Search NASA⌕ Search

SEARCH · Search NASA

Results for “test system test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

DEVELOPMENT OF A COMPUTATIONAL MULTIPHASE FLOW MODEL FOR FISCHER TROPSCH SYNTHESIS IN A SLURRY BUBBLE COLUMN REACTOR

The Hybrid Energy Systems Testing (HYTEST) Laboratory is being established at the Idaho National Laboratory to develop and test hybrid energy systems with the principal objective to safeguard U.S. Energy Security by reducing dependence on foreign petroleum. A central component of the HYTEST is the slurry bubble column reactor (SBCR) in which the gas-to-liquid reactions will be performed to synthesize transportation fuels using the Fischer Tropsch (FT) process. SBCRs are cylindrical vessels in which gaseous reactants (for example, synthesis gas or syngas) is sparged into a slurry of liquid reaction products and finely dispersed catalyst particles. The catalyst particles are suspended in the slurry by the rising gas bubbles and serve to promote the chemical reaction that converts syngas to a spectrum of longer chain hydrocarbon products, which can be upgraded to gasoline, diesel or jet fuel. These SBCRs operate in the churn-turbulent flow regime which is characterized by complex hydrodynamics, coupled with reacting flow chemistry and heat transfer, that effect reactor performance. The purpose of this work is to develop a computational multiphase fluid dynamic (CMFD) model to aid in understanding the physico-chemical processes occurring in the SBCR. Our team is developing a robust methodology to couple reaction kinetics and mass transfer into a four-field model (consisting of the bulk liquid, small bubbles, large bubbles and solid catalyst particles) that includes twelve species: (1) CO reactant, (2) H2 reactant, (3) hydrocarbon product, and (4) H2O product in small bubbles, large bubbles, and the bulk fluid. Properties of the hydrocarbon product were specified by vapor liquid equilibrium calculations. The absorption and kinetic models, specifically changes in species concentrations, have been incorporated into the mass continuity equation. The reaction rate is determined based on the macrokinetic model for a cobalt catalyst developed by Yates and Satterfield [1]. The model includes heat generation due to the exothermic chemical reaction, as well as heat removal from a constant temperature heat exchanger. Results of the CMFD simulations (similar to those shown in Figure 1) will be presented.

10 SYNTHETIC FUELS↗

Mechanical Testing of Hydrided Fuel Cladding

The U.S. Department of Energy Office of Nuclear Energy, Office of Fuel Cycle Technology established the Used Fuel Disposition Campaign (UFDC) to conduct research and development activities related to storage, transportation, and disposal of used nuclear fuel (UNF) and high-level radioactive waste. Within the UFDC, the storage and transportation task has been created to address issues of extended storage and transportation. One gap in knowledge identified as high priority by UFDC includes hydrogen effects in zirconium alloy cladding and reorientation of cladding hydrides. During reactor operations, hydrogen is generated from the oxidation of the surface of zirconium alloy materials in the coolant of light water reactors can be absorbed into the cladding and form zirconium hydrides. At high temperatures and hoop stresses, these normally circumferential oriented hydrides in high burnup UNF (HB-UNF) may reorient in the radial direction and affect the mechanical properties of the cladding. Understanding these changes in mechanical properties will aid in analyzing how UNF will perform during storage and transportation. Separate effects testing to measure the mechanical properties of un-hydrided, pre-hydrided, and irradiated HB-UNF is currently underway at Pacific Northwest National Laboratory (PNNL). In order to measure these mechanical properties, staff at PNNL are employing tensile, compression, and burst testing. Systems have been developed to pre-hydride cladding and reorient cladding hydrides. The development of these systems and the testing methods are described herein.

Cladding, Zirconium, Hydrides, Mechanical Testing↗

Monitoring system for testing the radiation hardness of a KINTEX-7 FPGA

A much more efficient Ring Imaging Cherenkov sub-detector system will be rebuilt in the second long shutdown of Large Hadron Collider for the LHCb experiment. Radiation-hard electronic components together with Commercial Off-The-Shelf ones will be used in the new Cherenkov photon detection system architecture. An irradiation program was foreseen to determine the radiation tolerance for the new electronic devices, including a Field Programmable Gate Array from KINTEX-7 family of XILINX. An automated test bench for online monitoring of the XC7K70T KINTEX-7 device operation in radiation conditions was designed and implemented by the LHCb Romanian group.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Closure Report for Corrective Action Unit 563: Septic Systems, Nevada Test Site, Nevada

Corrective Action Unit (CAU) 563 is identified in the Federal Facility Agreement and Consent Order (FFACO) as “Septic Systems” and consists of the following four Corrective Action Sites (CASs), located in Areas 3 and 12 of the Nevada Test Site: · CAS 03-04-02, Area 3 Subdock Septic Tank · CAS 03-59-05, Area 3 Subdock Cesspool · CAS 12-59-01, Drilling/Welding Shop Septic Tanks · CAS 12-60-01, Drilling/Welding Shop Outfalls Closure activities were conducted from September to November 2009 in accordance with the FFACO (1996, as amended February 2008) and the Corrective Action Plan for CAU 563. The corrective action alternatives included No Further Action and Clean Closure.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Data and Insights for the KRUSTY Nuclear-Powered Tests

This document, and the associated files, describe all of the data from the KRUSTY warm criticals and the KRUSTY nuclear system test. The warm criticals were a group of tests where fission power heated the core and the feedback response was studied. There were 3 experiments, the 15-cent run (which was a true “free run”), followed by 30-cent and 60-cent runs, where reactivity was added to heat the core to higher temperatures. The nuclear system test (often referred to as the full-run or the final-run), engaged the power conversion system and evaluated system performance. These experiments are described in a pair of NUCLEAR TECHNOLOGY papers, which includes plots of the data that this document-set includes. Note that a lot of information in this document is based on my interpretation and could be wrong, but I’ve included it to potentially save some people a lot of time and headaches by trying to figure out which instrumentation to believe, but beware treating anything I say as fact. I’ve also included several post-irradiation photos, to show some thermocouple locations and indicate possible changes in emissivity and/or geometry (although no changes in geometry were indicated).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Lead Coolant Test Facility Systems Design, Thermal Hydraulic Analysis and Cost Estimate

The Idaho National Laboratory prepared a preliminary technical and functional requirements (T&FR), thermal hydraulic design and cost estimate for a lead coolant test facility. The purpose of this small scale facility is to simulate lead coolant fast reactor (LFR) coolant flow in an open lattice geometry core using seven electrical rods and liquid lead or lead-bismuth eutectic coolant. Based on review of current world lead or lead-bismuth test facilities and research needs listed in the Generation IV Roadmap, five broad areas of requirements were identified as listed: (1) Develop and Demonstrate Feasibility of Submerged Heat Exchanger; (2) Develop and Demonstrate Open-lattice Flow in Electrically Heated Core; (3) Develop and Demonstrate Chemistry Control; (4) Demonstrate Safe Operation; and (5) Provision for Future Testing. This paper discusses the preliminary design of systems, thermal hydraulic analysis, and simplified cost estimate. The facility thermal hydraulic design is based on the maximum simulated core power using seven electrical heater rods of 420 kW; average linear heat generation rate of 300 W/cm. The core inlet temperature for liquid lead or Pb/Bi eutectic is 4200 C. The design includes approximately seventy-five data measurements such as pressure, temperature, and flow rates. The preliminary estimated cost of construction of the facility is $3.7M (in 2006 $). It is also estimated that the facility will require two years to be constructed and ready for operation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SRPPF Aqueous Recovery System Sorbent Testing

This study details preliminary testing of 7 inorganic sorbents for the solidification of the surrogate SRPPF aqueous recovery system liquid excess material of 4M sodium nitrate. Sorbents were subject to various mixing methods to incorporate sodium nitrate solution including static, rotating, and in situ paddle mixing. Paddle mixing was found to be the most effective mixing technique, while simple static tests were also successful, though only for some of the sorbents. Setting tests were performed to ensure that the sorbent sequestered the liquid without release through a conical paint filter. Recommended set times ranged from near immediate to 7 days. The set mixtures were investigated further using ultra-centrifugal liquid release testing, thermogravimetric analysis, and visual microscopy to understand the mechanism by which the sorbent sequestered the liquid. Most sorbents seem to incorporate liquid by sorbing it onto and into the sorbent particles, while Drierite ® , anhydrous calcium sulfate, created a crystal structure that bound the surrogate liquid. Overall, four sorbents are recommended for continued testing: Aquaset II, Aquaset IIG, Drierite ® , and Spill-X-A.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization of the Emissions and Crystalline Silica Content of Airborne Dust Generated from Grinding Natural and Engineered Stones

Abstract In this study, we systematically characterized the airborne dust generated from grinding engineered and natural stone products using a laboratory testing system designed and operated to collect representative respirable dust samples. Four stone samples tested included two engineered stones consisting of crystalline silica in a polyester resin matrix (formulations differed with Stones A having up to 90wt% crystalline silica and Stone B up to 50wt% crystalline silica), an engineered stone consisting of recycled glass in a cement matrix (Stone C), and a granite. Aerosol samples were collected by respirable dust samplers, total dust samplers, and a Micro-Orifice Uniform Deposit Impactor. Aerosol samples were analyzed by gravimetric analysis and x-ray diffraction to determine dust generation rates, crystalline silica generation rates, and crystalline silica content. Additionally, bulk dust settled on the floor of the testing system was analyzed for crystalline silica content. Real-time particle size distributions were measured using an Aerodynamic Particle Sizer. All stone types generated similar trimodal lognormal number-weighted particle size distributions during grinding with the most prominent mode at an aerodynamic diameter of about 2.0-2.3 μm, suggesting dust formation from grinding different stones is similar. Bulk dust from Stone C contained no crystalline silica. Bulk dust from Stone A, Stone B, and granite contained 60, 23, and 30wt% crystalline silica, respectively. In Stones A and B, the cristobalite form of crystalline silica was more plentiful than the quartz form. Only the quartz form was detected in granite. The bulk dust, respirable dust, and total dust for each stone had comparable amounts of crystalline silica, suggesting that crystalline silica content in the bulk dust could be representative of that in respirable dust generated during grinding. Granite generated more dust per unit volume of material removed than the engineered stones, which all had similar normalized dust generation rates. Stone A had the highest normalized generation rates of crystalline silica, followed by granite, Stone B, and Stone C (no crystalline silica), which likely leads to the same trend of respirable crystalline silica (RCS) exposure when working with these different stones. Manufacturing and adoption of engineered stone products with formulations such as Stone B or Stone C could potentially lower or eliminate RCS exposure risks. Combining all the effects of dust generation rate, size-dependent silica content, and respirable fraction, the highest normalized generation rate of RCS consistently occurs at 3.2-5.6 µm for all the stones containing crystalline silica. Therefore, removing particles in this size range near the generation sources should be prioritized when developing engineering control measures.

Public, Environmental & Occupational Health↗

Mimicking Martian dust: An in-vacuum dust deposition system for testing the ultraviolet sensors on the Curiosity rover

We have designed and developed an in-vacuum dust deposition system specifically conceived to simulate and study the effect of accumulation of Martian dust on the electronic instruments of scientific planetary exploration missions. We have used this device to characterize the dust effect on the UV sensor of the Rover Environmental Monitoring Station in the Mars science Laboratory mission of NASA in similar conditions to those found on Mars surface. The UV sensor includes six photodiodes for measuring the radiation in all UV wavelengths (direct incidence and reflected); it is placed on the body of Curiosity rover and it is severely affected by the dust deposited on it. Our experimental setup can help to estimate the duration of reliable reading of this instrument during operation. We have used an analogous of the Martian dust in chemical composition (magnetic species), color, and density, which has been characterized by X-ray spectroscopy. To ensure a Brownian motion of the dust during its fall and a homogeneous coverage on the instrumentation, the operating conditions of the vacuum vessel, determined by partial pressures and temperature, have to be modified to account for the different gravities of Mars with respect to Earth. We propose that our designed device and operational protocol can be of interest to test optoelectronic instrumentation affected by the opacity of dust, as can be the degradation of UV photodiodes in planetary exploration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ISD3: a particokinetic model for predicting the combined effects of particle sedimentation, diffusion and dissolution on cellular dosimetry for in vitro systems

The development of particokinetic models describing the delivery of insoluble or poorly soluble nanoparticles to cells in liquid cell culture systems has improved the basis for dose-response analysis, hazard ranking from high-throughput systems, and now allows for translation of exposures across in vitro and in vivo test systems. Complimentary particokinetic models that address processes controlling delivery of both particles and released ions to cells, and the influence of particle size changes from dissolution on particle delivery for cell-culture systems would help advance our understanding of the role of particles ion dosimetry on cellular toxicology. We developed ISD 3 , an extension of our previously published model for insoluble particles, by deriving a specific formulation of the Population Balance Equation for soluble particles. ISD3 describes the time, concentration and particle size dependent dissolution of particles, their delivery to cells, and the delivery and uptake of ions to cells in in vitro liquid test systems. The model is modular, and can be adapted by application of any empirical model of dissolution, alternative approaches to calculating sedimentation rates, and cellular uptake or treatment of boundary conditions. We apply the model to calculate the particle and ion dosimetry of nanosilver and silver ions in vitro after calibration of two empirical models, one for particle dissolution and one for ion uptake. The results demonstrate utility and accuracy of the ISD 3 framework for dosimetry in these systems. Total media ion concentration, particle concentration and total cell-associated silver time-courses were well described by the model, across 2 concentrations of 20 and 110 nm particles. ISD 3 was calibrated to dissolution data for 20 nm particles as a function of serum protein concentration, but successfully described the media and cell dosimetry time-course for both particles at all concentrations and time points. We also report the finding that protein content in media has effects both on the initial rate of dissolution and the resulting near-steady state ion concentration in solution.

59 BASIC BIOLOGICAL SCIENCES↗

Washington Clean Energy Fund: Energy Storage System Performance Test Plans and Data Requirements

This report documents the test plans, including detailed duty cycles, used in evaluating the technical performance of five energy storage systems (ESSs) sponsored by the Washington State Clean Energy Fund (CEF). These ESSs were installed at three participating utilities’ (Avista, Snohomish Public Utility District or SnoPUD, and Puget Sound Energy or PSE) designated sites. Under each test plan, a number of baseline and use case tests are defined. This report documents the test plan for each utility, including duty cycles, data and performance reporting requirements. Baseline tests defined in this report mainly focus on determining an initial or reference performance for each ESS, which may be compared with the performance at any later time to assess the state of health of the ESS. Parameter values of a given ESS obtained from baseline tests are applied for different modeling purposes and use case tests. The stored energy capacity test is the first test conducted in the baseline test program, which generates data to calculate round trip efficiency (RTE). The response time and ramp rate tests provide the time required for an ESS to change from zero to full charging/discharging rate and hence the ramp rate, which is important in understanding ESS performance for applications calling for fast response. Internal resistance testing of ESS cells is also conducted in conjunction with the response time and ramp rate tests. Finally, the baseline tests include frequency regulation (FR) and peak shaving (PS) tests based on real-world duty cycles. Upon completion of the baseline tests, use case tests are conducted at each of the storage sites with duty cycles developed to meet the site-specific criteria and conditions. The use cases are grouped according to their intended target benefits within the electric infrastructure topology (e.g., transmission versus distribution). Although an ESS may be located on the low-voltage side of a substation that provides power to a distribution feeder, a use case that addresses bulk power services could still be provided and would be grouped under the transmission or bulk-power benefits. Use cases for ESS applications deep into the distribution circuit would be categorized under the distribution system cases.

25 ENERGY STORAGE↗

Beyond Price-Taker: Multiscale Optimization of Wind and Battery Integrated Energy Systems

Integrating renewable energy into the electric grid is challenging due to the intermittency and variability of wind and other non-dispatchable resources. Integrated energy systems (IESs) combine multiple energy technologies (e.g., fossil, nuclear, renewables, storage) to reduce costs and improve flexibility and reliability. However, standard techno-economic analysis (TEA) methods often overestimate the benefits of IESs because they fail to account for energy market adjustments. This paper systematically studies the limitations of the prevailing price-taker assumption for TEA and optimization of hybrid energy systems. As an illustrative case study, we retrofit an existing wind farm in the RTS-GMLC test system (which loosely mimics the Southwest U.S.) with battery energy storage to form an IES. We show that the standard price-taker model overestimates the electricity revenue and the net present value (NPV) of the IES up to 178% and 30.4%, respectively, compared to our more rigorous multiscale optimization. These differences arise because introducing storage creates a more flexible resource that impacts the larger wholesale electricity market. Moreover, this work highlights the impact of the IES has on the market via various strategic bidding, and underscores the importance of moving beyond price-taker for optimal storage sizing and TEA of IESs. We conclude by discussing opportunities to generalize the proposed framework to other IESs, and highlight emerging research questions regarding the complex interactions between IESs and markets.

25 ENERGY STORAGE↗

Corrective Action Decision Document for Corrective Action Unit 562: Waste Systems Nevada Test Site, Nevada, Revision 0

This Corrective Action Decision Document (CADD) presents information supporting the selection of corrective action alternatives (CAAs) leading to the closure of Corrective Action Unit (CAU) 562, Waste Systems, in Areas 2, 23, and 25 of the Nevada Test Site, Nevada. This complies with the requirements of the Federal Facility Agreement and Consent Order (FFACO) that was agreed to by the State of Nevada; U.S. Department of Energy (DOE), Environmental Management; U.S. Department of Defense; and DOE, Legacy Management. Corrective Action Unit 562 comprises the following corrective action sites (CASs): • 02-26-11, Lead Shot • 02-44-02, Paint Spills and French Drain • 02-59-01, Septic System • 02-60-01, Concrete Drain • 02-60-02, French Drain • 02-60-03, Steam Cleaning Drain • 02-60-04, French Drain • 02-60-05, French Drain • 02-60-06, French Drain • 02-60-07, French Drain • 23-60-01, Mud Trap Drain and Outfall • 23-99-06, Grease Trap • 25-60-04, Building 3123 Outfalls The purpose of this CADD is to identify and provide the rationale for the recommendation of CAAs for the 13 CASs within CAU 562. Corrective action investigation (CAI) activities were performed from July 27, 2009, through May 12, 2010, as set forth in the CAU 562 Corrective Action Investigation Plan. The purpose of the CAI was to fulfill the following data needs as defined during the data quality objective (DQO) process: • Determine whether COCs are present. • If COCs are present, determine their nature and extent. • Provide sufficient information and data to complete appropriate corrective actions. A data quality assessment (DQA) performed on the CAU 562 data demonstrated the quality and acceptability of the data for use in fulfilling the DQO data needs. Analytes detected during the CAI were evaluated against appropriate final action levels (FALs) to identify the COCs for each CAS. The results of the CAI identified COCs at 10 of the 13 CASs in CAU 562, and thus corrective action is required. Assessment of the data generated from investigation activities conducted at CAU 562 is shown in Table ES-1. Based on the evaluation of analytical data from the CAI, review of future and current operations at the 13 CASs, and the detailed and comparative analysis of the potential CAAs, the following corrective actions are recommended for CAU 562. • No further action is the preferred corrective action for CASs 02-60-01, 02-60-06, and 02-60-07. • Clean closure is the preferred corrective action for CASs 02-26-11, 02-44-02, 02-59-01, 02-60-02, 02-60-03, 02-60-04, 02-60-05, 23-60-01, 23-99-06, and 25-60-04. The preferred CAAs were evaluated on technical merit focusing on performance, reliability, feasibility, safety, and cost. The alternatives were judged to meet all requirements for the technical components evaluated. The alternatives meet all applicable federal and state regulations for closure of the site and will reduce potential exposures to contaminated media to acceptable levels. The DOE, National Nuclear Security Administration Nevada Site Office provides the following recommendations: • No further corrective action is required at CASs 02-60-01, 02-60-06, and 02-60-07. • Clean closure is recommended for the remaining 10 CASs in CAU 562. • A Corrective Action Plan will be submitted to the Nevada Division of Environmental Protection that contains a detailed description of the proposed actions that will be taken to implement the selected corrective actions.

54 ENVIRONMENTAL SCIENCES↗

Situated Usability Testing for Security Systems

While usability testing is well established, assessing the usability of security software, tools, or methods deserves more careful consideration. It has been argued that dealing with security has become too difficult for individuals or organizations to manage effectively or to use conveniently. As difficult as it is for system administrators and developers to deal with, security is even more challenging for casual users. Indeed, it is much too easy for casual/home users to configure the security of their systems in non-optimal ways that leave their systems inadvertently insecure. This is exacerbated by the fact that casual users are focused on matters other than security, and likely would prefer not even to think about security. This brief report argues that when security and/or privacy are part of the equation, traditional methods for usability testing should be re-considered. The purpose of this brief report is to argue for and outline a method associated with a new approach to usability testing for examining usable security issues.

99 GENERAL AND MISCELLANEOUS↗

Impact of Detailed Parameter Modeling of Open-Cycle Gas Turbines on Production Cost Simulation: Preprint

Flexible resources are increasingly important as variable renewable energy deployment in the power system increases. Although many systems are transitioning away from fossil fuels, open-cycle gas turbines are likely to play an important balancing role for some time, thus requiring accurate modeling of their operational parameters. This paper explores the impact of detailed representation of three operational parameters - start- up costs, run-up rates, and forced outage rates - in the production cost model of a system as it adopts higher levels of wind and solar. Using PLEXOS simulations of the NREL-118 bus test system, the study examines how more detailed parameter modeling affects outcomes such as the number of start-ups and shutdowns, ramping and total generation costs for open-cycle gas turbines, as renewable energy levels increase. The results suggest the value of detailed parameter modeling and continued research on combustion turbines' ability to provide flexibility.

economic dispatch↗

System for testing properties of a network

A method for identifying properties of a downhole electromagnetic network in a downhole tool sting, including the step of providing an electromagnetic path intermediate a first location and a second location on the electromagnetic network. The method further includes the step of providing a receiver at the second location. The receiver includes a known reference. The analog signal includes a set amplitude, a set range of frequencies, and a set rate of change between the frequencies. The method further includes the steps of sending the analog signal, and passively modifying the signal. The analog signal is sent from the first location through the electromagnetic path, and the signal is modified by the properties of the electromagnetic path. The method further includes the step of receiving a modified signal at the second location and comparing the known reference to the modified signal.

02 PETROLEUM↗

Connected Lighting Systems Efficiency Study: PoE Cable Energy Losses, Part 2

DOE published a report in November 2017 (herein referred to as “Part 1”) summarizing the results of an exploratory study investigating power losses in Ethernet cables used between PoE switches and luminaires in PoE connected lighting systems. Testing was conducted at the Pacific Northwest National Laboratory (PNNL) Connected Lighting Test Bed (CLTB) in September 2017. The results were analyzed to explore the impact of cable selection on PoE lighting system energy efficiency, as well as the effectiveness of guidelines published by the American National Standards Institute (ANSI) C137 Lighting Systems Committee in 2017. The guidance offered in ANSI C137.3-2017 was found to be effective in limiting cable energy losses to 5% in PoE lighting applications, provided that the average cable length on a project does not exceed 50 m. This Part 2 report summarizes the results of a continued investigation of the power losses in Ethernet cables used between PoE switches and luminaires in PoE connected lighting systems. Testing was conducted at the PNNL CLTB in July-August 2018. A test setup comprising a PoE switch, a set of luminaires, and a reference meter was again used to test multiple cable models of varying design. The results were analyzed to explore the impact of cable selection and installation practices (e.g., cable bending, cable bundling, and installation in conduit) on PoE lighting system energy efficiency, as well as the effectiveness of the ANSI C137.3 guidelines. Notably, three cables—two of which were shielded—were previously excluded from the Part 1 study due to compatibility issues. All three cables were included in this Part 2 study, along with a fourth model cable introduced in Part 2. In addition, whereas no patch cords were used in Part 1, patch cords were used in some Part 2 testing. The ANSI C137.3 guidance was again shown to effectively limit power losses to less than 5% in the cables tested (varying in AWG, Category, shielding, fire rating, and manufacturer), and AWG again proved to be the most important cable design variable for energy performance, as expected. However, these findings should not be construed as being representative of all cable models and installation practices. For example, energy losses would be greater when cables are connected to patch cords, bundled in conduit, and loaded with powered devices (PDs) approaching 100 W input power. The other key finding was that with 44 W luminaires as PDs and room ambient temperatures below 30°C, cable energy losses were not substantially increased by cable bending or bundling in uninsulated conduit. However, environments with higher ambient temperatures will have greater energy losses due to increased conductor DCR. In addition, product selection and installation practices will have increased importance as PDs approaching 100 W input power—conveyed by a single Ethernet cable—are introduced following publication of the forthcoming Institute of Electrical and Electronics Engineers (IEEE) Standard 802.3bt. The report also provides recommendations and next steps, which include plans for additional PoE cable energy losses testing with higher-power PDs to more fully explore the potential of PoE lighting systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

In Vitro Thrombogenicity Testing of Biomaterials in a Dynamic Flow Loop: Effects of Length and Quantity of Test Samples

Abstract The results of in vitro dynamic thrombogenicity testing of biomaterials and medical devices can be significantly impacted by test conditions. To develop and standardize a robust dynamic in vitro thrombogenicity tool, the key test parameters need to be appropriately evaluated and optimized. We used a flow loop test system previously developed in our laboratory to investigate the effects of sample length and the number of samples per test loop on the thrombogenicity results. Porcine blood heparinized to a donor-specific target concentration was recirculated at room temperature through polyvinyl chloride (PVC) tubing loops containing test materials for 1 h at 200 mL/min. Four test materials (polytetrafluoroethylene (PTFE), latex, PVC, and silicone) with various thrombotic potentials in two sample lengths (12 and 18 cm) were examined. For the 12-cm long materials, two different test configurations (one and two samples per loop) were compared. Thrombogenicity was assessed through percent thrombus surface coverage, thrombus weight, and platelet count reduction in the blood. The test system was able to effectively differentiate the thrombogenicity profile of the materials (latex > silicone > PVC ≥ PTFE) at all test configurations. Increasing test sample length by 50% did not significantly impact the test results as both 12 and 18 cm sample lengths were shown to equally differentiate thrombotic potentials between the materials. The addition of a second test sample to each loop did not increase the test sensitivity and may produce confounding results, and thus a single test sample per loop is recommended.

Engineering↗