Search NASA⌕ Search

SEARCH · Search NASA

Results for “test configuration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Hydrodynamic Analysis and Optimization of Aquantis Marine Turbine: Cooperative Research and Development (Final Report)

The primary aim of this proposal is to improve the accurate prediction of hydrodynamic performance and dynamic load responses of the AQ10 floating axial-flow tidal turbine with a tri-cat mooring configuration. The validation of reduced-order modeling approaches with high-fidelity model will be implemented. Additionally, the frequency response domain, Response Amplitude Floating Wind (RAFT) toolbox plus an optimizer expanded for marine hydrokinetic turbines under the Submarine Hydrokinetic And Riverine Kilo-megawatt. Systems (SHARKS) program will be used for designing and exploring different key design parameters (platform dimension, mooring layout and its parameters) of next marine hydrokinetic (MHK) turbine generation.

16 TIDAL AND WAVE POWER↗

Field Validation of MVA Technology for Offshore CCS: Novel Ultra-High-Resolution 3D Marine Seismic Technology (P-Cable) (Final Report)

The objectives of the proposed study were to deploy and validate a specific monitoring technology, high-resolution 3D marine seismic (HR3D), appropriate for large-demonstration and commercial-scale offshore CCS sites. The project accomplished successful acquisition two HR3D seismic surveys. The first HR3D dataset was over the offshore injection site of the Tomakomai, Japan integrated pilot CCS project, which at the time of survey acquisition was actively injecting CO 2 . The first survey also represented a successful international collaboration between the DOE NETL program and Japan’s national CCS program and was the first successful acquisition and use of HR3D over an active CO 2 injection site (Meckel, Feng et al. 2019). The Tomakomai HR3D survey successfully tested a novel 4-streamer HR3D system array in which, for the first time, no cross-cable (aka “P-Cable”) was utilized and only four GeoEel streamers were used instead of the standard 12-streamer configuration. Consequently, this was not, strictly speaking, a deployment of the “P-Cable” system of (Planke and Berndt 2004) but rather a modified version, thereof, and it is the first known demonstration of the modified system configuration. One very positive outcome from the Japanese collaboration earlier in the project was the ability to learn from the Japanese how they used tail buoys with GPS to determine the position of the seismic source and receivers in time and space. Based on that experience, GCCC designed and built six GPS receivers that could be used to position the streamer receivers and the seismic source via tail buoys. A fundamental advance that was made on the original design, was the ability to directly power the tail buoy GPS units and transfer data through the streamers (i.e., vs. the batteries used at Tomakomai). The bulkiness of the GPS batteries caused drag and episodic surging of the buoys, which affected data quality by lifting up the tail end of the streamers so the receivers were not at the same depth. The units were tested onshore for accuracy and functionality, and the design was subsequently and successfully tested in marine acquisition mode during the SLP survey acquisition. The marine acquisition test and survey satisfied Subtasks 2.2.2, Novel Positioning Technology Selection and Subtask 2.2.3, Novel Positioning Technology Deployment. Results of the novel positioning technology selection (Subtask 2.2.2) were considered successful and will be incorporated in future HR3D seismic acquisition projects to reduce costs, improve deployment safety at sea, and integrate both seismic and data recording via a single data transfer through the streamers to the recording system. The project also established a permitting process through NETL NEPA compliance, which included an Environmental Assessment in a marine setting and is required for conducting these types of surveys using Federal funding. The permitting process charted a “boilerplate,” which can allow future surveys related to other funded projects to move forward more expeditiously. Future improvements that could be considered are more robust seals on the GPS module and stronger materials (especially joints) on tail buoy fabrication. These would increase fixed costs, but would be advisable and probably more economic long-term if multiple HR3D surveys are planned. Project Accomplishments include: • Pre-survey Sensitivity Study • Marine geochemistry methods and data analysis • Successful HR3D seismic dataset acquired @ Tomakomai active CO 2 injection marine site • Developed advanced seismic processing techniques • No NRMS anomalies detected in overburden; Demonstration of containment • Repeatability study • Second survey collected @ San Luis Pass, TX • 4D application using positioning techniques developed in the project for monitoring were successful

3D seismic GPS positioning↗

Intermediate Scale Test Platform Conceptual Design and Hybrid Resin Performance Evaluation Recommendations

Recent laboratory evaluations demonstrated that further testing of alternative hybrid resins is warranted for their potential use as part of the 200 West Area (200W) pump-and-treat (P&T) remedy. 200W P&T has been treating technetium (Tc) since 2012 and uranium (U) since 2015 via two separate ion exchange (IX) treatment units: a single treatment train (i.e., a three-vessel system) for the removal of uranium utilizing a gel strong base anion (SBA) exchange resin, Dowex 21K; and two parallel treatment trains for the removal technetium using a gel SBA resin, Purolite® A532E. While these resins have been removing these contaminants effectively, new hybrid resins can provide additional benefits of further optimizing the IX treatment unit capacities and addressing additional treatment needs (e.g., Cr(VI)) by removing multiple contaminants simultaneously and/or through specific design configurations. Some of these resins also demonstrated some level of removal for I-129 which would be significant for expansion of the P&T into the 200 East Area. This document provides design recommendations for an intermediate scale test platform (ISTP) to evaluate alternative hybrid IX resin performance under conditions approaching field scale and using 200W P&T process groundwater. Results from the ISTP will provide the technical basis required to inform alternative IX resin selection in future 200W P&T facility operations where the treatment of multiple contaminants of concern may be required.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effect of cell compression on the performance and the structure of proton exchange membrane water electrolyzer (PEMWE) assembly

Here, in the field of water electrolysis, the proton exchange membrane water electrolyzer (PEMWE) is currently the most advanced technology for producing hydrogen without emitting CO 2 . Although PEMWE plants are already in operation, further research is needed to improve cell efficiency and reduce the use of rare materials, such as iridium oxide catalysts for the oxygen evolution reaction (OER). One of the main causes of performance loss in PEMWE is the relatively low electric conductivity of the porous transport layer (PTL) and of the anode catalyst layer, which results in ohmic losses and low catalyst utilization during high current density operation. The objective of this study is to investigate how optimization of the PTL and electrode interface can increase the cell performance. To this end, we tested different cell assemblies using fibrous and sintered PTLs, decreasing membrane thickness, reducing iridium loading, and inserting a microporous layer to increase contact surface area. Electrochemical characterization of each cell configuration was systematically performed at various compression levels as the pressure is a crucial parameter influencing the electrode/PTL contact area. In parallel, X-ray microcomputed tomography (micro-CT) was employed to investigate the effects of cell hydration and compression on the structure of PEMWE components. This study combining electrochemistry and micro-CT imaging presents how optimizing the electrode/PTL contact surface area, minimizes ohmic losses, and enables PEMWE operation with low iridium loading at high current densities.

Catalyst - PTL interface↗

Machine-learning-assisted deciphering of microstructural effects on ionic transport in composite materials: A case study of Li 7 La 3 Zr 2 O 12 -LiCoO 2

The effective diffusivity of ionic species in multiphase materials is critical for the design and function of composite materials for electrochemical energy storage. In practice, effective diffusivity depends sensitively not only on the intrinsic diffusivities of constituting materials but also on their topological arrangement; nevertheless, these coupled contributions are oversimplified in most analytical models. Here, we combine atomistically informed mesoscale modeling and machine learning (ML) analysis to unravel how such features affect effective diffusivity in two-phase composites. Using the Li 7 La 3 Zr 2 O 12 -LiCoO 2 composite solid-state battery cathode as a model system, we compute effective diffusivity for 600 distinct dense polycrystalline microstructures with different topological configurations of grains, grain boundaries, and heterointerfaces. We verify that in addition to atomic-scale variabilities, microstructural feature diversity can significantly impact effective transport properties. Across the ensemble of test microstructures, this often results in bimodal distributions of effective diffusivity that encompass two qualitatively distinct operating mechanisms, which we identify via flux analysis. An ML approach reveals that the most critical determining factors for effective diffusivity are the connectivity of bulk phases and their heterointerfaces. The role of ionic mobility at the heterointerfaces is also discussed. These insights highlight the combined importance of microstructure and interface engineering in tuning the transport properties of ionic species in composite materials. In conclusion, our framework can also be extended for understanding generic microstructure-property relationships in other complex multiphase materials.

25 ENERGY STORAGE↗

Distribution of centrality measures on undirected random networks via the cavity method

The Katz centrality of a node in a complex network is a measure of the node’s importance as far as the flow of information across the network is concerned. For ensembles of locally tree-like undirected random graphs, this observable is a random variable. Its full probability distribution is of interest but difficult to handle analytically because of its “global” character and its definition in terms of a matrix inverse. Leveraging a fast Gaussian Belief Propagation-Cavity algorithm to solve linear systems on tree-like structures, we show that i) the Katz centrality of a single instance can be computed recursively in a very fast way, and ii) the probability P ( K ) that a random node in the ensemble of undirected random graphs has centrality K satisfies a set of recursive distributional equations, which can be analytically characterized and efficiently solved using a population dynamics algorithm. We test our solution on ensembles of Erdős-Rényi and Scale Free networks in the locally tree-like regime, with excellent agreement. The analytical distribution of centrality for the configuration model conditioned on the degree of each node can be employed as a benchmark to identify nodes of empirical networks with over- and underexpressed centrality relative to a null baseline. We also provide an approximate formula based on a rank- 1 projection that works well if the network is not too sparse, and we argue that an extension of our method could be efficiently extended to tackle analytical distributions of other centrality measures such as PageRank for directed networks in a transparent and user-friendly way.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ab initio investigation of a hypersonic double cone experiment

This article presents a direct molecular simulation (DMS) of a reactive Mach 8.2 oxygen flow over a double cone geometry. The free stream conditions and article configuration generate a flow with thermal and chemical nonequilibrium, which are common attributes of hypersonic flight. This scenario was first studied experimentally at Calspan University of Buffalo Research Center’s test facility. DMS is a particle method that uses quantum mechanically derived interaction potentials to simulate molecular collisions within a flow field. Since these interaction potentials are the only modeling inputs used in the simulation, all flow features can solely be attributed to the ab initio potential energy surfaces. Hence, providing a comparison of a hypersonic ground test and numerical data anchored to quantum mechanics. The fundamental nature of DMS is leveraged to investigate molecular level mechanisms prevalent in the flow, and comparisons with lower fidelity simulations are presented to highlight the role of these first principles calculations as benchmark solutions.

Science & Technology - Other Topics↗

CVEVOLVE

CVEvolve is an agentic AI system for autonomous algorithm discovery for scientific data processing. It creates workflows where large language model agents freely set up and configure development environments and evaluation harnesses, develop and improve data processing algorithms with designed exploration-exploitation balancing mechanisms, log history and findings in a structured database, and run holdout testing to ensure algorithm generalizability. CVEvolve offers a zero-code interface and does not require users to provide structured data and evaluation scripts.

Cherukara, MatthewJoseph [Argonne National Laborat↗

Chemical detection system with at least one electronic nose

A system for predicting one or more analytes based on outputs from thin film gas sensors is provided. The system may comprise an electronic nose (e-nose). The e-nose may comprise the gas sensors and a first processor. The system may further comprise a second processor. The second processor may be configured to receive the output from each of the gas sensors, evaluate a prediction accuracy using an evaluation parameter of each of a plurality of models which are trained and tested and select a model from among the plurality of models to deploy based on a comparison of the evaluation parameter for each of the plurality of models and use the same. The second processor may also receive, an output of each of the gas sensors caused by unknown one or more analytes; and predict, using the deployed model, the one or more analytes that causes the output.

Ivanov, Ilia N.↗

A recirculation system for concentrating CO 2 electrolyzer products

Electrochemical carbon dioxide reduction represents a promising path to utilize CO 2 as a feedstock for generating valuable products such as fuels and chemicals. Faradaic efficiencies near 100% have been achieved for certain CO 2 reduction products such as CO, but the electrolyzer outlet streams usually contain large fractions of unreacted CO 2 , dropping the product concentrations below 1% in many cases. The system disclosed here recycles the unreacted CO 2 together with the products and flows them back into the CO 2 reduction reactor, enabling much higher CO 2 conversion rates without dropping the gas flow rate. However, simple recirculation is shown to accumulate significant amounts of hydrogen, impeding effective CO 2 reduction. In this looped system, an electrochemical H 2 pump is placed in series with the CO 2 reactor, which effectively removes all the H 2 from the recycled gas stream, increasing the concentrations of carbon-containing products. Here, the system was initially tested with a CO-generating catalyst and CO concentrations above 70% were achieved in the recycled gas stream, compared to a maximum CO concentration of 8% in single-pass configuration. Results with a CO 2 reactor targeting ethylene as the main product show that ethylene concentrations of at least 10% can be achieved, which is roughly 20 times higher compared to a single-pass system.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

NCERC-CL TREAT Free Field Characterization Foil Reaction Rate Results

This report summarizes the analysis and preliminary MCNP reaction rate modeling of free field characterization measurements performed in the Transient Reaction Test Facility (TREAT) at Idaho National Laboratory (INL) between 12/18/2023 and 2/22/2024. A series of seven irradiations were performed using the Big-BUSTER (Broad Use Specimen Transient Experiment Rig) core configuration. Foil sets including 19.5% LEU-Zr alloy wire, S, Au, Fe, Ni, Co, Ti, and Zr were deployed in each irradiation. Identical foil sets were supplied to Los Alamos National Laboratory (LANL), Lawrence Livermore National Laboratory (LLNL), and INL. All foils were supplied by INL. Additional details on the experiment can be found in [2]. The foil sets were shipped to the National Criticality Experiments Research Center Counting Laboratory (NCERC-CL) branch at LANL (NCERC-CL NISC) and were received on 3/25/2024. Additional details on receipt and counting are reported in [3]. All reactor dosimetry measurements were performed in adherence to the ASTM standards applicable to reactor dosimetry. Measured reaction rates from Au, Co, Fe, Ni, and Ti are reported. Select reaction rate ratios and simulated reaction rates and ratios are discussed. Reaction rates for all measured reaction products were modeled with MCNP 6.3.1 and a TREAT input deck supplied by Edward Lum. Neutron emission estimates calculated using the measured and simulated reaction rates show excellent agreement between the three fast-threshold n-p reactions with the percent differences being < 9% between the three reactions. The capture reactions had poorer, but still reasonable, agreement with < 20% percent differences between the neutron emission estimates of the three capture reactions. The percent difference between the fast-threshold and capture reactions is ∼ 100% for each reaction. This supports the TREAT model is not accurately modeling the neutron spectrum and additional measurements are required to characterize TREAT and match measurements to simulation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Recent Progress of JT-60SA Project toward Plasma Operation

Superconducting tokamak JT-60SA plays an essential role in fusion research and development by supporting and complementing ITER project, providing directions to the DEMO design activity and fostering next generation scientists and engineers. Since the incident of the Equilibrium Field coil #1 during the Integrated Commissioning (IC) in March 2021, both EU and JA Implementing agencies (IAs) have examined how to ensure safety operation of JT-60SA by mitigating the risk of possible discharge occurrence inside the cryostat. Based on the experience of the Global Paschen tests, the IAs have established a strategy of risk mitigation measures, which is a combination of (i) reinforcement of insulation, (ii) avoiding unnecessary voltage application to the coil systems and (iii) immediate de-energization of the coils when deteriorated vacuum condition is detected. Thanks to the considerable efforts of the Integrated Project Team (IPT) members, the IC restarted in May 2023. After the confirmation of superconducting state of coil systems (TF, EF and CS), the coil energization test and the plasma operation (OP-1) starts. The first plasma was successfully achieved on 23 October 2023 with a limited value of applied voltage and current to the coils. The plasma configuration control will be also confirmed with low plasma current and low auxiliary heating power conditions. Based on the IO-F4E-QST collaboration, activities of JT-60SA have been shared with the IO and provided an important lesson learned for ITER assembly and commissioning, and will provide an outstanding contribution to fusion research at large. After OP-1, Maintenance & Enhancement phase 1 (M/E-1) starts from January 2024, in which in-vessel components are installed, and heating system and diagnostic system are extensively upgraded to allow high power heating experiment planned in OP-2. In order to make the best use of JT-60SA, newly organized JT-60SA experiment team will refine the research plan in the future high heating power operation phase.

Broader Approach activities↗

In-orbit operation of Resolve Filter Wheel and modulated X-ray source

The Resolve soft X-ray spectrometer is a high spectral resolution microcalorimeter spectrometer for the X-ray Imaging and Spectroscopy Mission. In the beam of Resolve, there is a filter wheel containing X-ray filters. In the beam, there is also an active calibration source, the modulated X-ray source (MXS), which can provide pulsed X-rays to facilitate gain calibration. The filter wheel consists of six filter positions. Two open positions, one 55 Fe source to aid in spectrometer characterization during the commissioning phase, and three transmission filters: a neutral density filter, an optical blocking filter, and a beryllium filter. The X-ray intensity, pulse period, and pulse separation of an MXS are highly configurable. Furthermore, the switch-on time is synchronized with the spacecraft’s internal clock to give accurate start and end times of the pulses. One of the issues raised during ground testing was the susceptibility of an MXS at high voltage to ambient light. Although measures were taken to mitigate the light leak, the efficacy of those measures must be verified in orbit. Along with an overview of issues raised during ground testing, we will discuss the calibration source and the filter performance in-flight and compare with the transmission curves present in the Resolve calibration database.

X-ray Imaging and Spectroscopy Mission/Resolve↗

Evaluating mesoscale model predictions of diurnal speedup events in the Altamont Pass Wind Resource Area of California

Mesoscale model predictions of wind, turbulence, and wind energy capacity factors are evaluated in the Altamont Pass Wind Resource Area of California (APWRA), where the diurnal regional sea breeze and associated terrain-driven speedup flows drive wind energy production during the summer months. Results from the Weather Research and Forecasting model version 4.4 using a novel three-dimensional planetary boundary layer (3D PBL) scheme, which treats both vertical and horizontal turbulent mixing, are compared to those using a well-established one-dimensional (1D) scheme that treats only vertical turbulent mixing. Each configuration is evaluated over a nearly 3-month-long period during the Hill Flow Study, and due to the recurring nature of the observed speedup flows, diurnal composite averaging is used to capture robust trends in model performance. Both model configurations showed similar overall skill. The general timing and direction of the speedup flows is captured, but their magnitude is overestimated within a typical wind turbine rotor layer. Both also fail to capture a persistent observed near-surface jet-like flow, likely due to the limited grid resolution that is typical of mesoscale models. However, the 3D PBL configuration shows several minor improvements over the 1D PBL configuration, including improved wind speed and turbulence kinetic energy profiles during the accelerating phase of the speedup events, as well as reduced positive wind speed bias at surface stations across the APWRA region. Using a mesoscale wind farm parameterization, modeled capacity factors are also compared to monthly data reported to the US Energy Information Administration (EIA) during the study period. Although the monthly trend in the data is captured, both model configurations overestimate capacity factors by roughly 7 %–11 %. Through model evaluation, this study provides confidence in the 3D PBL scheme for wind energy applications in complex terrain and provides guidance for future testing.

17 WIND ENERGY↗

Flashback Measurements in Hydrogen Enriched Low Swirl Flames Using High Speed OH-PLIF

The fundamentals of stabilized flame dynamics and flashback events in a premixed low swirl burner (LSB) configuration are visualized experimentally using nanosecond (ns)-based high-speed hydroxyl radical planar laser-induced fluorescence (OH-PLIF). Swirlers with two different turning angles, 〖26〗^o and 〖33〗^o and three different center-body hole diameters, 1.08, 1.12 and 1.16 mm with measured swirl numbers varying from 0.43 to 0.49 are tested in this study at atmospheric temperature and pressure inlet conditions. An increase in flashback propensity is observed with increasing ϕ, X_(H_2 ) and decreasing V via detailed investigation of flame lift-off length (L) above the burner rim. Flashback ϕ (ϕ_FB) investigations show an expected linearly increasing trend with decreasing X_(H_2 ) and increasing V for each swirler studied and the results agree well with detailed L investigations in a stable flame configuration. ϕ_FB studies for different swirlers show an increase in flashback resistance with the increase in center-body hole diameter and swirl angle. Spatiotemporally resolved kHz-rate OH-PLIF is a promising technique to observe rapidly occurring flashback events and it can be applied for turbulence-chemistry interaction model validation.

Parajuli, Pradeep↗

Accurate and rapid acoustic damage characterization in complex structures using sparse sensor networks and deep learning models

Damage diagnosis in critical components is essential for ensuring the safety and reliability of operations across industries, spanning manufacturing, aerospace, and energy. Traditional acoustic nondestructive testing methods primarily focus on detecting defects through the direct scattering of single-mode incident waves from the damage, which limit their applicability to simple structures and small inspection areas. Our earlier research demonstrated that machine learning algorithms combined with sparse sensor networks can identify critical defect signatures even from multiply scattered, multi-mode acoustic signals, indicating the potential for improved defect inspection in complex, real-world structures. In this work, we demonstrate the successful implementation of this approach in a fixed sensor configuration to rapidly and accurately detect simulated defects in a geometrically complex, real-world structure, a brake rotor hub. Three different types of defects were physically simulated on the surface of the hub, and the collected data were used to train an autoencoder-based deep learning model. Two models were tested, one using single measurements and the other using multiple measurements taking advantage of the spatial distribution of the sensor network. After training, the multi-measurement model achieved 100 % accuracy in identifying, classifying, and locating unseen, unique damages. This work illustrates the potential of the proposed method for a wide range of industrial applications.

36 MATERIALS SCIENCE↗

Mean-Field Ring Polymer Rates Using a Population Dividing Surface

Mean-field Ring Polymer Molecular Dynamics (MF-RPMD) offers a computationally efficient method for the simulation of reaction rates in multi-level systems. Previous work has established that, to model a nonadiabatic state-to-state reaction accurately, the dividing surface must be chosen to explicitly sample kinked ring polymer configurations where at least one bead is in a different electronic state than the others. Building on this, we introduce a population difference coordinate and a kink-constrained dividing surface, and we test the accuracy of the resulting mean-field rate theory on a series of bilinear coupling model systems. Here, we demonstrate that this new MF-RPMD rate approach is efficient to implement and quantitatively accurate for models over a wide range of driving forces, coupling strengths, and temperatures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗