Search NASA⌕ Search

SEARCH · Search NASA

Results for “tomography problems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Microcracking Study of Carbon Fiber Composite Materials for Starshade Petals

We have conducted materials tests of representative carbon composite materials for starshade petals. The principal goal of these tests is to assess whether the level of microcracking of the materials as the petals are stowed or deployed (or even as they are handled during assembly) is likely to cause a problem with meeting the tight dimensional tolerances required for starlight suppression. Cracking can cause unexpected deformation, and the cracks can act as reservoirs for gases. It may also lead to roughening of the optical edge whose sharpness minimizes undesirable scattering of light. We use mechanical tests, microscopy, acoustic tomography and small‐angle x‐ray scattering to characterize the microcracking. These tests have found no large cracks (>100 microns) at bending strains up to 0.005, the strain at which audible popping occurred. The stress‐strain curves did not display any anomalies until a precipitous drop in stress at a strain of ~0.012 due to the formation of a transverse crack. Analysis of SAXS data is on‐going which will quantify microcrack distributions at the sub‐micron level. We find no large cracks (>100 microns) at the design strain tolerance for non‐critical structural elements (0.005); analysis is on‐going to quantify nanoscale cracking at the strains of critical structural elements (0.0005).

36 MATERIALS SCIENCE↗

Deep-learning-based workflow for boundary and small target segmentation in digital rock images using UNet++ and IK-EBM

We report three-dimensional (3D) X-ray micro-computed tomography (μCT) has been widely used in petroleum engineering because it can provide detailed pore structural information for a reservoir rock, which can be imported into a pore-scale numerical model to simulate the transport and distribution of multiple fluids in the pore space. The partial volume blurring (PVB) problem is a major challenge in segmenting raw μCT images of rock samples, which impacts boundaries and small targets near the resolution limit. We developed a deep-learning (DL)-based workflow for accurate and fast partial volume segmentation. The DL model's performance depends primarily on the training data quality and model architecture. This study employed the entropy-based-masking indicator kriging (IK-EBM) to segment 3D Berea sandstone images as training datasets. The comparison between IK-EBM and manual segmentation using a 3D synthetic sphere pack, which had a known ground truth, showed that IK-EBM had higher accuracy on partial volume segmentation. We then trained and tested the UNet++ model, a state-of-the-art supervised encoder-decoder model, for binary (i.e., void and solid) and four-class segmentation. We compared the UNet++ with the commonly used U-Net and wide U-Net models and showed that the UNet++ had the best performance in terms of pixel-wise and physics-based evaluation metrics. Specifically, boundary-scaled accuracy demonstrated that the UNet++ architecture outperformed the regular U-Net architecture in the segmentation of pixels near boundaries and small targets, which were subjected to the PVB effect. Feature map visualization illustrated that the UNet++ bridged the semantic gaps between the feature maps extracted at different depths of the network, thereby enabling faster convergence and more accurate extraction of fine-scale features. The developed workflow significantly enhances the performance of supervised encoder-decoder models in partial volume segmentation, which has extensive applications in fundamental studies of subsurface energy, water, and environmental systems.

02 PETROLEUM↗

Equally sloped X-ray microtomography of living insects with low radiation dose and improved resolution capability

Three-dimensional X-ray imaging of living specimens is challenging due to the limited resolution of conventional absorption contrast X-ray imaging and potential irradiation damage of biological specimens. In this letter, we present microtomography of a living specimen combining phase-contrast imaging and a Fourier-based iterative algorithm termed equally sloped tomography. Non-destructive 3D imaging of an anesthetized living yellow mealworm Tenebrio molitor was demonstrated with a relatively low dose using synchrotron generated X-rays. Based on the high-quality 3D images, branching tracheoles and different tissues of the insect in a natural state were identified and analyzed, demonstrating a significant advantage of the technique over conventional X-ray radiography or histotomy. Additionally, the insect survived without problem after a 1.92-s X-ray exposure and subsequent absorbed radiation dose of ∼1.2 Gy. No notable physiological effects were observed after reviving the insect from anesthesia. The improved static tomographic method demonstrated in this letter shows advantage in the non-destructive structural investigation of living insects in three dimensions due to the low radiation dose and high resolution capability, and offers many potential applications in biological science.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Practical and reliable error bars for quantum process tomography

Current techniques in quantum process tomography typically return a single point estimate of an unknown process based on a finite albeit large amount of measurement data. Due to statistical fluctuations, however, other processes close to the point estimate can also produce the observed data with near certainty. Unless appropriate error bars can be constructed, the point estimate does not carry any sound operational interpretation. Here, we provide a solution to this problem by constructing a confidence region estimator for quantum processes. Our method enables reliable estimation of essentially any figure of merit for quantum processes on few qubits, including the diamond distance to a specific noise model, the entanglement fidelity, and the worst-case entanglement fidelity, by identifying error regions which contain the true state with high probability. We also provide a software package, QPtomographer, implementing our estimator for the diamond norm and the worst-case entanglement fidelity. We illustrate its usage and performance with several simulated examples. Furthermore, our tools can be used to reliably certify the performance of, e.g., error correction codes, implementations of unitary gates, or more generally any noise process affecting a quantum system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Iterative Reconstruction for Multimodal Neutron Tomography

Here, we describe a unified framework for model-based iterative 3-D reconstruction of multimodal neutron transmission, hydrogen-scatter, and induced-fission images from low resolution data recorded using 14.1-MeV neutrons and the associated-particle imaging (API) technique. The framework, which was developed to facilitate use in challenging field-deployment scenarios, is centered around physics-based system models and a total variation (TV) constrained implementation of the simultaneous iterative reconstruction technique (SIRT). Modified to solve a statistically weighted least squares (WLS) problem, the SIRT algorithm is accelerated using ordered subsets and Nesterov’s momentum for which we derive a near-optimal value of the governing Lipschitz constant. The approach enables the reconstruction of images that are high resolution compared to the acquired data and is robust to both limited statistics and a limited number of projection angles. Moreover, the framework is fast enough to be practical. Example images are provided that demonstrate both the ability to perform fast-neutron imaging of high-atomic-number materials with low radiation dose and the benefit of multimodal neutron imaging to identify key materials.

Hydrogen scatter↗

Graph-learning approach to combine multiresolution seismic velocity models

SUMMARY The resolution of velocity models obtained by tomography varies due to multiple factors and variables, such as the inversion approach, ray coverage, data quality, etc. Combining velocity models with different resolutions can enable more accurate ground motion simulations. Toward this goal, we present a novel methodology to fuse multiresolution seismic velocity maps with probabilistic graphical models (PGMs). The PGMs provide segmentation results, corresponding to various velocity intervals, in seismic velocity models with different resolutions. Further, by considering physical information (such as ray path density), we introduce physics-informed probabilistic graphical models (PIPGMs). These models provide data-driven relations between subdomains with low (LR) and high (HR) resolutions. Transferring (segmented) distribution information from the HR regions enhances the details in the LR regions by solving a maximum likelihood problem with prior knowledge from HR models. When updating areas bordering HR and LR regions, a patch-scanning policy is adopted to consider local patterns and avoid sharp boundaries. To evaluate the efficacy of the proposed PGM fusion method, we tested the fusion approach on both a synthetic checkerboard model and a fault zone structure imaged from the 2019 Ridgecrest, CA, earthquake sequence. The Ridgecrest fault zone image consists of a shallow (top 1 km) high-resolution shear-wave velocity model obtained from ambient noise tomography, which is embedded into the coarser Statewide California Earthquake Center Community Velocity Model version S4.26-M01. The model efficacy is underscored by the deviation between observed and calculated traveltimes along the boundaries between HR and LR regions, 38 per cent less than obtained by conventional Gaussian interpolation. The proposed PGM fusion method can merge any gridded multiresolution velocity model, a valuable tool for computational seismology and ground motion estimation.

Geochemistry & Geophysics↗

3D reconstruction of the magnetic vector potential using model based iterative reconstruction

Lorentz transmission electron microscopy (TEM) observations of magnetic nanoparticles contain information on the magnetic and electrostatic potentials. Vector field electron tomography (VFET) can be used to reconstruct electromagnetic potentials of the nanoparticles from their corresponding LTEM images. The VFET approach is based on the conventional filtered back projection approach to tomographic reconstructions and the availability of an incomplete set of measurements due to experimental limitations means that the reconstructed vector fields exhibit significant artifacts. In this paper, we outline a model-based iterative reconstruction (MBIR) algorithm to reconstruct the magnetic vector potential of magnetic nanoparticles. We combine a forward model for image formation in TEM experiments with a prior model to formulate the tomographic problem as a maximum a-posteriori probability estimation problem (MAP). The MAP cost function is minimized iteratively to determine the vector potential. Here, a comparative reconstruction study of simulated as well as experimental data sets show that the MBIR approach yields quantifiably better reconstructions than the VFET approach.

36 MATERIALS SCIENCE↗

Improved proton computed tomography by dual modality image reconstruction

Purpose: Proton computed tomography (CT) is a promising image modality for improving the stopping power estimates and dose calculations for particle therapy. However, the finite range of about 33 cm of water of most commercial proton therapy systems limits the sites that can be scanned from a full 360° rotation. In this paper the authors propose a method to overcome the problem using a dual modality reconstruction (DMR) combining the proton data with a cone-beam x-ray prior. Methods: A Catphan 600 phantom was scanned using a cone beam x-ray CT scanner. A digital replica of the phantom was created in the Monte Carlo code Geant4 and a 360° proton CT scan was simulated, storing the entrance and exit position and momentum vector of every proton. Proton CT images were reconstructed using a varying number of angles from the scan. The proton CT images were reconstructed using a constrained nonlinear conjugate gradient algorithm, minimizing total variation and the x-ray CT prior while remaining consistent with the proton projection data. The proton histories were reconstructed along curved cubic-spline paths. Results: The spatial resolution of the cone beam CT prior was retained for the fully sampled case and the 90° interval case, with the MTF = 0.5 (modulation transfer function) ranging from 5.22 to 5.65 linepairs/cm. In the 45° interval case, the MTF = 0.5 dropped to 3.91 linepairs/cm For the fully sampled DMR, the maximal root mean square (RMS) error was 0.006 in units of relative stopping power. For the limited angle cases the maximal RMS error was 0.18, an almost five-fold improvement over the cone beam CT estimate. Conclusions: Dual modality reconstruction yields the high spatial resolution of cone beam x-ray CT while maintaining the improved stopping power estimation of proton CT. In the case of limited angles, the use of prior image proton CT greatly improves the resolution and stopping power estimate, but does not fully achieve the quality of a 360° proton CT scan.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Noninvasive 3D Visualization of Defects and Crack Propagation in Layered Foam Structures by Phase Contrast Microimaging

Applications of polymeric foams in our modern society continue to grow because of their light weight, high strength, excellent thermal and mechanical insulation, and the ease of engineering. Among others, closed-cell foam has been structurally used for thermally insulating the shuttle external tank. However, internal defects of the foams were difficult to observe non-invasively due to limited sensitivity to the low-density structures possessed by traditional imaging tools such as computed X-ray tomography By combining phase contrast X-ray imaging with pressure loading, we succeeded in precisely mapping intact cellular structure and defects inside the bulk of layered foam and visualizing its subsequent response to the pressure in three-dimensional space. The work demonstrated a powerfir1 approach for yielding insight into underlying problems in lightweight cellular materials otherwise unobtainable.

Hu, Z. W.↗

Study of continuous-wave domain fluorescence diffuse optical tomography for quality control on agricultural produce

The importance of monitoring the quality of vegetables and fruits is prosperity by giving a competitive advantage for producer and providing a more healthy food for consumer. Diffuse Optical Tomography (DOT) is offering the possibility to detect the internal defects of the agricultural produce quality. Fluorescence diffuse optical tomography (FDOT) is the development of DOT, offering the possibilities to improve spatial resolution and to contrast image. The purpose of this research is to compare FDOT and DOT in forward analysis with continuous wave approach. The scattering and absorbing parameters of potatoes are used to represent the real condition. The object was illuminated by the NIR source from some positions on the boundary of object. A set of NIR detector are placed on the peripheral position of the object to measure the intensity of propagated or emitted light. In the simulation, we varied a condition of object then we analyzed the sensitivity of forward problem. The result of this study shows that FDOT has a better sensitivity than DOT and a better potential to monitor internal defects of agricultural produce because of the contrast value between optical and fluorescence properties of agricultural produce normal tissue and defects.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simulation of unsteady blood flows in a patient-specific compliant pulmonary artery with a highly parallel monolithically coupled fluid-structure interaction algorithm

Computational fluid dynamics (CFD) is increasingly used to study blood flows in patient-specific arteries for understanding certain cardiovascular diseases. The techniques work quite well for relatively simple problems, but need improvements when the problems become harder in the case when (1) the geometry becomes complex (from a few branches to a full pulmonary artery), (2) the model becomes more complex (from fluid-only calculation to coupled fluid-structure interaction calculation), (3) both the fluid and wall models become highly nonlinear, and (4) the computer on which we run the simulation is a supercomputer with tens of thousands of processor cores. To push the limit of CFD in all four fronts, in this paper, we develop and study a highly parallel algorithm for solving a monolithically coupled fluid-structure system for the modeling of the interaction of the blood flow and the arterial wall. As a case study, we consider a patient-specific, full size pulmonary artery obtained from CT (Computed Tomography) images, with an artificially added layer of wall with a fixed thickness. The fluid is modeled with a system of incompressible Navier-Stokes equations and the wall is modeled by a geometrically nonlinear elasticity equation. As far as we know this is the first time the unsteady blood flow in a full pulmonary artery is simulated without assuming a rigid wall. We report the proposed numerical algorithm and software scale well beyond 10,000 processor cores on a supercomputer for solving the fluid-structure interaction problem discretized with a stabilized finite element method in space and an implicit scheme in time involving hundreds of millions of unknowns.

97 MATHEMATICS AND COMPUTING↗

Mapping of reciprocal space of La{sub 0.30}CoO{sub 2} in 3D: Analysis of superstructure diffractions and intergrowths with Co{sub 3}O{sub 4}

We have used electron diffraction tomography and powder X-ray diffraction to elucidate the structural properties of layered cobaltate γ-La{sub 0.30}CoO{sub 2}. The structure consists of hexagonal sheets of edge-sharing CoO{sub 6} octahedra interleaved by lanthanum monolayers. The La{sup 3+} cations occupy only one third of available P2 sites, forming a 2-dimensional a√3×a√3 superstructure in a–b plane. The results show that there exists no order in the mutual relative shift between the neighbouring La interlayers within the a–b plane. This is manifested in the observed monotonous decrease of the diffracted intensity of the superstructure diffractions along c{sup ⁎} in both X-ray and electron diffraction data. The observed lack of stacking order differentiates the La{sub x}CoO{sub 2} from its Ca and Sr analogues where at least a partial stacking order of the cationic interlayers is manifested in experimental data published in literature. - Highlights: • We use electron diffraction tomography for reciprocal space mapping of La{sub 0.30}CoO{sub 2}. • We observed a complete disorder of the stacking of Lanthanum interlayers. • Co{sub 3}O{sub 4} intergrown with La{sub 0.30}CoO{sub 2} crystals brings about fake superstructure diffractions. • Twinning of Co{sub 3}O{sub 4} enhances the problem of fake superstructure diffractions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Interior micro-CT with an offset detector

Purpose: The size of field-of-view (FOV) of a microcomputed tomography (CT) system can be increased by offsetting the detector. The increased FOV is beneficial in many applications. All prior investigations, however, have been focused to the case in which the increased FOV after offset-detector acquisition can cover the transaxial extent of an object fully. Here, the authors studied a new problem where the FOV of a micro-CT system, although increased after offset-detector acquisition, still covers an interior region-of-interest (ROI) within the object. Methods: An interior-ROI-oriented micro-CT scan with an offset detector poses a difficult reconstruction problem, which is caused by both detector offset and projection truncation. Using the projection completion techniques, the authors first extended three previous reconstruction methods from offset-detector micro-CT to offset-detector interior micro-CT. The authors then proposed a novel method which combines two of the extended methods using a frequency split technique. The authors tested the four methods with phantom simulations at 9.4%, 18.8%, 28.2%, and 37.6% detector offset. The authors also applied these methods to physical phantom datasets acquired at the same amounts of detector offset from a customized micro-CT system. Results: When the detector offset was small, all reconstruction methods showed good image quality. At large detector offset, the three extended methods gave either visible shading artifacts or high deviation of pixel value, while the authors’ proposed method demonstrated no visible artifacts and minimal deviation of pixel value in both the numerical simulations and physical experiments. Conclusions: For an interior micro-CT with an offset detector, the three extended reconstruction methods can perform well at a small detector offset but show strong artifacts at a large detector offset. When the detector offset is large, the authors’ proposed reconstruction method can outperform the three extended reconstruction methods by suppressing artifacts and maintaining pixel values.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

HamPerf: A Hamiltonian-Oriented Approach to Quantum Benchmarking

Quantum computing technologies are undergoing rapid development. The different qubit modalities being considered for quantum computing each have their strengths and weaknesses, making it challenging to compare their performance relative to each other and the state-of-the-art in classical high-performance computing. To better understand the utility of a given quantum processor and to assess when and how it will be able to advance the frontiers of computational science, researchers need a robust approach to quantum benchmarking. A variety of approaches have been proposed, many of which characterize the presence of noise in current quantum devices. These efforts include component-level performance metrics, such as randomized benchmarking and gate set tomography; high-level application-dependent metrics; and devicelevel metrics, such as the Quantum Volume. However, it remains unclear how low-level metrics, such as fidelities and decoherence times, and global device metrics, such as Quantum Volume, relate to the computational utility and practical limitations of quantum processors to solve useful problems. In this paper, we describe our Hamiltonian-oriented approach to quantum benchmarking called HamPerf. Where previous application-dependent approaches specify a suite of benchmarking circuits inspired by applications, we place the problem Hamiltonian at the center. Our strategy allows us to probe the computational performance of a quantum processor on standardized and relevant problem sets, agnostic of the algorithms and hardware used to solve them; it also provides fundamental insights into how device characteristics correlate with computational utility.

Butko, Anastasiia↗

PHOTOMETRIC AND SPECTROSCOPIC STUDIES OF MASSIVE BINARIES IN THE LARGE MAGELLANIC CLOUD. I. INTRODUCTION AND ORBITS FOR TWO DETACHED SYSTEMS: EVIDENCE FOR A MASS DISCREPANCY?

The stellar mass-luminosity relation is poorly constrained by observations for high-mass stars. We describe our program to find eclipsing massive binaries in the Magellanic Clouds using photometry of regions rich in massive stars, and our spectroscopic follow-up to obtain radial velocities and orbits. Our photometric campaign identified 48 early-type periodic variables, of which only 15 (31%) were found as part of the microlensing surveys. Spectroscopy is now complete for 17 of these systems, and in this paper we present analysis of the first two, LMC 172231 and ST2-28, simple detached systems of late-type O dwarfs of relatively modest masses. Our orbit analysis yields very precise masses ({approx}2%), and we use tomography to separate the components and determine effective temperatures by model fitting, necessary for determining accurate (0.05-0.07 dex) bolometric luminosities in combination with the light-curve analysis. Our approach allows more precise comparisons with evolutionary theory than previously possible. To our considerable surprise, we find a small, but significant, systematic discrepancy: all of the stars are slightly undermassive, by typically 11% (or overluminous by 0.2 dex) compared with that predicted by the evolutionary models. We examine our approach for systematic problems, but find no satisfactory explanation. The discrepancy is in the same sense as the long-discussed and elusive discrepancy between the masses measured from stellar atmosphere analysis with the stellar evolutionary models, and might suggest that either increased rotation or convective overshooting is needed in the models. Additional systems will be discussed in future papers of this series, and will hopefully confirm or refute this trend.

79 ASTRONOMY AND ASTROPHYSICS↗

Universal framework for simultaneous tomography of quantum states and SPAM noise

We present a general denoising algorithm for performing simultaneous tomography of quantum states and measurement noise. This algorithm allows us to fully characterize state preparation and measurement (SPAM) errors present in any quantum system. Our method is based on the analysis of the properties of the linear operator space induced by unitary operations. Given any quantum system with a noisy measurement apparatus, our method can output the quantum state and the noise matrix of the detector up to a single gauge degree of freedom. We show that this gauge freedom is unavoidable in the general case, but this degeneracy can be generally broken using prior knowledge on the state or noise properties, thus fixing the gauge for several types of state-noise combinations with no assumptions about noise strength. Such combinations include pure quantum states with arbitrarily correlated errors, and arbitrary states with block independent errors. This framework can further use available prior information about the setting to systematically reduce the number of observations and measurements required for state and noise detection. Our method effectively generalizes existing approaches to the problem, and includes as special cases common settings considered in the literature requiring an uncorrelated or invertible noise matrix, or specific probe states.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-C-204-04: Patient Specific Proton Stopping Powers Estimation by Combining Proton Radiography and Prior-Knowledge X-Ray CT Information

Purpose: The material relative stopping power (RSP) uncertainty is the highest contributor to the range uncertainty in proton therapy. The purpose of this work is to develop a robust and systematic method that yields accurate, patient specific, RSP by combining 1) pre-treatment x-ray CT and 2) daily proton radiograph of the patient. Methods: The method is formulated as a linear least-square optimization problem (min||Ax-B||2). The parameter A represents the pathlength crossed by the proton in each material. The RSPs for the materials (water equivalent thickness (WET)/physical thickness) are denoted by x. B is the proton radiograph expressed as WET crossed. The problem is minimized using a convex-conic optimization algorithm with xi<xi+1 constraint. The Gammex RMI-465 phantom, with 13 material inserts, is used to investigate the optimal RSPs. The proton radiograph (B) is produced using Geant4 simulation. The matrix A is computed by calculating proton trajectories through the CT with the cubic-spline approach. Geant4 RSPs are used as reference and the clinical HU-RSP calibration curve is used as comparison. The convergence is investigated as a function of the number of angles and protons used. The radiographs angle which yield the most accurate RSPs are investigated. Results: Optimization with 9 angles and 104 protons/angle yields precise RSP (<0.75%) for all materials, except plastic lung (1.5%). Average deviation relative to Geant4 RSP is 0.5% and 3.5% using HU-RSP. Using more than two angles or more than 4×103 proton does not further increase the RSP estimate accuracy. The insert distance to the beam initial plane is related to the RSP error for this insert material. Specific filters are applied on the proton angle and energy loss to remove nuclear interaction artefacts. Conclusion: The proposed formulation of the problem with prior knowledge x-ray CT demonstrates serious potential to increase the accuracy of present RSP estimates.

60 APPLIED LIFE SCIENCES↗

Fast compressed sensing-based CBCT reconstruction using Barzilai-Borwein formulation for application to on-line IGRT

Purpose: Compressed sensing theory has enabled an accurate, low-dose cone-beam computed tomography (CBCT) reconstruction using a minimal number of noisy projections. However, the reconstruction time remains a significant challenge for practical implementation in the clinic. In this work, we propose a novel gradient projection algorithm, based on the Gradient-Projection-Barzilai-Borwein formulation (GP-BB), that handles the total variation (TV)-norm regularization-based least squares problem for the CBCT reconstruction in a highly efficient manner, with speed acceptable for routine use in the clinic. Methods: CBCT is reconstructed by minimizing an energy function consisting of a data fidelity term and a TV-norm regularization term. Both terms are simultaneously minimized by calculating the gradient projection of the energy function with the step size determined using an approximate Hessian calculation at each iteration, based on the Barzilai-Borwein formulation. To speed up the process, a multiresolution optimization is used. In addition, the entire algorithm was designed to run with a single graphics processing unit (GPU) card. To evaluate the performance, the Shepp-Logan numerical phantom, the CatPhan 600 physical phantom, and a clinically-treated head-and-neck patient were acquired from the TrueBeam system (Varian Medical Systems, Palo Alto, CA). For each scan, in total, 364 projections were acquired in a 200 deg. rotation. The imager has 1024 x 768 pixels with 0.388 x 0.388-mm resolution. This was down-sampled to 512 x 384 pixels with 0.776 x 0.776-mm resolution for reconstruction. Evenly spaced angles were subsampled and used for varying the number of projections for the image reconstruction. To assess the performance of our GP-BB algorithm, we have implemented and compared with three compressed sensing-type algorithms, the two of which are popular and published (forward-backward splitting techniques), and the other one with a basic line-search technique. In addition, the conventional Feldkamp-Davis-Kress (FDK) reconstruction of the clinical patient data is compared as well. Results: In comparison with the other compressed sensing-type algorithms, our algorithm showed convergence in {<=}30 iterations whereas other published algorithms need at least 50 iterations in order to reconstruct the Shepp-Logan phantom image. With the CatPhan phantom, the GP-BB algorithm achieved a clinically-reasonable image with 40 projections in 12 iterations, in less than 12.6 s. This is at least an order of magnitude faster in reconstruction time compared with the most recent reports utilizing GPU technology given the same input projections. For the head-and-neck clinical scan, clinically-reasonable images were obtained from 120 projections in 34-78 s converging in 12-30 iterations. In this reconstruction range (i.e., 120 projections) the image quality is visually similar to or better than the conventional FDK reconstructed images using 364 projections. This represents a dose reduction of nearly 67% (120/364 projections) while maintaining a reasonable speed in clinical implementation. Conclusions: In this paper, we proposed a novel, fast, low-dose CBCT reconstruction algorithm using the Barzilai-Borwein step-size calculation. A clinically viable head-and-neck image can be obtained within {approx}34-78 s while simultaneously cutting the dose by approximately 67%. This makes our GP-BB algorithm potentially useful in an on-line image-guided radiation therapy (IGRT).

62 RADIOLOGY AND NUCLEAR MEDICINE↗