Active Torque Control for Gearbox Load Reduction in a Variable-Speed Wind Turbine
Abstract not provided
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided
Partial characterization of a series of electrostatically actuated active microfluidic valves is to be performed. Tests are performed on a series of 24 valves from two different MEMS sets. Focus is on the physical deformation of the structures under variable pressure loadings, as well as voltage levels. Other issues that inhibit proper performance of the valves are observed, addressed and documented as well. Many microfluidic applications have need for the distribution of gases at finely specified pressures and times. To this end a series of electrostatically actuated active valves have been fabricated. Eight separate silicon die are discussed, each with a series of four active valves present. The devices are designed such that the valve boss is held at a ground, with a voltage applied to lower contacts. Resulting electrostatic forces pull the boss down against a series of stops, intended to create a seal as well as prevent accidental shorting of the device. They have been uniquely packaged atop a stack of material layers, which have inlaid channels for application of fluid flow to the backside of the valve. Electrical contact is supplied from the underlying printed circuit board, attached to external supplies and along traces on the silicon. Pressure is supplied from a reservoir of house compressed air, up to 100 Psig. This is routed through a Norgren R07-200-RGKA pressure regulator, rated to 150 Psig. From there flow passes a manually operated ball valve, and to a flow meter. Two flow meters were utilized; initially an Omega FMA1802 rated at 10 sccm, and followed by a Flocat model for higher flow rates up to 100 sccm. An Omega DPG4000-500 pressure gauge produced pressure measurements. Optical measurements were returned via a WYKO Interferometry probe station. This would allow for determination of physical deformations of the device under a variety of voltage and pressure loads. This knowledge could lead to insight as to the failure mechanisms of the device, yielding improvements for subsequent fabrications.
In the U.S., a number of utilities are adopting higher penetrations of renewables, driven in part by state policies. While power systems have been designed to handle the variable nature of loads, the additional supply-side variability and uncertainty can pose new challenges for utilities and system operators. However, a variety of operational and technical solutions exist to help integrate higher penetrations of wind and solar generation. This paper explores renewable energy integration challenges and mitigation strategies that have been implemented in the U.S. and internationally, including forecasting, demand response, flexible generation, larger balancing areas or balancing area cooperation, and operational practices such as fast scheduling and dispatch.
This three-year demonstration and deployment project sought to address market barriers to accelerating the adoption of Advanced Lighting Controls (ALCs), an underutilized technology with low market penetration. ALCs are defined as networked, addressable lighting control systems that utilize software or intelligent controllers to combine multiple energy-saving lighting control strategies in a single space (e.g., smart-time scheduling, daylight harvesting, task tuning, occupancy control, personal control, variable load-shedding, and plug-load control). The networked intelligent aspect of these systems allows applicable lighting control strategies to be combined in a single space, layered over one another, maximizing overall energy-savings. The project included five real building demonstrations of ALCs across the Northeast US region. The demonstrations provided valuable data and experience to support deployment tasks that are necessary to overcome market barriers. These deployment tasks included development of training resources for building designers, installers, and trades, as well as development of new energy efficiency rebates for the technology from Efficiency Forward’s utility partners. Educating designers, installers, and trades on ALCs is a critical task for reducing the cost of the technology that is currently inflated due to perceived complexity and unfamiliarity with how to design and install the systems. Further, utility and non-utility energy efficiency programs continue to relegate the technology to custom or ill-suited prescriptive program designs that do not effectively deploy the technology at scale. This project developed new, scalable rebate approaches for the technology. Efficiency Forward utilized their DesignLights Consortium® (DLC) brand and network of 81 DLC member utilities to develop and deploy the results of the project. The outputs of the project have included five published case studies, a six-hour ALC technology training curriculum that has already been deployed in five US states, and new rebates offered for the technology that have been deployed by a dozen utilities across the US. Widespread adoption of ALC technology in commercial buildings would provide tremendous benefits. The current market penetration of ALC systems is estimated at <0.1% in commercial buildings. If ALC systems were installed in all commercial buildings, approximately 1,051 TBtu of energy could be saved. This would translate into customer cost savings of approximately $10.7 billion annually.
This report presents an evolutionary cyclic plasticity based transformative approach for fatigue evaluation of safety critical components. This approach is generic which can be used not only for the present generation light water reactor components (which is our focus) but also for advanced reactor components. The approach is based on the fundamental concept of time-evolution of progressive fatigue damage rather than the end-of-life data based conventional S~N curve approaches. Series of fatigue tests on 316 stainless steel uniaxial specimens were conducted under strain-controlled and stress-controlled cyclic loading in two different environment such as in-air at 300 °C and PWR coolant water condition at 300 °C. Material models are developed to capture the uniaxial test data and are subsequently programmed into commercially available ABAQUS code to transform the uniaxial material behavior to multiaxial loading domain. The developed evolutionary cyclic-plasticity approach is verified by both analytical and 3D-FE modeling of uniaxial fatigue test specimens. Results show that the developed material models can capture the time-dependence of material hardening and softening with great accuracy. In addition, results show that the material models not only can capture the material behavior under constant amplitude loading but also can capture the load-sequence effect under variable and random amplitude loading. The ANL developed approach is one of its kind, which shows first in the fatigue research community that fatigue evaluation of a component (in our case verified for laboratory scale fatigue test specimens with great accuracy) can be performed for its entire fatigue life, including the hardening and softening behavior, without using a conventional S~N curve based approach. Additionally results are presented related to fatigue evaluation of real reactor components such as of a pressurized water reactor (PWR) surge line (SL), under upset transient conditions. SLs of PWR experience complex thermal stratification due to the mixing of differential temperature flow from hot leg and pressurizer. A detailed parametric study of thermal stratification in SL is performed through both standalone computational fluid dynamics (CFD) analysis and fluid-structure-interaction based coupled CFD and heat transfer analysis. Results show that the mass flow rate in SL substantially affects the extent of its thermal stratification. The resulting thermal boundaries conditioned are used as inputs for thermal-mechanical stress analysis and component level fatigue evaluation. Fatigue evaluation of SL pipe under example loading conditions was performed using the above-mentioned evolutionary-plasticity based approach and ASME code (for in-air life) and NUREG-6909 (for PWR environment life) based approaches. Results show that the evolutionary plasticity based approach estimate substantially different life compared to the conventional ASME based approach. To show the entirety of the proposed evolutionary fatigue-modeling framework, this report includes the results presented in semi-annual March report (ANL/LWRS-17/01). Sections 2-5 of March report are directly included as Sections 2-5 in this report, without any significant changes. However, Sections 6-9 of this report present the work performed during March-September of 2017. Whereas, Sections 1 and 10 present the organization of this report and the summary and future work, respectively. This report (ANL/LWRS-17/03 Rev. 1) is a slightly revised version of the earlier published report (ANL/LWRS-17/03). In this revised version, some of the results and associated discussion have been corrected/updated.
Electricity markets are changing because of (1) the addition of wind and solar that creates volatile electricity prices including times of zero-priced electricity and (2) the goal of a low-carbon world that requires replacing fossil fuels that provide (a) energy, (b) stored energy, and (c) dispatchable energy. Wind and solar provide energy but not the other two other energy functions that are provided fossil fuels. Nuclear energy with heat storage can provide all three functions and thus replace fossil fuels.
Tritium-producing burnable absorber rods (TPBARs) are designed to produce tritium when irradiated in a pressurized water reactor (PWR), within a commercial fuel assembly. Within a TPBAR, annular ceramic pellets consisting of Lithium Aluminate LiAlO 2 contain a given linear loading of Li-6, which undergoes neutron capture thus producing Tritium. Obtaining the proper Li-6 loading currently requires blending of powder prior to pellet manufacturing, or volume reduction of a higher lithium loading pellet to that of the desired loading. This study demonstrates the neutronic performance of both inner and outer volume-reduced Li-6 pellets as comparable to that of a standard dimension, non-milled pellet by modelling 8,250 distinct fuel assembly lattices with Studsvik’s CASMO5. Conditions included are at reactor Hot Full Power (HFP), Hot Zero Power (HZP) and Cold Zero Power (CZP) for 4.80-8.0 U-235 w/o, 8-24 TPBARs, 0-200 IFBAs, and 29-50 mg/in Li-6. Modeling these possible assembly designs results in a maximum TPBAR rod worth of 900 pcm. A maximum difference in rod worth of 127 pcm and a maximum pin power RMS difference of .0007 shows that volume reduction is a viable option for achieving desired lithium loading. Greatest rodworth and power differences occur between standard dimension non-milled and outer-volume-reduced Li-6 loading.
This guide provides an overview of GEB characteristics and benefits and how to analyze, identify, and implement GEB retrofit opportunities. It is important to understand the building’s systems as well as what utility program offerings are available at the site (e.g., time-of-use, electricity rates, demand charges, demand response programs, etc.). It is also important to understand the key goals for the site (e.g., environmental, cost savings, energy savings) and the current energy usage breakdown by equipment and load profile variability by day, month, and season.
Resource adequacy (RA) is an important component of bulk power system reliability that addresses whether there are sufficient resources available to meet electricity demand at all times. RA analysis is used to assess whether the planned power system will provide reliable electricity to consumers while accounting for equipment outages, weather variability, and load uncertainty. Coordination between regions can enable resource sharing to meet RA needs if sufficient transmission capacity exists. Transmission's role in RA coordination can be particularly pronounced for large power systems like the U.S. electricity grid which contains geographically diverse demand and weather-dependent resources. Depending on the level of coordination desired, existing inter-regional transmission capacity may not be sufficient. This study is designed to assess optimal pathways for the development of inter-regional transmission in the U.S. under varying levels of RA coordination. Results can inform long-term grid infrastructure planning and provide insights into potential benefits of greater coordination for generation and transmission planning between regional U.S. power systems.
Variable amplitude loading, fatigue loading, fatigue crack propagation and structural parts - fatigue life
Cumulative fatigue damage of structural parts subjected to variable amplitude loading
Electropneumatic rheostat maintains a constant direct current in each of several high-power parallel loads, of variable resistance, across a single source. It provides current regulation at any preset value by dissipating the proper amount of energy thermally, and uses a column of mercury to vary the effective length of a resistance element.
Multimission solar electric spacecraft of modest size and variable propellant loading for interchangeable space missions - Vol. 1A
Variable water load for dissipating large amounts of electrical power during high voltage power supply tests
A methanol heat pipe using nitrogen gas for temperature control has been constructed and tested. The system was run over a power ratio of 15 (2 to 30 watts) with the heat source near ambient temperature and with the heat sink at a nominal value of 32 F. Control was obtained with a metal bellows gas reservoir which was actuated by an internal liquid-filled bellows. The liquid bellows was pressurized by expanding liquid methanol which was contained in an auxiliary reservoir in the evaporator heater block. It was demonstrated that the temperature variation of the heat source was reduced from 36 F for the heat pipe with no control to 7 F with the actuated bellows control.
Explore the source record for details and available documents.
A tapered-roller bearing test machine was designed, fabricated and successfully operated at speeds to 20,000 rpm. Infinitely variable radial loads to 26,690 N (6,000 lbs.) and thrust loads to 53,380 N (12,000 lbs.) can be applied to test bearings. The machine instrumentation proved to have the accuracy and reliability required for parametric bearing performance testing and has the capability of monitoring all programmed test parameters at continuous operation during life testing. This system automatically shuts down a test if any important test parameter deviates from the programmed conditions, or if a bearing failure occurs. A lubrication system was developed as an integral part of the machine, capable of lubricating test bearings by external jets and by means of passages feeding through the spindle and bearing rings into the critical internal bearing surfaces. In addition, provisions were made for controlled oil cooling of inner and outer rings to effect the type of bearing thermal management that is required when testing at high speeds.
An all heat pipe, deployable radiator has been developed which can effectively control pumped fluid loop temperatures under varying loads using variable conductance panel heat pipes. The 2.2 sq m (24 sq ft) aluminum panel can be coupled to either a fluid header or a flexible heat pipe header capable of transporting 850 watts in a 90-deg bent configuration. Test results support the feasibility of using this system to passively control Freon-21 loop temperatures.