Search NASA⌕ Search

SEARCH · Search NASA

Results for “variable renewable energy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Accessible, uniform protein property prediction with a scikit-learn based toolset AIDE

Summary Protein property prediction via machine learning with and without labeled data is becoming increasingly powerful, yet methods are disparate and capabilities vary widely over applications. The software presented here, “Artificial Intelligence Driven protein Estimation (AIDE)”, enables instantiating, optimizing, and testing many zero-shot and supervised property prediction methods for variants and variable length homologs in a single, reproducible notebook or script by defining a modular, standardized application programming interface (API), i.e. drop-in compatible with scikit-learn transformers and pipelines. Availability and implementation AIDE is an installable, importable python package inheriting from scikit-learn classes and API and is installable on Windows, Mac, and Linux. Many of the wrapped models internal to AIDE will be effectively inaccessible without a GPU, and some assume CUDA. The newest stable, tested version can be found at https://github.com/beckham-lab/aide_predict and a full user guide and API reference can be found at https://beckham-lab.github.io/aide_predict/. Static versions of both at the time of writing can be found on Zenodo.

36 MATERIALS SCIENCE↗

Impacts of photovoltaic solar energy on soil carbon: A global systematic review and framework

Globally, solar energy is anticipated to be the primary source of electricity as early as 2050, and the greatest additions in capacity are currently in the form of large, ground-mounted photovoltaic solar energy facilities (GPVs). Growing interest lies in understanding and anticipating opportunities to increase soil carbon sequestration across the footprint and perimeter of both conventional and multi-use GPVs (e.g., ecovoltaics, agrivoltaics, and rangevolatics), especially as operators increasingly deputize as land managers. To date, studies on the relationship between soils and PV solar energy are limited to unique, localized sites. This study employed a systematic review to (i) identify a global corpus of 18 studies on interactions between GPVs and soils, (ii) collect and characterize 113 soil and soil-related experimental variables interacting with GPVs from this corpus, and (iii) synthesize trends among these experimental variables. Next, this study combined data from the systematic review with an iterative, knowledge co-production approach to produce a conceptual model for the study of soil and GPV interactions that applies to multiple installation types, scales, and contexts where GPVs are deployed, and identified research opportunities, threats, and priorities. This study's baseline understanding, conceptual model, and co-produced knowledge confer unique insight into the feasibility of combining soil carbon sequestration with the climate change mitigation potential of PV solar energy.

agrivoltaics↗

Experimental characterization of a triply periodic minimal surface PCM-to-air thermal energy storage device

Here, the expansion of energy production has intensified research into thermal energy storage (TES) to manage variability and improve system efficiency. Heat exchanger design is critical to achieving high power densities in TES systems. This study presents a high-surface-area phase change material (PCM)-to-air heat exchanger fabricated via resin-based stereolithography with a novel gyroid-based geometry tailored for enhanced performance. Material properties of the commercial PCM and resin were characterized using analytical techniques. A controlled air loop was used to evaluate heat transfer and pressure drop at various flow rates and inlet temperatures. Results show a strong dependence on the inlet temperature difference (ΔT) relative to the PCM melting point. During charging at the highest flow rate, increasing the inlet air temperature from ΔT = 5 °C to 20 °C above the melting point increased the average heat transfer rate by 187%. During discharging, decreasing the inlet temperature by the same ΔT below the melting point led to a 232% increase. Notably, the high-surface-area design enabled nearly symmetric charging and discharging behavior, a novel result for PCM-based TES systems which are often restricted by natural convection and other effects. The overall heat transfer coefficient was calculated and compared to values from standard design correlations. The maximum thermal effectiveness reached 95% at ΔT = 20 °C and a moderate flow rate of 34 m 3 /h. Peak coefficients of performance (COP) of 7 during charging and 6.4 during discharging were observed at ΔT = 20 °C and a low flow rate of 20 m 3 /h. These results demonstrate the viability of additively manufactured geometries for advanced TES applications.

25 ENERGY STORAGE↗

A Novel Framework to Evaluate the Costs and Potential of Bioenergy in Decarbonization of the U.S. Economy

The long-term strategy of the United States targets reaching economy-wide net-zero emissions by 2050 and a carbon-neutral electricity grid by 2035 (U.S. Department of State and U.S. Executive Office of the President, 2021). Meeting these targets would require considerable changes to the energy system. Some key characteristics of illustrative net-zero energy systems include increased penetration of renewable energy and carbon sources, use of CO2 capture and storage (CCS) in hard-to-abate sectors, and a greater role for energy carriers such as electricity and hydrogen (Davis et al, 2018). Another common feature of such energy systems is the need for carbon dioxide removal (CDR) approaches (Horowitz et al, 2022). Across all these characteristics of net-zero energy systems, bioenergy and biomass feedstock is anticipated to play an important role. Biomass feedstock serves as a renewable carbon source. This can enable conversion of such feedstock into fuels and energy carriers for hard-to-abate sectors such as aviation. Indeed, the U.S. Government has a target to meet all jet fuel demand by 2050 from sustainable aviation fuel (SAF), where biofuel pathways are likely to have an important role (EERE, 2020). Bioenergy is also highly versatile with the possibility to convert feedstock into electricity, hydrogen, liquid fuels, heat or high-value products, based on biomass type, demand and technology availability (Clarke et al, 2022). Combination of bioenergy with CCS can also nominally deliver CDR (Fuhrman et al, 2023). As such, the share of bioenergy is expected to grow by at least five time across scenarios studied for the long-term strategy of the U.S. between 2020 and 2050 (Horowitz et al, 2022). Notwithstanding the role of bioenergy in the energy systems, its deployment, costs and scalability are influenced by a number of factors. Some of these factors pertain to policy interventions such as imposition of a binding decarbonization target either at an economy-wide level or the sectoral level. Resource availability and type of biomass feedstock also varies considerably across regions. From a technological perspective, the readiness of bioenergy conversion pathways is subject to high variability. This influences the costs of deployment. Moreover, the sourcing of feedstock, grid carbon intensity, and co-product handling approaches all affect the life cycle efficacy of bioenergy. The latter, in turn, is particularly important in determining the extent to which bioenergy with CCS or BECCS can effectively deliver CDR (Fajardy and Mac Dowell, 2017).

air emission↗

De-Risking High-Recovery Brackish Water Desalination via Flow Reversal and Feed Flushing Using Techno-Economic Assessment

Novel desalination technologies have demonstrated enhanced performance and improved financial metrics over existing processes adopted by industry. Establishing quantitative performance targets is essential for achieving financial benefits over the current state of the art. Herein, we demonstrate how WaterTAP, a techno-economic assessment (TEA) tool, can be used to identify minimum performance metrics necessary to achieve financial benefit over using existing processes. This study evaluates the feasibility of increasing water recovery at the Chino Desalter I above 90 % through the addition of a third variable configuration reverse osmosis (VCRO) stage. Sensitivity analyses revealed flow reversal frequency, feed flushing volume (used as a cleaning step), and membrane lifespan are key factors influencing the financial viability of the VCRO process. The TEA analysis demonstrated that the system must achieve a recovery of 84 % and a 1-year membrane lifespan to have a breakeven LCOW, while achieving 90 % recovery can ultimately reduce the LCOW by 16 %. Notably, a trade-off between decreasing frictional losses and increased osmotic pressure across the recovery range, resulted in a stable specific energy consumption across the recovery range, enabling meaningful LCOW reductions without an energy penalty, a key finding that contrasts with conventional RO. This work demonstrates how TEA can guide system design by identifying key performance targets and exploring trade-offs, enabling data-driven decisions to de-risk innovative processes. These findings underscore the importance of leveraging TEA to evaluate scaling mitigation strategies and optimize inland desalination systems for sustainable and cost-effective operation.

14 SOLAR ENERGY↗

Operating Wind Turbine as Synchronous Generator: Modeling and Power-Hardware-in-the-Loop Demonstration

Grid-forming (GFM) control of Type 3 and Type 4 wind turbine generators (WTGs) has attracted substantial attention in power systems research; however, the limited overcurrent capability of power electronics converters continues to deteriorate the grid strength of the evolving power systems. Synchronous wind, also referred to as a Type 5 WTG, offers a unique GFM solution to address grid integration and grid strength issues by keeping the grid largely synchronous at very high integration levels of renewable generation. A Type 5 WTG interfaces with the electric grid via a synchronous generator driven by a variable speed hydraulic torque converter; hence, the wind rotor operates in variable-speed mode for maximum power generation, and the generator shaft remains synchronous to the grid. This paper develops and tests a high-fidelity model of a Type 5 WTG in a power-hardware-in-the-loop testing environment, and it presents its operation characteristics under different grid contingencies. The power-hardware-in-the-loop demonstration shows that a Type 5 WTG inherently behaves as a GFM unit and can obtain similar performance in terms of power response, wind rotor dynamics, and stability enhancement compared to a Type 3 WTG in GFM control mode. Furthermore, the paper provides further insight into how Type 5 WTGs can support the smooth transition to power systems with high integration levels of inverter-based resources.

17 - WIND ENERGY↗

Modeling and Power-Hardware-in-the-Loop Validation of Synchronous Wind: An Inverterless Grid-Forming Wind Power Plant: Preprint

Grid-forming (GFM) control of Type-3 and Type-4 wind turbine generators has attracted substantial attention in power systems research; however, the limited over-current capability of power electronics converters continues to deteriorate the grid strength of the evolving power systems. Synchronous wind, also known as Type-5 wind turbine generator (WTG), offers a unique GFM solution to address grid integration and grid strength issues by keeping the grid largely synchronous at very high penetration levels of renewable generation. A Type-5 WTG interfaces to the electric grid via a synchronous generator (SG) driven by a variable-speed hydraulic torque converter; hence, the wind rotor operates in variable-speed mode for maximum power generation and the generator shaft remains synchronous to the grid. This paper developed and tested a high-fidelity model of Type-5 WTG under power-hardware-in-the-loop (PHIL) testing environment. The PHIL demonstration showed that a Type-5 WTGs inherently behaves as a GFM unit and can obtain similar performance in terms of power responses, wind rotor dynamics, and efficiency compared to Type-3 WTG in high wind conditions. The developed model also provides further insight on how Type-5 WTGs can benefit the smooth transition to power systems with high integration level of inverter-based resources.

grid strength↗

Modeling and Power-Hardware-in-the-Loop Validation of Synchronous Wind: An Inverterless Grid-Forming Wind Power Plant

Grid-forming (GFM) control of Type-3 and Type-4 wind turbine generators (WTGs) has attracted substantial attention in power systems research; however, the limited overcurrent capability of power electronics converters continues to deteriorate the grid strength of the evolving power systems. Synchronous wind, also known as a Type-5 WTG, offers a unique GFM solution to address grid integration and grid strength issues by keeping the grid largely synchronous at very high integration levels of renewable generation. A Type-5 WTG interfaces with the electric grid via a synchronous generator driven by a variable-speed hydraulic torque converter; hence, the wind rotor operates in variable-speed mode for maximum power generation, and the generator shaft remains synchronous to the grid. This paper develops and tests a high-fidelity model of a Type-5 WTG in a power-hardware-in-the-loop (PHIL) testing environment. The PHIL demonstration shows that a Type-5 WTG inherently behaves as a GFM unit and can obtain similar performance in terms of power responses, wind rotor dynamics, and efficiency compared to a Type-3 WTG in high-wind conditions. The developed model provides further insight into how Type-5 WTGs can benefit the smooth transition to power systems with high integration levels of inverter-based resources.

grid strength↗

A consumer-centric approach to quantify efficiency of receiving goods purchased via online

Virtual participation in shopping activities has increased exponentially in the past four years compared to the last couple of decades. E-tailing or online shopping offers the convenience of goods reaching a consumer instead of a consumer traveling to a store, but it has downsides like geographical service variability and negative social externalities such as increased energy consumption and emissions. This study proposes a novel approach to quantify e-tailing efficiency from the consumers’ viewpoint. The methodology is innovative in its integration of accessibility theory with energy and cost impedance factors and consideration of delivering and picking up goods purchased via online. The methodology is implemented for the San Francisco Bay Area and is subject to scenarios that see enhancements to various facets of online shopping delivery. Results demonstrate that increasing the frequency of e-commerce deliveries helps improve e-tailing efficiency in rural locations, while improvements in energy and cost aspects of delivery modes are seen to improve e-tailing efficiencies in the central parts of the region. The approach proposed can provide valuable insights on where people have limited benefits from online shopping and how emerging delivery mechanisms can change the quality of the e-commerce experience within a city. This research offers a replicable framework for assessing e-commerce systems in diverse geographic contexts, contributing to the development of equitable and environmentally sustainable urban freight systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Fish Friendly Water Rules' Impact On the Power Grid with High VRE Levels

Columbia River basin multipurpose reservoirs are operated for hydropower production and many other purposes considering the aquatic habitat of the river basin. Specifically, the river basin fish population is a vital element for the tribal community of the river basin. When conventional thermal power plants are retired, hydropower flexibility balances the wind and solar variability of the power grid and provides grid services to maximize the high renewable power absorption. On the other hand, over-reliance on hydropower could harm the river basin fish habitat. For example, water release pulses during peak electricity demand hours and shorter-term water release variation could harm the fish population. Power grid planners, environmentalists, Columbia Basin tribes, hydro regulators, and water resource planners work together to understand the impacts of Columbia River basin operation in a fish-friendly way in the current power grid and power grid with higher renewable power share. We examine different levels of renewable share in the Western Interconnection to understand the multiple weather years and future climate projection and operating scenario impact on the power grid and water system. We measure power grid impacts for various water resources planning scenarios in terms of total system operating cost, system reliability indicators, changes in wind and solar generation and curtailments, local marginal prices, and revenue for hydropower producers. The study results inform reservoir operating rules decisions from hydropower power producers, system operators, other water users, tribes, environmentalists, and other stakeholders.

environmental↗

A Dual-Mode Hybrid System Combining Solar Thermal With Pumped Thermal Energy Storage

A hybrid system that delivers renewable electricity generation and electricity storage capabilities is introduced. This dual-mode hybrid system is based on Pumped Thermal Energy Storage (PTES) which uses a heat pump to convert electricity into thermal energy that is trans-ferred to silica particles which are stored in concrete silos. The stored heat is later converted back to electricity in a heat engine. The heat pump and heat engine use a closed Joule-Brayton cycle and fluidized bed heat exchangers. If the PTES system is co-located with an array of concentrating solar mirrors and a particle receiver, then the silica particles may also be heated up by the concentrating solar power (CSP) system. The PTES heat engine may also be used to convert the stored solar heat into electricity, thereby sharing this system between the PTES and CSP systems and reducing costs. However, this requires careful management of the heat engine off-design parameters. A thermodynamic model is used to evaluate the performance of the dual mode PTES-CSP hybrid system. The model accounts for turbomachinery effi-ciency, and approach temperature and pressure loss in heat exchangers, as well as other sources of inefficiency, such as motor-generator losses, and air fan power. The hybrid system also requires the evaluation of the turbomachinery efficiency and pressure ratio at off-design conditions since the CSP system operates over different temperature ratios than the Carnot Battery. Several design variables and design modifications are investigated, such as pressure ratios and maximum temperatures.

14 SOLAR ENERGY↗

Validation of Atmosphere/Ionosphere Signals Associated with Major Earthquakes by Multi-Instrument Space-Borne and Ground Observations

The latest catastrophic earthquake in Japan (March 2011) has renewed interest in the important question of the existence of pre-earthquake anomalous signals related to strong earthquakes. Recent studies have shown that there were precursory atmospheric/ionospheric signals observed in space associated with major earthquakes. The critical question, still widely debated in the scientific community, is whether such ionospheric/atmospheric signals systematically precede large earthquakes. To address this problem we have started to investigate anomalous ionospheric / atmospheric signals occurring prior to large earthquakes. We are studying the Earth's atmospheric electromagnetic environment by developing a multisensor model for monitoring the signals related to active tectonic faulting and earthquake processes. The integrated satellite and terrestrial framework (ISTF) is our method for validation and is based on a joint analysis of several physical and environmental parameters (thermal infrared radiation, electron concentration in the ionosphere, lineament analysis, radon/ion activities, air temperature and seismicity) that were found to be associated with earthquakes. A physical link between these parameters and earthquake processes has been provided by the recent version of Lithosphere-Atmosphere-Ionosphere Coupling (LAIC) model. Our experimental measurements have supported the new theoretical estimates of LAIC hypothesis for an increase in the surface latent heat flux, integrated variability of outgoing long wave radiation (OLR) and anomalous variations of the total electron content (TEC) registered over the epicenters. Some of the major earthquakes are accompanied by an intensification of gas migration to the surface, thermodynamic and hydrodynamic processes of transformation of latent heat into thermal energy and with vertical transport of charged aerosols in the lower atmosphere. These processes lead to the generation of external electric currents in specific regions of the atmosphere and the modifications, by dc electric fields, in the ionosphere-atmosphere electric circuit. We retrospectively analyzed temporal and spatial variations of four different physical parameters (gas/radon counting rate, lineaments change, long-wave radiation transitions and ionospheric electron density/plasma variations) characterizing the state of the lithosphere/atmosphere coupling several days before the onset of the earthquakes. Validation processes consist in two phases: A. Case studies for seven recent major earthquakes: Japan (M9.0, 2011), China (M7.9, 2008), Italy (M6.3, 2009), Samoa (M7, 2009), Haiti (M7.0, 2010) and, Chile (M8.8, 2010) and B. A continuous retrospective analysis was preformed over two different regions with high seismicity- Taiwan and Japan for 2003-2009. Satellite, ground surface, and troposphere data were obtained from Terra/ASTER, Aqua/AIRS, POES and ionospheric variations from DEMETER and COSMIC-I data. Radon and GPS/TEC were obtaining from monitoring sites in Taiwan, Japan and Italy and from global ionosphere maps (GIM) respectively. Our analysis of ground and satellite data during the occurrence of 7 global earthquakes has shown the presence of anomalies in the atmosphere. Our results for Tohoku M9.0 earthquake show that on March 7th, 2011 (4 days before the main shock and 1 day before the M7.2 foreshock of March 8, 2011) a rapid increase of emitted infrared radiation was observed by the satellite data and an anomaly was developed near the epicenter. The GPS/TEC data indicate an increase and variation in electron density reaching a maximum value on March 8. From March 3 to 11 a large increase in electron concentration was recorded at all four Japanese ground-based ionosondes, which returned to normal after the main earthquake. Similar approach for analyzing atmospheric and ionospheric parameters has been applied for China (M7.9, 2008), Italy (M6.3, 2009), Samoa (M7, 2009), Haiti (M7.0, 2010) and Chile (M8.8, 2010) eahquakes. Results have revealed the presence of related variations of these parameters implying their connection with the earthquake process. The second phase (B) of this validation included 102 major earthquakes (M>5.9) in Taiwan and Japan. We have found anomalous behavior before all of these events with no false negatives. False alarm ratio for false positives is less then 10% and has been calculated for the same month of the earthquake occurrence for the entire period of analysis (2003-2009). The commonalities for detecting atmospheric/ionospheric anomalies are: i.) Regularly appearance over regions of maximum stress (i.e., along plate boundaries); ii.) Anomaly existence over land and sea; and iii) association with M>5.9 earthquakes not deeper than 100km. Due to their long duration over the same region these anomalies are not consistent with a meteorological origin. Our initial results from the ISTF validation of multi-instrument space-borne and ground observations show a systematic appearance of atmospheric anomalies near the epicentral area, one to seven (average) days prior to the largest earthquakes, and suggest that it could be explained by a coupling process between the observed physical parameters and the pre-earthquake preparation processes.

Ouzounov, Dimitar↗

Modulating spin-valley relaxation in WSe 2 with variable thickness VOPc layers

Combining the synthetic tunability of molecular compounds with the optical selection rules of transition metal dichalcogenides (TMDCs) that derive from spin-valley coupling could provide interesting opportunities for the readout of quantum information. However, little is known about the electronic and spin interactions at such interfaces and the influence on spin-valley relaxation. Here, in this work, vanadyl phthalocyanine (VOPc) molecular layers are thermally evaporated on WSe 2 to explore the effect of molecular layer thickness on excited-state spin-valley polarization. The thinnest molecular layer supports an interfacial state which destroys the spin-valley polarization almost instantaneously, whereas a thicker molecular layer results in longer-lived spin-valley polarization than the WSe 2 monolayer alone. The mechanism appears to involve a tightly bound species at the molecule/TMDC interface that strengthens exchange interactions and is largely avoided in thicker VOPc layers that isolate electrons from WSe 2 holes.

2D materials↗

Characterization of Gulf Stream energy resources: A 30-year high-resolution simulation study

The strength and proximity of the Gulf Stream (GS) along the U.S. coast offers opportunities for marine energy extraction. Leveraging high-resolution (up to 400 m) long-term (30-year) hindcasts based on an unstructured grid model, this study characterizes the energy potential of the GS in two viable locations: the Florida Straits (FS) and Cape Hatteras (CH). Results reveal distinct characteristics in the kinetic energy flux (KEF) and kinetic energy density (KED) for the two regions. The 30-year mean KEF at CH is 27.50 GW, surpassing the 19.74 GW estimated for the FS, which is attributed to the wider cross-section of the GS in CH. Additionally, CH exhibits higher KEF variability due to GS’s larger path shifts and meanders. Estimated KEDs at ADCP site locations reach up to 2,908 W/m 2 in the FS and 1,512 W/m 2 in the CH at a depth of 20 m. High-energy zones are closer to shore in the FS, whereas energy-rich areas at CH are located further offshore. A depth-based KED analysis shows significant decreases across typical energy extraction depths (20 to 100 m), with reductions up to 44%. Finally, this study provides high-resolution resource characterization, forming a foundation for optimized site selection and marine hydrokinetic system design.

16 TIDAL AND WAVE POWER↗

Photoluminescence Excitation Spectroscopy of Monolithic Perovskite/Silicon Tandem Solar Cells

The contributions of each subcell to the total photoluminescence (PL) spectrum of a monolithic perovskite/silicon tandem solar cell are distinguished using a variable wavelength excitation laser source. Here, in the results, a strong overlap of the PL spectrum is shown, originating from the sub‐bandgap region of the perovskite top cell with the emission from the silicon bottom cell, even with near‐infrared excitation wavelengths. Consequently, an excitation laser wavelength of at least 815 nm is required for a dominant PL signal from the silicon bottom cell, and a wavelength no longer than 750 nm is needed for a dominant PL signal from the perovskite top cell in the investigated tandem solar cell. Moreover, a shoulder in the sub‐bandgap emission of the perovskite top cell almost coincides with the PL response region of the silicon bottom cell, which can cause signal confusion in subcell characterization.

14 SOLAR ENERGY↗

High-shade dryland agrivoltaic conditions enhanced carbon uptake and water-use efficiency in zucchini ( Cucurbita pepo )

Introduction: The increasing global demand for food and energy is intensifying land-use competition. Agrivoltaic systems are a multifunctional land-use approach that vertically integrates the production of agricultural crops and solar power on the same land area. Most food crops are adapted to full-sun conditions, and the physiological responses of these crops to the novel microclimate under solar panels remain poorly understood. We hypothesized that the microclimate beneath the high-density photovoltaic system would influence carbon uptake, water use, and yield outcomes of zucchini summer squash.Methods: We conducted a field experiment in a hot, semi-arid climate on zucchini (Cucurbita pepo). Plants were grown under an agrivoltaic system with a 75% ground cover ratio (GCR) and in a full-sun control plot, each with two irrigation regimes (100 and 50%). We measured leaf-level photosynthesis, microclimate variables, and fruit yield at plant maturity and throughout the growing season.Results: The agrivoltaic array reduced photosynthetically active radiation (PAR) by ~79%, resulting in a cooler (−1.1 °C), more humid environment with higher soil moisture. These microclimatic conditions enhanced midday photosynthesis and daily cumulative carbon uptake. However, fruit yield was consistently lower under the panels, indicating a shift in carbon allocation toward vegetative growth. Photosynthesis was primarily driven by PAR across treatments, while soil moisture significantly influenced photosynthesis only in the control plots, suggesting water limitation was alleviated under the panels.Discussion: These findings highlight a trade-off between improved physiological performance and reduced yield under high-density agrivoltaics. While the system buffered heat and drought stress and improved overall plant function, excessive shade reduced reproductive output. Optimizing panel density or selecting crops cultivated for non-fruit yields will be essential for balancing food production and energy generation in dryland agrivoltaic settings.

14 SOLAR ENERGY↗

Behind-the-Meter Model Results

These files contains aggregations of key variables from the NREL Distributed Wind Futures Study using full parcel level data. These variables describe total technical and economic potential for distributed wind turbine deployment. Aggregations are available at the (1) county, (2) zipcode (zip code tabulation area or zcta), and (3) US Census block group level. Each scenario is coded with the scenario name (e.g., baseline) and year (e.g., 2022). Those files postfixed with 'econpot' contain results for only those parcels that are economically viable while the files postfixed with 'techpot' include results for all parcels that are technically feasible. Hence these correspond to technoeconomic and technical potential respectively. The data are available as CSV or Geopackage. Columns in the files are as follows: * geoid: geographic identifier (FIPS code or similar) * min_techpot_sum_kw: technical potential for all parcels in kW using turbines downsized to demand when appropriate * max_techpot_sum_kw: technical potential for all parcels in kW without downsizing turbines * aep_sum_kwh: annual energy production estimate in kWh * cf_mean_ratio: mean capacity factor * lcoe_mean_cents_per_kwh: mean levelized cost of energy for parcels in geography in cents per kWh * lcoe_std_cents_per_kwh: standard deviation of the above * parcel_area_sum_acres: total area of viable parcels in acres * n_turbines: number of cited turbines (one per viable parcel currently)

17 WIND ENERGY↗

Comparing Outdoor to Indoor Performance for Bifacial Modules Affected by Polarization-Type Potential-Induced Degradation

Bifacial photovoltaic (PV) modules have the advantage of using light reflected off of the ground to contribute to power production. Predicting the energy gain is challenging and requires complex models to do so accurately. Often, module degradation over time is neglected in models for the sake of simplicity or is underestimated. Comparing outdoor and indoor current–voltage (I–V) performance for bifacial modules is more challenging than for monofacial modules, as there are additional variables to consider such as rear albedo non-uniformity, cell mismatch, and their effects on temperature. This challenge is compounded when heterogeneous degradation modes occur, such as polarization-type potential-induced degradation (PID-p). To examine the effects of PID-p on I–V predictions using an empirical data-driven approach, 16 bifacial PERC modules are installed outdoors on racks with different albedo conditions. A subset is exposed to high-voltage biases of −1500 V or +1500 V. Outdoor data are traced at irradiance ranges of 150–250 W/m 2 , 500–600 W/m 2 , and 900–1000 W/m 2 . These curves are corrected using control module temperature, wire resistivity, and module resistance measured indoors. We examine several methods to transform indoor I–V curves to accurately, and more simply than existing methods, approximate outdoor performance for bifacial modules without and with varying levels of PID-p degradation. This way, bifacial performance modeling can be more accessible and informed by fielded, degraded modules. Distributions of percent errors between indoor and outdoor performance parameters and Mean Absolute Percent Errors (MAPEs) are used to assess method quality. Results including low-irradiance data (150–250 W/m 2 ) are discussed but are filtered for quantifying method quality as these data introduce substantial errors. The method with the most optimal tradeoff between low MAPE and analysis simplicity involves measuring the front side of a module indoors at an irradiance equal to plane-of-array irradiance plus the product of module bifaciality and albedo irradiance. This method gives MAPE values of 1–6.5% for non-degraded and 1.6–5.9% for PID-p degraded module performance.

14 SOLAR ENERGY↗