Search NASA⌕ Search

SEARCH · Search NASA

Results for “time resolved”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Time-resolved and multiple-angle Thomson scattering on gas-puff Z-Pinch plasmas at pinch time

A 526.5 nm Thomson scattering diagnostic laser enables probing of the plasma conditions of neon gas-puff z-pinch implosions with temporal resolution. Splitting the laser into two 2.5 J pulses, both 2.3 ns in duration and separated by 4 ns, allows observation of sub-nanosecond time-resolved spectra for a total time of 7 ns. Collection optics were set at 90° and 30° to the laser, observing the same on-axis scattering volume with a radial extent of 0.4 mm. The spectra from both angles were collected by using the same streak camera, using a coupling system that allowed us to obtain temporal, spectral, and angular resolution in the same image. By comparing the ion-acoustic spectra from the two angles, we determined electron temperature and a range of possible electron densities. Measurements made in the 1-3 ns period before pinch time show best fit (determined by a least-squares method) electron densities of around 2 × 10 19 cm -3 , increasing to 1.5 × 10 20 cm -3 in the 3 ns following the start of the x-ray burst (t = 0 ns) from the pinch. The electron temperature increases from 300 eV to 500 eV at t = 0 ns before decreasing to below 300 eV after pinch time. With the present parameters (probe beam, collection angles, and electron temperature and density), this diagnostic method is too insensitive to electron density to provide more than a constraint on that parameter. Plasma regimes in which this technique could determine electron density with some precision are calculated.

47 OTHER INSTRUMENTATION↗

Time-resolved cryogenic electron tomography for the study of transient cellular processes

Cryogenic electron tomography (cryo-ET) is the highest resolution imaging technique applicable to the life sciences, enabling sub-nanometer visualization of specimens preserved in their near native states. The rapid plunge freezing process used to prepare samples lends itself to time-resolved studies, which researchers have pursued for in vitro samples for decades. Here, we focus on developing a freezing apparatus for time-resolved studies in situ. The device mixes cellular samples with solution-phase stimulants before spraying them directly onto an electron microscopy grid that is transiting into cryogenic liquid ethane. By varying the flow rates of cell and stimulant solutions within the device, we can control the reaction time from tens of milliseconds to over a second prior to freezing. In a proof-of-principle demonstration, the freezing method is applied to a model bacterium, Caulobacter crescentus, mixed with an acidic buffer. Through cryo-ET we resolved structural changes throughout the cell, including surface-layer protein dissolution, outer membrane deformation, and cytosolic rearrangement, all within 1.5 seconds of reaction time. This new approach, Time-Resolved cryo-ET (TR-cryo-ET), enhances the capabilities of cryo-ET by incorporating a sub-second temporal axis and enables the visualization of induced structural changes at the molecular, organelle, or cellular level.

59 BASIC BIOLOGICAL SCIENCES↗

Time-resolved photoelectron imaging of complex resonances in molecular nitrogen

We have used the FERMI free-electron laser to perform time-resolved photoelectron imaging experiments on a complex group of resonances near 15.38 eV in the absorption spectrum of molecular nitrogen, N-2, under jet-cooled conditions. The new data complement and extend the earlier work of Fushitani et al. [Opt. Express 27, 19702-19711 (2019)], who recorded time-resolved photoelectron spectra for this same group of resonances. Time-dependent oscillations are observed in both the photoelectron yields and the photoelectron angular distributions, providing insight into the interactions among the resonant intermediate states. In addition, for most states, we observe an exponential decay of the photoelectron yield that depends on the ionic final state. This observation can be rationalized by the different lifetimes for the intermediate states contributing to a particular ionization channel. Finally, although there are nine resonances within the group, we show that by detecting individual photoelectron final states and their angular dependence, we can identify and differentiate quantum pathways within this complex system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Subcycle interference dynamics of time-resolved photoelectron holography with midinfrared laser pulses

Time-resolved photoelectron holography from atoms using midinfrared laser pulses is investigated by solving the corresponding time-dependent Schroedinger equation (TDSE) and a classical model, respectively. The numerical simulation of the photoelectron angular distribution of Xe irradiated with a low-frequency free-electron laser source agrees well with the experimental results. Different types of subcycle interferometric structures are predicted by the classical model. Furthermore with the TDSE model it is demonstrated that the holographic pattern is sensitive to the shape of the atomic orbitals. This is a step toward imaging by means of photoelectron holography.

74 ATOMIC AND MOLECULAR PHYSICS↗

CCD time-resolved photometry of faint cataclysmic variables. IV

Time-resolved CCD photometry in V, B, and the near-IR has been obtained, with average time-series length of 3 hours, for 15 certified or candidate cataclysmic-variable faint stars. Orbital periods are found in three of the stars, and nine others are noted to exhibit evidence leading toward confirmation of cataclysmic-variable status. The characteristics of PG 0917+342 and PG 2240+193 are as yet unclear.

Howell, Steve B.↗

Time-Resolved Measurement of Landau-Zener Tunneling in Periodic Potentials

We report time-resolved measurements of Landau-Zener tunneling of Bose-Einstein condensates in accelerated optical lattices, clearly resolving the steplike time dependence of the band populations. Using different experimental protocols we were able to measure the tunneling probability both in the adiabatic and in the diabatic bases of the system. We also experimentally determine the contribution of the momentum width of the Bose condensates to the temporal width of the tunneling steps and discuss the implications for measuring the jump time in the Landau-Zener problem.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Time-Resolved Rayleigh Scattering Measurements in Hot Gas Flows

A molecular Rayleigh scattering technique is developed to measure time-resolved gas velocity, temperature, and density in unseeded gas flows at sampling rates up to 32 kHz. A high power continuous-wave laser beam is focused at a point in an air flow field and Rayleigh scattered light is collected and fiber-optically transmitted to the spectral analysis and detection equipment. The spectrum of the light, which contains information about the temperature and velocity of the flow, is analyzed using a Fabry-Perot interferometer. Photomultipler tubes operated in the photon counting mode allow high frequency sampling of the circular interference pattern to provide time-resolved flow property measurements. Mean and rms velocity and temperature fluctuation measurements in both an electrically-heated jet facility with a 10-mm diameter nozzle and also in a hydrogen-combustor heated jet facility with a 50.8-mm diameter nozzle at NASA Glenn Research Center are presented.

Mielke, Amy F.↗

Time-resolved intensity of ArXXVII resonance line for plasma diagnostics during high pressure gas injection

Paper describes simulations of time-resolved intensity of ArXVII-lines during high pressure gas injection in tokamak. Model consists of two parts: MHD part and CR part. MHD part is based on energy balance equations with special attention to generation of fast electrons and radiation losses. Time-dependent CR part calculates the distribution of Ar0-ArXIX and population of the levels in plasma with opacity effect and diagnostic admixture before injection.The results of calculations of plasma parameters (n{sub e}, n{sub i}, T{sub e}, T{sub i}, radiation peak) are in good agreement with experiments on DIII-D. Calculated time-resolved intensity of w-line (ArXVII) shows high sensitivity to plasma parameters during injection. Presented approach might become an efficient way to understand physics of gas penetration and dissipation of plasma energy within gas injection. Experiment might be carried out using X-ray spectrometer for T{sub i} measurements from Doppler broadening.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Photophysical and Time‐resolved Infrared Properties of Long‐Lived Rhenium(I) 4,5‐Diazafluorene Tricarbonyl Chromophores

This report investigates the synthesis, structural characterization, fundamental molecular photophysics, electrochemistry, UV-Vis spectroelectrochemistry, and time-resolved infrared spectroscopic properties of eight [fac-Re(dafR)(CO) 3 L] 0/+ complexes, where R=ethyl [(dedaf); 1, 3, 5, 7] or H [(dafH); 2, 4, 6, 8] and L=Cl− (1, 2), imidazole [(Im); 3, 4], 4-ethylpyridine [(4-Etpy); 5, 6], or pyridine [(py); 7, 8]. Universally, 1–8 yield higher energy photoluminescence (PL) emission bands and higher PL quantum yields (up to 53 %) than the classic 2,2’-bipyridine (bpy) and 1,10-phenanthroline (phen) ligated Re(I) tricarbonyl complexes. The excited state lifetimes of 1–8 lie between those corresponding to the bpy and phen derivatives, ranging from 120 and 1300 ns at room temperature. Combinations of reductive UV-Vis spectroelectrochemistry, transient absorption spectroscopy, and time-resolved infrared spectroscopy consistently assigned the lowest excited states in 1–8 being of metal-to-ligand charge transfer (MLCT) character. These new ReI MLCT chromophores follow classic energy gap law behavior and possess the characteristics necessary for serving as valuable photosensitizers suitable to energize excited state electron and energy transfer photochemistry.

Charge transfer↗

Validation and Uncertainty Analysis of Stereo Time-Resolved PIV Measurements for Boundary-Layer Transition Research

An uncertainty analysis was performed on the stereo time-resolved particle image velocimetry measurements that were obtained in the boundary-layer of a swept wing model. Several different approaches were undertaken to estimate the uncertainty of the PIV measurements and to understand how that uncertainty propagates through to the results of interest. It was found that the stereo registration error, which is often neglected in stereo- PIV uncertainty analysis, can cause significant errors in the measured amplitude of the stationary cross ow instability due to the large spanwise velocity gradients that occur in the ow. The self-calibrations do not always adequately correct for the stereo-registration error. A simple approach is demonstrated for estimating the error due to a misalignment of the calibration target and laser plane. This approach was found to be very successful at predicting the error in stationary cross ow amplitude caused by the misalignment. The time-resolved PIV results are also compared to previously-acquired hotwire data. The TRPIV technique is successful at measuring the same types of unsteady instabilities as the hotwire, and thus does not appear to have any adverse e ect on the transition process due to the introduction of particles into the ow. It was also found that a larger interrogation window size is beneficial for reducing the noise of the TRPIV results.

Eppink, Jenna L.↗

Experimental and theoretical studies of time-averaged and time resolved rotor heat transfer

Efforts in support of the Space Shuttle Main Engine (SSME) structural durability program have concentrated on obtaining detailed time-averaged and time-resolved (or phase-locked) measurements on a full-scale rotating turbine both with and without cold gas injection and on theoretical studies designed to improve the prediction capability for these turbine flows. The experimental efforts have concentrated on use of the Garrett TFE 731-2 hp turbine. However, it has been possible to apply the theoretical efforts to predicting heat-flux distributions obtained for two additional turbines - i.e., (1) the Garrett low aspect ratio turbine (LART) and (2) the Teledyne 702 turbine. The experimental technique is the short duration, shock-tunnel approach, in which fast-response, thin-film resistance thermometers are used to measure surface temperature histories at prescribed locations on the turbine component parts. Heat-flux values are then inferred from the temperature histories by using standard data reduction procedures. The turbine being used is the Garrett TFE 731-2 hp stage, and both the nozzle guide vanes and the rotor blades are heavily instrumented with thin-film heat-flux gauges. Depending on how the data from a particular heat-flux gauge are recorded, one can get either time-resolved (or phase-locked) or time-averaged results. Both types of data are illustrated.

Dunn, M. G.↗

Automating the interpretation of PM 2.5 time–resolved measurements using a data–driven approach

The rapid development of automated measurement equipment enables researchers to collect greater quantities of time-resolved data from indoor and outdoor environments. While significant, the interpretation of the resulting data can be a time-consuming effort. This paper introduces an automated process of interpreting PM 2.5 time-resolved data and differentiating PM 2.5 emissions resulting from indoor and outdoor sources. Here, we use Random Forest (RF), a machine learning approach, to study a dataset of 836 indoor emission events that occurred over a 2-week period in 18 apartments in California. In this paper, we show model development and evaluate its performance as the sample size and source vary. We discuss the characteristics of the dataset that tended to help the source identification and why. For example, we show that data from many events and from different apartments are essential for the model to be suitable for analyzing a new separate dataset. We also show that longitudinal data appear to be more helpful than the time frequency of measurements within a given apartment. We use the resulting RF model to analyze PM 2.5 data of an entirely separate dataset collected from 65 new homes in California. The RF model identifies 442 indoor emission events, with only a few misidentifications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Time-Resolved X-Ray Crystallography of Heme Proteins

Heme proteins, with their natural photosensitivity, are excellent systems for the application of time-resolved crystallographic methods. Ligand dissociation can be readily initiated by a short laser pulse with global structural changes probed at the atomic level by X-rays in real time. Third-generation synchrotrons provide 100-ps X-ray pulses of sufficient intensity for monitoring very fast processes. Successful application of such time-resolved crystallographic experiments requires that the structural changes being monitored are compatible with the crystal lattice. These techniques have recently permitted observing for the first time allosteric transitions in real time for a cooperative dimeric hemoglobin.

59 BASIC BIOLOGICAL SCIENCES↗

Three-dimensional, Time-Resolved, Intrafraction Motion Monitoring Throughout Stereotactic Liver Radiation Therapy on a Conventional Linear Accelerator

Purpose: To investigate the time-resolved 3-dimensional (3D) internal motion throughout stereotactic body radiation therapy (SBRT) of tumors in the liver using standard x-ray imagers of a conventional linear accelerator. Methods and Materials: Ten patients with implanted gold markers received 11 treatment courses of 3-fraction SBRT in a stereotactic body-frame on a conventional linear accelerator. Two pretreatment and 1 posttreatment cone-beam computed tomography (CBCT) scans were acquired during each fraction. The CBCT projection images were used to estimate the internal 3D marker motion during CBCT acquisition with 11-Hz resolution by a monoscopic probability-based method. Throughout the treatment delivery by conformal or volumetric modulated arc fields, simultaneous MV portal imaging (8 Hz) and orthogonal kV imaging (5 Hz) were applied to determine the 3D marker motion using either MV/kV triangulation or the monoscopic method when marker segmentation was unachievable in either MV or kV images. The accuracy of monoscopic motion estimation was quantified by also applying monoscopic estimation as a test for all treatments during which MV/kV triangulation was possible. Results: Root-mean-square deviations between monoscopic estimations and triangulations were less than 1.0 mm. The mean 3D intrafraction and intrafield motion ranges during liver SBRT were 17.6 mm (range, 5.6-39.5 mm) and 11.3 mm (2.1-35.5mm), respectively. The risk of large intrafraction baseline shifts correlated with intrafield respiratory motion range. The mean 3D intrafractional marker displacement relative to the first CBCT was 3.4 mm (range, 0.7-14.5 mm). The 3D displacements exceeded 8.8 mm 10% of the time. Conclusions: Highly detailed time-resolved internal 3D motion was determined throughout liver SBRT using standard imaging equipment. Considerable intrafraction motion was observed. The demonstrated methods provide a widely available approach for motion monitoring that, combined with motion-adaptive treatment techniques, has the potential to improve the accuracy of radiation therapy for moving targets.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Time-Resolved X-Ray Microscopy for Materials Science

X-ray microscopy has been an indispensable tool to image nanoscale properties for materials research. One of its recent advances is extending microscopic studies to the time domain to visualize the dynamics of nanoscale phenomena. Large-scale X-ray facilities have been the powerhouse of time-resolved X-ray microscopy. Their upgrades, including a significant reduction of the X-ray emittance at storage rings (SRs) and fully coherent ultrashort X-ray pulses at free-electron lasers (FELs), will lead to new developments in instrumentation and will open new scientific opportunities for X-ray imaging of nanoscale dynamics with the simultaneous attainment of unprecedentedly high spatial and temporal resolutions. As a result, this review presents recent progress in and the outlook for time-resolved X-ray microscopy in the context of ultrafast nanoscale imaging and its applications to condensed matter physics and materials science.

36 MATERIALS SCIENCE↗

All-Digital Time-Resolved Spot Diagnostic

Presentation describes research into construction of a time-resolved spot diagnostic using mostly commercial off-the-shelf components, with system requirements to include (among others) comparable or better signal-to-noise ratio than a streak camera; low-loss fiber network, likely less than a few dB; optimized interface to the scintillators; and fast detectors to capture the pulse shape, 500 MHz to 1 GHz analog bandwidth with good linearity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Excited state dynamics of cis , cis -1,3-cyclooctadiene: UV pump VUV probe time-resolved photoelectron spectroscopy

We present UV pump, vacuum ultraviolet probe time-resolved photoelectron spectroscopy measurements of the excited state dynamics of cis,cis-1,3-cyclooctadiene. A 4.75 eV deep UV pump pulse launches a vibrational wave packet on the first electronically excited state, and the ensuing dynamics are probed via ionization using a 7.92 eV probe pulse. The experimental results indicate that the wave packet undergoes rapid internal conversion to the ground state in under 100 fs. Comparing the measurements with electronic structure and trajectory surface hopping calculations, we are able to interpret the features in the measured photoelectron spectra in terms of ionization to several states of the molecular cation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗