Search NASA⌕ Search

SEARCH · Search NASA

Results for “vibration sensing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Surface Enhanced Raman Scattering Selectivity in Proteins Arises from Electron Capture and Resonant Enhancement of Radical Species

Plasmon-enhanced Raman scattering is a powerful approach to detecting and characterizing proteins in live and dynamic biological systems. However, the selective detection/enhancement of specific residues as well as spectral diffusion and fluctuations have complicated the interpretation of enhanced Raman spectra and images of biological matter. In this paper, we therefore demonstrate that the amino acid tryptophan (Trp) can capture an electron from an excited plasmon, which generates a radical anion that is resonantly enhanced: a visible excited electronic state slides into resonance upon charging. This surface enhanced resonance Raman scattering (SERRS) mechanism explains the persistence of Trp signatures in the SERS and TERS spectra of proteins. Evidence for this picture includes the observation of visible resonances in the UV-Vis extinction spectrum, changes in the ground state vibrational spectrum, and plasmon-resonance dependent behavior. DFT calculations support the experimental observations. The behavior observed from the free Trp molecule is shown to explain the SERS spectrum of the Trp-cage protein. In effect, resonant Raman scattering from radicals formed through plasmonic excitation represents an under-investigated mechanism that may be exploited for chemical sensing applications. This work was supported by the National Institutes of Health Award R01-GM109988. The authors thank Hannah Shafaat for helpful discussions and providing an azurin sample for comparison. The authors also thank Joel Harris for providing constructive comments on our manuscript.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multichannel Fiber-Optic Silicon Fabry–Pérot Interferometric Bolometer System for Plasma Radiation Measurements

A single-channel fiber-optic bolometer system based on a high-finesse silicon Fabry–Pérot interferometer (FPI) was previously reported, intended to measure plasma radiation from the magnetically confined fusion chamber. Recently, we developed a multichannel fiber-optic bolometer system with five bolometers multiplexed using a coarse wavelength division multiplexer (CWDM) and interrogated with a white-light system involving a superluminescent light-emission diode source and a high-speed spectrometer. One of the bolometers was used as the reference bolometer to compensate for the ambient temperature variations, and the other four bolometers were used for radiation measurement. The bolometers have a simple structure with a silicon pillar at the end of the single-mode fiber and a gold disk on the other side of the silicon pillar. They are also easy to fabricate without stringent requirements on the optical alignment. Analysis of the system optimization was performed to improve the noise performance and to mitigate the vibration effect that may present in the practical application. The system had a significantly enhanced measurement range compared to the previous high-finesse FPI bolometer system for measuring radiation. Test results performed in air using a 405 nm laser as the radiation source showed that the temperature resolution and the noise-equivalent power density of the sensing bolometers connected to each channel of the CWDM were, respectively, ~0.4 mK and ~0.1 W/m2, with a time constant of ~220 ms, which is comparable to the previous more complicated fiber-optic bolometer systems based on high-finesse FPIs that were interrogated using wavelength-scanning lasers.

Uddin, Nezam↗

Optical position measurement for a large gap magnetic suspension system: Design and performance analysis

An optical measurement system (OMS) has been designed and tested for a large gap magnetic suspension system (LGMSS). The LGMSS will be used to study control laws for magnetic suspension systems for vibration isolation and pointing applications. The LGMSS features six degrees of freedom and consists of a planar array of electromagnets that levitate and position a cylindrical element containing a permanent magnet core. The OMS provides information on the location and orientation of the element to the LGMSS control system to stabilize suspension. The hardware design of this optical sensing system and the tracking algorithms are presented. The results of analyses and experiments are presented that define the accuracy limits of the optical sensing system and that quantify the errors in position estimation.

Welch, Sharon S.↗

Inhibition of the spider heartbeat by gravity and vibration

The rate and vigor of the spider heartbeat is controlled by an external pacemaker. A mechanical feature of the spider cardio-vascular system is the production of high serum pressure in the prosoma and the legs. This appears to be the source for leg extension. The lyriform organ on the patella of the leg is sensitive to vibratory and kinesthetic stimuli. This sensitivity depends upon the degree of leg extension. Thus the activity of the heart and the response characteristics of the sense receptor are related. The effect of a supra-threshold vibratory or gravitational stimulus is to produce an inhibition and a tachycardia of the spider heartbeat.

Finck, A.↗

Active vibration control in microgravity environment

The low gravity environment of the space station is suitable for experiments or manufacturing processes which require near zero gravity. An experiment was fabricated to test the validity of the active control process and to verify the flow and control parameters identified in a theoretical model. Zero gravity is approximated in the horizontal plane using a low friction air bearing table. An analog control system was designed to activate calibrated air jets when displacement of the test mass is sensed. The experiment demonstrates that an air jet control system introduces an effective damping factor to control oscillatory response. The amount of damping as well as the flow parameters, such as pressure drop across the valve and flow rate of air, are verified by the analytical model.

Gerhold, Carl H.↗

Observation of surface states on gold films by electron tunneling spectroscopy

It is pointed out that inelastic electron tunneling spectroscopy (IETS) is a useful technique for the study of vibrational modes of molecules adsorbed on the surface of the insulating layer in a metal-insulator-metal tunnel junction. A detailed study of electron tunneling in aluminum-aluminum oxide-gold (Al-Al2O3-Au) tunnel junctions has been conducted with an overall goal of exploring possible mechanisms in such a thin film device useful for chemical sensing. For an understanding of the electronic effects in the presence of chemicals in a junction, the electronic surface properties of the metallic films in a clean tunnel junction must be established. The present investigation is concerned with room temperature observations of electronic states on the surface of highly oriented gold film in Al-Al2O3-Au junctions.

Lambe, J.↗

Nanowire Electron Scattering Spectroscopy

Nanowire electron scattering spectroscopy (NESS) has been proposed as the basis of a class of ultra-small, ultralow-power sensors that could be used to detect and identify chemical compounds present in extremely small quantities. State-of-the-art nanowire chemical sensors have already been demonstrated to be capable of detecting a variety of compounds in femtomolar quantities. However, to date, chemically specific sensing of molecules using these sensors has required the use of chemically functionalized nanowires with receptors tailored to individual molecules of interest. While potentially effective, this functionalization requires labor-intensive treatment of many nanowires to sense a broad spectrum of molecules. In contrast, NESS would eliminate the need for chemical functionalization of nanowires and would enable the use of the same sensor to detect and identify multiple compounds. NESS is analogous to Raman spectroscopy, the main difference being that in NESS, one would utilize inelastic scattering of electrons instead of photons to determine molecular vibrational energy levels. More specifically, in NESS, one would exploit inelastic scattering of electrons by low-lying vibrational quantum states of molecules attached to a nanowire or nanotube.

Hunt, Brian↗

Oxygen-Partial-Pressure Sensor for Aircraft Oxygen Mask

A device that generates an alarm when the partial pressure of oxygen decreases to less than a preset level has been developed to help prevent hypoxia in a pilot or other crewmember of a military or other high-performance aircraft. Loss of oxygen partial pressure can be caused by poor fit of the mask or failure of a hose or other component of an oxygen distribution system. The deleterious physical and mental effects of hypoxia cause the loss of a military aircraft and crew every few years. The device is installed in the crewmember s oxygen mask and is powered via communication wiring already present in all such oxygen masks. The device (see figure) includes an electrochemical sensor, the output potential of which is proportional to the partial pressure of oxygen. The output of the sensor is amplified and fed to the input of a comparator circuit. A reference potential that corresponds to the amplified sensor output at the alarm oxygen-partial-pressure level is fed to the second input of the comparator. When the sensed partial pressure of oxygen falls below the minimum acceptable level, the output of the comparator goes from the low state (a few millivolts) to the high state (near the supply potential, which is typically 6.8 V for microphone power). The switching of the comparator output to the high state triggers a tactile alarm in the form of a vibration in the mask, generated by a small 1.3-Vdc pager motor spinning an eccentric mass at a rate between 8,000 and 10,000 rpm. The sensation of the mask vibrating against the crewmember s nose is very effective at alerting the crewmember, who may already be groggy from hypoxia and is immersed in an environment that is saturated with visual cues and sounds. Indeed, the sensation is one of rudeness, but such rudeness could be what is needed to stimulate the crewmember to take corrective action in a life-threatening situation.

Kelly, Mark↗

Continuous Tuning and Calibration of Vibratory Gyroscopes

A method of control and operation of an inertial reference unit (IRU) based on vibratory gyroscopes provides for continuously repeated cycles of tuning and calibration. The method is intended especially for application to an IRU containing vibratory gyroscopes that are integral parts of microelectromechanical systems (MEMS) and that have cloverleaf designs, as described in several previous NASA Tech Briefs articles. The method provides for minimization of several measures of spurious gyroscope output, including zero-rate offset (ZRO), angle random walk (ARW), and rate drift. These benefits are afforded both at startup and thereafter during continuing operation, in the presence of unknown rotation rates and changes in temperature. A vibratory gyroscope contains a precision mechanically resonant structure containing two normal modes of vibration nominally degenerate in frequency and strongly coupled via a Coriolis term. In the case of the cloverleaf design MEMS gyro, these normal modes of vibration are plate rocking modes. The rocking motion of the plate is described by giving two angles, theta(sub 1) and theta(sub 2). A proof mass consisting of a post orthogonal to the plate ensures a high degree of Coriolis coupling of vibratory energy from one mode into the other under inertial rotation. The plate is driven and sensed capacitively across a few-microns-wide gap, and the normal mode frequencies can be tuned electrostatically by DC voltages applied across this gap. In order to sense rotation, the resonator plate is caused to rock in the theta(sub 1) direction, then any small motions in the theta(sub 2) direction are sensed, rebalanced, and interpreted as inertial rotation. In this scenario, the "drive" has been assigned to the theta(sub 1) direction, and the "sense" has been assigned to the theta(sub 2) direction.

Hayworth, Ken↗

State and model error estimation for distributed parameter systems

In-flight estimation of large structure model errors in order to detect inevitable deficiencies in large structure controller/estimator models is discussed. Such an estimation process is particularly applicable in the area of shape control system design required to maintain a prescribed static structural shape and, in addition, suppress dynamic disturbances due to the vehicle vibrational modes. The paper outlines a solution to the problem of static shape estimation where the vehicle shape must be reconstructed from a set of measurements discretely located throughout the structure. The estimation process is based on the principle of least-squares that inherently contains the definition and explicit computation of model error estimates that are optimal in some sense. Consequently, a solution is provided for the problem of estimation of static model errors (e.g., external loads). A generalized formulation applicable to distributed parameters systems is first worked out and then applied to a one-dimensional beam-like structural configuration.

Rodriguez, G.↗

Analysis of a spatial tracking subsystem for optical communications

Spatial tracking plays a very critical role in designing optical communication systems because of the small angular beamwidth associated with the optical signal. One possible solution for spatial tracking is to use a nutating mirror which dithers the incoming beam at a rate much higher than the mechanical disturbances. A power detector then senses the change in detected power as the signal is reflected off the nutating mirror. This signal is then correlated with the nutator driver signals to obtain estimates of the azimuth and elevation tracking signals to control the fast scanning mirrors. A theoretical analysis is performed for a spatial tracking system using a nutator disturbed by shot noise and mechanical vibrations. Contributions of shot noise and mechanical vibrations to the total tracking error variance are derived. Given the vibration spectrum and the expected signal power, there exists an optimal amplitude for the nutation which optimizes the receiver performance. The expected performance of a nutator based system is estimated based on the choice of nutation amplitude.

Win, Moe Z.↗

Vibrational Stabilization of Flexible Structures

It has been demonstrated that a high frequency excitation (HFE) field significantly changes the fundamental properties of mechanical systems. The most important contribution of HFE is the stiffening effect of an elastic continuum in the direction of the wave vector. This effect allows control of stiffness in any selected direction by the corresponding changes in the intensity of HFE. This new approach can be effective for large flexible space structures. Such an approach may prove to be very practical in the sense that large structures need to be made as flimsy as possible for low cost under ordinary situations. However, for certain operations such as development, orbital transfer, docking, and other circumstances, it would be vital to have a means of temporarily stiffening certain structural members. If the structure was designed to meet these occasional loads without temporary stiffening, it would be considerably more massive and more expensive.

Zak, M.↗

Entry flight control system downmoding evaluation

A method to desensitize the entry flight control system to structural vibration feedback which might induce an oscillatory instability is described. Trends in vehicle response and handling characteristics as a function of gain combinations in the FCS forward and rate feedback loops were described as observed in a man-in-the-loop simulation. Among the flight conditions considered are the effects of downmoding with APU failures, off-nominal trajectory conditions, sensed angle of attack errors, the impact on RCS fuel consumption, performance in the presence of aero variations, recovery from large FCS upsets, and default gains.

Barnes, H. A.↗

Space structure vibration modes: How many exist? Which ones are important?

Several assertions are argued regarding mode analysis of structural vibration. The idea of a "mode' is, in essence, a mathematical one. It is highly unlikely that any real structure can vibrate exactly so that all its points move in unison; in other words, it is highly unlikely that any structure has any modes. As an approximation, however, the use of a mode is an excellent one for many structures, especially for the "lower modes'. The agreement between experiment and theory for the "higher modes' tends to become weaker. In this approximate sense, most structures have a very large number of modes. It is elementary to show, however, that no real structure has an infinite number of modes. The only utility of the "infinite modes' idea is within the purely mathematical domain. Many "error indices' can be defined as guidelines for structural modal order reduction. Simple modal truncation, although suggested by experience with slender rods, is naive. The proper process is mode selection, based on a appropriate error criterion.

Hughes, P. C.↗

Apparatus for providing vibrotactile sensory substitution of force feedback

A feedback apparatus for an operator to control an effector that is remote from the operator to interact with a remote environment has a local input device to be manipulated by the operator. Sensors in the effector's environment are capable of sensing the amplitude of forces arising between the effector and its environment, the direction of application of such forces, or both amplitude and direction. A feedback signal corresponding to such a component of the force, is generated and transmitted to the environment of the operator. The signal is transduced into a vibrotactile sensory substitution signal to which the operator is sensitive. Vibration producing apparatus present the vibrotactile signal to the operator. The full range of the force amplitude may be represented by a single, mechanical vibrator. Vibrotactile display elements can be located on the operator's limbs, such as on the hand, fingers, arms, legs, feet, etc. The location of the application of the force may also be specified by the location of a vibrotactile display on the operator's body. Alternatively, the location may be specified by the frequency of a vibrotactile signal.

Massimino, Michael J.↗

Tea ( Camellia sinensis ) Extract-Mediated Green Synthesis of Co 3 O 4 and Co 3 O 4 @Graphene Nanocomposites for Multifunctional Applications in Pollutant Degradation, Sensing, and Energy Storage

A novel solution-mixing method was proposed to synthesize Co 3 O 4 /graphene nanocomposites (Co 3 O 4 @Gr) using a green tea leaf (Camellia sinensis) extract as the reducing agent. XRD analysis shows that the as-prepared Co 3 O 4 @Gr exhibits a cubic spinel crystal structure. From morphological analysis, the obtained Co 3 O 4 NS forms spherical clusters that are uniformly distributed on the graphene surface. FT-IR and Raman analyses confirmed the strong molecular and vibrational interactions between the Co 3 O 4 NS and Gr. The suppressed PL intensity peak of the Co 3 O 4 @Gr NCs indicated significant inhibition in the recombination of charge carriers between the hybrid orbitals within the composites. As a result, the catalytic efficiency of Co 3 O 4 @Gr NCs increased to 80% compared to pristine Co 3 O 4 , which exhibited only 45% efficiency against methylene blue (MB) dye. Moreover, the as-prepared NCs exhibited a detection limit of 0.01−224 μM, demonstrating a superior low-DPA detection with high sensitivity. The Co 3 O 4 @Gr/GCE exhibits admirable selectivity for various pesticides, fungicides, and metal ions, with outstanding reproducibility and stability. From electrochemical investigations, the highest specific capacitance values of the as-synthesized Co 3 O 4 @Gr were 349 F/g at a scan rate of 5 mV/s and 158 F/g at a current density of 1 A/g.

Capacitors↗

Revealing subterahertz atomic vibrations in quantum paraelectrics by surface-sensitive spintronic terahertz spectroscopy

Understanding surface collective dynamics in quantum materials is crucial for advancing quantum technologies. For example, surface phonon modes in quantum paraelectrics are thought to be essential in facilitating interfacial superconductivity. However, detecting these modes, especially below 1 terahertz, is challenging because of limited sampling volumes and the need for high spectroscopic resolution. Here, we report surface soft transverse optical (TO1) phonon dynamics in KTaO 3 and SrTiO 3 by surface-sensitive spintronic terahertz spectroscopy that can sense the collective modes only a few nanometers deep from the surface. In KTaO 3 , the TO1 mode softens and sharpens with decreasing temperature, leveling off at 0.7 terahertz. In contrast, this mode in SrTiO 3 broadens substantially below the quantum paraelectric crossover and coincides with the hardening of a sub–milli–electron volt phonon mode related to the antiferrodistortive transition. These observations that deviate from their bulk properties may have implications for interfacial superconductivity and ferroelectricity. The developed technique opens opportunities for sensing low-energy surface collective excitations.

Chu, Zhaodong↗

Wall shear stress measurements using a new transducer

A new instrument has been developed for direct measurement of wall shear stress. This instrument is simple and symmetric in design with small moving mass and no internal friction. Features employed in the design of this instrument eliminate most of the difficulties associated with the traditional floating element balances. Vibration problems associated with the floating element skin friction balances have been found to be minimized by the design features and optional damping provided. The unique design of this instrument eliminates or reduces the errors associated with conventional floating-element devices: such as errors due to gaps, pressure gradient, acceleration, heat transfer and temperature change. The instrument is equipped with various sensing systems and the output signal is a linear function of the wall shear stress. Measurement made in three different tunnels show good agreement with theory and data obtained by the floating element devices.

Vakili, A. D.↗