Search NASA⌕ Search

SEARCH · Search NASA

Results for “utility programs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

SECARB Second Injection Period Reservoir Modeling Report

The Southeast Carbon Sequestration Partnership Phase III Anthropogenic Test at Citronelle Field is the United States’ largest CO 2 capture and transportation, injection, storage and monitoring project using CO 2 derived from a coal-fired power station. The project represents a U.S. Department of Energy research and development initiative designed to demonstrate deep underground injection and containment of 100,000 tonnes or more of anthropogenic-source CO 2 . A series of reservoir modeling runs will be performed during the pre-injection, injection, and post-injection phases of the project and will be used to predict plume migration and areal extent. Pressure, temperature, and downhole measurements (seismic, fluid and logging), all data collected as a part of the monitoring program, are utilized as reservoir performance parameters to tune the existing geophysical and geochemical simulation models.

01 COAL, LIGNITE, AND PEAT↗

Puerto Rico Demand Response Impact and Forecast Tool (PR-DRIFT) - Beta Version [Slides]

Due to high fossil fuel imports, high electricity rates, an unreliable electricity grid, and 100% renewable electricity goals, demand response can play a crucial role for the Puerto Rico electricity grid. The Puerto Rico Demand Response Impact and Forecast Tool (PR-DRIFT) is a spreadsheet-based tool in which users can estimate the potential impacts of demand response, energy efficiency, and VRE and storage adoption in Puerto Rico from 2021 through 2040. The tool includes projections for solar, wind, and battery adoption based on released RFPs and energy targets (including Act-17 2019) to generate a projected net load profile for each hour through 2040. Based on user inputs and default assumptions, the tool also projects load profile impacts of demand response and energy efficiency, and is specifically focused on highlighting projected demand response technical potential. This demand response technical potential can be used by local utilities, regulators, program administrators, or researchers to help design demand response programs for larger impact.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Facilitated Direct Liquid Fuel Cells with High Temperature Membrane Electrode Assemblies

Dimethyl ether (DME) is a liquid fuel of great potential impact due to its exceptionally high energy density. However, it has received minimal prior investigation as an alternative to either purified hydrogen or other liquid fuels, including methanol (MeOH). In the limited published literature work on direct dimethyl ether fuel cells, regardless of operating temperature, PtRu (either supported or unsupported on carbon) has been established as the standard catalyst of choice. The majority of the work in this program also utilized a Johnson Matthey (JM) HiSPEC ® 12100 PtRu/C (nominally 50% Pt, 25% Ru) while looking at electrode optimizations, beginning of life (BoL) performance, pressure- and temperature-dependent studies to look at the effect of binding affinity of DME oxidation intermediates, mass transport effects, crossover studies, and durability. However, it does also investigate some promising alternatives to PtRu/C as well, which should be investigated in more detail in further work. Those catalysts include a pair of ternary PtRuPd/C catalysts (from Los Alamos National Laboratory (LANL) and Pajarito Powder, LLC. (PP)) as well as a Pt 2 Bi Black catalyst from Professor Anastasios Angelopoulos of the University of Cincinnati (UC). This work achieved several project objectives, including an optimization of the membrane electrode assembly (MEA) process using PtRu/C anode catalyst. Additionally, these direct dimethyl ether fuel cells (DDFCs) were able to match or exceed many performance metrics for the state-of-the-art (SOA) direct methanol fuel cells (DMFCs), a primary and more evolved competitor to direct dimethyl ether fuel cells. This included peak specific power, total platinum group metal (PGM) loading, crossover current, degradation rate, start/stop cycling losses, and anode specific current.

09 BIOMASS FUELS↗

Modeling of Reactor Design and Optimization for Scale-Up of the Catalyxx Process for Ethanol Conversion to Higher Alcohol Biofuels

This report summarizes the results of a collaborative efforts between Oak Ridge National Laboratory (ORNL) and Catalyxx Inc. to investigate scale-up of Catalyxx’s Ethanol upgrading to higher alcohols process. The study was funded by the U.S. Department of Energy (DOE) Bioenergy Technologies Office (BETO) under CRADA (Cooperative Research and Development Agreement) No: NFE-20-08396. The project is part of the Direct Funding Opportunity (DFO) for Computational Science to Enable Bioenergy program which utilized computational toolsets developed by the Consortium for Computational Physics and Chemistry, a multi-laboratory consortium in BETO. The report here summarizes a packed-bed reactor modeling effort spanning the range from lab to industrial scale (from 4 gram to 5-ton catalyst beds), and examining reactor design, process optimization strategies, and suggested design and operating conditions for Catalyxx’s ethanol upgrading plants. The results in this report have been shared in monthly steering meetings and presentations are available in the shared data house owned by Catalyxx. The modeling effort helped to define optimum operation conditions for maximum alcohol selectivity and yield: i.e., temperature control scenarios ranging from adiabatic to isothermal, feed rate, pressure, and inlet H 2 /Ethanol ratio. The modeling results were verified at lab-(4 gram) and pre-pilot (4 kg) scales and has been used to evaluate a 5-ton packed-bed reactor and identify operating conditions to maximize the butanol yield. Special focus was given to understanding mass-transfer effects in the pre-pilot and pilot-scale reactors, over the domain of flow rate, pressure, feed composition, pellet size, shape, porosity, bed voidage, and reactor dimensions (i.e., length/diameter). Modeling was also used to evaluate innovative reactor design concepts such as water removal to improve alcohol selectivity and yield, and a reactor with an additional side inlet to facilitate quenching. These concepts were thoroughly explored, and potential benefits were disclosed. The results in this report are summarized and described qualitatively to protect the IP rights of Catalyxx. The details have been shared with the Catalyxx team in the regular steering meetings. At the end of the project, Catalyxx Inc. announced a successful demonstration of pilot scale operation in Seville, Spain.

02 PETROLEUM↗

Demonstrating Load-Shaping Capabilities of Cost Minimizing Heat Pump Water Heater Controls with Varying Price Profiles

Increased penetration of photovoltaics and electrification of traditionally gas appliances are exacerbating existing challenges in cost-effectively balancing electricity grid supply and demand. Decarbonization without incurring expensive transmission and distribution system capacity increases requires shifting building loads from peak demand times to peak renewable production times. Grid operators are evaluating new ways of encouraging load shifting, including using time-varying price structures to provide a financial incentive. If devices incorporate price-responsive controls, a price profile could be designed to yield a wide variety of load curves as needed to optimize grid functionality. Heat pump water heaters (HPWHs) are an ideal device for price-responsive controls because the storage tank enables them to optimize the timing of electricity consumption without impacting hot water delivery service. This paper presents work demonstrating how price-responsive controls for HPWHs can provide different load profiles, as needed to stabilize the grid, in response to different price profiles. HPWH manufacturers now include web API and CTA-2045 communication capabilities which enable sending load shaping control signals. Pilot studies and preliminary programs have utilized these capabilities with uniform control strategies to reduce 4-9 PM electricity consumption. However, no studies have developed flexible controls capable of both a) responding to constantly varying price profiles and b) customizing logic to match the needs of each HPWH. Berkeley Lab's CalFlexHub project is pioneering price-driven load flexibility by developing and deploying cost-minimizing controls utilizing setpoint setting signals for fleets of HPWHs in response to varying price profiles. Control development is based on simulations using the Flexible Heat Pump Water Heater Performance Predictor which captures the control decisions of a residential, integrated HPWH manufacturer’s on-board controller. The proposed cost-reducing controls respond to constantly changing price profiles, providing the ability to change the price profile to generate load curves as needed to maintain grid stability. Preliminary simulations studying the load shaping capabilities of price-responsive controls on a fleet of 60 HPWHs have demonstrated an average of a) 135.4% increases in load during low-price periods, b) >36.8% reductions in electricity peak-price period, and c) 6.2% electricity cost savings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Consumer Benefits of Clean Energy: Energy Efficiency

Meeting national and state decarbonization goals requires a transition to clean energy technologies. Energy efficiency, demand flexibility, renewable energy and storage can reduce consumers’ electricity bills, lower total electricity system costs, and provide health and resilience benefits. Berkeley Lab developed a series of briefs that explore these consumer benefits of a clean energy transition. This brief focuses on energy efficiency benefits, and builds on prior analysis from Berkeley Lab’s Cost of Saved Energy database. We show that energy efficiency remains a low-cost energy and capacity resource; the levelized cost of saving energy for the programs included in the analysis is $\$0.02$/kilowatt-hour and the cost of saving peak demand is less $\$120$/kilowatt. Understanding the impact of the program mix, portfolio size, and duration of implementation for customer-funded energy efficiency portfolios can guide regulatory oversight of these programs, help utilities better utilize energy efficiency as a resource, and inform building energy decarbonization policies.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Blueprint: Coordinated Vulnerability Disclosure (CVD) Adaption and Adoption Guide for Industry To Create Their Own CVD Program

This guide provides a series of steps and guidance for electric vehicle supply equipment (EVSE) industry members to set up their own coordinated vulnerability disclosure (CVD) program by utilizing the Software Engineering Institute/Computer Emergency Response Team (SEI/CERT)’s CVD how-to guide. Due to the complexity of CVD, and with the existing resources out there, this guide is intended that this portion of the blueprint is an extension of the CVD how-to guide, not meant as a replacement. This guide is meant to outline a process for what to do when you discover a vulnerability on EVSE equipment. It is written for developers, vendors and security researchers as well as management. This is not a technical document. It is meant to be accessible for both technical and non-technical roles.

33 ADVANCED PROPULSION SYSTEMS↗

Testing and Analysis of an Exergetically Efficient 4 K to 2 K Helium Heat Exchanger

Modern experimental nuclear physics programs that utilize advanced superconducting devices require refrigeration below the lambda temperature of helium (2.1768 K) and involve sub-atmospheric helium at some point in the process. They typically operate between 1.8 and 2.1 K (16 to 40 mbar) and can require refrigeration ranging from tens to thousands of watts. These processes are very energy intensive, requiring roughly 850 W/W even for large and well?designed refrigerators, though they can easily require much more. Adiabatic expansion of sub-cooled liquid helium to these sub-atmospheric pressures will result in a two-phase mixture with a large liquid to vapor density ratio. Since there are no practical expanders to handle this condition, a counter flow heat exchanger is used to cool the super-critical helium supply using the returning sub-atmospheric helium. Typically, the super-critical helium exiting this 4.5 K to 2-K counter flow heat exchanger is throttled across an expansion valve to a sub-atmospheric pressure. This is a substantial irreversibility, typically 13 percent of the enthalpy difference between the load supply and return. A significant process improvement is theoretically obtainable by handling the exergy loss across the expansion valve supplying the flow to the load in a simple but different manner. The exergy loss can be minimized by allowing the supply flow pressure to decrease to a sub-atmospheric pressure concurrent with heat exchange with the sub-atmospheric flow from the load. This dissertation work encompasses testing of a practical implementation using a Collin's type heat exchanger to investigate the overall performance, as well as, the optimum selections of independent process parameters and how this affects the heat exchanger size distribution. The thermodynamics of heat exchange with a significant pressure drop for a non-ideal fluid are investigated, in regards to an equivalent expansion efficiency pseudo-property, a practical process expansion efficiency equivalence and an overall 2-K system performance improvement expectation. Theoretically predicted optimum independent process parameters are compared to those measured.

Knudsen, Peter↗

db, Version 0.x

A set of programs and utilities for generating and manipulating data files in TSV (tab-separated value) or JSON format.

Hash, Curtis↗

Targets for a Neutral Kaon Beam

A secondary beam of neutral Kaons is under consideration for Hall D at Jefferson Lab to perform spectroscopic studies of hyperons produced by K 0 L particles scattering from proton and deuteron targets. The proposed physics program would utilize the GlueX detector package currently installed in Hall D. This contribution looks at potential targets for use in the new facility, paying close attention to the existing infrastructure of GlueX and Hall D. Unpolarized cryotargets of liquid hydrogen and deuerium, as well as polarized solid targets of protons and deuterons are examined.

Keith, Christopher↗

An Assessment of Fission Product Scrubbing in Sodium Pools Following a Core Damage Event in a Sodium Cooled Fast Reactor

The U.S. Nuclear Regulatory Commission has stated that mechanistic source term (MST) calculations are expected to be required as part of the advanced reactor licensing process. A recent study by Argonne National Laboratory has concluded that fission product scrubbing in sodium pools is an important aspect of an MST calculation for a sodium-cooled fast reactor (SFR). To model the phenomena associated with sodium pool scrubbing, a computational tool, developed as part of the Integral Fast Reactor (IFR) program, was utilized in an MST trial calculation. This tool was developed by applying classical theories of aerosol scrubbing to the decontamination of gases produced as a result of postulated fuel pin failures during an SFR accident scenario. The model currently considers aerosol capture by Brownian diffusion, inertial deposition, and gravitational sedimentation. The effects of sodium vapour condensation on aerosol scrubbing are also treated. This paper provides details of the individual scrubbing mechanisms utilized in the IFR code as well as results from a trial mechanistic source term assessment led by Argonne National Laboratory in 2016.

Fission Product Scrubbing↗

SolSmart Issue Brief - Solar and Electrification A Beneficial Partnership

Policies that encourage solar development and policies that encourage electrification can be complementary: low-cost solar power can help make electrification more cost-effective, and electrifying more services can help make solar installations more valuable. Electrification policies also open the door to discussions with the local electric utility regarding how utilities can better support communities’ solar power aspirations. This guide explains how communities can collaborate with their utilities on programs that produce complementary benefits for solar and electrification policies.

14 SOLAR ENERGY↗

Piloting the Use of Energy Policy Data to Drive Market Action

Information is only useful when put to use. Across the U.S., an ever-growing number of state and local jurisdictions are implementing building performance reporting laws regarding building energy and water use in the commercial and multifamily sectors. This wealth of performance information is not yet being deployed to its full potential to drive smarter business decisions and increase energy savings. Recognizing that this information can help advance energy efficiency in cities, in 2015 the Institute for Market Transformation (IMT) partnered with New York City and the District of Columbia and local groups, NYCEEC and the District of Columbia Sustainable Energy Utility, on a three-year project to understand and document how, exactly, this data can and should be integrated to reap an array of benefits for cities, energy efficiency service providers, utilities, and building owners. This paper examines how local governments, utilities, and program implementers can replicate the success of DC and NYC. It gathers the findings from the Cities’ and their partners’ efforts to fully understand the datasets, overcome integration challenges, and apply the data to visual engagement, strategic outreach, evidence-based policymaking, and retrofit project identification and deployment. The paper goes beyond theoretical discussion by outlining practical application of data using specific examples from NYC and DC, summarizing challenges and findings, and highlighting next steps for other jurisdictions to learn from and build off the work done in those jurisdictions.

Cities↗

Enabling Interconnected Science Workflows through an Adapter Approach

The INTERSECT Software framework project aims to create an open federated library that connects, coordinates, and controls systems in the scientific domain. It features the Adapter, a flexible and extensible interface inspired by the Adapter design pattern in object-oriented programming. By utilizing Adapters, the INTERSECT SDK enables effective communication and coordination within a diverse ecosystem of systems. This adaptability facilitates the execution of complex operations within the framework, promoting collaboration and efficient workflow management in scientific research. Additionally, the generalizability of Adapters and their patterns enhances their utility in other scientific software projects and challenges.

McGaha, Jesse↗

A Comparison of Select USDOE and USEPA Risk and Dose Assessment Tools Utilized at Two FUSRAP Projects - 17388

The US Army Corps of Engineers (USACE) utilizes several computer programs and models to conduct risk and dose assessments at Formerly Utilized Sites Remedial Action Program (FUSRAP) projects. In the past, the USACE has primarily relied on the US Department of Energy (USDOE)'s Argonne National Lab (ANL) RESidual Radioactivity (RESRAD) computer code for performing dose and risk assessments involving radiological contamination in onsite soils and the US Environmental Protection Agency (USEPA) Preliminary Remediation Goal (PRG) and Dose Compliance Calculator (DCC) for radiological contamination in ground water. Recent USEPA guidance requires use of USEPA calculators for all media at National Priority List sites, which includes some FUSRAP sites. The USACE recently utilized both RESRAD and the USEPA PRG and DCC calculators in assessments at two FUSRAP projects for all media in order to evaluate differences in the models and determine adjustments to potentially resolve differences. The two projects involve soil and groundwater assessments and address typical FUSRAP contaminants such as uranium, radium, thorium and their progeny. This paper discusses differences between the models, lessons learned, and methods used to address stakeholder and other concerns regarding these assessments. The paper's discussions are useful for anyone performing risk or dose assessments for radiological contamination and especially those using RESRAD and the PRG and DCC calculators. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

State Indicators for Advancing Demand Flexibility and Energy Efficiency in Buildings - Part I [Slides]

This slide deck report identifies objectives and key indicators for state activities that advance demand flexibility in buildings — legislation, utility regulatory proceedings, executive orders and programs. It also illustrates progress to date and identifies trends, gaps, and opportunities. Part I of the report focuses on (1) demand response and (2) energy efficiency targeted to reduce peak demand or integrate with demand response. This section covers building energy codes, appliance and equipment standards, resource standards, utility planning, utility programs, advanced metering infrastructure and meter data, rate design, state programs, state energy planning, and related state policies and regulations. Part II of the report addresses traditional energy efficiency indicators, including utility and state programs, codes, and standards that support annual energy savings. See the additional links for an infographic, library of cited state documents on demand flexibility, and presentation to the NASEO-NARUC Grid-Interactive Efficient Buildings Working Group.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗