Search NASA⌕ Search

SEARCH · Search NASA

Results for “thermal loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Methodological guidelines on concrete degradation based on predictive models and the release of MOSAIC for industry use

In light-water reactors (LWRs), the concrete biological shield (CBS) designates the concrete structure directly facing the reactor pressure vessel (RPV). The primary function of the CBS is to protect equipment and personnel from the neutron and gamma radiation exiting the RPV. Most CBSs in operation in the United States also provide structural support to the RPV. Based on a long-term structural analysis, the structural integrity of the CBS to transfer the in-service passive load to the foundation, dynamic loading during an earthquake, and thermal loading during a loss-of-coolant accident (LOCA) must be maintained. Based on test reactor data for accelerated conditions, the mechanical properties of irradiated concrete are affected when exposed to neutron fluence higher than ≈ 10 19 n.cm -2 (E > 0.1 MeV). At 80 years of operation, the fluence estimates at the surface of the CBS range between 1×10 19 and 7×10 19 n.cm -2 (E > 0.1 MeV): the fluence value depends mostly on the design. Although fluence attenuates through the CBS by virtue of the shielding properties of concrete, about 5% to 10% of the CBS wall depth is affected by high fluence. The main degradation mechanism is the so-called radiation-induced volumetric expansion (RIVE) caused by the amorphization of aggregate-forming minerals. RIVE causes large deformation of up to 18% in pure quartz, and it also reduces the structural properties of concrete. The structural effects of long-term exposure to fast neutron irradiation in LWRs was studied in the report entitled “Assessment of the Effect of the Irradiation-Induced Degradation on the In-Service Structural Performance of the Concrete Biological Shields” (M3LW-23OR0403013). This report illustrates that (1) irradiation-induced damage expands further than the region subject to a cumulative fluence of 10 19 n.cm -2 (E > 0.1 MeV) to reach the steel reinforcement location, and (2) the irradiation-induced damage region shows no substantial residual bearing capacity and should not be accounted for in the integrity assessment of the CBS.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Stress analysis under component relative interference fit

Finite-element computer program enables analysis of distortions and stresses occurring in components having relative interference. Program restricts itself to simple elements and axisymmetric loading situations. External inertial and thermal loads may be applied in addition to forces arising from interference conditions.

Taylor, C. M.↗

A new boundary element formulation for two- and three-dimensional thermoelasticity using particular integrals

New two- and three-dimensional BEM formulations are developed for steady-state and transient uncoupled thermoelasticity. These new procedures differ from previous work in that additional surface of volume integration is not required to incorporate thermal loads in the analysis. Instead, thermal body forces are introduced in the BEM system via particular integrals. The present formulation is implemented in a general-purpose multiregion system, and examples are presented to demonstrate the accuracy and versatility of the method.

Henry, Donald P., Jr.↗

Aerothermal Performance Constraints for Small Radius Leading Edges Operating at Hypervelocity

Small radius leading edges and nosetips were used to minimize wave drag in early hypervelocity vehicle concepts until further analysis demonstrated that extreme aerothermodynamic heating blunted the available thermal protection system materials. Recent studies indicate that ultra-high temperature composite (UHTC) materials are shape stable at temperatures approaching 3033 K and will be available for use as sharp leading edge components in the near future. Steady-state aerothermal performance constraints for UHTC components are presented in this paper to identify their non-ablating operational capability at altitudes from sea level to 90 km. An integrated design tool was developed to estimate these constraints. The tool couples aerothermodynamic heating with material response using commercial finite element analysis software and is capable of both steady-state and transient analysis. Performance during entry is analyzed by transient thermal analysis along the trajectory. The thermal load condition from the transient thermal analysis is used to estimate thermal stress. Applying the tool to UHTC materials shows that steady-state, non-ablating operation of a HfB2/SiC(A-7) (A-7) component is possible at velocities approaching Earth's circular orbital velocity of 7.9 km/s at altitudes approaching 70 km.

Kolodziej, Paul↗

Finite Element Modeling of Thermal Cycling Induced Microcracking in Carbon/Epoxy Triaxial Braided Composites

The microcrack distribution and mass change in PR520/T700s and 3502/T700s carbon/epoxy braided composites exposed to thermal cycling was evaluated experimentally. Acoustic emission was utilized to record the crack initiation and propagation under cyclic thermal loading between -55 C and 120 C. Transverse microcrack morphology was investigated using X-ray Computed Tomography. Different performance of two kinds of composites was discovered and analyzed. Based on the observations of microcrack formation, a meso-mechanical finite element model was developed to obtain the resultant mechanical properties. The simulation results exhibited a decrease in strength and stiffness with increasing crack density. Strength and stiffness reduction versus crack densities in different orientations were compared. The changes of global mechanical behavior in both axial and transverse loading conditions were studied. Keywords: Thermal cycles; Microcrack; Finite Element Model; Braided Composite

Zhang, Chao↗

Average Heat Flux Measurements in a Gaseous Detonation-Based Rocket Engine

Rotating detonation rocket engines (RDREs) offer benefits over traditional deflagrative engines, including increased engine performance, compact combustion and negligible detrimental thermoacoustic instabilities due to mode-locking. Realizing the benefits of a detonation-based propulsion system will be accompanied by increased thermal loads due to a combination of heat release at elevated pressure and temperature, as well as compact heat release due to detonation. Managing these heat loads necessitates the development of thermal management strategies. As a first step towards establishing the requirements for detonation-based engine thermal management strategies, this work develops an additively manufactured (AM) water-based, axially resolved calorimeter for integration in an existing 76.8 mm outer diameter (OD) RDRE to measure average chamber heat flux. In particular, the calorimetry outer body provides average heat flux data via circumferential channels at nine axial stations to axially resolve the heat flux distribution on the chamber outer wall. The average heat flux is found to be 5 − 12 MW/m 2 for a straight annulus and 6 − 18 MW/m 2 for a constricted annular configuration which exhibited maximum heat flux at the throat. A difference in heat flux scaling is observed near the detonation region compared to the downstream flow expansion section in the constricted geometry. By quantifying the axial distribution of heat flux, this work seeks to support the development of thermal management systems for long duration firing of detonation-based devices.

Matthew A Maybee↗

Average Heat Flux Measurements in a Gaseous Detonation-Based Rocket Engine

Rotating detonation rocket engines (RDREs) offer benefits over traditional deflagrative engines, including increased engine performance, compact combustion and negligible detrimental thermoacoustic instabilities due to mode-locking. Realizing the benefits of a detonation-based propulsion system will be accompanied by increased thermal loads due to a combination of heat release at elevated pressure and temperature, as well as compact heat release due to detonation. Managing these heat loads necessitates the development of thermal management strategies. As a first step towards establishing the requirements for detonation-based engine thermal management strategies, this work develops an additively manufactured (AM) water-based, axially resolved calorimeter for integration in an existing 76.8 mm outer diameter (OD) RDRE to measure average chamber heat flux. In particular, the calorimetry outer body provides average heat flux data via circumferential channels at nine axial stations to axially resolve the heat flux distribution on the chamber outer wall. The average heat flux is found to be 5 − 12 MW/m 2 for a straight annulus and 6 − 18 MW/m 2 for a constricted annular configuration which exhibited maximum heat flux at the throat. A difference in heat flux scaling is observed near the detonation region compared to the downstream flow expansion section in the constricted geometry. By quantifying the axial distribution of heat flux, this work seeks to support the development of thermal management systems for long duration firing of detonation-based devices.

Matthew A Maybee↗

The Best of Both Worlds: Combined Thermal and Battery Storage for Widespread Building Decarbonization

To meet 2050 decarbonization targets, widespread building electrification is a critical complement to clean power generation. Behind-the-meter storage (BTMS) (e.g., battery electric energy storage [EES] and thermal energy storage [TES]) integrated with buildings or building end uses to store and supply energy at optimal times can minimize burdens associated with operation, planning, and upgrades to the electrical grid sometimes triggered by building electrification. Such BTMS systems can serve the dual purpose of providing enhanced resilience at the building and grid level, and support the deployment of renewable generation needed for wide-scale decarbonization. While TES can cost-effectively shed and shift thermal loads, it cannot generally backup or shift non-thermal building end uses. EES, by contrast, is more expensive, but applicable to all end uses (i.e., thermal and electrical loads). Combined together, these storage systems can be traded off against one another to perform optimally in meeting demand flexibility, decarbonization goals, and energy resilience of the buildings at a lower total system cost. This paper proposes a framework to define BTMS benefits, provides four illustrative electrification scenarios using TES and EES, and discusses the combined TES/EES benefits with building energy modeling results. The paper also highlights potential barriers to adoption of BTMS and a path forward.

buildings↗

Final Report: Assessment of Combined Heat and Power Premium Power Applications in California

This report analyzes the current economic and environmental performance of combined heat and power (CHP) systems in power interruption intolerant commercial facilities. Through a series of three case studies, key trade-offs are analyzed with regard to the provision of black-out ridethrough capability with the CHP systems and the resutling ability to avoid the need for at least some diesel backup generator capacity located at the case study sites. Each of the selected sites currently have a CHP or combined heating, cooling, and power (CCHP) system in addition to diesel backup generators. In all cases the CHP/CCHP system have a small fraction of the electrical capacity of the diesel generators. Although none of the selected sites currently have the ability to run the CHP systems as emergency backup power, all could be retrofitted to provide this blackout ride-through capability, and new CHP systems can be installed with this capability. The following three sites/systems were used for this analysis: (1) Sierra Nevada Brewery - Using 1MW of installed Molten Carbonate Fuel Cells operating on a combination of digestor gas (from the beer brewing process) and natural gas, this facility can produce electricty and heat for the brewery and attached bottling plant. The major thermal load on-site is to keep the brewing tanks at appropriate temperatures. (2) NetApp Data Center - Using 1.125 MW of Hess Microgen natural gas fired reciprocating engine-generators, with exhaust gas and jacket water heat recovery attached to over 300 tons of of adsorption chillers, this combined cooling and power system provides electricity and cooling to a data center with a 1,200 kW peak electrical load. (3) Kaiser Permanente Hayward Hospital - With 180kW of Tecogen natural gas fired reciprocating engine-generators this CHP system generates steam for space heating, and hot water for a city hospital. For all sites, similar assumptions are made about the economic and technological constraints of the power generation system. Using the Distributed Energy Resource Customer Adoption Model (DER-CAM) developed at the Lawrence Berkeley National Laboratory, we model three representative scenarios and find the optimal operation scheduling, yearly energy cost, and energy technology investments for each scenario below: Scenario 1 - Diesel generators and CHP/CCHP equipment as installed in the current facility. Scenario 1 represents a baseline forced investment in currently installed energy equipment. Scenario 2 - Existing CHP equipment installed with blackout ride-through capability to replace approximately the same capacity of diesel generators. In Scenario 2 the cost of the replaced diesel units is saved, however additional capital cost for the controls and switchgear for blackout ride-through capability is necessary. Scenario 3 - Fully optimized site analysis, allowing DER-CAM to specify the number of diesel and CHP/CCHP units (with blackout ride-through capability) that should be installed ignoring any constraints on backup generation. Scenario 3 allows DER-CAM to optimize scheduling and number of generation units from the currently available technologies at a particular site. The results of this analysis, using real data to model the optimal schedulding of hypothetical and actual CHP systems for a brewery, data center, and hospital, lead to some interesting conclusions. First, facilities with high heating loads will typically prove to be the most appropriate for CHP installation from a purely economic standpoint. Second, absorption/adsorption cooling systems may only be economically feasible if the technology for these chillers can increase above current best system efficiency. At a coefficient of performance (COP) of 0.8, for instance, an adsorption chiller paired with a natural gas generator with waste heat recovery at a facility with large cooling loads, like a data center, will cost no less on a yearly basis than purchasing electricity and natural gas directly from a utility. Third, at marginal additional cost, if the reliability of CHP systems proves to be at least as high as diesel generators (which we expect to be the case), the CHP system could replace the diesel generator at little or no additional cost. This is true if the thermal to electric (relative) load of those facilities was already high enough to economically justify a CHP system. Last, in terms of greenhouse gas emissions, the modeled CHP and CCHP systems provide some degree of decreased emissions relative to systems with less CHP installed. The emission reduction can be up to 10% in the optimized case (Scenario 3) in the application with the highest relative thermal load, in this case the hospital. Although these results should be qualified because they are only based on the three case studies, the general results and lessons learned are expected to be applicable across a broad range of potential and existing CCHP systems.

25 ENERGY STORAGE↗

Thermal and structural analysis of a new WEST reciprocating probe head with Titanium-Zirconium-Molybdenum armour material

The Tore Supra tokamak was transformed into an X-point divertor fusion device in the frame of the WEST (W-for tungsten-Environment in Steady-state Tokamak) project, launched in support of the ITER tungsten divertor strategy. WEST began operation in 2017. A new reciprocating probe head, equipped with a Titanium-Zirconium-Molybdenum (TZM) heat shield, was recently built and operated on WEST during the C9 Campaign in early 2024. TZM was chosen as armour material for its very good mechanical properties between 700 °C and 1400 °C. This material was already extensively used for probe heads and other plasma facing components on the Alcator C-Mod tokamak. Here, this paper presents the design of the new WEST probe head. It is equipped with tungsten filaments that can be heated to emit electrons and provide a direct measurement of the plasma potential in the scrape-off layer, and it is also equipped with a pair of Langmuir probes. The probe plunges vertically into the plasma, reaches its maximum dive depth, then returns to its protected resting position in about 0.25 s. Thermal loads are calculated using as input the thermal properties of TZM and radial profiles of the heat flux measured in the past by other reciprocating probes, and scaled upwards to the expected heat loads in the WEST scrape-off layer. An analytical estimation of Electromagnetic (EM) loads will also be presented, as well as a thermal and structural analysis of the probe for 15 cycles at maximum plunge depth. The probe is observed by an infrared camera. Comparisons between the heat flux deduced by the Langmuir probe and the infrared radiance of the probe housing during plasma exposure are finally presented.

Diagnostic↗

Program for Computing Albedo

Simple Thermal Environment Model (STEM) is a FORTRAN-based computer program that provides engineering estimates of top-of-atmosphere albedo and outgoing long-wave radiation (OLR) for use in analyzing thermal loads on spacecraft near Earth. The thermal environment of a spacecraft is represented in STEM as consisting of direct solar radiation; short-wave radiation reflected by the atmosphere of the Earth, as characterized in terms of the albedo of the Earth; and OLR emitted by the atmosphere of the Earth. STEM can also address effects of heat loads internal to a spacecraft. Novel features of STEM include (1) the use of Earth albedo and OLR information based on time series of measurements by Earth Radiation Budget Experiment satellites in orbit; (2) the ability to address thermal time constants of spacecraft systems by use of albedo and OLR values representing averages over a range of averaging times; and (3) the ability to address effects, on albedo and OLR values, of satellite orbital inclination, the angle between the plane of a spacecraft orbit and the line between the centers of the Earth and Sun, the solar zenith angle, and latitude.

Justus, Carl G.↗

University of Missouri Research Reactor (MURR) Design Demonstration Element End Fitting Structural Rigidity Analysis

The primary objective of this work is to assess the extent to which the stiffness (measured by means of maximum displacement) of the end fittings in the DDE contributes to the stiffness of the entire element, and how it compares to the equivalent stiffness of the end fittings in the LEU element. Structural analysis of both the LEU element and the DDE were performed using COMSOL 5.3a finite element software. Supporting combs are used on the leading and trailing edges of fuel plates for both the LEU element and the DDE. Therefore, simulations with and without combs are performed as two bounding boundary conditions on the leading edge of the fuel plates. Three types of loads are analyzed in this work: the hydraulic load due to the channel flow disparity-induced pressure differential, the thermal load due to the thermal expansion of the fuel plates, and a point load equal in magnitude to the LEU element’s weight.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Simulation Framework for Analyzing the Impact of Stochastic Occupant Behaviors on Demand Flexibility in Typical Commercial Buildings

As one of the primary users of the electric grid, buildings and building equipment, including heating, ventilation, and air conditioning (HVAC) systems, can be leveraged to provide the flexible demand needed to balance the grid. Typical strategies to achieve demand flexibility are to reduce electricity use during peak or critical periods by shutting down equipment or relaxing system setpoints, which will inevitably impact the occupants’ comfort. When occupants feel uncomfortable, they may take actions to regain their comfort, and some of those actions (such as turning on a personal fan) may have a negative impact on meeting the demand response goal. Therefore, it is important to incorporate occupant behaviors into the assessment ofthe building demand flexibility potential. In this study, a simulation framework that includes simulation of zone thermal loads, an HVAC system, and occupant behaviors, was developed to investigate the impact of occupant behaviors on demand flexibility. A case study was conducted using a small office model from the U.S. Department of Energy (DOE) Commercial Prototype Building Models to simulate the building envelope and zone loads. An agent-based occupant thermal behavior model was adapted to forecast occupants’ thermal comfort and their resulting thermal behaviors. An artificial neural network (ANN) based airflow model trained from a computational fluid dynamics (CFD) model of the zone was adopted to better predict the ambient environment of each occupant. An air-source heat pump simulation model that was calibrated from a real two-stage air-source heat pump system was used as the HVAC system. A typical load shedding event during peak hours was studied. Repeated simulations were conducted to capture the stochastic effects of occupant behaviors. The interplay between the demand flexibility, occupant comfort and behavior were analyzed by evaluating key performance indicators, including the energy use, occupant discomfort duration, and occupant behavior duration during the peak period. The results suggest that this framework can be used to analyze typical commercial buildings and their HVAC systems in terms ofdemand flexibility potential under the impact of occupant behaviors.

Chen, Zhelun↗

In-Situ Measurement of Power Loss for Crystalline Silicon Modules Undergoing Thermal Cycling and Mechanical Loading Stress Testing

An in-situ method is proposed for monitoring and estimating the power degradation of mc-Si photovoltaic (PV) modules undergoing thermo-mechanical degradation tests that primarily manifest through cell cracking, such as mechanical load tests, thermal cycling and humidity freeze tests. The method is based on in-situ measurement of the module’s dark current-voltage (I-V) characteristic curve during the stress test, as well as initial and final module flash testing on a Sun simulator. The method uses superposition of the dark I-V curve with final flash test module short-circuit current to account for shunt and junction recombination losses, as well as series resistance estimation from the in-situ measured dark I-Vs and final flash test measurements. The method is developed based on mc-Si standard modules undergoing several stages of thermo-mechanical stress testing and degradation, for which we investigate the impact of the degradation on the modules light I-V curve parameters, and equivalent solar cell model parameters. Experimental validation of the method on the modules tested shows good agreement between the in-situ estimated power degradation and the flash test measured power loss of the modules, of up to 4.31 % error (RMSE), as the modules experience primarily junction defect recombination and increased series resistance losses. However, the application of the method will be limited for modules experiencing extensive photo-current degradation or delamination, which are not well reflected in the dark I-V characteristic of the PV module.

14 SOLAR ENERGY↗

Comparison Evaluations of VRF and RTU Systems Performance on Flexible Research Platform

The energy performance of a variable refrigerant flow (VRF) system was evaluated using an occupancy-emulated research building in the southeastern region of the United States. Full- and part-load performance of the VRF system in heating and cooling seasons was compared with a conventional rooftop unit (RTU) variable-air-volume system with electric resistance heating. During both the heating and cooling seasons, full- and part-load conditions (i.e., 100%, 75%, and 50% thermal loads) were maintained alternately for 2 to 3 days each, and the energy use, thermal conditions, and coefficient of performance (COP) for the RTU and VRF system were measured. During the cooling season, the VRF system had an average COP of 4.2, 3.9, and 3.7 compared with 3.1, 3.0, and 2.5 for the RTU system under 100%, 75%, and 50% load conditions and resulted in estimated energy savings of 30%, 37%, and 47%, respectively. Finally, during the heating season, the VRF system had an average COP ranging from 1.2 to 2.0, substantially higher than the COPs of the RTU system, and resulted in estimated energy savings of 51%, 47%, and 27% under the three load conditions, respectively.

42 ENGINEERING↗

Numerical simulation of the nonlinear response of composite plates under combined thermal and acoustic loading

A time-domain study of the random response of a laminated plate subjected to combined acoustic and thermal loads is carried out. The features of this problem also include given uniform static inplane forces. The formulation takes into consideration a possible initial imperfection in the flatness of the plate. High decibel sound pressure levels along with high thermal gradients across thickness drive the plate response into nonlinear regimes. This calls for the analysis to use von Karman large deflection strain-displacement relationships. A finite element model that combines the von Karman strains with the first-order shear deformation plate theory is developed. The development of the analytical model can accommodate an anisotropic composite laminate built up of uniformly thick layers of orthotropic, linearly elastic laminae. The global system of finite element equations is then reduced to a modal system of equations. Numerical simulation using a single-step algorithm in the time-domain is then carried out to solve for the modal coordinates. Nonlinear algebraic equations within each time-step are solved by the Newton-Raphson method. The random gaussian filtered white noise load is generated using Monte Carlo simulation. The acoustic pressure distribution over the plate is capable of accounting for a grazing incidence wavefront. Numerical results are presented to study a variety of cases.

Mei, Chuh↗

Thermal behavior of a titanium honeycomb-core sandwich panel

Finite element thermal stress analysis was performed on a rectangular titanium honecomb-core sandwich panel which is subjected to thermal load with a temperature gradient across its depth. The distributions of normal stresses in the face sheets and the face-sheet/sandwich-core interfacial shear stresses are presented. The thermal buckling of the heated face sheet was analyzed by assuming the face sheet to be resting on an elastic foundation representing the sandwich core. Thermal buckling curves and thermal buckling load surface are presented for setting the limit for temperature gradient across the panel depth.

Ko, William L.↗

NREL Works to Increase Electric Vehicle Efficiency Through Enhanced Thermal Management [Fact Sheet]

Researchers at NREL are providing new insight into how heating and cooling systems affect the distance that electric vehicles can travel on a single charge. Electric vehicle range can be reduced by as much as 68% per charge because of climate-control demands. NREL engineers are investigating opportunities to change this dynamic and increase driving range by improving vehicle thermal management. NREL experts are collaborating with automotive industry partners to investigate promising thermal management technologies and strategies, including zone-based cabin temperature controls, advanced heating and air conditioning controls, seat-based climate controls, vehicle thermal preconditioning, and thermal load reduction technologies.

30 DIRECT ENERGY CONVERSION↗