Search NASA⌕ Search

SEARCH · Search NASA

Results for “tomography problems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Multi-Resolution Seismic Tomography Based on Recursive Tessellation Hierarchy

A 3-D global tomographic model that reconstructs velocity structure at multiple scales and incorporates laterally variable seismic discontinuities is currently being developed. The model parameterization is node-based where nodes are placed along vertices defined by triangular tessellations of a spheroidal surface. The triangular tessellation framework is hierarchical. Starting with a tetrahexahedron representing the whole globe (1st level of the hierarchy, 24 faces), they divide each triangle of the tessellation into daughter triangles. The collection of all daughter triangles comprises the 2nd level of the tessellation hierarchy and further recursion produces an arbitrary number of tessellation levels and arbitrarily fine node-spacing. They have developed an inversion procedure that takes advantage of the recursive properties of the tessellation hierarchies by progressively solving for shorter wavelength heterogeneities. In this procedure, we first perform the tomographic inversion using a tessellation level with coarse node spacing. They find that a coarse node spacing of approximately 8{sup o} is adequate to capture bulk regional properties. They then conduct the tomographic inversion on a 4{sup o} tessellation level using the residuals and inversion results from the 8{sup o} run. In practice they find that the progressive tomography approach is robust, providing an intrinsic regularization for inversion stability and avoids the issue of predefining resolution levels. Further, determining average regional properties with coarser tessellation levels enables long-wavelength heterogeneities to account for sparsely sampled regions (or regions of the mantle where longer wavelength patterns of heterogeneity suffice) while allowing shorter length-scale heterogeneities to emerge where necessary. They demonstrate the inversion approach with a set of synthetic test cases that mimic the complex nature of data arrangements (mixed-determined inversion) common to most tomographic problems. They also apply the progressive inversion approach with Pn waves traveling within the Middle East region and compare the results to simple tomographic inversions. As expected from synthetic testing, the progressive approach results in detailed structure where there is high data density and broader regional anomalies where seismic information is sparse. The ultimate goal is to use these methods to produce a seamless, multi-resolution global tomographic model with local model resolution determined by the constraints afforded by available data. They envisage this new technique as the general approach to be employed for future multi-resolution model development with complex arrangements of regional and teleseismic information.

58 GEOSCIENCES↗

Microfluidic technology platforms for synthesizing, labeling and measuring the kinetics of transport and biochemical reactions for developing molecular imaging probes

Radiotracer techniques are used in environmental sciences, geology, biology and medicine. Radiotracers with Positron Emission Tomography (PET) provided biological examinations of ~3 million patients 2008. Despite the success of positron labeled tracers in many sciences, there is limited access in an affordable and convenient manner to develop and use new tracers. Integrated microfluidic chips are a new technology well matched to the concentrations of tracers. Our goal is to develop microfluidic chips and new synthesis approaches to enable wide dissemination of diverse types of tracers at low cost, and to produce new generations of radiochemists for which there are many unfilled jobs. The program objectives are to: 1. Develop an integrated microfluidic platform technology for synthesizing and 18F-labeling diverse arrays of different classes of molecules. 2. Incorporate microfluidic chips into small PC controlled devices (“Synthesizer”) with a platform interfaced to PC for electronic and fluid input/out control. 3. Establish a de-centralized model with Synthesizers for discovering and producing molecular imaging probes, only requiring delivery of inexpensive [18F]fluoride ion from commercial PET radiopharmacies vs the centralized approach of cyclotron facilities synthesizing and shipping a few different types of 18F-probes. 4. Develop a position sensitive avalanche photo diode (PSAPD) camera for beta particles embedded in a microfluidic chip for imaging and measuring transport and biochemical reaction rates to valid new 18F-labeled probes in an array of cell cultures. These objectives are met within a research and educational program integrating radio-chemistry, synthetic chemistry, biochemistry, engineering and biology in the Crump Institute for Molecular Imaging. The Radiochemistry Training Program exposes PhD and post doctoral students to molecular imaging in vitro in cells and microorganisms in microfluidic chips and in vivo with PET, from new technologies for radiochemistry (macro to micro levels), biochemistry and biology to imaging principles, tracer kinetics, pharmacokinetics and biochemical assays. New generations of radiochemists will be immersed in the biochemistry and biology for which their labeled probes are being developed for assays of these processes. In this program engineers and radio-chemists integrate the principles of microfluidics and radiolabeling along with proper system design and chemistry rule sets to yield Synthesizers enabling biological and pharmaceutical scientists to develop diverse arrays of probes to pursue their interests. This progression would allow also radiochemists to focus on the further evolution of rapid, high yield synthetic reactions with new enabling technologies, rather than everyday production of radiotracers that should be done by technologists. The invention of integrated circuits in electronics established a platform technology that allowed an evolution of ideas and applications far beyond what could have been imagined at the beginning. Rather than provide a technology for the solution to a single problem, it is hoped that microfluidic radiochemistry will be an enabling platform technology for others to solve many problems. As part of this objective, another program goal is to commercialize the technologies that come from this work so that they can be provided to others who wish to use it.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Pebble Fuel Handling and Reactivity Control for Salt-Cooled High Temperature Reactors

This report documents the work completed on the X-PREX facility under NEUP Project 11- 3172. This project seeks to demonstrate the viability of pebble fuel handling and reactivity control for fluoride salt-cooled high-temperature reactors (FHRs). The research results also improve the understanding of pebble motion in helium-cooled reactors, as well as the general, fundamental understanding of low-velocity granular flows. Successful use of pebble fuels in with salt coolants would bring major benefits for high-temperature reactor technology. Pebble fuels enable on-line refueling and operation with low excess reactivity, and thus simpler reactivity control and improved fuel utilization. If fixed fuel designs are used, the power density of salt- cooled reactors is limited to 10 MW/m 3 to obtain adequate duration between refueling, but pebble fuels allow power densities in the range of 20 to 30 MW/m 3 . This can be compared to the typical modular helium reactor power density of 5 MW/m3. Pebble fuels also permit radial zoning in annular cores and use of thorium or graphite pebble blankets to reduce neutron fluences to outer radial reflectors and increase total power production. Combined with high power conversion efficiency, compact low-pressure primary and containment systems, and unique safety characteristics including very large thermal margins (>500°C) to fuel damage during transients and accidents, salt-cooled pebble fuel cores offer the potential to meet the major goals of the Advanced Reactor Concepts Development program to provide electricity at lower cost than light water reactors with improved safety and system performance.This report presents the facility description, experimental results, and supporting simulation methods of the new X-Ray Pebble Recirculation Experiment (X-PREX), which is now operational and being used to collect data on the behavior of slow dense granular flows relevant to pebble bed reactor core designs. The X-PREX facility uses novel digital x-ray tomography methods to track both the translational and rotational motion of spherical pebbles, which provides unique experimental results that can be used to validate discrete element method (DEM) simulations of pebble motion. The validation effort supported by the X-PREX facility provides a means to build confidence in analysis of pebble bed configuration and residence time distributions that impact the neutronics, thermal hydraulics, and safety analysis of pebble bed reactor cores. Experimental and DEM simulation results are reported for silo drainage, a classical problem in the granular flow literature, at several hopper angles. These studies include conventional converging and novel diverging geometries that provide additional flexibility in the design of pebble bed reactor cores. Excellent agreement is found between the X-PREX experimental and DEM simulation results. This report also includes results for additional studies relevant to the design and analysis of pebble bed reactor cores including the study of forces on shut down blades inserted directly into a packed bed and pebble flow in a cylindrical hopper that is representative of a small test reactor.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Realizing controllable depolarization in photonic quantum-information channels

Controlling the depolarization of light is a long-standing open problem. In recent years, many demonstrations have used the polarization of single photons to encode quantum information. The depolarization of these photons is equivalent to the decoherence of the quantum information they encode. We present schemes for building various depolarizing channels with controlled properties using birefringent crystals. Three such schemes are demonstrated, and their effects on single photons are shown by quantum process tomography to be in good agreement with a theoretical model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Roll Compaction of Powdered Radioactive Wastes - 18251

Most of low- and intermediate-level radioactive wastes must be solidified by a proper binding matrix and disposed at the centralized disposal site. So it is desirable to achieve a high loading of radwastes in a drum to reduce the disposal fee while meeting both the national regulations and the waste acceptance criteria of the disposal site. In general, the radioactive wastes (liquid, dried powder and sludge) were solidified by mixing with a proper binding matrix (cement, polymer, asphalt, etc.), but their solidified volume inevitably increases due to the limitation of incorporating of radwaste into a binding matrix. To solve this problem, some Korean NPPs operate both a CTS (Concentrate Treatment System, evaporation and granulation) and a polymer solidification system. The size distribution of granulated wastes produced by CTS is so broad (diameter; several μm ∼ several cm) that a polymer cannot impregnate the void space between particles due to their small size. However, if the powdered radwaste can be compacted into high density pellets, and the pellets can be loaded in a drum with maximum waste loading, then the binding matrix can fill the void between pellets, it might be more desirable to keep the size distribution of pellets constant to reduce the solidified waste volume. This compaction methodology can greatly reduce the disposal fee due to the reduction of the solidified waste volume, and can facilitate polymer solidification due to the constant size of the radwaste pellets. This methodology is also applicable to solidify powdered wastes such a depleted uranium used as a catalyst, ash and sludge. Loading radwaste compacted with bentonite pellets versus particles into a container serves, as an engineered or natural barrier in a deep geologic disposal system. Roll compaction is a typical agglomeration process for dry powders and depends on the device parameters and the material properties. This study, firstly, was focused on the design of roll compactor (briquetting machine), the shape and size of pellet, and secondly the loading method of pellets into a drum, their solidification in polymer, and evaluating the overall volume reduction. We used bentonite (particle size; 85 ∼ 100 μm) as a material to be compacted instead of radwaste powders (concentrates and depleted uranium wastes) without the addition of agglomeration agents. In the design of roll, we considered the diameter (200 mm) and width (41 mm) of roll, two types of pocket shapes (< 9 mm, 0.275 ml), and the surface of the pocket. Fig. 2 shows two pellet shapes, tetragonal and circular. The pressure of roll compactor, one of the main process variables, is > 320 kg f/cm{sup 2}, and the roll gap is 0.5 mm. The powders are compacted in a compaction zone between two counter-rotating rolls according to the complicated mechanisms. As a result of the state and the apparent density of the pellets obtained by changing the pressure from 0 to 286 kg f/cm{sup 2}, the pellets were unstable at pressure=0, but above 148 kg f/cm{sup 2} the pellets were more stable, and the apparent density of the pellets was 2.63 g/cm{sup 3} at 148 kg f/cm{sup 3}, and 2.68 g/cm{sup 3} at 286 kg f/cm{sup 2}. The roller speed (rpm) can determine the capacity (kg/h) of a compactor, and depends on both the compaction pressure and the feeding rate. By increasing the roll speed from 2 to 4 rpm, the apparent density of pellets was decreased gradually from 2.74 g/cm{sup 3} to 1.45 g/cm{sup 3}. We designed the special feeding system in order to feed powders uniformly to the roll gripping zone and to supply powders into the narrowest part of the roll gap. At a constant roll speed (3 rpm) and a constant compaction pressure (286 kg f/cm{sup 2}), the apparent density of the pellets was linearly proportional to the feeding rate from 2.18 to 2.74 g/cm{sup 3} by changing the feeding rate of powders from 8 to 12 rpm. In the polymer solidification of the obtained pellets, we used epoxy resin as a solidification agent, and showed their solidified waste forms in Fig. 5. The incorporation ratio (wt.%) of powders/polymer was about 71.7/28.3 in tetragonal pellets, 71.9/28.1 in circular pellets. We calculated the volume reduction in an aspect of powders itself and the solidified waste form. In powder case, through the comparison of the apparent density of the obtained pellets (2.74 g/cm{sup 3}) and raw powders (0.93 g/cm{sup 3}), the volume reduction was calculated as about 2.74/0.93 = 2.95 times. This means that powders can be compacted to 1/2.95 times. And in waste form case, the weight ratio of powder/polymer in a mixing method (workable) and a compaction method is about 0.42, 2.56, individually. Therefore the volume reduction was calculated as about 2.56/0.42 = 6.01 times. We found a compaction methodology for the volume reduction of powdered radioactive wastes, and their polymer solidification will be more effective to reduce the volume of radwastes to be disposed. After a characterization of the solidified waste form incorporated pellets (including sintered pellets), this methodology will be applied to treat depleted uranium wastes used as catalyst, and to solve the problem of NPPs' polymer solidification system, as mentioned above. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tomographic Sparse View Selection Using the View Covariance Loss

Standard computed tomography (CT) reconstruction algorithms such as filtered back projection (FBP) and Feldkamp-Davis-Kress (FDK) require many views for producing high-quality reconstructions, which can slow image acquisition and increase cost in non-destructive evaluation (NDE) applications. Over the past 20 years, a variety of methods have been developed for computing high-quality CT reconstructions from sparse views. However, the problem of how to select the best views for CT reconstruction remains open. In this paper, we present a novel view covariance loss (VCL) function that measures the joint information of a set of views by approximating the normalized mean squared error (NMSE) of the reconstruction. We present fast algorithms for computing the VCL along with an algorithm for selecting a subset of views that approximately minimizes its value. Our experiments on simulated and measured data indicate that for a fixed number of views our proposed view covariance loss selection (VCLS) algorithm results in reconstructions with lower NRMSE, fewer artifacts, and greater accuracy than current alternative approaches.

Lin, Jingsong [Purdue University]↗

Information content of and the ability to reconstruct dichroic X-ray tomography and laminography

Dichroic tomography is a 3D imaging technique in which the polarization of the incident beam is used to induce contrast due to the magnetization or orientation of a sample. The aim is to reconstruct not only the optical density but the dichroism of the sample. The theory of dichroic tomographic and laminographic imaging in the parallel-beam case is discussed as well as the problem of reconstruction of the sample’s optical properties. The set of projections resulting from a single tomographic/laminographic measurement is not sufficient to reconstruct the magnetic moment for magnetic circular dichroism unless additional constraints are applied or data are taken at two or more tilt angles. For linear dichroism, three polarizations at a common tilt angle are insufficient for unconstrained reconstruction. However, if one of the measurements is done at a different tilt angle than the other, or the measurements are done at a common polarization but at three distinct tilt angles, then there is enough information to reconstruct without constraints. Possible means of applying constraints are discussed. Furthermore, it is shown that for linear dichroism, the basic assumption that the absorption through a ray path is the integral of the absorption coefficient, defined on the volume of the sample, along the ray path, is not correct when dichroism or birefringence is strong. This assumption is fundamental to tomographic methods. An iterative algorithm for reconstruction of linear dichroism is demonstrated on simulated data.

Marcus, Matthew A. (ORCID:0000000325277586)↗

A deep learning approach for semantic segmentation of unbalanced data in electron tomography of catalytic materials

In computed TEM tomography, image segmentation represents one of the most basic tasks with implications not only for 3D volume visualization, but more importantly for quantitative 3D analysis. In case of large and complex 3D data sets, segmentation can be an extremely difficult and laborious task, and thus has been one of the biggest hurdles for comprehensive 3D analysis. Heterogeneous catalysts have complex surface and bulk structures, and often sparse distribution of catalytic particles with relatively poor intrinsic contrast, which possess a unique challenge for image segmentation, including the current state-of-the-art deep learning methods. To tackle this problem, we apply a deep learning-based approach for the multi-class semantic segmentation of a γ-Alumina/Pt catalytic material in a class imbalance situation. Specifically, we used the weighted focal loss as a loss function and attached it to the U-Net’s fully convolutional network architecture. We assessed the accuracy of our results using Dice similarity coefficient (DSC), recall, precision, and Hausdorff distance (HD) metrics on the overlap between the ground-truth and predicted segmentations. Our adopted U-Net model with the weighted focal loss function achieved an average DSC score of 0.96 ± 0.003 in the γ-Alumina support material and 0.84 ± 0.03 in the Pt NPs segmentation tasks. We report an average boundary-overlap error of less than 2 nm at the 90th percentile of HD for γ-Alumina and Pt NPs segmentations. The complex surface morphology of γ-Alumina and its relation to the Pt NPs were visualized in 3D by the deep learning-assisted automatic segmentation of a large data set of high-angle annular dark-field (HAADF) scanning transmission electron microscopy (STEM) tomography reconstructions.

36 MATERIALS SCIENCE↗

Orbital angular momentum in phase space

Research Highlights: > We propose a comprehensive Weyl-Wigner formalism for the canonical pair angle-angular momentum. > We present a simple and useful toolkit for the practitioner. > We derive simple evolution equations in terms of a star product in the semiclassical limit. - Abstract: A comprehensive theory of the Weyl-Wigner formalism for the canonical pair angle-angular momentum is presented. Special attention is paid to the problems linked to rotational periodicity and angular-momentum discreteness.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A BrachyPhantom for verification of dose calculation of HDR brachytherapy planning system

Purpose: To develop a calibration phantom for {sup 192}Ir high dose rate (HDR) brachytherapy units that renders possible the direct measurement of absorbed dose to water and verification of treatment planning system.Methods: A phantom, herein designated BrachyPhantom, consists of a Solid Water™ 8-cm high cylinder with a diameter of 14 cm cavity in its axis that allows the positioning of an A1SL ionization chamber with its reference measuring point at the midheight of the cylinder's axis. Inside the BrachyPhantom, at a 3-cm radial distance from the chamber's reference measuring point, there is a circular channel connected to a cylindrical-guide cavity that allows the insertion of a 6-French flexible plastic catheter from the BrachyPhantom surface. The PENELOPE Monte Carlo code was used to calculate a factor, P{sub sw}{sup lw}, to correct the reading of the ionization chamber to a full scatter condition in liquid water. The verification of dose calculation of a HDR brachytherapy treatment planning system was performed by inserting a catheter with a dummy source in the phantom channel and scanning it with a CT. The CT scan was then transferred to the HDR computer program in which a multiple treatment plan was programmed to deliver a total dose of 150 cGy to the ionization chamber. The instrument reading was then converted to absorbed dose to water using the N{sub gas} formalism and the P{sub sw}{sup lw} factor. Likewise, the absorbed dose to water was calculated using the source strength, S{sub k}, values provided by 15 institutions visited in this work.Results: A value of 1.020 (0.09%, k= 2) was found for P{sub sw}{sup lw}. The expanded uncertainty in the absorbed dose assessed with the BrachyPhantom was found to be 2.12% (k= 1). To an associated S{sub k} of 27.8 cGy m{sup 2} h{sup −1}, the total irradiation time to deliver 150 cGy to the ionization chamber point of reference was 161.0 s. The deviation between the absorbed doses to water assessed with the BrachyPhantom and those calculated by the treatment plans and using the S{sub k} values did not exceed ±3% and ±1.6%, respectively.Conclusions: The BrachyPhantom may be conveniently used for quality assurance and/or verification of HDR planning system with a priori threshold level to spot problems of 2% and ±3%, respectively, and in the long run save time for the medical physicist.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Vector tomography for reconstructing electric fields with non-zero divergence in bounded domains

In vector tomography (VT), the aim is to reconstruct an unknown multi-dimensional vector field using line integral data. In the case of a 2-dimensional VT, two types of line integral data are usually required. These data correspond to integration of the parallel and perpendicular projection of the vector field along the integration lines and are called the longitudinal and transverse measurements, respectively. In most cases, however, the transverse measurements cannot be physically acquired. Therefore, the VT methods are typically used to reconstruct divergence-free (or source-free) velocity and flow fields that can be reconstructed solely from the longitudinal measurements. In this paper, we show how vector fields with non-zero divergence in a bounded domain can also be reconstructed from the longitudinal measurements without the need of explicitly evaluating the transverse measurements. To the best of our knowledge, VT has not previously been used for this purpose. In particular, we study low-frequency, time-harmonic electric fields generated by dipole sources in convex bounded domains which arise, for example, in electroencephalography (EEG) source imaging. We explain in detail the theoretical background, the derivation of the electric field inverse problem and the numerical approximation of the line integrals. We show that fields with non-zero divergence can be reconstructed from the longitudinal measurements with the help of two sparsity constraints that are constructed from the transverse measurements and the vector Laplace operator. As a comparison to EEG source imaging, we note that VT does not require mathematical modeling of the sources. By numerical simulations, we show that the pattern of the electric field can be correctly estimated using VT and the location of the source activity can be determined accurately from the reconstructed magnitudes of the field. - Highlights: • Vector tomography is used to reconstruct electric fields generated by dipole sources. • Inverse solutions are based on longitudinal and transverse line integral measurements. • Transverse line integral measurements are used as a sparsity constraint. • Numerical procedure to approximate the line integrals is described in detail. • Patterns of the studied electric fields are correctly estimated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimized Volumetric Scanning for X-Ray Array Sources

Non-destructive evaluation (NDE) is the science and technology of determining non-invasively the internal structure of manufactured parts, objects, and materials. NDE application areas include medicine, industrial manufacturing, military, homeland security, and airport luggage screening. X-ray measurement systems are most widely used because of their ability to image through a wide range of material densities (from human tissue in medical applications to the dense materials of weapon components). Traditional x-ray systems involve a single source and detector system that rotate and/or translate about the object under evaluation. At each angular location, the source projects x-rays through the object. The rays undergo attenuation proportional to the density of the object's constitutive material. The detector records a measure of the attenuation. Mathematical algorithms are used to invert the forward attenuated ray projection process to form images of the object. This is known as computed tomography (CT). In recent years, the single-source x-ray NDE systems have been generalized to arrays of x-ray sources. Array sources permit multiple views of the object with fewer rotations and translations of the source/detector system. The spatially diverse nature of x-ray array sources has the potential of reducing data collection time, reducing imaging artifacts, and increasing the resolution of the resultant images. Most of the existing CT algorithms were not derived from array source models with a spatially diverse set of viewing perspectives. Single-source x-ray CT data collection, processing, and imaging methods and algorithms are not applicable when the source location is expanded from one dimension (a rotating and/or translating point source) to two (a rotating and/or translating array). They must be reformulated. The goal of this project is to determine the applicability of x-ray array sources to problems of interest to LLNL and its customers. It is believed array source data collection will be faster while yielding higher resolution reconstructions with fewer artifacts. There are three tasks in the research: (1) Develop forward array source analytic and computational models; (2) Research and develop array source reconstruction algorithms; and (3) Perform experiments.

42 ENGINEERING↗

Machine learning for detection of 3D features using sparse x-ray tomographic reconstruction

In many inertial confinement fusion (ICF) experiments, the neutron yield and other parameters cannot be completely accounted for with one and two dimensional models. This discrepancy suggests that there are three dimensional effects that may be significant. Sources of these effects include defects in the shells and defects in shell interfaces, the fill tube of the capsule, and the joint feature in double shell targets. Due to their ability to penetrate materials, x rays are used to capture the internal structure of objects. Methods such as computational tomography use x-ray radiographs from hundreds of projections, in order to reconstruct a three dimensional model of the object. In experimental environments, such as the National Ignition Facility and Omega-60, the availability of these views is scarce, and in many cases only consists of a single line of sight. Mathematical reconstruction of a 3D object from sparse views is an ill-posed inverse problem. These types of problems are typically solved by utilizing prior information. Neural networks have been used for the task of 3D reconstruction as they are capable of encoding and leveraging this prior information. We utilize half a dozen, different convolutional neural networks to produce different 3D representations of ICF implosions from the experimental data. Deep supervision is utilized to train a neural network to produce high-resolution reconstructions. These representations are used to track 3D features of the capsules, such as the ablator, inner shell, and the joint between shell hemispheres. Machine learning, supplemented by different priors, is a promising method for 3D reconstructions in ICF and x-ray radiography, in general.

Wolfe, Bradley T. (ORCID:0000000268301614)↗

Enhancing Biopreparedness through a Model System to Understand the Molecular Mechanisms that Lead to Pathogenesis and Disease Transmission: NW-BRaVE

The science of biopreparedness to counter biological threats hinges on understanding the fundamental principles and molecular mechanisms that lead to pathogenesis and disease transmission. Our vision to address this challenge is to create a powerful and user-friendly platform to elucidate the fundamental principles of how molecular interactions drive pathogen-host relationships and host shifts. We will enable groundbreaking discoveries by integrating a wide range of structural, genomics, proteomics, and other advanced omics measurements, along with evolutionary and artificial intelligence predictions. To make sure the system is applicable to real-world problems, we will develop it in the context of a tractable model system, the small, abundant, and accessible photosynthetic cyanobacteria and their constantly co-adapting viral pathogens, cyanophages. This model will maintain the system’s applicability to real-world problems and techniques, but the overall focus will be on elucidating general principles of detecting, assessing, and surveilling molecular interaction, adaptation, and coevolution that are system agnostic and therefore extensible to other viral-host interactions. Our overall objectives are to (1) identify the molecular complexes that comprise the cyanobacteria redox macromolecular subsystem and how they dynamically change with bacteriophage infection in situ, using cryo-electron tomography; (2) profile regulatory changes during infection using proteomics, multiomics, and experimental validation, and integrate the data with in situ structures; (3) use genomics and metagenomics to determine environmental and population factors across time scales that impact the interactions between marine cyanobacteria and their cyanophage parasites, predicting the evolutionary origins of in situ structural and functional interactions, convergence and coevolution; and (4) develop a data integration and transformation platform that facilitates the integration of in situ, proteomic, and evolutionary measurements of molecular interactions to surveil diverse hosts and parasites in various environmental contexts. These objectives address Focus Area 2 Reveal Molecular Interactions Across Biological Scales for Design of Targeted Interventions. Our powerful and user-friendly platform will enhance connections between the often-siloed fields of structure, molecular phenotype, and evolutionary genomics that are key to biopreparedness, but in need of integration (Figure 1). We will build an integrated navigation tool to facilitate the effective use of globally distributed experimental data for integrated analysis and predictive modeling. The project will develop, implement, and test a platform to assess host-pathogen molecular interactions, adaptation to hosts and host shifts, and coevolution between hosts and pathogens, successfully impacting the research community by revolutionizing abilities to study any host-pathogen interaction, encourage diverse community contributions, and gain fundamental insights into how proteins adapt to new contexts. This ability will be critical for designing early interventions to address future threats. We will build surveillance training capability, aiming for a fair and equitable response to future pandemics and biothreats.

59 BASIC BIOLOGICAL SCIENCES↗

3D Characterization and Time-Lapse Imaging of the Desiccation Treatability Test at the Hanford BC-Cribs and Trenches Site using High Performance Electrical Resistivity Imaging

Contaminated vadose zone materials are a potential source of long-term groundwater contamination at many sites across the Department of Energy (DOE) complex. Deep vadose zone contamination presents a particularly challenging remedial problem due to the difficultly of locating contaminants and the expense of access and ex situ treatment. In situ remediation techniques, whereby remedial amendments must be delivered to contaminated soils, have been identified as a potential alternative. However, amendment delivery is typically uncertain and post delivery remedial performance is often not well understood due to limited information available from sparsely spaced boreholes. Recent advancements in electrical resistivity tomography (ERT) are being used to address these challenges at the Hanford site by providing remote, three-dimensional images of contaminant distribution and four-dimensional (three spatial dimensions plus the time dimension) images of in-situ vadose zone remediation processes. These capabilities were recently demonstrated with a large scale surface characterization effort and during a smaller scale desiccation treatability test at the Hanford BC-Cribs area. The results of these efforts demonstrate the utility of leveraging high-performance computing resources to process ERT data for 3D reconnaissance mapping of subsurface contaminants and for detailed 3D monitoring of vadose zone remediation efforts.

contamination↗

3D Characterization and Time-Lapse Imaging of the Desiccation Treatability Test at the Hanford BC-Cribs and Trenches Site using High Performance Computing applied to Electrical Resistivity Imaging - 12271

Contaminated vadose zone materials are a potential source of long-term groundwater contamination at many sites across the Department of Energy (DOE) complex. Deep vadose zone contamination presents a particularly challenging remedial problem due to the difficultly of locating contaminants and the expense of access and ex situ treatment. In situ remediation techniques, whereby remedial amendments must be delivered to contaminated soils, have been identified as a potential alternative. However, amendment delivery is typically uncertain and post delivery remedial performance is often not well understood due to limited information available from sparsely spaced boreholes. Recent advancements in electrical resistivity tomography (ERT) are being used to address these challenges at the Hanford site by providing remote, three-dimensional images of contaminant distribution and four-dimensional (three spatial dimensions plus the time dimension) images of in-situ vadose zone remediation processes. These capabilities were recently demonstrated with a large scale surface characterization effort and during a smaller scale desiccation treatability test at the Hanford BC-Cribs area. The results of these efforts demonstrate the utility of leveraging high-performance computing resources to process ERT data for 3D reconnaissance mapping of subsurface contaminants and for detailed 3D monitoring of vadose zone remediation efforts. Two examples of ERT imaging at a former waste disposal facility have been demonstrated at different scales; a large scale reconnaissance survey spanning many hundreds of meters and a detailed monitoring application spanning a few tens of meters. Although ERT is applicable at many scales, resolution is generally governed by proximity to electrodes. For instance, the BCCT reconnaissance survey demonstrated herein lost resolution with depth (i.e. away from surface electrodes), and was unable to detect a high conductivity anomaly at approximately 75 m below ground surface in the cribs area; the deep anomalies were detected during highly focused borehole sampling. Conversely, the desiccation site characterization and monitoring demonstrated high resolution at a small scale, but only because of close proximity to survey electrodes. Although proximity to electrodes is not the only factor governing ERT resolution, it is often the primary factor for determining how an ERT system should be effectively deployed for a given application. Regardless of resolution limitations, the utility of ERT for remotely detecting wastes and monitoring subsurface processes is evident. ERT imaging is not a final detection or monitoring solution alone, but provides a necessary capability to remotely detect subsurface conditions and understand subsurface processes. Such a capability can significantly increase the efficacy and reduce the cost of remediation by guiding sampling efforts and informing remedial system design and operation. However, given the computational demands of 3D ERT characterization and monitoring inversions, the full imaging capability enabled by contemporary ERT survey systems can generally only be realized with high performance computing resources, both hardware and software. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-F-P-04: Implementation of Dose Monitoring Software: Successes and Pitfalls

Purpose: to successfully install a dose monitoring software (DMS) application to assist in CT protocol and dose management. Methods: Upon selecting the DMS, we began our implementation of the application. A working group composed of Medical Physics, Radiology Administration, Information Technology, and CT technologists was formed. On-site training in the application was supplied by the vendor. The decision was made to apply the process for all the CT protocols on all platforms at all facilities. Protocols were painstakingly mapped to the correct masters, and the system went ‘live’. Results: We are routinely using DMS as a tool in our Clinical Performance CT QA program. It is useful in determining the effectiveness of revisions to existing protocols, and establishing performance baselines for new units. However, the implementation was not without difficulty. We identified several pitfalls and obstacles which frustrated progress. Including: Training deficiencies, Nomenclature problems, Communication, DICOM variability. Conclusion: Dose monitoring software can be a potent tool for QA. However, implementation of the program can be problematic and requires planning, organization and commitment.

60 APPLIED LIFE SCIENCES↗

Quantitative 3D petrography using X-ray tomography 2: Combining information at various resolutions

X-ray tomography is a nondestructive technique that can be used to study rocks and other materials in three dimensions over a wide range of sizes. Samples that range from decimeters to micrometers in size can be analyzed, and micrometer- to centimeter-sized crystals, vesicles, and other particles can be identified and quantified. In many applications, quantification of a large spectrum of sizes is important, but this cannot be easily accomplished using a single tomogram due to a common trade-off between sample size and image resolution. This problem can be circumvented by combining tomograms acquired for a single sample at a variety of resolutions. We have successfully applied this method to obtain crystal size distributions (CSDs) for magnetite, pyroxene + biotite, and quartz + feldspar in Bishop Tuff pumice. Five cylinders of systematically varying size (1-10 mm diameter and height) were analyzed from each of five pumice clasts. Cylinder size is inversely proportional to image resolution, such that resolution ranges from 2.5 to 17 {micro}m/voxel with increasing sample size. This allows quantification of crystals 10-1000 {micro}m in size. We obtained CSDs for each phase in each sample by combining information from all resolutions, each size bin containing data from the resolution that best characterizes crystals of that size. CSDs for magnetite and pyroxene + biotite in late-erupted Bishop pumice obtained using this method are fractal, but do not seem to result from crystal fragmentation. CSDs for quartz + feldspar reveal a population of abundant crystals <35 {micro}m in size, and a population of crystals >50 {micro}m in size, which will be the focus of a separate publication.

58 GEOSCIENCES↗