Home charging for all: Techno-economic and life cycle assessment of multi-unit dwelling electric vehicle charging hubs

Ubiquitous electric vehicle adoption can drastically reduce greenhouse gas emissions (GHG) but will require equitable home charging infrastructure for all residences. Unlike single-family homes, Multi-Unit Dwellings (MUD) currently lack market share and access to nearby charging infrastructure partly due to expensive capital costs for reluctant residential property-owners. Further, this work evaluates the levelized cost of charging (LCOC) for Battery Electric Vehicles (BEVs) at MUD community charging hubs through a techno-economic analysis (TEA) that leverages real-world charging data and costs. Three different MUD charging types are investigated for a baseline and optimistic case: 1.9-kW Level 1 (L1), 6.6-kW Level 2 (L2), and 50-kW Direct Current Fast Charging (DCFC) stations under three different ownership models: resident, utility, and private company. Results demonstrate L1 and L2 chargers to be less expensive than the gasoline equivalent across the United States. Further, utility and private company ownership models, which avoid initial costs for residential property owners, result in a large LCOC premium for L1 and moderate LCOC premium for L2 relative to the resident ownership model. In contrast, DCFC is shown to be expensive for baseline scenarios but economical for optimistic scenarios especially under private company ownership. This work also performs a cradle to grave (C2G) life cycle assessment (LCA) of an average passenger BEV and gasoline conventional vehicle (CV) using yearly (grid mix & vehicle parameters), hourly (grid mix), and state-level (grid mix) resolution. Results show BEVs to have lower GHG emissions (-86% to-10%) than gasoline CVs in the contiguous U.S. Next, the system boundary of the TEA is extended to the total cost of ownership (TCO) of BEVs. The TCO is then coupled with the C2G GHG emissions to calculate the cost of GHG emissions reduction. Ultimately, the cost of GHG emissions reduction from MUD BEVs relative to gasoline CVs is shown to be negative for every scenario except baseline DCFC, meaning MUD BEV charging infrastructure can be a cost-effective endeavor to reduce GHG emissions.

33 ADVANCED PROPULSION SYSTEMS↗

Multiscale petrophysical characterization and flow unit classification of the Minnelusa eolian sandstones

Integration of petrophysical and geological information is critical to simulation of subsurface carbon storage (GCS). In this sense, two depositional facies were identified from the core description and well-log interpretation, namely massive (MS) and cross-bedded (CB) facies groups. Additionally, pore-scale characteristics were studied by a combination of techniques, e.g. Nuclear Magnetic Resonance (NMR) and mercury intrusion capillary pressure (MICP). Scanning electron microscope (SEM) and petrographic analyses show that the pore structure is dominantly controlled by the depositional environment and dolomite cementation. NMR-T 2 distributions of MS and CB facies show triple and quadruple modes, respectively. In addition, MICP of high- and low-permeability MS facies samples, and their CB facies group mixtures were collected. The MS sample pore-throat size distribution is uni-modal, while the triple-modal characteristic of the mixtures indicates heterogeneous pore structures at the sub-core scale for CB facies. The reliably estimates of porosity and permeability for both facies groups via NMR techniques and the MLR (Multiple Linear Regression) approach demonstrate the applicability of these techniques to eolian sandstone. Moreover, irreducible water saturation via the T 2 -cutoff method correlates strongly with T 2LM instead of porosity. Finally, the rock quality index and flow zone indicator were calculated based on Combinable Magnetic Resonance (CMR) log interpretations. This provides direct connection to properties measured in the well. Four flow units were classified for both facies groups. Finally, results show that better reservoir quality with significant heterogeneities is observed in the CB facies. This study highlights the importance integrating multiscale petrophysical properties including facies, pore architecture and diagenesis analysis with core- to log-scale property characterization. The results herein validate our reservoir characterization and flow unit classification in eolian reservoirs.

58 GEOSCIENCES↗

Decision support for United States—Canada energy integration is impaired by fragmentary environmental and electricity system modeling capacity

The renewable energy transition is leading to increased electricity trade between the United States and Canada, with Canadian hydropower providing firm lower-carbon power and buffering variability of wind and solar generation in the U.S. However, long-term power purchase agreements and transborder transmission projects are controversial, with two of four proposed transmission lines between Quebec, Canada and the northeast U.S. cancelled since 2018. Here, we argue that controversies are exacerbated by a lack of open-source data and tools to understand tradeoffs of new hydropower generation and transmission infrastructure in comparison to alternatives. This gap includes impacts that incremental transmission and generation projects have on the economics of the entire system, for example, how new transmission projects affect exports to existing markets or incentivize new generation. We identify priority areas for data synthesis and model development, such as integrating linked hydropower and hydrologic interactions in energy system models and openly releasing (by utilities) or back-calculating (by researchers) hydropower generation and operational parameters. Publicly available environmental (e.g. streamflow, precipitation) and techno-economic (e.g. costs, reservoir size,) data can be used to parameterize freely usable and extensible models. Existing models have been calibrated with operational data from Canadian utilities that are not publicly available, limiting the range of scientific and commercial questions these tools have been used to answer and the range of parties that have been involved. Studies conducted using highly resolved, national-scale public data exist in other countries, notably, the United States, and demonstrate how greater transparency and extensibility can drive industry action. Improved data availability in Canada could facilitate approaches that (1) increase participation in decarbonization planning by a broader range of actors; (2) allow independent characterizations of environmental, health, and economic outcomes of interest to the public; and (3) identify decarbonization pathways consistent with community values.

13 HYDRO ENERGY↗

Application of sulfur SAD to small crystals with a large asymmetric unit and anomalous substructure

The application of sulfur single-wavelength anomalous dispersion (S-SAD) to determine the crystal structures of macromolecules can be challenging if the asymmetric unit is large, the crystals are small, the size of the anomalously scattering sulfur structure is large and the resolution at which the anomalous signals can be accurately measured is modest. Here, as a study of such a case, approaches to the SAD phasing of orthorhombic Ric-8A crystals are described. The structure of Ric-8A was published with only a brief description of the phasing process [Zeng et al. (2019), Structure , 27 , 1137–1141]. Here, alternative approaches to determining the 40-atom sulfur substructure of the 103 kDa Ric-8A dimer that composes the asymmetric unit are explored. At the data-collection wavelength of 1.77 Å measured at the Frontier micro-focusing Macromolecular Crystallography (FMX) beamline at National Synchrotron Light Source II, the sulfur anomalous signal strength, |Δ ano |/σΔ ano ( d ′′/sig), approaches 1.4 at 3.4 Å resolution. The highly redundant, 11 000 000-reflection data set measured from 18 crystals was segmented into isomorphous clusters using BLEND in the CCP 4 program suite. Data sets within clusters or sets of clusters were scaled and merged using AIMLESS from CCP 4 or, alternatively, the phenix.scale_and_merge tool from the Phenix suite. The latter proved to be the more effective in extracting anomalous signals. The HySS tool in Phenix , SHELXC / D and PRASA as implemented in the CRANK 2 program suite were each employed to determine the sulfur substructure. All of these approaches were effective, although HySS , as a component of the phenix.autosol tool, required data from all crystals to find the positions of the sulfur atoms. Critical contributors in this case study to successful phase determination by SAD included (i) the high-flux FMX beamline, featuring helical-mode data collection and a helium-filled beam path, (ii) as recognized by many authors, a very highly redundant, multiple-crystal data set and (iii) the inclusion within that data set of data from crystals that were scanned over large ω ranges, yielding highly isomorphous and highly redundant intensity measurements.

59 BASIC BIOLOGICAL SCIENCES↗

Developing Frequency Stability Constraint for Unit Commitment Problem Considering High Penetration of Renewables

As zero-carbon electricity systems become the trend of future grid, the system inertia provided by conventional synchronous generators (SGs) keeps decreasing. The resultant lower system inertia will inevitably cause frequency stability problem, especially in the first few seconds following disturbance. To tackle this challenge, this paper proposes a frequency stability constraint for power systems unit commitment problem by considering the fast frequency responses (FFRs) from inverter-based resources (IBRs). Our developed frequency stability constraint is grounded on an analytical frequency nadir estimation framework that considers both SG and IBR dynamics. The accuracy of our frequency nadir estimation framework is validated by most severe N-1 contingency simulation result in a real island system. Then, the adaptive inertia frequency stability constraint is derived by performing sensitivity analysis with our frequency nadir estimation framework. Finally, we demonstrate the effectiveness of our developed frequency stability constraint with one year day-ahead unit commitment results of the island system.

fast frequency response↗

Harmonics and Stability Evaluation of Converter-Interfaced Combined Heat and Power Units

Grid integration of medium-sized combined heat and power (CHP) units is challenging due to strict grid codes and conventional generators lack of control flexibility to meet these grid codes. Adding a two-stage ac-dc-ac power electronics interface between the generator and the utility grid will accelerate the interconnection process of CHP units. For the dc-ac stage, a voltage source converter (VSC) has been widely used as a grid-tied inverter because of its fast control and low total harmonics distortion (THD). In this paper, several topologies of generator-side rectifiers for ac-dc power conversion are explored and analyzed. The harmonics impact of various rectifiers on the CHP generator are evaluated. The overall cost of the electrical system, when using various types of rectifiers, is assessed and the VSC back-to-back converter interface configuration is found to be optimal. The overall system stability is also examined using small-signal impedance analysis to assess potential instability issues at the system level.

CHP, Harmonics, Generator Rectifier Unit, DC Imped↗

Encoding Frequency Constraints in Preventive Unit Commitment Using Deep Learning With Region-of-Interest Active Sampling

With the increasing penetration of renewable energy, frequency response and its security are of significant concerns for reliable power system operations. Frequency-constrained unit commitment (FCUC) is proposed to address this challenge. Despite existing efforts in modeling frequency characteristics in unit commitment (UC), current strategies can only handle oversimplified low-order frequency response models and do not consider wide-range operating conditions. This paper presents a generic data-driven framework for FCUC under high renewable penetration. Here, deep neural networks (DNNs) are trained to predict the frequency response using real data or high-fidelity simulation data. Next, the DNN is reformulated as a set of mixed-integer linear constraints to be incorporated into the ordinary UC formulation. In the data generation phase, all possible power injections are considered, and a region-of-interest active sampling is proposed to include power injection samples with frequency nadirs closer to the UFLC threshold, which enhances the accuracy of frequency constraints in FCUC. The proposed FCUC is investigated on the IEEE 39-bus system. Then, a full-order dynamic model simulation using PSS/E verifies the effectiveness of FCUC in frequency-secure generator commitments.

42 ENGINEERING↗

Integration of a Microturbine Power Conversion Unit in MAGNET

The Microreactor Agile Non-nuclear Experimental Testbed (MAGNET) facility is being constructed at Idaho National Laboratory’s (INL’s) Energy Systems Laboratory to assist with the development, demonstration, and validation of microreactor components and systems. MAGNET will accommodate various types of test articles representative of different microreactor designs. A power conversion unit (PCU) simulator loop was proposed to use the rejected heat from the test article and mimic the thermal hydraulic conditions (e.g., temperature, pressure and flow rate) that would be experienced if an actual Brayton cycle PCU was attached. However, due to the high-estimated cost of the PCU simulator and the availability of a turbogenerator used for previous testing at Sandia National Laboratories, the PCU simulator design was abandoned in favor of integrating an actual PCU into MAGNET. A commercial Capstone C30 was modified by Sandia to use external electrical heating, rather than combustion heating, to provide a power output from 1 to ~30 kWe. The C30 has a single-stage centrifugal combustor, a static radial heat exchanger, and a radial inflow turbine arranged on a single shaft with a high-speed alternator. Since the operating temperature and energy transfer per unit working fluid mass are comparable, the MAGNET PCU will provide researchers with the ability to evaluate the test article heat transfer under representative operating conditions with the transient system behavior associated with a closed Brayton cycle PCU. This report examines the integration of a modified commercial Capstone C30 turbogenerator into MAGNET, outlines a proposed set of tests, and describes future work.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Low Cost High-Performance HRE-Free 3-in-1 Electric Drive Unit

The project team completed work to expand upon American Axle & Manufacturing’s (AAM) baseline technology and develop a high-speed, AC induction electric drive unit (EDU) with total direct-oil-cooling and integrated power electronics. The project accelerated advancements in EDU technology by allowing AAM to build upon the progress made in developing the underlying baseline technologies. The following seven improvements to AAM’s baseline technology were implemented in this research and development program: 1) Increased speed (30k RPM) AC induction motor, 2) Silver-sintering of discrete silicon carbide (SiC) metal-oxide-semiconductor field-effect transistors (MOSFET) to heat sinks, 3) Electrically insulated rotor bars, 4) Optimized lamination steel, 5) EDU-integrated 650VDC inverter package, 6) Over-molded stator with molded liners, and 7) 650VDC power-dense stator design. The successful development of the technology resulted in a meaningful cost reduction for EDU systems in the market. Coupled with falling battery system costs, lower EDU costs will likely accelerate the market acceptance and related production scaling of battery electric vehicles. The objective of this project was to research, develop, and test a Heavy Rare Earth (HRE)-free 3-In-1 electric drive unit (EDU) that has class leading power density and cost. The key technologies to be developed were anticipated to meet or exceed the Department of Energy (DOE) targets of a cost ≤ $\$$7/kilowatt (kW), power density ≥ 12 kW/liter, and operating voltage ≥ 600 VDC.

33 ADVANCED PROPULSION SYSTEMS↗

Slug Test Characterization Results for the Upper Three Runs Aquifer at the Chemicals, Metals, and Pesticides Pits Operable Unit

Slug tests were performed on 21 wells screened within the Upper Three Runs aquifer (UTRA) at the Chemical, Metals, and Pesticide (CMP) Pits Operable Unit (OU) to determine unit-specific hydraulic properties. The UTRA is the water table aquifer at CMP Pits and is comprised of three discrete zones that are separated by two semi-continuous confining zones. These zones include the transmissive zone (TZ, unconfined), the middle aquifer zone (MAZ, semi-confined), and the lower aquifer zone (LAZ, semi-confined). The LAZ, the most substantial portion of the UTRA in the area, extends vertically to the green clay confining zone (GCCZ). A subset of wells from each zone was selected for slug testing. The objective of the project was to determine hydraulic properties of the three zones of the UTRA for use in future updates to the CMP pits groundwater flow and contaminant transport modeling.

54 ENVIRONMENTAL SCIENCES↗

Notice of Illegal Foreign Pesticides Entering the United States: Information Bulletin v.01

This information bulletin is intended to generate a heightened awareness of illicit pesticide importation, distribution, and use in the United States. This bulletin focuses on solid, fumigant materials which are primarily used in the production of marijuana growth and cultivation. Exposure to illicit pesticides, fumigant fumes, or residual materials may pose a public health and officer safety concern. Many illegal fumigant pesticide products have been seized and determined to consist of a mixture of several pesticides and is often in contrast with the pesticide labelling. This information bulletin is not a complete account of all illegal pesticides found in country; it serves to highlight frequently encountered materials and present patterns in product presentation, packaging, and shipment containment which are intended to aid in identification and intervention. Other varieties of illegal pesticide fumigants are known to exist, and additional variations are expected to be encountered in policing intervention. This bulletin includes information on the presentation of illegal pesticides, label review recommendations, a field reference guide, which includes example photographs of seized pesticide/fumigants and their labels, and related United States federal regulation information, including relevant tariff code information for reference.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Assessment of a reconfiguration of the InterSpread Plus US national FMD model as a potential tool to analyze a foot-and-mouth disease outbreak on a single large cattle feedlot in the United States

An incursion of foot-and-mouth disease (FMD) into the United States remains a concern of high importance and would have devastating socioeconomic impacts to the livestock and associated industries. This highly transmissible and infectious disease poses continual risk for introduction into the United States (US), due to the legal and illegal global movement of people, animals, and animal products. While stamping out has been shown to effectively control FMD, depopulation of large cattle feedlots (>50,000 head) presents a number of challenges for responders due to the resources required to depopulate and dispose of large numbers of animals in a timely and effective manner. However, evaluating alternative strategies for FMD control on large feedlots requires a detailed within-farm modeling approach, which can account for the unique structure of these operations. To address this, we developed a single feedlot, within-farm spread model using a novel configuration within the InterSpread Plus (ISP) framework. As proof of concept we designed six scenarios: (i) depopulation - the complete depopulation of the feedlot, (ii) burn-through – a managed “burn-through” where the virus is allowed to spread through the feedlot and only movement restriction and biosecurity are implemented, (iii) firebreak-NV – targeted depopulation of infected pens and adjacent pens without vaccination; (iv) firebreak - targeted depopulation of infected pens and adjacent pens with vaccination of remaining pens; (v) harvest-NV - selective harvest of pens where a 100% movement restriction is applied for 28-30 days, then pens are set for selection to be sent to slaughter, while allowing a controlled “burn-through” without vaccination; and (vi) harvest - selective harvest of pens with vaccination. Overall, the burn-through scenario (ii) had the shortest epidemic duration (31d (30, 33)) median (25th, 75th percentiles), while the firebreak scenario (iv) had the longest (47d (38,55)). Additionally, we found that scenarios implementing depopulation delayed the peak day of infection and reduced the total number of pens infected compared to non-depopulation scenarios.

60 APPLIED LIFE SCIENCES↗

A Graphics Processing Unit (GPU) Approach to Large Eddy Simulation (LES) for Transport and Contaminant Dispersion

Recent advances in the development of large eddy simulation (LES) atmospheric models with corresponding atmospheric transport and dispersion (AT&D) modeling capabilities have made it possible to simulate short, time-averaged, single realizations of pollutant dispersion at the spatial and temporal resolution necessary for common atmospheric dispersion needs, such as designing air sampling networks, assessing pollutant sensor system performance, and characterizing the impact of airborne materials on human health. The high computational burden required to form an ensemble of single-realization dispersion solutions using an LES and coupled AT&D model has, until recently, limited its use to a few proof-of-concept studies. An example of an LES model that can meet the temporal and spatial resolution and computational requirements of these applications is the joint outdoor-indoor urban large eddy simulation (JOULES). A key enabling element within JOULES is the computationally efficient graphics processing unit (GPU)-based LES, which is on the order of 150 times faster than if the LES contaminant dispersion simulations were executed on a central processing unit (CPU) computing platform. JOULES is capable of resolving the turbulence components at a suitable scale for both open terrain and urban landscapes, e.g., owing to varying environmental conditions and a diverse building topology. In this paper, we describe the JOULES modeling system, prior efforts to validate the accuracy of its meteorological simulations, and current results from an evaluation that uses ensembles of dispersion solutions for unstable, neutral, and stable static stability conditions in an open terrain environment.

54 ENVIRONMENTAL SCIENCES↗

Summertime methane and carbon dioxide emission rates and associated variables from a national-scale survey of 146 reservoirs in the United States, 2016-2023

Reservoirs are globally important sources of greenhouse gases, but the magnitude of their emissions is highly uncertain. Here we present data for 146 reservoirs from two surveys of reservoir methane and carbon dioxide emissions, one at the regional scale in the midwestern United States and one at the national scale in the conterminous United States, plus data from one reservoir in Washington and another in Puerto Rico. At all reservoirs, ebullitive and diffusive emissions and basic physiochemistry were measured at 15-70 locations during one 22 to 64-hour period during the summers of 2016-2023, with four reservoirs revisited a second time. Concomitant water chemistry measurements were also made at an index site. The dataset is comprised of two geospatial files and seven .csv files containing greenhouse gas emissions, water chemistry, morphology, and other relevant data. These data comprise the largest multi-reservoir emissions dataset ever assembled using consistent measurement methods.

Beaulieu, Jake [University of Notre Dame, IN]↗

State-of-the-Art Techniques for Large-Scale Stochastic Unit Commitment

Recent advances in deterministic unit commitment, both formulaic and algorithmic, along with modern algorithmic approaches for stochastic programming, have enabled the solution of stochastic unit commitment problems with hundreds of scenarios on large-scale transmission networks. In this presentation, we will give an overview of these methods, including lazy transmission constraint generation, lower-bounding techniques, and heuristics, all of which can be executed in concert with customized decomposition approaches for optimization under uncertainty. We demonstrate the effectiveness of these techniques on the TAMU Texas7K synthetic transmission network, leveraging realistic high-resolution forecasts based on NREL renewable resource availability data. The software leveraged for these demonstrations is available via the open-source software packages EGRET (for electrical grid optimization) and mpi-sppy (for optimization under uncertainty).

27 ARPA - Advanced Research Projects Agency-Energy↗

Design and Verification of An Open-Circuit Electro-Hydraulic Actuator System with An Integrated Electro-Hydraulic Unit

This paper proposes an electro-hydraulic actuator (EHA) system, and two novel-designed electro-hydraulic units (EHU) consisting of a fixed-displacement hydraulic pump and a variable-speed electric motor. Both the novel EHU designs integrate an electric machine and a hydraulic machine in a single unit, featuring compactness and power density. However, they differ for salient aspects such as power and electric machine cooling system. The EHA system features an open circuit design, where hydraulic hoses connect the EHU with a tank, a valve manifold, and the hydraulic cylinder. In this way, the proposed EHA technology can be used to implement distributed hydraulic actuation in a vehicle without requiring changes to the hydraulic actuators or at the overall layout of the hydraulic components with respect to the original vehicle design. A dedicated test rig is developed to verify the performance of the proposed EHA system. The efficiency of the EHA is measured in a steady state and under a realistic duty cycle of a commercial compact loader. The measured efficiency of the system can reach 54% with up to 20kN load and 6kW power level.

42 ENGINEERING↗

Solving Unit Commitment Problems with Demand Responsive Loads: Preprint

This paper focuses on using variations of the Frank-Wolfe algorithm for solving unit commitment problems with high volumes of demand responsive loads on the power grid. We present a formulation of the unit commitment problem with demand responsive loads. We then show through reformulation and relaxations of the problem that variations of the Frank-Wolfe algorithm can be used to determine the time series decisions for the demand responsive loads. We show through computational experiments on the RTS-GMLC test system that the time series of demand responsive load decisions obtained through our approach are near optimal and provide details regarding how large scale parallel implementations of our approach can be highly computationally efficient.

demand response↗