Search NASA⌕ Search

SEARCH · Search NASA

Results for “total”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Calculation of total electron excitation cross-sections and partial electron ionization cross-sections for the elements

Computer programs were used to calculate the total electron excitation cross-section for atoms and the partial ionization cross-section. The approximations to the scattering amplitude used are as follows: (1) Born, Bethe, and Modified Bethe for non-exchange excitation; (2) Ochkur for exchange excitation; and (3) Coulomb-Born of non-exchange ionization. The amplitudes are related to the differential cross-sections which are integrated to give the total excitation (or partial ionization) cross-section for the collision. The atomic wave functions used are Hartree-Fock-Slater functions for bound states and the coulomb wave function for the continuum. The programs are presented and the results are examined.

Green, T. J.↗

Cosmic ray isotope resolution obtained using a new Cerenkov-total energy telescope

The details of a recent measurement of the cosmic ray isotopic composition of Z equals or exceeds 10 nuclei are given, using a new technique combining a Cerenkov and total energy counter. In terms of sigma, the characteristic width of a Gaussian distribution of mass measurement, values of mass resolution have been obtained ranging from about 0.4 AMU at a Z about 14, to about 0.8 AMU at a Z about 26, using the Cerenkov-total energy (C x E) technique. It is customary to claim that two equal Gaussian distributions may be resolved for values of sigma less than 0.4 x the separation of their means. With these criteria isotopes separated by delta A = 2 are being resolved up to a Z about 26 using the C x E technique. An important source of error in these measurements is the determination of the mass of each of the isotopes on an absolute scale.

Webber, W. R.↗

Near-earth magnetic disturbance in total field at high latitudes. I - Summary of data from Ogo 2, 4, and 6. II - Interpretation of data from Ogo 2, 4, and 6

A complete survey of the near-earth magnetic field magnitude was carried out by the Polar Orbiting Geophysical Observatories (Ogo 2, 4, and 6). The average properties of variations in total magnetic field strength at invariant latitudes greater than 55 deg are given. Data from all degrees of magnetic disturbance are included, the emphasis being on periods when Kp = 2- to 3+. Although individual satellite passes at low altitudes confirm the existence of electrojet currents, neither individual satellite passes nor contours of average delta B are consistent with latitudinally narrow electrojet currents as the principal source of delta B at the satellite. The total field variations at the satellite form a region of positive delta B between about 2200 and 1000 MLT and a region of negative delta B between about 1000 and 2200 MLT. The ratio of delta B magnitudes in these positive and negative regions is variable.

Langel, R. A.↗

Inviscid interpenetration of two streams with unequal total pressures

A theory is proposed for analyzing the inviscid interpretation of two streams in the case when the difference in total pressure between the streams is relatively small. A stream is considered which discharges from a nozzle or reservoir into a partially moving and partially stationary environment in such a way that the flows leave the solid boundaries in a tangential direction where the two streams first interact. The problem is solved by expanding in a small parameter related to the difference in total pressure between the streams, the zeroth-order solution is obtained by classical methods, and a technique similar to that employed in thin-airfoil theory is used to transfer the first-order boundary conditions to the zeroth-order boundary. A procedure is developed to transform the problem into one that can be solved by standard techniques of the theory of sectionally analytic functions. Solutions are obtained for flows with and without free streamlines, and the general theory is applied to several specific flow configurations.

Goldstein, M. E.↗

A simple total energy sensor

This research concerns a simple technique for total energy compensation having the primary requirement of good compensation with a low cost, easy to make sensor. A comprehensive library search and a small wind tunnel were used to explore fundamentals and to develop a number of probes which were flight tested with satisfactory results. Simple probe configurations were tested using the characteristics of laminar flow separation around a small cylinder to produce a sensor pressure having the desired relationship between static and dynamic pressures. Wind tunnel and flight tests confirmed the concepts for a wide range of speeds, altitudes, and flow directions encountered in soaring. Data and findings are presented, along with a discussion of factors important to total energy compensation.

Nicks, O. W.↗

Irradiate-anneal screening of total dose effects in semiconductor devices

An extensive investigation of irradiate-anneal (IRAN) screening against total dose radiation effects was carried out as part of a program to harden the Mariner Jupiter/Saturn 1977 (MJS'77) spacecraft to survive the Jupiter radiation belts. The method consists of irradiating semiconductor devices with Cobalt-60 to a suitable total dose under representative bias conditions and of separating the parts in the undesired tail of the distribution from the bulk of the parts by means of a predetermined acceptance limit. The acceptable devices are then restored close to their preirradiation condition by annealing them at an elevated temperature. IRAN was used when lot screen methods were impracticable due to lack of time, and when members of a lot showed a diversity of radiation response. The feasibility of the technique was determined by testing of a number of types of linear bipolar integrated circuits, analog switches, n-channel JFETS and bipolar transistors. Based on the results of these experiments a number of device types were selected for IRAN of flight parts in the MJS'77 spacecraft systems. The part types, screening doses, acceptance criteria, number of parts tested and rejected as well as the program steps are detailed.

Stanley, A. G.↗

Short period oscillations in total electron content

The paper describes measurements of fluctuations in the total electron content along the propagation path of the radio beam between the ATS-6 geostationary satellite and the ground station. Short-period oscillations of the total electron content of about plus or minus 8 time 10 to the 13th electrons per sq m with a period of about 30 to 50 seconds were detected. These oscillations appear to be well correlated with the appearance of Type PC 4 micropulsations.

Davies, K.↗

Short-period fluctuations in total columnar electron content

Small sinusoidal fluctuations in the total columnar electron content of the atmosphere were found in recordings of the carrier phase of radio signals from ATS 6 received at Bozeman (Montana), Boulder (Colorado) and Dallas (Texas). Four such events are examined. A large latitudinal gradient in total electron content was found from Bozeman to Boulder. The sinusoidal oscillations have periods of 30 to 50 sec and may continue for several hours on magnetically quiet days. There is evidence that they are associated with micropulsations at ground and geostationary heights.

Davies, K.↗

Inlet total pressure loss due to acoustic wall treatment

The effect of diffuser wall acoustic treatment on inlet total pressure loss was experimentally determined. Data were obtained by testing an inlet model with 10 different acoustically treated diffusers differing only in the design of the Helmholtz resonator acoustic treatment. Tests were conducted in a wind tunnel at forward velocities to 41 meters per second for inlet throat Mach numbers of .5 to .8 and angles of attack as high as 50 degrees. Results indicate a pressure loss penalty due to acoustic treatment that increases linearly with the porosity of the acoustic facing sheet. For a surface porosity of 14 percent the total pressure loss was 21 percent greater than that for an untreated inlet.

Miller, B. A.↗

Inlet total pressure loss due to acoustic wall treatment

Experimental determination of the effect of diffuser wall acoustic treatment on inlet total pressure loss. Data were obtained by testing an inlet model with 10 different acoustically treated diffusers differing only in the design of the Helmholtz resonator acoustic treatment. Tests were conducted in a wind tunnel at forward velocities to 41 meters per second for inlet throat Mach numbers of .5 to .8 and angles of attack as high as 50 degrees. Results indicate a pressure loss penalty due to acoustic treatment that increases linearly with the porosity of the acoustic facing sheet. For a surface porosity of 14% the total pressure loss was 21% greater than that for an untreated inlet. The penalty resulting from treatment increased for average throat Mach numbers above approximately .7 where local regions of sonic or supersonic surface flow were encountered. Pressure loss over the treatment was not affected by the presence of noise.

Miller, B. A.↗

First comparison of simultaneous IRIS, BUV, and ground-based measurements of total ozone

In the present paper, the zonally-averaged global distribution of total ozone obtained simultaneously from different measurements are compared with respect to differences in the measured latitudinal and seasonal variations of total ozone. Emphasis is placed on systematic discrepancies that appear to be related to differences in the sensing methodologies or instruments. While the zonal averages of the IRIS and BUV satellite techniques agree quite well at low latitudes, the results are consistently higher for IRIS than for BUV above mid-latitudes in both the Northern and Southern Hemispheres. The BUV and ground-based ultraviolet averages agree better with each other than with infrared IRIS measurements.

Prior, E. J.↗

The effect of surface reflection and clouds on the estimation of total ozone from satellite measurements

The total amount of ozone in a vertical column is being measured by Nimbus 4 and 7 observations of the intensity of ultraviolet sunlight scattered from the earth. The algorithm for deriving the amount of ozone from the observations uses the assumption that the surface reflects the light isotropically and the albedo is independent of wavelength. The effects of anisotropic surfaces and clouds on the estimate of total ozone are computed for models of the earth-atmosphere system.

Fraser, R. S.↗

Onset of condensation effects as detected by total pressure probes in the Langley 0.3-meter transonic cryogenic tunnel

Total pressure probes mounted in the test section of a 0.3 meter transonic cryogenic tunnel were used to detect the onset of condensation effects for free stream Mach numbers of 0.50, 0.75, 0.85, and 0.95 and for total pressure between one and five atmospheres. The amount of supercooling was found to be about 3 K and suggests that condensation was occurring on pre-existing liquid nitrogen droplets resulting from incomplete evaporation of the liquid nitrogen injected to cool the tunnel. The liquid nitrogen injection process presently being used for the 0.3 m tunnel was found to result in a wide spectrum of droplet sizes being injected into the flow. Since the relatively larger droplets took much more time to evaporate than the more numerous smaller droplets, the larger ones reached the test section first as the tunnel operating temperature was reduced. However, condensation effects in the test section were not immediately measurable because there was not a sufficient number of the larger droplets to have an influence on the thermodynamics of the flow.

Hall, R. M.↗

The global distribution of long-term total ozone variations during the period 1957-1975

Total ozone observations in the international network have been used as a basis for the analysis of the mean monthly ozone distribution over the globe for the period 1957-1975. It has been found that during the period 1961-1970 the total ozone amount increased in the Northern Hemisphere by about 12 percent and that this increase seems to be significant at all latitudes. Although the data were sparse for the Southern Hemisphere, there did not appear to be any significant ozone changes during the 10 year period. Relatively large geographic variations were found in the ozone trends and it is suggested that these variations are related to large scale changes in the atmospheric circular pattern.

London, J.↗

Total electron content and F-region electron density distribution near the magnetic equator in India

Total electron content derived from the group delay measurements of ATS-6 radio beacons received at Ootacamund (India) are compared with the electron-density vs height distributions derived from the ionosonde data of the nearby station Kodaikanal. The daily variation of equivalent vertical total electron content does not show the midday bite out which is so prominently present in the corresponding daily variation of the maximum F-region electron density. The topside electron content continues to increase from sunrise to a maximum value around 1500 LT, while the bottomside electron content reaches a maximum value around 0500 LT. Daily variations of these as well as other parameters, e.g. the vertical slab thickness, the bottomside semi-thickness, the height of the F2 peak have been also studied for a geomagnetically quiet and a disturbed day.

Rastogi, R. G.↗

Utilization of 100 mb midlatitude height fields as an indicator of sampling effects on total ozone variations

Midlatitude 100-mb height fields are employed to determine the effects of ground based sampling locations on measurements of variations in the total ozone content of the atmosphere. The precision of the zonal average heights computed by the technique of Angell and Korshover (1978) from data over ozone sampling areas at 50 deg N is compared to the zonal average computed from the entire data set. Linear regressions of ozone contents determined by an analysis of backscatter UV satellite data with respect to 100 mb heights are utilized to transform zonal differences in height to ozone levels. The zonal average total ozone sampling error is found to be on the order of 2% for midlatitudes of the Northern hemisphere, indicating that the general shape of ozone trends determined by ground-based observations appears to be real and the increase of ozone from the mid-1960's to the early 1970's may be greater than previously suggested.

Miller, A. J.↗

Remote sensing of total dry-matter accumulation in winter wheat

The author has identified the following significant results. Red and photographic-infrared spectral data collected on 21 dates over the growing season with a hand-held radiometer was quantitatively correlated with total dry-matter accumulation in winter wheat. The spectral data were found to be highly related to vigor and condition of the plant canopy. Two periods of drought stress and subsequent recovery from it were readily apparent in the spectral data. Simple ratios of the spectral data compensated for variations in solar intensities and, when integrated over the growing season, explained 79% of the variation in total above-ground accumulation of dry matter.

Tucker, C. J.↗

Solar activity and total atmospheric ozone

Analyses are presented of the association between two parameters of solar activity (Lyman-alpha and 10.7 cm flux) and global total ozone as determined from Nimbus observations for the period April-December 1970 (IRIS observations), and April 1970-April 1972 (BUV observations); and between Lyman-alpha and global total ozone as observed at ground stations and the ozone concentration in the lower and middle stratosphere in the subtropics for the period 1969-1972. It is shown that the high correlations discussed in other published studies between these solar paramters and nine months of IRIS data resulted from the use of a very limited, seasonally unfiltered data set.

London, J.↗