Search NASA⌕ Search

SEARCH · Search NASA

Results for “time of flight”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Simultaneous measurement of organic scintillator response to carbon and proton recoils

Organic scintillators are widely used for neutron detection in both basic nuclear physics and applications. While the proton light yield of organic scintillators has been extensively studied, measurements of the light yield from neutron interactions with carbon nuclei are scarce. Demonstrate a new approach for the simultaneous measurement of the proton and carbon light yield of organic scintillators. Provide new carbon light yield data for the EJ-309 liquid and EJ-204 plastic organic scintillators. A 33-MeV 2 H + beam from the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory was impinged upon a 3-mm-thick Be target to produce a high-flux, broad-spectrum neutron beam. The double time-of-flight technique was extended to simultaneously measure the proton and carbon light yields of the organic scintillators, wherein the light output associated with the recoil particle was determined using np and nC elastic scattering kinematics. The proton and carbon light yield relations of the EJ-309 liquid and EJ-204 plastic organic scintillators were measured over a recoil energy range of approximately 0.3 to 1 MeV and 2 to 5 MeV, respectively, for EJ-309, and 0.2 to 0.5 MeV and 1 to 4 MeV, respectively, for EJ-204. Furthermore, these data provide new insight into the ionization quenching effect in organic scintillators and key input for simulation of the response of organic scintillators for both basic science and a broad range of applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron diffraction: a primer

Because of the neutron’s special properties, neutron diffraction may be considered one of the most powerful techniques for structure determination of crystalline and related matter. Neutrons can be released from nuclear fission, from spallation processes, and also from low-energy nuclear reactions, and they can then be used in powder, time-of-flight, texture, single crystal, and other techniques, all of which are perfectly suited to clarify crystal and magnetic structures. With high neutron flux and sufficient brilliance, neutron diffraction also excels for diffuse scattering, for in situ and operando studies as well as for high-pressure experiments of today’s materials. For these, the wave-like neutron’s infinite advantage (isotope specific, magnetic) is crucial to answering important scientific questions, for example, on the structure and dynamics of light atoms in energy conversion and storage materials, magnetic matter, or protein structures. In this primer, we summarize the current state of neutron diffraction (and how it came to be), but also look at recent advances and new ideas, e.g., the design of new instruments, and what follows from that.

36 MATERIALS SCIENCE↗

High temperature neutron diffraction investigation of U 3 Si 2

The U-Si system is actively undergoing studies due to its promise as a component of an accident tolerant nuclear fuel. In this work, the crystal structure of the U 3 Si 2 compound in the U-Si system was investigated as a function of temperature from room temperature to 1298 K for a sample of approximately 42.02 at.% Si composition and 1373 K for a sample with approximately 42.10 at.% Si using high temperature time-of-flight neutron diffraction on the High-Pressure Preferred Orientation (HIPPO) diffractometer at Los Alamos Neutron Science Center (LANSCE). The simultaneous Rietveld refinement of five histograms from the five HIPPO detector backs (40°, 60°, 90°, 120°, and 145°) provided datasets for the lattice parameters, anisotropic atomic displacement parameters, and atomic positions as a function of temperature. To explore the possibility of a homogeneity range, two sample compositions were analyzed, a 40.02 at.% Si (near stoichiometric) and a potentially hyperstoichiometric (40.10 at.% Si) sample. While minor differences in the anisotropic atomic displacement parameters between the two samples were observed, over the entire investigated temperature range no additional phases were found indicative of a single phase sample and the ability of the U 3 Si 2 compound to accommodate nonstoichiometry, suggesting that the U 3 Si 2 compound is not a line compound confirming previous determinations. However, the differences observed in the average coefficient of linear thermal expansion identified between the two compositions warrant future investigation.

36 MATERIALS SCIENCE↗

In-house synthesized poly(ether ether ketone) ionenes. II. ToF-SIMS spectra in the negative ion mode

Time-of-flight secondary ion mass spectrometry (ToF-SIMS) was used to analyze poly(ether ether ketone) (PEEK) based membranes. PEEK membranes have been shown to be effective in the separation of CO 2 from flue gases (post-combustion technique). The PEEK membranes were synthesized using novel aromatic ether-ketone linkages inspired by PEEK with polymeric backbone bistriflimide [Tf2N]− counterions. One of the keys to advancing this technology is developing membranes that are selective and permeable toward CO 2 , in which PEEK based membranes have been shown to be. Furthermore, the compatibility between various water lean solvents also needs to be investigated. Surface analytical techniques such as x-ray photoelectron spectroscopy and ToF-SIMS are useful for investigating chemical changes between membranes. Herein, we present ToF-SIMS data obtained in the negative ion mode for four different PEEK membranes designed for use in CO 2 capture systems. Positive ion mode spectra are reported in Paper I.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In-house synthesized poly(ether ether ketone) ionenes. I. ToF-SIMS spectra in the positive ion mode

Static time-of-flight secondary ion mass spectrometry (ToF-SIMS) was performed for acquiring the high-resolution surface spectra of four types of synthesized imidazolium ionene membranes. These novel membranes have aromatic ether–ketone–ether linkages inspired by poly(ether ether ketone) (PEEK). The PEEK-ionenes synthesized for this study have imidazolium cations placed in the polymeric backbone with bistriflimide [Tf 2 N]- counterions. The attention given to synthetically modified PEEK derivatives, such as PEEK-ionenes, is considerable due to their ability to selectively capture CO 2 molecules and other light gases. Therefore, it is important to characterize the surface of these synthesized novel PEEK-ionenes. In this work, characteristic and unique peaks were identified in the positive spectra of each sample. The differences in mass spectra among the samples provide insights for optimizing or fine-tuning the PEEK-ionenes synthesis to achieve a high-performance CO 2 separation membrane with enhanced permeability, selectivity, and mechanical stability. The SIMS spectra and identified characteristic peaks of these synthesized ionenes will serve as a reference in the positive mode, complementing the corresponding spectra reported in the negative ion mode (Paper II).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

POWTEX visits POWGEN

The high-intensity time-of-flight (TOF) neutron diffractometer POWTEX for powder and texture analysis is currently being built prior to operation in the eastern guide hall of the research reactor FRM II at Garching close to Munich, Germany. Because of the world-wide 3 He crisis in 2009, the authors promptly initiated the development of 3 He-free detector alternatives that are tailor-made for the requirements of large-area diffractometers. Herein is reported the 2017 enterprise to operate one mounting unit of the final POWTEX detector on the neutron powder diffractometer POWGEN at the Spallation Neutron Source located at Oak Ridge National Laboratory, USA. As a result, presented here are the first angular- and wavelength-dependent data from the POWTEX detector, unfortunately damaged by a 50 g shock but still operating, as well as the efforts made both to characterize the transport damage and to successfully recalibrate the voxel positions in order to yield nonetheless reliable measurements. Also described is the current data reduction process using the PowderReduceP2D algorithm implemented in Mantid [Arnold et al. (2014). Nucl. Instrum. Methods Phys. Res. A , 764 , 156–166]. The final part of the data treatment chain, namely a novel multi-dimensional refinement using a modified version of the GSAS-II software suite [Toby & Von Dreele (2013). J. Appl. Cryst. 46 , 544–549], is compared with a standard data treatment of the same event data conventionally reduced as TOF diffraction patterns and refined with the unmodified version of GSAS-II . This involves both determining the instrumental resolution parameters using POWGEN's powdered diamond standard sample and the refinement of a friendly-user sample, BaZn(NCN) 2 . Although each structural parameter on its own looks similar upon comparing the conventional (1D) and multi-dimensional (2D) treatments, also in terms of precision, a closer view shows small but possibly significant differences. For example, the somewhat suspicious proximity of the a and b lattice parameters of BaZn(NCN) 2 crystallizing in Pbca as resulting from the 1D refinement (0.008 Å) is five times less pronounced in the 2D refinement (0.038 Å). Similar features are found when comparing bond lengths and bond angles, e.g. the two N—C—N units are less differently bent in the 1D results (173 and 175°) than in the 2D results (167 and 173°). The results are of importance not only for POWTEX but also for other neutron TOF diffractometers with large-area detectors, like POWGEN at the SNS or the future DREAM beamline at the European Spallation Source.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

3D reconstruction of an inertial-confinement fusion implosion with neural networks using multiple heterogeneous data sources

3D asymmetries are major degradation mechanisms in inertial-confinement fusion implosions at the National Ignition Facility (NIF). These asymmetries can be diagnosed and reconstructed with the neutron imaging system (NIS) on three lines of sight around the NIF target chamber. Conventional tomographic reconstructions are used to reconstruct the 3D morphology of the implosion using NIS [Volegov et al., J. Appl. Phys. 127, 083301 (2020)], but the problem is ill-posed with only three imaging lines of sight. Asymmetries can also be diagnosed with the real-time neutron activation diagnostics (RTNAD) and the neutron time-of-flight (nToF) suite. Since the NIS, RTNAD, and nToF each sample a different part of the implosion using different physical principles, we propose that it is possible to overcome the limitations of too few imaging lines of sight by performing 3D reconstructions that combine information from all three heterogeneous data sources. This work presents a new machine learning-based reconstruction technique to do just this. By using a simple physics model and group of neural networks to map 3D morphologies to data, this technique can easily account for data of multiple different types. A simple proof-of-principle is presented, demonstrating that this technique can accurately reconstruct a hot-spot shape using synthetic primary neutron images and a hot-spot velocity vector. In particular, the hot-spot’s asymmetry, quantified as spherical harmonic coefficients, is reconstructed to within ±4% of the radius in 90% of test cases. In the future, this technique will be applied to actual NIS, RTNAD, and nToF data to better understand 3D asymmetries at the NIF.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Aluminum hydroxide, bayerite, boehmite, and gibbsite ToF-SIMS spectra in the positive ion mode. II

We report time-of-flight secondary ion mass spectrometry (ToF-SIMS) was performed for boehmite (AOH-60) and its potential products of oxidation including pseudo-boehmite (AOH-180), α- and γ-Al 2 O 3 , and α- and γ-Al(OH) 3 . Since boehmite often forms on the cladding materials to prevent corrosion, surface analysis techniques are performed to determine the amount of oxidation present. This ToF-SIMS spectral library is of significance because it includes boehmite and its potential oxidation products (i.e., aluminum oxide and hydroxide), which can be used to compare to spectra obtained for real-world samples containing boehmite. Furthermore, ToF-SIMS is often used as a complementary technique to x-ray photoelectron spectroscopy (XPS) due to its surface sensitivity and ability to compare spectra via multivariate analysis, therefore establishing the molecular signatures of boehmite and relevant compounds are essential for peak identification. The SIMS spectra shown are acquired from commercially available powders, which were deposited onto a Si wafer substrate via liquid slurry drop casting. This library of SIMS mass spectra will serve as a comparison of boehmite [γ-AlO(OH)], pseudo-boehmite [AlOOH∙nH 2 O], α- and γ-Al 2 O 3 aluminum oxide, and α- and γ-Al 2 O 3 aluminum hydroxide in the positive ion mode, which compliments those reported in the negative ion mode (Part 1).

36 MATERIALS SCIENCE↗

ToF-SIMS spectral data analysis of Paenibacillus sp. 300A biofilms and planktonic cells

Analysis of bacterial biofilms is particularly challenging and important with diverse applications from systems biology to biotechnology. Among the variety of techniques that have been applied, time-of-flight secondary ion mass spectrometry (ToF-SIMS) has many promising features in studying the surface characteristics of biofilms. ToF-SIMS offers high spatial resolution and high mass accuracy, which permit surface sensitive analysis of biofilm components. Thus, ToF-SIMS provides a powerful solution to addressing the challenge of bacterial biofilm analysis. This dataset covers ToF-SIMS analysis of Paenibacillus sp. 300A (300A) isolated from the Hanford site in Richland, WA. The strain is known to have metal and sulfur reducing properties and can be used for bioremediation, wastewater treatment, bioengineering and technology development. There is a current need to identify small molecules and fragments produced from bacterial biofilms. Static ToF-SIMS spectra of 300A were obtained using an IONTOF TOF-SIMS V instrument equipped with a 25 keV Bi 3 + metal ion gun. Identified molecules and molecular fragments are compared against known biological databases and the reported peaks have at least 65 ppm mass accuracy. These molecules range from lipids and fatty acids to flavonoids, quinolones, and other naturally occurring organic compounds. It is anticipated that the spectral identification of key peaks will assist detection of metabolites, extracellular polymeric substance molecules like polysaccharides, and biologically relevant small molecules using ToF-SIMS in future surface and interface research of bacterial biofilms.

Biofilms↗

ToF-SIMS spectral analysis of Shewanella oneidensis MR-1 biofilms

Analysis of bacterial biofilms is particularly challenging and important with diverse applications from systems biology to biotechnology. Among the variety of techniques that have been applied, time-of-flight secondary ion mass spectrometry (ToF-SIMS) has many powerful features in studying the surface characteristics of biofilms. ToF-SIMS offers high spatial resolution, mass resolution, and mass accuracy, which permit surface sensitive analysis of biofilm components. Thus, ToF-SIMS provides a powerful solution to addressing the challenge of bacterial biofilm analysis. This dataset covers ToF-SIMS analysis of Shewanella oneidensis MR-1 isolated from freshwater lake sediment in New York state. The MR-1 strain is known to have metal and sulfur reducing properties and it can be used for bioremediation and wastewater treatment. There is a current need to identify small molecules and fragments produced from bacterial biofilms, especially those from extracellular polymeric substance (EPS). Static ToF-SIMS spectra of MR-1 were obtained using an IONTOF TOF.SIMS V instrument equipped with a 25 keV Bi$^+_3$ metal ion gun. Identified molecules and molecular fragments are compared against known biological databases and the reported peaks have at least 65 ppm mass accuracy. These molecules range from lipids, fatty acids, flavonoids, and quinolones to other naturally occurring organic compounds. It is anticipated that the mass spectral identification of key peaks will assist detection of metabolites, EPS molecules like polysaccharides, and biologically relevant small organic molecules using ToF-SIMS in future surface and interface research.

59 BASIC BIOLOGICAL SCIENCES↗

ToF-SIMS spectral analysis of pristine and neutron irradiated single crystal tungsten

Time-of-flight secondary ion mass spectrometry (ToF-SIMS) has many promising features in studying materials including high spatial resolution and high mass accuracy of elements, molecules, and isotopes. Its ability to resolve isotopes is especially attractive in studying transmutation products of single crystal tungsten (SCW) post neutron irradiation. Tungsten (W) is a contender of plasma facing materials (PFMs) due to its high thermal and radiological stability. PFMs to be used in the construction of fusion vessels are subject to high temperature and neutron irradiation, resulting in changes to materials including transmutation, which ultimately impact material mechanical and thermal properties. We used IONTOF TOF.SIMS V instrument equipped with a 30 keV Bi 3 + primary ion beam to study pristine SCW and irradiated SCW speciemens. Scanning electron microscope coupled with focused ion beam (SEM-FIB) was used to reduce the dosage of neutron irradiated tungsten and prepare for specimens for SIMS analysis. Static ToF-SIMS spectra were obtained, and transmutation product peak identification was presented in this work. Identified molecules and molecular fragments were compared against isotope theoretical mass to charge ratios of tungsten, rhenium, osmium, and other relevant products. Our results show that ToF-SIMS provides a viable means to study transmutation products of W post neutron irradiation. Such applications are suitable to investigate transmutation effects on materials that are being considered and developed for fusion pilot plants.

36 MATERIALS SCIENCE↗

Application of a Chemical Index to Aerosol Mass Spectrometry: Delta Plots and Functional Group Distributions

A better understanding of the chemical properties of organic aerosol (OA) particles will improve our ability to characterize their sources and predict their lifetime. The high-resolution time-of-flight aerosol mass spectrometer (HR-ToF-AMS) is widely used to measure OA in real time using thermal vaporization followed by electron ionization (EI). EI creates fragment ions that can be assigned to functional groups using delta analysis, a method of classifying mass spectra according to the presence of different chemically related ion series. In this study, we demonstrate the application of delta analysis to characterize molecular structures using a new visualization method. We also use delta analysis to quantify the functional group distribution with an average absolute error of ∼5–6% for individual standard molecules, comparable to the error observed for OA mixtures from biomass and coal combustion fit with Fourier transform infrared spectroscopy. Finally, we apply delta functional group analysis to AMS positive matrix factorization (PMF) factors across seven different field campaigns and find a similar composition across the more oxidized factors with about 55% acid and 26% alcohol groups. The analysis method described here can be applied to any HR-ToF-AMS data set to provide quantitative relative functional group distributions for OA mixtures.

aerosol↗

Pressure cells for in situ neutron total scattering: time and real-space resolution during deuterium absorption

In situ gas-loading sample holders for two-dimensionally arranged detectors in time-of-flight neutron total scattering experiments have been developed to investigate atomic arrangements during deuterium absorption using time and real-space resolution. A single-crystal sapphire container was developed that allows conditions of 473 K and 10 MPa hydrogen gas pressure. High-resolution transient measurements detected deuterium absorption by palladium that proceeded within a few seconds. A double-layered container with thick- and thin-walled vanadium allowed conditions of 423 K and 10 MPa hydrogen gas pressure. The deuterium occupation sites of a lanthanum–nickel–aluminium alloy are discussed in detail on the basis of real-space high-resolution data obtained from in situ neutron scattering measurements and reverse Monte Carlo structural modeling.

08 HYDROGEN↗

Design of the ion-optics for the MRSt neutron spectrometer at the National Ignition Facility (NIF)

A new Magnetic Recoil Spectrometer (MRSt) is designed to provide time-resolved measurements of the energy spectrum of neutrons emanating from an inertial confinement fusion implosion at the National Ignition Facility. At present, time integrated parameters are being measured using the existing magnet recoil and neutron time-of-flight spectrometers. The capability of high energy resolution of 2 keV and the extension to high time resolution of about 20 ps are expected to improve our understanding of conditions required for successful fusion experiments. The layout, ion-optics, and specifications of the MRSt will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CO2 Plume Imaging with Accelerated Deep Learning-based Data Assimilation Considering Multiple Realizations: Application to the Illinois Basin-Decatur Carbon Sequestration Project

We propose a fast and efficient deep learning workflow for near real-time data assimilation, forecasting and visualization of CO2 plume evolution in saline aquifer and demonstrate its application at a field site. Unlike the previous work, this study incorporates the impact of spatial heterogeneity using multiple realizations. In the proposed workflow, a neural network model utilizes available monitoring data such as downhole pressure measurements as input and predicts the propagating pressure ‘front’ using the diffusive time of flight (DTOF) map which is considered as representative reservoir image of the flow field. The DTOF is the arrival time of pressure front propagation, which can be computed by the Fast Marching Method rapidly without flow simulations. Reservoir model calibration can be implemented by selecting the training data samples that describe the predicted DTOF map based on observed data. The power and efficacy of our workflow is demonstrated by application to the Illinois Basin-Decatur Project.

CO2 plume imaging↗

Apparatus and method for shaped waveform interrogation

Described are an apparatus, computer program product, and associated methods for shaped waveform acoustic interrogation of substances and materials to determine one or more properties of the materials or substances. In some embodiments, a shaped waveform is formed by summing two or more different waveforms and an acoustic wave is generated according to the shaped waveform. The acoustic wave is transmitted by one or more transmitting transducers through the substance or material and received by one or more receiving transducers. The shaped waveform acoustic wave can have a duration or a period that is less than about 20 μs and can comprise predetermined frequency content. Characteristics of the shaped waveform acoustic wave, as received at the receiving transducer(s), including characteristics such as amplitude, frequency, time of flight, etc., can be associated with said one or more properties of the substance or material to provide for real-time monitoring of these properties.

Sinha, Dipen N.↗

Liquid ToF-SIMS revealing the oil, water, and surfactant interface evolution

Bilge water from ships is regarded as a major pollutant in the marine environment. Bilge water exists in a stable oil-in-water (O/W) emulsion form. However, little is known about the O/W liquid–liquid (l–l) interface. Traditional bulk characterization approaches are not capable of capturing the chemical changes at the O/W l–l interface. Although surfactants are deemed essential in droplet formation, their roles in bilge water stabilization have not been fully revealed. We have utilized novel in situ chemical imaging tools including in situ scanning electron microscopy (SEM) and in situ time-of-flight secondary ion mass spectrometry (ToF-SIMS) to study the evolving O/W interface using a NAVY bilge model for the first time. The droplet size distribution (DSD) does not change significantly without the addition of X-100 surfactants under static or rocking conditions. Both the oil components and the water clusters are shown to evolve over time at the O/W droplet interface by in situ liquid SIMS imaging. Of particular interest to droplet stabilization, the contribution of surfactants to the aged bilge droplets becomes more significant as the droplet size increases. The higher mass surfactant component does not appear on the droplet surface immediately while many lower mass surfactants are solvated inside the droplet. We have provided the first three-dimensional images of the evolving O/W interface and demonstrated that in situ surface chemical mapping is powerful enough to reveal the complex and dynamic l–l interface in the liquid state. Our observational insights suggest that surfactants are important in mediating droplet growth and facilitating effective separation of bilge water emulsion.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Organic glass scintillator bars with dual-ended readout

Organic glass scintillator (OGS) bars (6 × 6 × 50 mm 3 ) were melt-cast and characterized with dual-ended readout by silicon photomultiplier arrays. The results were compared to trans-stilbene bars of the same size. Energy resolution was measured via a 137 Cs Compton-coincidence experiment. Time resolution was determined via a 22 Na coincidence-timing experiment. Depth-of-interaction resolution was measured by moving a gamma ray fan beam along the major axis of the bars. Pulse shape discrimination capability and neutron light output were determined via a time-of-flight measurement of a 252 Cf source. The OGS bars exhibited better energy resolution at 478 keV (10.3 ± 0.5% vs. 11.2 ± 0.5%), better time resolution from 200–341 keVee (270 ps vs. 340 ps FWHM), slightly poorer depth-of-interaction resolution, poorer PSD performance, and higher neutron light output than the stilbene bars. Here, the low cost, ease of manufacturing, brightness, and excellent time resolution make OGS a strong candidate for use in compact radiation imaging systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗