Search NASA⌕ Search

SEARCH · Search NASA

Results for “total temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Large-Eddy Simulation Study of Flow and Combustion Dynamics in a Full-Scale Hydrogen–Air Rotating Detonation Combustor-Stator Integrated System

In the present work, a first-of-its-kind three-dimensional (3D) large-eddy simulation (LES) study is conducted to numerically investigate the combustion dynamics as well as aero-thermal phenomena in a full-scale nonpremixed hydrogen–air rotating detonation engine (RDE) (with a diverging-shaped lower-end wall), when integrated with nozzle guide vanes (NGV) acting as the turbine stator. The wall-modeled LES framework incorporates hydrogen–air detailed chemical kinetics and adaptive mesh refinement (AMR). A comparative analysis is carried out for two operating conditions with different fuel/air mass flow rates but global equivalence ratio of unity, and considering RDE configurations without and with stator. The LES model is validated against available experimental data for the low mass flux condition with respect to detonation wave speed/height, wave dynamics, and axial static pressure distribution. Numerical results indicate significant deflagrative combustion occurring in the fill region near the inner wall due to formation of recirculation zones in the injection near-field driven by the backward facing step. The leading detonation wave is found to be trailed by an azimuthal reflected-shock combustion (ARSC) wave, consistent with experimental observations, which consumes unburned vitiated reactants that leak through the main detonation wave. The main detonation wave characteristics, such as detonation wave speed/height and combustion efficiency, do not change appreciably with the presence of NGV. A novel combustion diagnostic technique based on chemical explosive mode analysis (CEMA) is employed to quantify the fraction of heat release occurring in the detonative mode versus deflagrative mode for the simulated conditions. The exit flow is found to be nearly fully subsonic and supersonic for the low and high mass flux conditions, respectively. Further analysis of the exit flow profiles shows that the presence of NGV renders the flow more axial and significantly impacts the exit Mach number and total pressure, while the total temperature shows negligible change. In addition, the low mass flux operating point, despite exhibiting more deflagrative losses within the combustor, yields overall lower pressure drop from plenum to exhaust, which is mainly attributed to lower pressure drop across the injectors. Lastly, the rotating detonation engine-nozzle guide vanes (RDE-NGV) configuration exhibits higher total pressure loss compared to rotating detonation engine (RDE) without stator across both the mass flux conditions. In conclusion, this study extends the state-of-the-art in numerical modeling of pressure gain combustion (PGC) systems by demonstrating high-fidelity 3D reacting LES of full-scale RDE-NGV systems relevant to RDE-turbine integration for stationary power generation.

Combustion↗

Coupling conditions for integrating boundary layer and rotational inviscid flow

The matching of a boundary layer and a rotational inviscid flow is reexamined by extending the Johnson and Sockol (1979) coupling conditions to include the case where the boundary layer solution includes the second-order effects of the freestream vorticity and the total temperature gradient. It is pointed out that two of the three conditions are not independent. If the boundary layer solution satisfies the appropriate momentum and energy integral equations, it follows that the imposition of the normal mass flux condition insures that the conditions on a normal flux of streamwise momentum and total enthalpy will also be satisfied.

Sockol, P. M.↗

Drag Force Anemometer Used in Supersonic Flow

To measure the drag on a flat cantilever beam exposed transversely to a flow field, the drag force anemometer (beam probe) uses strain gauges attached on opposite sides of the base of the beam. This is in contrast to the hot wire anemometer, which depends for its operation on the variation of the convective heat transfer coefficient with velocity. The beam probe retains the high-frequency response (up to 100 kHz) of the hot wire anemometer, but it is more rugged, uses simpler electronics, is relatively easy to calibrate, is inherently temperature compensated, and can be used in supersonic flow. The output of the probe is proportional to the velocity head of the flow, 1/2 rho u(exp 2) (where rho is the fluid density and u is the fluid velocity). By adding a static pressure tap and a thermocouple to measure total temperature, one can determine the Mach number, static temperature, density, and velocity of the flow.

Fralick, Gustave C.↗

Effects of jet exhaust gas properties on exhaust simulation and afterbody drag

The effect of varying the jet exhaust's ratio of specific heats, gas constant, and temperature on airplane afterbody drag was investigated. Jet exhaust simulation parameters were evaluated also. Subsonic and transonic tests were made using a single nacelle model with afterbodies having boattail angles of 10 deg and 20 deg. Besides air, three other jet exhaust gases were investigated. The ratios of specific heats, gas constants, and total temperatures of the four exhaust gases ranged from 1.40 to 1.26, 287 to 376 J/kg-K, and 300 to 1013 K, respectively. For steep boattail angles, and transonic speeds and typical turbojet pressure ratios, the current data indicate that the use of air to simulate a dry turbojet exhaust can result in an overprediction of afterbody drag as high as 17 percent of the dry turbojet value.

Compton, W. B., III↗

Performance of a mullite reusable surface insulation system in a hypersonic stream

The thermal and structural performance of a large panel of mullite reusable surface insulation (RSI) tiles was determined by a series of aerothermal tests in the Langley 8-foot high-temperature structures tunnel. The test panel was designed to represent a portion of the surface structure on a space shuttle orbiter fuselage along a 1,150 K isotherm with the mullite tile system bonded directly to the primary structure. Aerothermal tests were conducted at a free-stream Mach number of 6.7, a total temperature of 1,880 K, a unit Reynolds number of 4.6 million per meter, and dynamic pressure of 62 kPa. The thermal response of the mullite tile was as predicted, and the bond-line temperature did not exceed the design level of 570 K during a typical entry-heat cycle. Geometric irregularities of the tile gaps affected the tile edge temperatures when exposed to hypersonic flow. The tile coating demonstrated good toughness to particle impacts, but the coating cracked and flaked with thermal cycles. The gap filler of woven silica fibers appeared to hinder flow penetration into the gaps and withstood the flow shear of the present tests.

Hunt, L. R.↗

General Correlation of Temperature Profiles Downstream of a Heated Air Jet Directed at Various Angles to Air Stream

An experimental investigation was conducted to determine the temperature profiles downstream of heated air jets directed at angles of 90 deg, 60 deg, 45 deg, and 30 deg to an air stream. The profiles were determined at two positions downstream of the jet as a function of jet diameter, jet density, jet velocity, free-stream density, free-stream velocity, jet total temperature, orifice flow coefficient, and jet angle. A method is presented which yields a good approximation of the temperature profile in terms of the flow and geometric conditions.

Ruggeri, Robert S.↗

Mach wave emission from a high-temperature supersonic jet

The paper considers the compressible Rayleigh equation as a model for the Mach wave emission mechanism associated with high-temperature supersonic jets. Solutions to the compressible Rayleigh equation reveal the existence of several families of supersonically convecting instability waves. These waves directly radiate noise to the jet far field. The predicted noise characteristics are compared to previously acquired experimental data for an axisymmetric Mach 2 fully pressure balanced jet operating over a range of jet total temperatures from ambient to 1370 K. The results of this comparison show that the first-order supersonic instability wave and the Kelvin-Hemlhlotz first-, second-, and third-order modes have directional radiation characteristics that are in agreement with observed data. The assumption of equal initial amplitudes for all of the waves leads to the conclusion that the flapping mode of instability dominates the noise radiatio process of supersonic jets. At a jet temperature of 1370 K, supersonic instability waves are predicted to dominate the noise radiated at high frequency at narrow angles to the jet axis.

Seiner, John M.↗

Northern pike bycatch in an inland commercial hoop net fishery: effects of water temperature and net tending frequency on injury, physiology, and survival

In lakes and rivers of eastern Ontario (Canada) commercial fishers use hoop nets to target a variety of fishes, but incidentally capture non-target (i.e., bycatch) gamefish species such as northern pike (Esox lucius). Little is known about the consequences of bycatch in inland commercial fisheries, making it difficult to identify regulatory options. Regulations that limit fishing during warmer periods and that require frequent net tending have been proposed as possible strategies to reduce bycatch mortality. Using northern pike as a model, we conducted experiments during two thermal periods (mid-April: 14.45 ± 0.32 °C, and late May: 17.17 ± 0.08 °C) where fish were retained in nets for 2 d and 6 d. A ‘0 d’ control group consisted of northern pike that were angled, immediately sampled and released. We evaluated injury, physiological status and mortality after the prescribed net retention period and for the surviving fish used radio telemetry with manual tracking to monitor delayed post-release mortality. Our experiments revealed that injury levels, in-net mortality, and post-release mortality tended to increase with net set duration and at higher temperatures. Pike exhibited signs of chronic stress and starvation following retention, particularly at higher temperatures. Total mortality rates were negligible for the 2 d holding period at 14 °C, 14% for 6 d holding at 14 °C, 21% for 2 d holding at 17 °C, and 58% for 6 d holding at 17 °C. No mortality was observed in control fish. Collectively, these data reveal that frequent net tending, particularly at warmer temperatures, may be useful for conserving gamefish populations captured as bycatch in inland hoop net fisheries.

discards↗

Mach wave emission from a high temperature supersonic jet

The paper considers the compressible Rayleigh equation as a model for the Mach wave emission mechanism associated with high temperature supersonic jets. Solutions to the compressible Rayleigh equation reveal the existence of several families of supersonically convecting instability waves. These waves directly radiate noise to the jet far field. The predicted noise characteristics are compared to previously acquired experimental data for an axisymmetric Mach 2 fully pressure balanced jet operating over a range of jet operating total temperatures from ambient to 1370 K. The results of this comparison show that the first order supersonic instability wave and the Kelvin-Helmholtz first, second, and third order modes have directional radiation characteristics that are in agreement with observed data. The assumption of equal initial amplitudes for all of the waves leads to the conclusion that the flapping mode of instability dominates the noise radiation process of supersonic jets. At a jet temperature of 1370 K, supersonic instability waves are predicted to dominate the noise radiated at high frequency at narrow angles to the jet axis.

Seiner, J. M.↗

Heat transfer and pressure measurements for the SSME fuel turbine

A measurement program is underway using the Rocketdyne two-stage Space Shuttle Main Engine (SSME) fuel turbine. The measurements use a very large shock tunnel to produce a short-duration source of heated and pressurized gas which is subsequently passed through the turbine. Within this environment, the turbine is operated at the design values of flow function, stage pressure ratio, stage temperature ratio, and corrected speed. The first stage vane row and the first stage blade row are instrumented in both the spanwise and chordwise directions with pressure transducers and heat flux gages. The specific measurements to be taken include time averaged surface pressure and heat flux distributions on the vane and blade, flow passage static pressure, flow passage total pressure and total temperature distributions, and phase resolved surface pressure and heat flux on the blade.

Dunn, Michael G.↗

EMBEDDED LENSING TIME DELAYS, THE FERMAT POTENTIAL, AND THE INTEGRATED SACHS–WOLFE EFFECT

We derive the Fermat potential for a spherically symmetric lens embedded in a Friedman–Lemaître–Robertson–Walker cosmology and use it to investigate the late-time integrated Sachs–Wolfe (ISW) effect, i.e., secondary temperature fluctuations in the cosmic microwave background (CMB) caused by individual large-scale clusters and voids. We present a simple analytical expression for the temperature fluctuation in the CMB across such a lens as a derivative of the lens’ Fermat potential. This formalism is applicable to both linear and nonlinear density evolution scenarios, to arbitrarily large density contrasts, and to all open and closed background cosmologies. It is much simpler to use and makes the same predictions as conventional approaches. In this approach the total temperature fluctuation can be split into a time-delay part and an evolutionary part. Both parts must be included for cosmic structures that evolve and both can be equally important. We present very simple ISW models for cosmic voids and galaxy clusters to illustrate the ease of use of our formalism. We use the Fermat potentials of simple cosmic void models to compare predicted ISW effects with those recently extracted from WMAP and Planck data by stacking large cosmic voids using the aperture photometry method. If voids in the local universe with large density contrasts are no longer evolving we find that the time delay contribution alone predicts values consistent with the measurements. However, we find that for voids still evolving linearly, the evolutionary contribution cancels a significant part of the time delay contribution and results in predicted signals that are much smaller than recently observed.

79 ASTRONOMY AND ASTROPHYSICS↗

Boundary Layer Transition on Slender Cones in Conventional and Low Disturbance Mach 6 Wind Tunnels

An experimental investigation was conducted on a 5-degree half-angle cone and a 5-degree half-angle flared cone in a conventional Mach 6 wind tunnel to examine the effects of facility noise on boundary layer transition. The influence of tunnel noise was inferred by comparing transition onset locations determined from the present test to that previously obtained in a Mach 6 low disturbance quiet tunnel. Together, the two sets of experiments are believed to represent the first direct comparison of transition onset between a conventional and a low disturbance wind tunnel using a common test model and transition detection technique. In the present conventional hypersonic tunnel experiment, separate measurements of heat transfer and adiabatic wall temperatures were obtained on the conical models at small angles of attack over a range of Reynolds numbers, which resulted in laminar, transitional, and turbulent flow. Smooth model turbulent heating distributions are compared to that obtained with transition forced via discrete surface roughness. The model nosetip radius was varied to examine the effects of bluntness on transition onset. Despite wall to total temperature differences between the transient heating measurements and the adiabatic wall temperature measurement, the two methods for determining sharp cone transition onset generally yielded equivalent locations. In the 'noisy' mode of the hypersonic low disturbance tunnel, transition onset occurred earlier than that measured in the conventional hypersonic tunnel, suggesting higher levels of freestream acoustic radiation relative to the conventional tunnel. At comparable freestream conditions, the transition onset Reynolds number under low disturbance conditions was a factor of 1.3 greater than that measured on flared cone in the LaRC conventional hypersonic tunnel and a factor of 1.6 greater that the flared cone run in the low disturbance tunnel run 'noisy'. Navier-Stokes mean flow computations and linear stability analysis were conducted to assess the experimental results and have indicated N factors associated with sharp flared cone transition onset to be approximately a factor of 2 lower than that inferred from the corresponding low disturbance tunnel measurements.

Horvath, Thomas J.↗

Aerothermal evaluation of a spherically blunted body with a trapezoidal cross section in the Langley 8-foot high-temperature tunnel

A model to be used in the flow studies and curved Thermal Protection System (TPS) evaluations was tested in the Langley 8 Foot High-Temperature Tunnel at a nominal Mach number of 6.8. The purpose of the study was to define the surface pressure and heating rates at high angles of attack (in support of curved metallic TPS studies) and to determine the conditions for which the model would be suitable as a test bed for aerothermal load studies. The present study was conducted at a nominal total temperature of 2400 and 3300 R, dynamic pressures from 2.3 to 10.9 psia, and free-stream Reynolds numbers from 4000,000 to 1,700,000/ft. The measurements consisted primarily of surface pressure and cold-wall (530 R) heating rates. Qualitative comparisons between predictions and data show that for this configuration, aerothermal tests should be limited to angles of attack between 10 and -10 degrees. Outside this range, the effects of free-stream flow nonuniformity appear in the data, as a result of the long length of the model. However, for TPS testing, this is not a concern and tests can be performed at angles of attack ranging from 20 to -20 degrees. Laminar and naturally turbulent boundary layers are available over limited ranges of conditions.

Albertson, Cindy W.↗

Transient temperature distributions in simple conducting bodies steadily heated through a laminar boundary layer

An analysis is made of the transient heat-conduction effects in three simple semi-infinite bodies: the flat insulated plate, the conical shell, and the slender solid cone. The bodies are assumed to have constant initial temperatures and, at zero time, to begin to move at a constant speed and zero angle of attack through a homogeneous atmosphere. The heat input is taken as that through a laminar boundary layer. Radiation heat transfer and transverse temperature gradients are assumed to be zero. The appropriate heat-conduction equations are solved by an iteration method, the zeroeth-order terms describing the situation in the limit of small time. The method is presented and the solutions are calculated to three orders which are sufficient to give reasonably accurate results when the forward edge has attained one-half the total temperature rise (nose half-rise time). Flight Mach number and air properties occur as parameters in the result. Approximate expressions for the extent of the conduction region and nose half-rise times as functions of the parameters of the problem are presented. (author)

Parker, Hermon M↗

Genesis and atomic structure of the charge density wave phase of 1T-VSe 2

Using variable temperature total x-ray scattering, we study the emergence of charge density wave (CDW) order in the archetypal transition-metal dichalcogenide (TMDC) 1⁢𝑇−VSe 2 . Here, we find that a CDW precursor phase (PF) appears at 𝑇 CDW⁡(PF) of 200(5) K, where V and Se atoms experience in- and out-of-plane static displacements from their position in the undistorted lattice, respectively. The displacements increase with decreasing temperature and a little-known superstructure of V triatomic clusters emerges below 𝑇 CDW⁡(3⁢D) of 100(5) K, where three-dimensional CDW order sets in. Concurrently, Se atoms form less well-defined dimers. Thus, similarly to other TMDCs, 1⁢𝑇−VSe 2 appears to exhibit a two-step CDW transition. The finding underlines the key contribution of lattice distortions to the emergence of CDW order in 1⁢𝑇−VSe 2 and generally in TMDCs.

36 MATERIALS SCIENCE↗

Flow Disturbance Characterization Measurements in the National Transonic Facility

Recent flow measurements have been acquired in the National Transonic Facility (NTF) to assess the unsteady flow environment in the test section. The primary purpose of the test is to determine the feasibility of the NTF to conduct laminar-flow-control testing and boundary-layer transition sensitive testing. The NTF can operate in two modes, warm (air) and cold/cryogenic (nitrogen) test conditions for testing full and semispan scaled models. The warm-air mode enables low to moderately high Reynolds numbers through the use of high tunnel pressure, and the nitrogen mode enables high Reynolds numbers up to flight conditions, depending on aircraft type and size, utilizing high tunnel pressure and cryogenic temperatures. NASA's Environmentally Responsible Aviation (ERA) project is interested in demonstrating different laminar-flow technologies at flight-relevant operating conditions throughout the transonic Mach number range and the NTF is well suited for the initial ground-based demonstrations. Roll polar data at selected test conditions were obtained to look at the uniformity of the flow disturbance field in the test section. Data acquired from the rake probes included mean total temperatures, mean and fluctuating static/total pressures, and mean and fluctuating hot-wire measurements. . Based on the current measurements and previous data, an assessment was made that the NTF is a suitable facility for ground-based demonstrations of laminar-flow technologies at flight-relevant conditions in the cryogenic mode.

King, Rudolph A.↗

Local lattice distortions drive the transition of BaIrO 3 into a ferromagnetic insulator state

Using variable temperature total and resonant x-ray scattering at the K edge of Ir species, we study the “bad metal” to insulator transition in BaIrO 3 , a canonical third transition series oxide. The usage of advanced experimental techniques and large-scale computer modeling helps us show that, contrary to the widely accepted view, charge disproportionation leading to the formation of Ir-trimers with a different number of 5d valence electrons already exists at room temperature. The charge disbalance between the trimers does not evolve much with decreasing temperature while local lattice distortions do, suggesting that the latter and not the former make a key contribution to the emergence of the enigmatic ferromagnetic insulator state of BaIrO 3 . The conclusion is supported by DFT calculations based on unmodified experimental structure data. Our work calls for a reconsideration of the role of lattice distortions in determining the electronic properties of third transition series oxides. It also charts a path to assessing these properties on a realistic and not assumed crystal structure basis.

36 MATERIALS SCIENCE↗

Increased capabilities of the Langley Mach 7 Scramjet Test Facility

An experimental research program which explored the potential for expanding the operating range of NASA Langley's Mach 7 Scramjet Test Facility is described. The facility uses electric arc-heated air as the test gas and is configured for testing airframe-integrated scramjet engine models at conditions duplicating flight velocities and temperatures. Previous scramjet testing in this facility was limited to a single simulated flight condition of Mach 6.9 at 115,300 ft. altitude. The present arc heater research demonstrated that the facility can be used for scramjet testing at simulated flight conditions from Mach 4 (at altitudes from 77,000 to 114,000 ft.) to Mach 7 (at altitudes from 108,000 to 149,000 ft.). Flow quality was established from the uniformity of measured total temperature profiles. In addition, nitrogen oxide levels in the test stream were determined for relating engine test data to expected flight performance. The test frequency and reliability of the facility were also improved by a novel redesign of the heater downstream electrode and by defining limits for stable arc operation.

Thomas, S. R.↗