Search NASA⌕ Search

SEARCH · Search NASA

Results for “test case”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Open-source MFIX-DEM software for gas-solids flows: Part II — Validation studies

With rapid advancements in computer hardware and numerical algorithms, computational fluid dynamics (CFD) has been increasingly employed as a useful tool for investigating the complex hydrodynamics inherent in multiphase flows. An important step during the development of a CFD model and prior to its application is conducting careful and comprehensive verification and validation studies. Accordingly, efforts to verify and validate the open-source MFIX-DEM software, which can be used for simulating the gas–solids flow using an Eulerian reference frame for the continuum fluid and a Lagrangian discrete framework (Discrete Element Method) for the particles, have been made at the National Energy Technology Laboratory (NETL). In part I of this paper, extensive verification studies were presented and in this part, detailed validation studies of MFIX-DEM are presented. A series of test cases covering a range of gas–solids flow applications were conducted. In particular the numerical results for the random packing of a binary particle mixture, the repose angle of a sandpile formed during a side charge process, velocity, granular temperature, and voidage profiles from a bounded granular shear flow, lateral voidage and velocity profiles from a monodisperse bubbling fluidized bed, lateral velocity profiles from a spouted bed, and the dynamics of segregation of a binary mixture in a bubbling bed were compared with available experimental data, and in some instances with empirical correlations. In addition, sensitivity studies were conducted for various parameters to quantify the error in the numerical simulation.

42 ENGINEERING↗

Oscillatory Spreading and Inertia in Power Grids

The increase in variable renewable generators (VRGs) in power systems has altered the dynamics from a historical experience. VRGs introduce new sources of power oscillations, and the stabilizing response provided by synchronous generators (SGs, e.g., natural gas, coal, etc.), which help avoid some power fluctuations, will lessen as VRGs replace SGs. These changes have led to the need for new methods and metrics to quickly assess the likely oscillatory behavior for a particular network without performing computationally expensive simulations. This work studies the impact of a critical dynamical parameter - the inertia value - on the rest of a power system's oscillatory response to representative VRG perturbations. We use a known localization metric in a novel way to quantify the number of nodes responding to a perturbation and the magnitude of those responses. This metric allows us to relate the spread and severity of a system's power oscillations with inertia. We find that as inertia increases, the system response to node perturbations transitions from localized (only a few close nodes respond) to delocalized (many nodes across the network respond). We introduce a heuristic computed from the network Laplacian to relate this oscillatory transition to the network structure. We show that our heuristic accurately describes the spread of oscillations for a realistic power-system test case. Using a heuristic to determine the likely oscillatory behavior of a system given a set of parameters has wide applicability in power systems, and it could decrease the computational workload of planning and operation.

dynamical systems↗

Efficient algorithm for locating and sizing series compensation devices in large power transmission grids: II. Solutions and applications

In a companion manuscript, we developed a novel optimization method for placement, sizing, and operation of Flexible Alternating Current Transmission System (FACTS) devices to relieve transmission network congestion. Specifically, we addressed FACTS that provide Series Compensation (SC) via modification of line inductance. In this manuscript, this heuristic algorithm and its solutions are explored on a number of test cases: a 30-bus test network and a realistically-sized model of the Polish grid (~ 2700 nodes and ~ 3300 lines). The results on the 30-bus network are used to study the general properties of the solutions including non-locality and sparsity. The Polish grid is used as a demonstration of the computational efficiency of the heuristics that leverages sequential linearization of power flow constraints and cutting plane methods that take advantage of the sparse nature of the SC placement solutions. Using these approaches, the algorithm is able to solve an instance of Polish grid in tens of seconds. We explore the utility of the algorithm by analyzing transmission networks congested by (a) uniform load growth, (b) multiple overloaded configurations, and (c) sequential generator retirements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Efficient Algorithm for Locating and Sizing Series Compensation Devices in Large Transmission Grids: Solutions and Applications (PART II)

In a companion manuscript, we developed a novel optimization method for placement, sizing, and operation of Flexible Alternating Current Transmission System (FACTS) devices to relieve transmission network congestion. Specifically, we addressed FACTS that provide Series Compensation (SC) via modification of line inductance. In this manuscript, this heuristic algorithm and its solutions are explored on a number of test cases: a 30-bus test network and a realistically-sized model of the Polish grid (~2700 nodes and ~3300 lines). The results on the 30-bus network are used to study the general properties of the solutions including non-locality and sparsity. The Polish grid is used as a demonstration of the computational efficiency of the heuristics that leverages sequential linearization of power flow constraints and cutting plane methods that take advantage of the sparse nature of the SC placement solutions. Using these approaches, the algorithm is able to solve an instance of Polish grid in tens of seconds. We explore the utility of the algorithm by analyzing transmission networks congested by (a) uniform load growth, (b) multiple overloaded configurations, and (c) sequential generator retirements

25 ENERGY STORAGE↗

PMU Data Integrity Evaluation through Analytics on a Virtual Test-Bed

Power systems are rapidly becoming populated by phasor measurement units (PMUs) in ever increasing numbers. PMUs are critical components of today s energy management systems, designed to enable near real-time wide area monitoring and control of the electric power system. They are able to measure highly accurate bus voltage phasors as well as branch current phasors incident to the buses at which PMUs are equipped. Synchrophasor data is used for applications varying from state estimation, islanding control, identifying outages, voltage stability detection and correction, disturbance recording, and others. However, PMU-measured readings may suffer from errors due to meter biases or drifts, incorrect configurations, or even cyber-attacks. Furthermore, the testing of early PMUs showed a large disparity between the reported values from PMUs provided by different manufacturers, particularly when frequency was off-nominal, during dynamic events, and when harmonic/inter-harmonic content was present. Detection and identification of PMU gross measurement errors are thus crucial in maintaining highly accurate phasor readings throughout the system. In this paper, we present our work in conducting analytics to determine the trustworthiness and worth of the PMU readings collected across an electric network system. By implementing the IEEE 118 bus test case on a virtual test bed (VTB) , we are able to emulate PMU readings (bus voltage and branch current phasors in addition to bus frequencies) under normal and abnormal conditions using (virtual) PMU sensors deployed across major substations in the network. We emulate a variety of failures such as bus, line, transformer, generator, and/or load failures. Data analytics on the voltage phase angles and frequencies collected from the PMUs show that specious (or compromised) PMU device(s) can be identified through abnormal behaviour by comparing the trend of its frequency and phase angle reading with the ensemble of all other PMU readings in the network. If the reading trend of a particular PMU deviates from the weighted average of the reading trends of other PMUs at nearby substations, then it is likely that the PMU is malfunctioning. We assign a weight to each PMU denoting how electric-topology-wise close it is from where the PMU under consideration is located. The closer a PMU is, the higher the weight it has. To compute the closeness between two nodes in the power network, we employ a form of the resistance distance metric. It computes the electrical distance by taking into consideration the underlying topology as well as the physical laws that govern the electrical connections or flows between the network components. The detection accuracy of erroneous PMUs should be improved by employing this metric. We present results to validate the proposed approach. We also discuss the effectiveness of using an end-to-end VTB approach that allows us to investigate different types of failures and their responses as seen by the ensemble of PMUs. The collected data on certain types of events may be amenable to certain types of analysis (e.g., alerting for sudden changes can be done on a small window of data) and hence determine the data analytics architectures is required to evaluate the streaming PMU data.

and data analytics architecture.↗

New Whole-House Solutions Case Study: Testing Ductless Heat Pumps in High-Performance Affordable Housing, the Woods at Golden Given - Tacoma, Washington

The Woods is a 30-home, high- performance, energy efficient sustainable community built by Habitat for Humanity (HFH). With Support from Tacoma Public Utilities, Washington State University (part of the Building America Partnership for Improved Residential Construction) is researching the energy performance of these homes and the ductless heat pumps (DHP) they employ. This project provides Building America with an opportunity to: field test HVAC equipment, ventilation system air flows, building envelope tightness, lighting, appliance, and other input data that are required for preliminary Building Energy Optimization (BEopt™) modeling and ENERGY STAR® field verification; analyze cost data from HFH and other sources related to building-efficiency measures that focus on the DHP/hybrid heating system and heat recovery ventilation system; evaluate the thermal performance and cost benefit of DHP/hybrid heating systems in these homes from the perspective of homeowners; compare the space heating energy consumption of a DHP/electric resistance (ER) hybrid heating system to that of a traditional zonal ER heating system; conduct weekly "flip-flop tests" to compare space heating, temperature, and relative humidity in ER zonal heating mode to DHP/ER mode.

Appliance↗

FINITE ELEMENT ANALYSIS OF BULK TRITIUM SHIPPING PACKAGE

The Bulk Tritium Shipping Package was designed by Savannah River National Laboratory. This package will be used to transport tritium. As part of the requirements for certification, the package must be shown to meet the scenarios of the Hypothetical Accident Conditions (HAC) defined in Code of Federal Regulations Title 10 Part 71 (10CFR71). The conditions include a sequential 30-foot drop event, 30-foot dynamic crush event, and a 40-inch puncture event. Finite Element analyses were performed to support and expand upon prototype testing. Cases similar to the tests were evaluated. Additional temperatures and orientations were also examined to determine their impact on the results. The peak stress on the package was shown to be acceptable. In addition, the strain on the outer drum as well as the inner containment boundary was shown to be acceptable. In conjunction with the prototype tests, the package was shown to meet its confinement requirements.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Phasor Measurement Units Optimal Placement and Performance Limits for Fault Localization

Here, the performance limits of faults localization are investigated using synchrophasor data. The focus is on a non-trivial operating regime where the number of Phasor Measurement Unit (PMU) sensors available is insufficient to have full observability of the grid state. Proposed analysis uses the Kullback Leibler (KL) divergence between the distributions corresponding to different fault location hypotheses associated with the observation model. This analysis shows that the most likely locations are concentrated in clusters of buses more tightly connected to the actual fault site akin to graph communities. Consequently, a PMU placement strategy is derived that achieves a near-optimal resolution for localizing faults for a given number of sensors. The problem is also analyzed from the perspective of sampling a graph signal, and how the placement of the PMUs i.e. the spatial sampling pattern and the topological characteristic of the grid affect the ability to successfully localize faults. To highlight the superior performance of presented fault localization and placement algorithms, the proposed strategy is applied to a modified IEEE 34, IEEE-123 bus test cases and to data from a real distribution grid. Additionally, the detection of cyber-physical attacks is also examined where PMU data and relevant Supervisory Control and Data Acquisition (SCADA) network traffic information are compared to determine if a network breach has affected the integrity of the system information and/or operations.

42 ENGINEERING↗

Vector-model-supported approach in prostate plan optimization

Lengthy time consumed in traditional manual plan optimization can limit the use of step-and-shoot intensity-modulated radiotherapy/volumetric-modulated radiotherapy (S&S IMRT/VMAT). A vector model base, retrieving similar radiotherapy cases, was developed with respect to the structural and physiologic features extracted from the Digital Imaging and Communications in Medicine (DICOM) files. Planning parameters were retrieved from the selected similar reference case and applied to the test case to bypass the gradual adjustment of planning parameters. Therefore, the planning time spent on the traditional trial-and-error manual optimization approach in the beginning of optimization could be reduced. Each S&S IMRT/VMAT prostate reference database comprised 100 previously treated cases. Prostate cases were replanned with both traditional optimization and vector-model-supported optimization based on the oncologists' clinical dose prescriptions. A total of 360 plans, which consisted of 30 cases of S&S IMRT, 30 cases of 1-arc VMAT, and 30 cases of 2-arc VMAT plans including first optimization and final optimization with/without vector-model-supported optimization, were compared using the 2-sided t-test and paired Wilcoxon signed rank test, with a significance level of 0.05 and a false discovery rate of less than 0.05. For S&S IMRT, 1-arc VMAT, and 2-arc VMAT prostate plans, there was a significant reduction in the planning time and iteration with vector-model-supported optimization by almost 50%. When the first optimization plans were compared, 2-arc VMAT prostate plans had better plan quality than 1-arc VMAT plans. The volume receiving 35 Gy in the femoral head for 2-arc VMAT plans was reduced with the vector-model-supported optimization compared with the traditional manual optimization approach. Otherwise, the quality of plans from both approaches was comparable. Vector-model-supported optimization was shown to offer much shortened planning time and iteration number without compromising the plan quality.

61 RADIATION PROTECTION AND DOSIMETRY↗

Field and Model Data Associated with the Manuscript “Drivers of Streamflow Intermittency in Humid Regions: 1. Evaluating Above- and Below-ground Controls of Flow Persistence in a Forested Catchment”

This package contains field data, modeling files, and scripts supporting the investigation of the drivers of streamflow intermittency in a forested catchment. It includes the field data collected from electrical resistivity tomography (ERT) surveys, ground penetrating radar (GPR), continuous self-potential (SP) monitoring, electromagnetic (EM) imaging, groundwater and stilling well. In addition, it contains the data and results of the coupled water- and electrical-flow model developed using the COMSOL Multiphysics and Advanced Terrestrial Simulator (ATS), as well as software files and Jupyter notebooks used to process the data and generate figures in the manuscript submitted for peer review. The data archive is organized in the following directories: 1) Climate Includes hourly precipitation and daily evapotranspiration time series (2024 – 2025) provided as CSV files, alongside a text file detailing dataset units. 2) Coupled_model Contains two subfolders: Synthetic and Field_Application subfolder. Synthetic subfolder contains the ATS XML input script (can be opened using any code editor) for the four synthetic hydrological cases tested (Connected and gaining, Connected and losing, Disconnected and losing, and dry stream). It also includes other experimental cases to test the influence of precipitation and concentration gradient. For each synthetic case, the flow model simulation is executed using the ATS XML scripts and the included Python script (generate_data_set.py) to convert ATS output to COMSOL-ready input. COMSOL Multiphysics template (.mph can be opened with the commercial software COMSOL and requires a license) is executed using the ATS output data to simulate the potential field. It also includes the Synthetic_model_plot.ipynb (can be opened using any code editor) to visualize the SP result and generate manuscript figures. The data subfolder contains mesh files to run both the ATS (.exo and .stl files can be viewed using Paraview; .h5 files can be opened using HDFView software and h5py Python package) and COMSOL models. Field_Application subfolder contains two subfolders: ES_MDA_inversion and Final_Model. ES_MDA_inversion contains the Python script (.py can be opened using any code editor) and SP observation data used to run the Ensemble Smoother with Multiple Data Assimilation (ES-MDA) inversion sequence to get the optimal model parameters. The Final_model subfolder contains the ATS XML input scripts, data files, output data for the two SP sites. The same workflow steps outlined for the Synthetic subfolder apply here. It also contains the Jupyter notebook (Plot_final_calib.ipynb) to visualize the results of the modeled SP, stream-groundwater exchange and moisture content. 3) Discharge Includes the electrical conductivity (EC) time series (provided as CSV files) from salt slug injections. It also includes the Jupyter notebook (Discharge_process.ipynyb) used to estimate discharge. All discharge measurements collated into rating_curve_processed.csv 4) EM Contains the CSV file of the EM data from the DUALEM-42, including spatial coordinates (x, y, z), apparent conductivity, and in-phase measurements at 2 m coil separations for horizontal coplanar (HCP) and perpendicular (PRP) geometries. 5) ERT Contains raw resistivity data (provided as CSV files), spatial location of each of the electrodes (provided as CSV files), and files used for the resistivity inversion (.resipy can be opened with the open-source ResIPy software). 6) GPR Includes GPR field datasets collected at 100 MHz and 250 MHz antenna frequencies, along with the processing/interpretation project file (GPR_process.gpz can be viewed using EKKO_Project 6, a commercial software by Sensors & Software that requires a license). 7) Slug_test Includes the slug test data at all the groundwater wells provided as CSV files, as well as the Jupyter notebook (Slug_test.ipynb) for calculating hydraulic conductivity. 8) SP Contains the SP data collected in field at the two SP sites (one in the perennial reach and the other in the intermittent reach), provided as DAT files. 9) Well_data Contains two subfolders: 1) Raw, which provides unprocessed pressure, electrical conductivity and temperature timeseries downloaded from the loggers in all the groundwater and stilling wells, and 2) Processed, which contains sorted, QA/QC timeseries data for each well. The data archive also contains data_process.ipynb, a Jupyter notebook used for field data analysis and generating figures (plotting well, SP, climate, and discharge data, as well as calculating head gradient at sites with nested groundwater wells). It also includes DTW.ipynb, a Jupyter notebook containing the code for the dynamic time warping (DTW) with sliding window to evaluate SP signal synchronicity.

ATS↗

Generalizing the compressible pairwise interaction extended point-particle model

Ejecta physics plays an important role in material interfaces that are impacted by a strong shock wave. When a shock impacts a rough surface of solid material and melts it, the Richtmyer–Meshkov instability grows perturbations on the surface, which can eject particles. After release, the ejecta travel through the post-shock compressible flow. To accurately simulate a large number of ejecta particles, an Euler–Lagrange approach is preferred, which requires modeling the subgrid-scale physics involved with fluid–particle interactions. We generalize the previous work from Hsiao et al. (2023) to consider systems of moving particles subject to any loading shock. The following improvements were made: (1) Particles are allowed to move relative to each other (2) Non-planar shocks are accounted for along with allowing for variable shock speeds. As a result, the generalized algorithm was tested with particle-resolved simulations for canonical test cases. The results of these tests are discussed and analyzed.

97 MATHEMATICS AND COMPUTING↗

Verification test suite for systems analysis tools

This report documents strategies and test problems to support Verification and Validation (V&V) of the systems analysis tools currently being developed under the Reactor Product Line (RPL) of DOE’s Nuclear Energy Advanced Modeling and Simulation (NEAMS) program. A suite of verification test cases has been developed. This test suite supports development of new codes as well as maintenance of existing codes. For advanced tools that are under development like RELAP-7 for light water reactor analysis [1] and the MOOSE based component models for SFR (M-SFR) analyses [2], verification of simulation results must be performed throughout the entire development phase. This test suite is also useful for established codes as part of automated testing to ensure that general code maintenance does not change existing results.

Sumner, T.↗

Leading in Los Angeles: Demonstrating scalable emerging energy efficient technologies for integrated façade, lighting, and plug loads INTER System FLEXLAB Test Report

This report is a part of the California Energy Commission (Energy Commission) EPIC study Leading in Los Angeles: Demonstrating scalable emerging energy efficient technologies for integrated façade, lighting, and HVAC. The set of technologies are called the Integrated Technologies for Energy-efficient Retrofits (INTER) and are comprised of automated shading products and LED lighting systems with networked luminaire-level sensors and controls. In addition, the project will include control modifications and assessments of HVAC savings. This document includes the test plan and test results for the FLEXLAB® testing of the shading and lighting INTER system and related energy use impact. The test plan describes the test objectives and features, test cases, schedule, and measurements. The test results cover system performance in the lab; including lighting and HVAC energy, visual comfort, and thermal comfort.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Verification of RESRAD-BUILD Code Version 4

This report documents the verification of the RESRAD-BUILD code, Version 4.0, which was released on December 22, 2022. Two earlier reports verifying Versions 3.0 and 3.1, respectively, were published in 2001 (Kamboj, et al. 2001) and 2003 (Tetra Tech NUS 2003). Version 4.0 of the RESRAD-BUILD code has many new features and modeling enhancements over the earlier versions, including the previously released Version 3.5. Chapter 2 of this report focuses on verifying the external dose and risk modeling for point, line, area, and volume sources, as well as for floor deposition. Besides verification, the external radiation doses calculated by RESRAD-BUILD were also benchmarked with those calculated by the MCNP code (Briemeister 1993). Section J.3 of the RESRAD-BUILD User’s Manual Vol. 1 (Yu et al. 2022) documents the results of that benchmarking effort. Chapter 3 of this report focuses on verifying the ventilation modeling, from checking the remaining source inventory, releases of radionuclides to the air, air concentrations and deposited floor concentrations over time, to the radiation dose and risk associated with inhalation, ingestion, and air submersion, with and without vacuuming. The verification efforts involve designing spreadsheets to perform calculations the same as or like those performed by the RESRAD-BUILD code and then comparing the spreadsheet results with those produced by the code. When the results agree or the differences are within acceptable range, the accuracy of model implementation in the code is verified. In addition to model implementation, the implementation of key functions and features that facilitate the modeling or the use of the code were also verified during the release testing of the code. Appendix A presents the test cases developed for these verification testing, and Appendix B presents the testing results that verify proper implementation of key functions and features.

54 ENVIRONMENTAL SCIENCES↗

Progress and investigation on lattice Boltzmann modeling of multiple immiscible fluids or components with variable density and viscosity ratios

Lattice Boltzmann models for simulating multiphase flows are relatively new, and much work remains to be done to demonstrate their ability to solve fundamental test cases before they are considered for engineering problems. From this perspective, a hydrodynamic lattice Boltzmann model for simulating immiscible multiphase flows with high density and high viscosity ratios, up to O(1000) and O(100) respectively, is presented and validated against analytical solutions. The method is based on a two phase flow model with operators extended to handle N immiscible fluids. The current approach is O(N) in computational complexity for the number of different gradient approximations. This is a major improvement, considering the O(N{sup 2}) complexity found in most works. A sequence of systematic and essential tests have been conducted to establish milestones that need to be met by the proposed approach (as well as by other methods). First, the method is validated qualitatively by demonstrating its ability to address the spinodal decomposition of immiscible fluids. Second, the model is quantitatively verified for the case of multilayered planar interfaces. Third, the multiphase Laplace law is studied for the case of three fluids. Fourth, a quality index is developed for the three-phase Laplace–Young’s law, which concerns the position of the interfaces between the fluids resulting from the different surface tensions. The current model is compatible with the analytical solution, and is shown to be first order accurate in terms of this quality index. Finally, the multilayered Couette’s flow is studied. In this study, numerical results can recover the analytical solutions for all the selected test cases, as long as unit density ratios are considered. For high density and high viscosity ratios, the analytical solution is recovered for all tests, except that of the multilayered Couette’s flow. Numerical results and a discussion are presented for this unsuccessful test case. It is believed that other LB models may have the same problem in addressing the simulation of multiphase flows with variable density ratios.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Metric-Based Validation Process to Assess the Realism of Synthetic Power Grids

Public power system test cases that are of high quality benefit the power systems research community with expanded resources for testing, demonstrating, and cross-validating new innovations. Building synthetic grid models for this purpose is a relatively new problem, for which a challenge is to show that created cases are sufficiently realistic. This paper puts forth a validation process based on a set of metrics observed from actual power system cases. These metrics follow the structure, proportions, and parameters of key power system elements, which can be used in assessing and validating the quality of synthetic power grids. Though wide diversity exists in the characteristics of power systems, the paper focuses on an initial set of common quantitative metrics to capture the distribution of typical values from real power systems. The process is applied to two new public test cases, which are shown to meet the criteria specified in the metrics of this paper.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Comparison of Building Energy Modeling Programs: Building Loads

This technical report presented the methodologies, processes, and results of comparing three Building Energy Modeling Programs (BEMPs) for load calculations: EnergyPlus, DeST and DOE-2.1E. This joint effort, between Lawrence Berkeley National Laboratory, USA and Tsinghua University, China, was part of research projects under the US-China Clean Energy Research Center on Building Energy Efficiency (CERC-BEE). Energy Foundation, an industrial partner of CERC-BEE, was the co-sponsor of this study work. It is widely known that large discrepancies in simulation results can exist between different BEMPs. The result is a lack of confidence in building simulation amongst many users and stakeholders. In the fields of building energy code development and energy labeling programs where building simulation plays a key role, there are also confusing and misleading claims that some BEMPs are better than others. In order to address these problems, it is essential to identify and understand differences between widely-used BEMPs, and the impact of these differences on load simulation results, by detailed comparisons of these BEMPs from source code to results. The primary goal of this work was to research methods and processes that would allow a thorough scientific comparison of the BEMPs. The secondary goal was to provide a list of strengths and weaknesses for each BEMP, based on in-depth understandings of their modeling capabilities, mathematical algorithms, advantages and limitations. This is to guide the use of BEMPs in the design and retrofit of buildings, especially to support China’s building energy standard development and energy labeling program. The research findings could also serve as a good reference to improve the modeling capabilities and applications of the three BEMPs. The methodologies, processes, and analyses employed in the comparison work could also be used to compare other programs. The load calculation method of each program was analyzed and compared to identify the differences in solution algorithms, modeling assumptions and simplifications. Identifying inputs of each program and their default values or algorithms for load simulation was a critical step. These tend to be overlooked by users, but can lead to large discrepancies in simulation results. As weather data was an important input, weather file formats and weather variables used by each program were summarized. Some common mistakes in the weather data conversion process were discussed. ASHRAE Standard 140-2007 tests were carried out to test the fundamental modeling capabilities of the load calculations of the three BEMPs, where inputs for each test case were strictly defined and specified. The tests indicated that the cooling and heating load results of the three BEMPs fell mostly within the range of spread of results from other programs. Based on ASHRAE 140-2007 test results, the finer differences between DeST and EnergyPlus were further analyzed by designing and conducting additional tests. Potential key influencing factors (such as internal gains, air infiltration, convection coefficients of windows and opaque surfaces) were added one at a time to a simple base case with an analytical solution, to compare their relative impacts on load calculation results. Finally, special tests were designed and conducted aiming to ascertain the potential limitations of each program to perform accurate load calculations. The heat balance module was tested for both single and double zone cases. Furthermore, cooling and heating load calculations were compared between the three programs by varying the heat transfer between adjacent zones, the occupancy of the building, and the air-conditioning schedule.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗