spectrometry↗

Estimating the cost of saving electricity through U.S. utility customer-funded energy efficiency programs

The program administrator and total cost of saved energy allow comparison of the cost of efficiency across utilities, states, and program types, and can identify potential performance improvements. Comparing program administrator cost with the total cost of saved energy can indicate the degree to which programs leverage investment by participants. Based on reported total costs and savings information for U.S. utility efficiency programs from 2009 to 2013, here we estimate the savings-weighted average total cost of saved electricity across 20 states at 0.046 per kilowatt-hour (kW h), comparing favorably with energy supply costs and retail rates. Programs targeted on the residential market averaged 0.030 per kW h compared to 0.053 per kW h for non-residential programs. Lighting programs, with an average total cost of 0.018 per kW h, drove lower savings costs in the residential market. We provide estimates for the most common program types and find that program administrators and participants on average are splitting the costs of efficiency in half. More consistent, standardized and complete reporting on efficiency programs is needed. Differing definitions and quantification of costs, savings and savings lifetimes pose challenges for comparing program results. Reducing these uncertainties could increase confidence in efficiency as a resource among planners and policymakers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization and Improvement of RNA-Seq Precision in Quantitative Transcript Expression Profiling

Measurement precision determines the power of any analysis to reliably identify significant signals, such as in screens for differential expression, independent of whether the experimental design incorporates replicates or not. With the compilation of large scale RNA-Seq data sets with technical replicate samples, however, we can now, for the first time, perform a systematic analysis of the precision of expression level estimates from massively parallel sequencing technology. This then allows considerations for its improvement by computational or experimental means. Results: We report on a comprehensive study of target coverage and measurement precision, including their dependence on transcript expression levels, read depth and other parameters. In particular, an impressive target coverage of 84% of the estimated true transcript population could be achieved with 331 million 50 bp reads, with diminishing returns from longer read lengths and even less gains from increased sequencing depths. Most of the measurement power (75%) is spent on only 7% of the known transcriptome, however, making less strongly expressed transcripts harder to measure. Consequently, less than 30% of all transcripts could be quantified reliably with a relative error < 20%. Based on established tools, we then introduce a new approach for mapping and analyzing sequencing reads that yields substantially improved performance in gene expression profiling, increasing the number of transcripts that can reliably be quantified to over 40%. Extrapolations to higher sequencing depths highlight the need for efficient complementary steps. In discussion we outline possible experimental and computational strategies for further improvements in quantification precision.

59 BASIC BIOLOGICAL SCIENCES↗

Identifying high-impact and high-uncertainty parameters in MiniFuel model predictions

The MiniFuel irradiation platform at Oak Ridge National Laboratory's High Flux Isotope Reactor (HFIR) is a flexible, high-throughput separate effects test capability. Finite element thermal models are relied upon to design MiniFuel experiments and to achieve experimental objectives. Recent reports show good agreement in the model prediction of target fuel temperatures, but as the capability of the experiments is extended to higher temperatures, the uncertainty in the model predictions must be quantified. To that end, high-impact, high-uncertainty parameters that contribute the most uncertainty to the model are identified. The uncertainty quantification was accomplished through a series of screening and sensitivity analyses. The first analysis utilizes the method of Morris to perform a computationally efficient preliminary screening that considers uncertainty in a large number of the model inputs. The most important parameters identified in the Morris screening study were then considered in a Sobol sensitivity analysis that more robustly ranks and quantifies the uncertainty associated with each parameter. From these analyses, it was determined that thermal contact conductance between components is the parameter that contributes the highest uncertainty. The estimated uncertainty of the MiniFuel model fuel temperature predictions is ±80 °C in the removable beryllium and ±40 °C in the vertical experiment facilities. In conclusion, the framework established by the series of sensitivity analyses presented herein could easily be adapted to fit the needs of accelerated fuel qualification processes.

Fuel, Irradiation↗

Ensemble methods for quantification of potassium oxide in ChemCam Mars and laboratory spectra

In this paper we test new approaches for predicting the amount of element oxides in rock samples from the ChemCam instrument suite onboard the NASA Curiosity rover by focusing on K 2 O. Using the expanded dataset compiled by Gasda et al. (2021) with and without the Earth to Mars (E2M and NoE2M) transformation discussed in Clegg et al. (2017) we trained blended submodels using the “double blending” technique and compared these to ensemble methods (Random Forest, ExtraTrees, and Gradient Boosting Regression). We found that ensemble methods performed similar to blended submodels when looking at RMSE-P on the laboratory spectra and provided significant advantages when looking at spectra coming from Mars. For the full model, blended submodels achieved an RMSE-P of 0.62 and 0.60 (E2M and NoE2M respectively) while Gradient Boosting Regression resulted in a slightly improved RMSE-P of 0.59 and 0.60. More importantly, by employing a local RMSE-P estimation technique where model performance is evaluated based on nearby test samples we found that using ensemble methods can lower the quantification limit for K 2 O from the current value of ≈0.6 wt% to ≈0.08 wt% using Extra Trees and Random Forest. This would allow for a much larger range of K 2 O values to be quantified on Mars with greater certainty given that most targets seen on Mars tend to have <1 wt% K2O. Finally, we used both Mean Decrease in Impurity (MDI) and permutation importance techniques to investigate the wavelengths used by the ensemble methods and found that they correspond to known potassium emission lines. This suggests that ensemble methods can provide an easier to train and improved alternative to blended submodels for predicting potassium compositions from Laser Induced Breakdown Spectroscopy (LIBS) data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optical conductivity-based ultrasensitive mid-infrared biosensing on a hybrid metasurface

Abstract Optical devices are highly attractive for biosensing as they can not only enable quantitative measurements of analytes but also provide information on molecular structures. Unfortunately, typical refractive index-based optical sensors do not have sufficient sensitivity to probe the binding of low-molecular-weight analytes. Non-optical devices such as field-effect transistors can be more sensitive but do not offer some of the significant features of optical devices, particularly molecular fingerprinting. We present optical conductivity-based mid-infrared (mid-IR) biosensors that allow for sensitive and quantitative measurements of low-molecular-weight analytes as well as the enhancement of spectral fingerprints. The sensors employ a hybrid metasurface consisting of monolayer graphene and metallic nano-antennas and combine individual advantages of plasmonic, electronic and spectroscopic approaches. First, the hybrid metasurface sensors can optically detect target molecule-induced carrier doping to graphene, allowing highly sensitive detection of low-molecular-weight analytes despite their small sizes. Second, the resonance shifts caused by changes in graphene optical conductivity is a well-defined function of graphene carrier density, thereby allowing for quantification of the binding of molecules. Third, the sensor performance is highly stable and consistent thanks to its insensitivity to graphene carrier mobility degradation. Finally, the sensors can also act as substrates for surface-enhanced infrared spectroscopy. We demonstrated the measurement of monolayers of sub-nanometer-sized molecules or particles and affinity binding-based quantitative detection of glucose down to 200 pM (36 pg/mL). We also demonstrated enhanced fingerprinting of minute quantities of glucose and polymer molecules.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Doubly Curved Crystal Monochromatic XRF Instrumentation for Materials Characterization

The advent of doubly curved crystals (DCC) in XRF instrumentation offers new capabilities for materials characterization. The DCCs are unique in that they provide both point-to-point focusing as well as monochromatic treatment of the x-ray passing through the crystal. The advantages of the focusing and monochromatic treatments include: small spot focusing on the sample when used with an appropriate source and monochromatic excitation and monochromatic collection of elemental emission. hiRX (monochromatic wavelength dispersive XRF) employs all of these features into one instrumental package. The small spot size of the source (around 200 micrometers) is focused on a sample with a DCC coupled to the source to provide monochromatic excitation. The monochromatic excitation offers increased x-ray flux at the characteristic line of the x-ray anode (in this case Rh Ka1). Another DCC which has been selected for a specific energy/element is used to collect the emitted x-rays for the target analyte. The combination of low background excitation and narrow band (100-200 eV) collection offers high sensitivity and elemental selectivity. The performance of hiRX compared to conventional MXRF and confocal MXRF offers insights into the advantages and disadvantages of each methodology for Pu detection and quantification. These features are highlighted in the analysis of a Pu contaminated soil particle.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

IAEA Coordinated Research Project on HTGR Reactor Physics, Thermal-hydraulics and Depletion Uncertainty Analysis

The continued development of High Temperature Gas Cooled Reactors (HTGRs) requires verification of HTGR design and safety features with reliable high fidelity physics models and robust, efficient, and accurate codes. The predictive capability of coupled neutronics/thermal-hydraulics and depletion simulations for reactor design and safety analysis can be assessed with sensitivity analysis (SA) and uncertainty analysis (UA) methods. Uncertainty originates from errors in physical data, manufacturing uncertainties, modelling and computational algorithms. (The interested reader is referred to the large body of published SA and UA literature for a more complete overview of the various types of uncertainties, methodologies and results obtained). SA is helpful for ranking the various sources of uncertainty and error in the results of core analyses. SA and UA are required to address cost, safety, and licensing needs and should be applied to all aspects of reactor multi-physics simulation. SA and UA can guide experimental, modelling, and algorithm research and development. Current SA and UA rely either on derivative-based methods such as stochastic sampling methods or on generalized perturbation theory to obtain sensitivity coefficients. Neither approach addresses all needs. In order to benefit from recent advances in modelling and simulation and the availability of new covariance data (nuclear data uncertainties) extensive sensitivity and uncertainty studies are needed for quantification of the impact of different sources of uncertainties on the design and safety parameters of HTGRs. Only a parallel effort in advanced simulation and in nuclear data improvement will be able to provide designers with more robust and well validated calculation tools to meet design target accuracies. In February 2009, the Technical Working Group on Gas-Cooled Reactors (TWG-GCR) of the International Atomic Energy Agency (IAEA) recommended that the proposed Coordinated Research Program (CRP) on the HTGR Uncertainty Analysis in Modelling (UAM) be implemented. This CRP is a continuation of the previous IAEA and Organization for Economic Co-operation and Development (OECD)/Nuclear Energy Agency (NEA) international activities on Verification and Validation (V&V) of available analytical capabilities for HTGR simulation for design and safety evaluations. Within the framework of these activities different numerical and experimental benchmark problems were performed and insight was gained about specific physics phenomena and the adequacy of analysis methods.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Molecular Ionic Composites: A New Class of Polymer Electrolytes to Enable All-Solid-State and High-Voltage Lithium Batteries (Final Project Report for DOE EERE VTO grant EE0008860)

Based on a newly discovered class of solid PE materials, that is, molecular ionic composites (MICs), the major goal of this project is to develop solid-state lithium conductors targeted for use in transportation applications. MICs form a mechanically stiff, electrochemically stable, and thermally stable matrix. Specific objectives include the following: (1) development of robust MIC electrolyte thin films (~ 20 µm) to serve as simultaneous nonflammable separators and dendrite-blocking Li + conductors, (2) electrochemical quantification of key performance metrics including electrolyte stability, interfacial reactions, and suitability/compatibility with a range of electrode materials, and (3) comprehensive investigation of ion transport mechanisms and electrode-electrolyte interfacial reactivity under practical operating conditions using NMR and synchrotron X-ray analyses.

25 ENERGY STORAGE↗

Uncertainty quantification given discontinuous climate model response and a limited number of model runs.

Uncertainty quantification in complex climate models is challenged by the sparsity of available climate model predictions due to the high computational cost of model runs. Another feature that prevents classical uncertainty analysis from being readily applicable is bifurcative behavior in climate model response with respect to certain input parameters. A typical example is the Atlantic Meridional Overturning Circulation. The predicted maximum overturning stream function exhibits discontinuity across a curve in the space of two uncertain parameters, namely climate sensitivity and CO2 forcing. We outline a methodology for uncertainty quantification given discontinuous model response and a limited number of model runs. Our approach is two-fold. First we detect the discontinuity with Bayesian inference, thus obtaining a probabilistic representation of the discontinuity curve shape and location for arbitrarily distributed input parameter values. Then, we construct spectral representations of uncertainty, using Polynomial Chaos (PC) expansions on either side of the discontinuity curve, leading to an averaged-PC representation of the forward model that allows efficient uncertainty quantification. The approach is enabled by a Rosenblatt transformation that maps each side of the discontinuity to regular domains where desirable orthogonality properties for the spectral bases hold. We obtain PC modes by either orthogonal projection or Bayesian inference, and argue for a hybrid approach that targets a balance between the accuracy provided by the orthogonal projection and the flexibility provided by the Bayesian inference - where the latter allows obtaining reasonable expansions without extra forward model runs. The model output, and its associated uncertainty at specific design points, are then computed by taking an ensemble average over PC expansions corresponding to possible realizations of the discontinuity curve. The methodology is tested on synthetic examples of discontinuous model data with adjustable sharpness and structure.

54 ENVIRONMENTAL SCIENCES↗