Search NASA⌕ Search

SEARCH · Search NASA

Results for “vibrator array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

A space qualified thermal imaging system using a Pt Si detector array

EDO Corporation, Barnes Engineering Division designed and constructed a high resolution thermal imaging system on contract to Lockheed for use in the SDI Star Lab. This employs a Pt Si CCD array which is sensitive in the spectral range of 3 to 5 microns. Star Lab will be flown in the Shuttle bay and consists basically of a large, reflecting, tracking telescope with associated sensors and electronics. The thermal imaging system is designed to operate in the focal plane of this telescope. The configuration of the system is illustrated. The telescope provides a collimated beam output which is focussed onto the detector array by a silicon objective lens. The detector array subtends a field of view of 1.6 degrees x 1.22 degrees. A beam switching mirror permits bypassing the large telescope to give a field of 4 degrees x 3 degrees. Two 8 position filter wheels are provided, and background radiation is minimized by Narcissus mirrors. The detector is cooled with a Joule-Thompson cryostat fed from a high pressure supply tank. This was selected instead of a more convenient closed-cycle system because of concern with vibration. The latter may couple into the extremely critical Starlab tracking telescope. The electronics produce a digitized video signal for recording. Offset and responsivity correction factors are stored for all pixels and these corrections are made to the digitized output in real time.

Astheimer, Robert W.↗

Phase Change Materials for Photonics in NASA Science and Space Missions

Phase change materials (PCMs) such as Ge2Sb2Te5, Ge2Sb2Se4Te1, and Sb2S3have recently emerged as a promising platform to control light on-chip due to their fast, dramatic, and reversible change in refractive index. Significant technical progress in the field has been achieved in terms of improving optical transparency, controlling PCMs both optically and electrically, and integrating with complex photonic circuits, leading to exciting applications. When PCMs are mated with metasurfaces, devices are capable of controlling the phase and amplitude of propagating light with arrays of subwavelength structures. These enhance tunability and reconfigurability and continue to redefine the boundaries of optical sciences. PCM-based metasurface optics also help to accelerate the adoption of new architectures with reduced size, weight, and power (SWaP) for science and space mission platforms at NASA. In this talk, I will introduce two NASA-lead PCM photonic projects: 1. P-ACTIVE (PCM-based actively tunable filter) for broad imaging and sensing applications – from probing molecular vibrations in chemical species to detecting radiant thermal signatures of the space launch system. 2. PROWESS (Phase change reconfigurable optical wavefront synthesis system) as a beam steerer for both Earth and space LiDAR and free space optical communication applications. From this seminar, the attendees will be exposed not only to PCM-based photonic technologies but also NASA missions including the MISSE (Materials on the International Space Station Experiment) test campaign that was conducted to expose PCMs and PCM-based metasurfaces in space for 6 months in 2022.

phase change material↗

Insight into the Selectivity of Isopropanol Conversion at Strontium Titanate (100) Surfaces: A Combination Kinetic and Spectroscopic Study

This work aims to better understand the role of interfacial molecular structure that governs selectivity and activity in heterogeneous catalytic reactions. To address this, a comprehensive study of isopropanol conversion over an archetypal perovskite material, strontium titanate (SrTiO 3 or STO), was performed with an array of techniques sensitive to orthogonal aspects of the ensuing chemistry. Cubic-shape STO nanoparticles with only the (100) facet exposed were synthesized and used to study the ensemble kinetic conversion of isopropanol over the surfaces, which showed a remarkable selectivity to form acetone, with minor propylene products appearing at elevated temperatures. These results in combination with inelastic neutron scattering measurements provide not only new insight into the selectivity and overall activity of the catalysts but also low frequency vibrational signatures of the adsorbed and reacted species. To compliment these measurements, pristine thin films of STO (100) were synthesized and used in combination with vibrational sum frequency generation spectroscopy to extract the absolute molecular orientation of the adsorbed molecules at the interface. It was found that the isopropanol assumes an orientation where the -CH group points towards the STO surface; this pre-reaction geometry offers an obvious pathway to produce acetone by abstracting the alpha-proton and, thus, provides a mechanistic explanation of selectivity at STO (100) surfaces. This new insight opens up pathways to explore and modify surfaces to tune the activity/selectivity though a molecular level understanding of the reactions at the surface.

36 MATERIALS SCIENCE↗

Hybrid Metasurface-Based Mid-Infrared Biosensor for Simultaneous Quantification and Identification of Monolayer Protein

Metasurfaces emerge as a promising photonic platform for biosensing because they offer strong optical confinement and tunable optical resonances. Here, we show that metasurface-based biosensors consisting of gold nanoantenna arrays loaded with graphene and working in the mid-infrared (mid-IR) spectral range can achieve simultaneous high-sensitivity and high-specificity detection of biomolecules. Strong light–molecule interactions in deeply subwavelength optical spots created by the biosensors allow us to determine the concentration of protein molecules via spectral shifts of the metasurface resonance. A combination of passive and active tuning of the metasurface sensors allows us to spectrally overlap the metasurface resonance and the protein vibrational modes, so that protein molecules can be identified via their characteristic mid-IR “fingerprints”. As a result, the high sensitivity and specificity of the metasurface sensors enable us to determine the secondary structure of protein immunoglobulin (IgG) molecules 4 orders of magnitude more sensitive than attenuated total reflection Fourier transform infrared spectroscopy.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

The AXAF/XRS test dewar - A versatile design

The X-Ray Spectrometer (XRS) to be flown on the Advanced X-ray Astrophysics Facility (AXAF) consists of an array of microcalorimeters and an Adiabatic Demagnetization Refrigerator (ADR). The ADR provides an operating temperature of 0.065 to 0.100 K. To support extensive development testing of the ADR and the detector array, a test dewar has been designed and built that surpasses specification requirements. Pumping on the liquid helium bath with a 47 l/s pump, we have achieved temperatures lower than 1.5 K with a hold time in excess of 72 hrs. The dewar can be operated without liquid nitrogen with a hold time of 36 hrs. This feature was incorporated in the design because boiling nitrogen may introduce microphonic noise to the detectors. To further reduce the susceptibility to microphonic vibration a unique suspension system utilizing Kevlar fibers was devised which provides both translational and rotational rigidity to the detector mount. Finally, the dewar is very manageable and may be rotated by only one person.

Weintz, Karl F.↗

Microcoil Spring Interconnects for Ceramic Grid Array Integrated Circuits

As integrated circuit miniaturization trends continue, they drive the need for smaller higher input/output (I/O) packages. Hermetically sealed ceramic area array parts are the package of choice by the space community for high reliability space flight electronic hardware. Unfortunately, the coefficient of thermal expansion mismatch between the ceramic area array package and the epoxy glass printed wiring board limits the life of the interconnecting solder joint. This work presents the results of an investigation by Marshall Space Flight Center into a method to increase the life of this second level interconnection by the use of compliant microcoil springs. The design of the spring and its attachment process are presented along with thermal cycling results of microcoil springs (MCS) compared with state-of-the-art ball and column interconnections. Vibration testing has been conducted on MCS and high lead column parts. Radio frequency simulation and measurements have been made and the MCS has been modeled and a stress analysis performed. Thermal cycling and vibration testing have shown MCS interconnects to be significantly more reliable than solder columns. Also, MCS interconnects are less prone to handling damage than solder columns. Future work that includes shock testing, incorporation into a digital signal processor board, and process evaluation of expansion from a 400 I/O device to a device with over 1,100 I/O is identified.

Strickland, S. M.↗

Utilizing the US Lab Nadir Research Window for Remote Sensing Operations with The Window Observational Research Facility (WORF)

The Window Observational Research Facility (WORF) is an ISPR-based rack facility designed to take advantage of the high optical quality US Lab Nadir research window. The WORF is based on the ISS Expedite the Processing of Experiments to Space Station (EXPRESS) rack mechanical structure and electronic systems. The WORF has a unique payload volume located at the center of the rack that provides access to the window. The interior dimensions of the payload volume are 34-in. (86.36 cm) wide by 33-in. (83.82 cm) high by 23-in. (58.42 cm) deep. This facility supports the deployment of payloads such as 9 in. aerial photography cameras and 12 in. diameter optical equipment. The WORF coupled with the optical quality of the United States Lab window support the deployment of various payload disciplines. The WORF provides payloads with power, data command and control, air cooling, water cooling, and video processing. The WORF's payload mounting surfaces and interfaces include the interior payload mounting shelf and the interior and exterior aircraft-like seat tracks. The payload mounting shelf is limited to a maximum mass of 136 kg (299 pounds). The WORF can accommodate large payloads such as the commonly used Leica-Heerbrug RC-30 aerial photography camera (whose dimensions are 53.3 cm (21-in.) wide by 50.8 cm (20-in.) deep by 76.2 cm (30-in.) long). The performance characteristics of the WORF allow it to support an array of payload disciplines. The WORF provides a maximum of 3 Kw at 28 Vdc and has a maximum data rate of 10 Mbps. The WORF's unique payload volume is designed to be light-tight, down to 2.8 x 10(exp -11) Watts/cm2/steradian, and have low-reflective surfaces. This specially designed WORF interior supports payload investigations that observe low-light-level phenomenon such as aurora. Although the WORF rack does not employ any active rack isolation (i.e., vibration dampening) technology, the rack provides a very stable environment for payload operations (on the order of X microradians). The facility's software is capable of being updated during its period of deployment. The WORF project also includes a Suitcase Simulator to allow for a payload developer to verify data interfaces at his development site, a trainer rack for astronauts to learn how to operate the WORF prior to flight, and the use of the EXPRESS Functional Checkout Units to allow for payload checkout at the KSC prior to launch.

Turner, Richard↗

Seismic monitoring of a small CO 2 injection using a multi-well DAS array: Operations and initial results of Stage 3 of the CO 2 CRC Otway project

Active time-lapse seismic is widely employed for monitoring CO 2 geosequestration due to its ability to track the distribution of fluids in space and time. However, standard 4D seismic monitoring suffers from several challenges, including high cost, disruption to other land uses, and, consequently, relatively large intervals between monitor surveys. Some of these challenges can be mitigated using permanently installed sources and receivers. Such an approach was tested at the CO 2 CRC Otway site by continuous offset VSP monitoring of 15,000 t of supercritical CO 2 injected into an aquifer 1,500 m deep with nine permanent seismic sources (surface orbital vibrators or SOVs) and five downhole fibre-optic receivers. This continuous monitoring is complemented by multi-well 4D VSP using a mobile vibroseis source and the same DAS receivers, which included one baseline and two monitor surveys after injection of 4,000 and 12,000 t of CO 2 . The continuous DAS-SOV monitoring detected an abrupt increase of travel times below the injection interval on the second day of injection (after injection of 300 t of CO 2 ) and tracked the growth of the areal CO 2 plume by mapping changes of reflection amplitudes. The plume is also detected by time-lapse changes of reflection amplitudes in multi-well 4D VSPs. The plume images obtained from continuous offset VSP and 4D VSP are broadly consistent with each other but with some differences due to differences in illumination, lateral variations of velocities and seismic anisotropy. Furthermore, these differences also serve as a measure of uncertainty of 4D VSP images.

4D VSP↗

NASA Tech Briefs, July 2013

Dielectrophoresis-Based Particle Sensor Using Nanoelectrode Arrays; Multi-Dimensional Damage Detection for Surfaces and Structures; ULTRA: Underwater Localization for Transit and Reconnaissance Autonomy; Autonomous Cryogenic Leak Detector for Improving Launch Site Operations; Submillimeter Planetary Atmospheric Chemistry Exploration Sounder; Method for Reduction of Silver Biocide Plating on Metal Surfaces; Silicon Micromachined Microlens Array for THz Antennas; Forward-Looking IED Detector Ground Penetrating Radar; Fully Printed, Flexible, Phased Array Antenna for Lunar Surface Communication, Battery Charge Equalizer with Transformer Array; An Efficient, Highly Flexible Multi-Channel Digital Downconverter Architecture; Dimmable Electronic Ballast for a Gas Discharge Lamp; Conductive Carbon Nanotube Inks for Use with Desktop Inkjet Printing Technology; Enhanced Schapery Theory Software Development for Modeling Failure of Fiber-Reinforced Laminates; High-Performance, Low-Temperature-Operating, Long-Lifetime Aerospace Lubricants; Carbon Nanotube Microarrays Grown on Nanoflake Substrates; Differential Muon Tomography to Continuously Monitor Changes in the Composition of Subsurface Fluids; Microgravity Drill and Anchor System; 20 Granular Media-Based Tunable Passive Vibration Suppressor; 21 Miga Aero Actuator and 2D Machined Mechanical Binary Latch; Micro-XRF for In Situ Geological Exploration of Other Planets; Hydrogen-Enhanced Lunar Oxygen Extraction and Storage Using Only Solar Power; Uplift of Ionospheric Oxygen Ions During Extreme Magnetic Storms; Miniaturized, High-Speed, Modulated X-Ray Source; Hollow-Fiber Spacesuit Water Membrane Evaporator 25 High-Power Single-Mode 2.65-micrometers InGaAsSb/AlInGaAsSb Diode Lasers; Optical Device for Converting a Laser Beam Into Two Co-aligned but Oppositely Directed Beams; A Hybrid Fiber/Solid-State Regenerative Amplifier with Tunable Pulse Widths for Satellite Laser Ranging; X-Ray Diffractive Optics; SynGenics Optimization System (SynOptSys); 29 CFD Script for Rapid TPS Damage Assessment; radEq Add-On Module for CFD Solver Loci-CHEM; Science Opportunity Analyzer (SOA) Version 8; 30 Autonomous Byte Stream Randomizer; Distributed Engine Control Empirical/Analytical Verification Tools; Dynamic Server-Based KML Code Generator Method for Level-of-Detail Traversal of Geospatial Data; Automated Planning of Science Products Based on Nadir Overflights and Alerts for Onboard and Ground Processing; Linked Autonomous Interplanetary Satellite Orbit Navigation; Risk-Constrained Dynamic Programming for Optimal Mars Entry, Descent, and Landing; Scheduling Operations for Massive Heterogeneous Clusters; Deepak Condenser Model (DeCoM); Flight Software Math Library; Recirculating 1-K-Pot for Pulse-Tube Cryostats; 35 Method for Processing Lunar Regolith Using Microwaves; Wells for In Situ Extraction of Volatiles from Regolith (WIEVR); and Estimating the Backup Reaction Wheel Orientation Using Reaction Wheel Spin Rates Flight Telemetry from a Spacecraft.

Source record↗

Numerical evaluation of the radiation from unbaffled, finite plates using the FFT

An iteration technique is described which numerically evaluates the acoustic pressure and velocity on and near unbaffled, finite, thin plates vibrating in air. The technique is based on Rayleigh's integral formula and its inverse. These formulas are written in their angular spectrum form so that the fast Fourier transform (FFT) algorithm may be used to evaluate them. As an example of the technique the pressure on the surface of a vibrating, unbaffled disk is computed and shown to be in excellent agreement with the exact solution using oblate spheroidal functions. Furthermore, the computed velocity field outside the disk shows the well-known singularity at the rim of the disk. The radiated fields from unbaffled flat sources of any geometry with prescribed surface velocity may be evaluated using this technique. The use of the FFT to perform the integrations in Rayleigh's formulas provides a great savings in computation time compared with standard integration algorithms, especially when an array processor can be used to implement the FFT.

Williams, E. G.↗

Long-slit Spectra of the Red Rectangle at 3 Microns

We have observed the Red Rectangle with the Cryogenic Spectrometer (CRSP) at the 2.1 m telescope of Kitt Peak National Observatory. The Red Rectangle is a well-known source of the infrared emission features associated with polycyclic aromatic hydrocarbons (PAHs). Our long-slit spectra cover the 3.2-3.6 micrometer regime, which includes the strong PAH band at 3.29 micrometers, a weaker component at 3.40 micrometers, and an emission plateau which continues out to 3.6 micrometers. Emission in the PAH bands extends several arcseconds to the north and south of the central source (HD 44179). The seeing during our observations was approximately 1.5 arcseconds, but we have deconvolved the point spread function from our spectral images at each wavelength using maximum entropy reconstruction, allowing us to examine the relative behavior of these emission components at finer spatial scales. With the new 256x256 array installed on CRSP, each pixel covers 0.6 arcseconds of sky. Our reconstructions reveal that the strength of the small 3.4 micrometer emission feature increases with respect to the 3.3 micrometer feature as the distance from the central source increases. In particular, there appears to be a region of enhanced 3.4 micrometer emission roughly 3" to the north and south of the central source. We are analyzing our results in terms of the competing models for the origin of the 3.4 micrometer emission feature, which could be a vibrational overtone of the 3.3 micrometer feature, or could result from the attachment of molecular sidegroups to the PAH molecule.

Sloan, G. C.↗

A Search for Structure in PAH Emission in Extended Sources at 3.3 and 3.4 Microns

We have observed three extended sources of the infrared emission features associated with polycyclic aromatic hydrocarbons (PAHs), using a 128x128 InSb array mounted on the 1.5 m NASA/Steward telescope on Mt. Lemmon. We used a CVF (1.5% bandpass) to isolate the emission from the 3.29 and 3.40 microns PAH features in NGC 1333 #3, Sharpless 106, and the Orion Bar. In all three sources, the 3.29 and 3.40 microns emission features arise from the same regions, but show decidedly different structure. We are analyzing the images to determine the relationship of the 3.40 microns feature to the main feature at 3.29 microns. The 3.40 microns feature may be a vibrational overtone of the 3.29 microns feature, or it may arise from attached molecular sidegroups.

Bregman, Jesse↗

Optical design and synthetic analysis of the electron cyclotron emission imaging diagnostic of HL-2M tokamak

The electron cyclotron emission imaging (ECEI) diagnostic is a powerful tool to study the MHD and turbulent transport in magnetically confined fusion plasmas. In this work, the optical system including the local oscillator (LO) coupling and radio frequency (RF) receiving optics, has been designed and analyzed for the HL-2M ECEI diagnostic. The LO optics can illuminate the antenna array and drive the mixer diode to work efficiently, with more than 36% of the beam intensity for the channels which probe the plasma edge relative to those of channels which probe the plasma core. The RF optics aims at guiding the plasma emission signal to the antenna array. To meet different physical requirements, three types of field of view have been achieved for the plasma imaging, with zoom factors of around 1, 1.5 and 2, respectively. The focal surfaces are almost flat, with a maximum off-mapping (defined as the radial distance between the beam waists of the lower-/uppermost antennas and electron cyclotron emission layer) less than 2.5 cm, which can match the electron cyclotron emission layer quite well and suppress the image distortion in the plasma edge region. Furthermore, the impact of possible vibrations and installation error on the focal plane has been evaluated. In addition, the predefined MHD and turbulence perturbations are well reproduced by combining the optical simulation results and synthetic ECEI modeling, which further verifies the good performance of the RF optics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Structure of 0 + excitations in the mass A ≈ 100 region: 0 2 + bands in Sr 98 and Zr 100

0 + 2 bands in 98 Sr and 100 Zr, populated in spontaneous fission of 248 Cm and 252 Cf, have been studied using the Eurogam2 and Gammasphere arrays. Phenomenological classification of excited 0 + levels in even-even nuclei of the A ≈ 100 region into four categories is presented and an interpretation for each category is proposed. Highly deformed 0 + 1 ground states and low-energy 0 + 2 levels in both nuclei are probably due to the 2p-2h excitation of two neutrons from the 9/2 + [404] extruder to the low-Ω prolate and the 11/2 – [505] oblate orbitals originating from the h 11/2 shell, respectively. As a result, candidates for 0 + , β vibrational states in A ≈ 100 region are suggested at N > 60.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Detection and Association of Operational Events using DAS and Seismometers (FY 2025 Mid-Year Report)

This mid-year report summarizes ongoing work to identify anomalous vibration signals indicative of potential containment breaches. This work includes compiling continuous seismic datasets and testing and refining underground detection and geolocation techniques. In the first two quarters of FY25, we have completed two project work plan tasks: (1) creating a database of continuous waveforms and ground truth event data from multiple modalities and (2) refining and implementing a detection and association algorithm to create a catalog of anomalous underground activities. This report contains a summary of the seismic database including the continuous seismic data collected by a dense array of surface seismic stations above Pleasant Gap Mine, and continuous seismic data collected using subsurface distributed acoustic sensing (DAS) in the subsurface at Sanford Underground Research Facility (SURF) and the ground truth information gathered from both sites. This report also includes results from refining and applying a dynamic power spectral density detector to both continuous seismic datasets. Finally, the report provides an initial catalog of subsurface operational events from both sensing modalities.

58 GEOSCIENCES↗

MEMS Microshutter Array System for James Webb Space Telescope

A complex MEMS microshutter array system has been developed at NASA Goddard Space Flight Center (GSFC) for use as a multi-object aperture array for a Near-Infrared Spectrometer (NIRSpec). The NIRSpec is one of the four major instruments carried by the James Webb Space Telescope (JWST), the next generation of space telescope after the Hubble Space Telescope retires. The microshutter arrays (MSAs) are designed for the selective transmission of light with high efficiency and high contrast. It is demonstrated in Figure 1 how a MSA is used as a multiple object selector in deep space. The MSAs empower the NIRSpec instrument simultaneously collect spectra from more than 100 targets therefore increases the instrument efficiency 100 times or more. The MSA assembly is one of three major innovations on JWST and the first major MEMS devices serving observation missions in space. The MSA system developed at NASA GSFC is assembled with four quadrant fully addressable 365x171 shutter arrays that are actuated magnetically, latched and addressed electrostatically. As shown in Figure 2, each MSA is fabricated out of a 4' silicon-on-insulator (SOI) wafer using MEMS bulk-micromachining technology. Individual shutters are close-packed silicon nitride membranes with a pixel size close to 100x200 pm (Figure 3). Shutters are patterned with a torsion flexure permitting shutters to open 90 degrees with a minimized mechanical stress concentration. In order to prevent light leak, light shields are made on to the surrounding frame of each shutter to cover the gaps between the shutters and the Game (Figure 4). Micro-ribs and sub-micron bumps are tailored on hack walls and light shields, respectively, to prevent sticktion, shown in Figures 4 and 5. JWST instruments are required to operate at cryogenic temperatures as low as 35K, though they are to be subjected to various levels of ground tests at room temperature. The shutters should therefore maintain nearly flat in the entire temperature range between 35K and 300K. Through intensive numerical simulations and experimental studies, an optically opaque and electrically conductive metal-nitride thin film was selected as a coating material deposited on the shutters with the best thermal-expansion match to silicon nitride - the shutter blade thin film material. A shutter image shown in Figure 6 was taken at room temperature, presenting shutters slightly bowing down as expected. Shutters become flat when the temperature decreases to 35K. The MSAs are then bonded to silicon substrates that are fabricated out of 6" single-silicon wafers in the thickness of 2mm. The bonding is conducted using a novel single-sided indium flip-chip bonding technology. Indium bumps fabricated on a substrate are shown in Figure 7. There are 180,000 indium bumps for bonding a flight format MSA array to its substrate. Besides a MSA, each substrate houses five customer-designed ASIC (Application Specific Integrated Circuit) multiplexer/address chips for 2-dimensional addressing, twenty capacitors, two temperature sensors, numbers of resistors and all necessary interconnects, as shown in Figure 8. Complete MSA quadrant assemblies have been successfully manufactured and fully functionally tested. The assemblies have passed a series of critical reviews required by JWST in satisfying all the design specifications. The qualification tests cover programmable 2-D addressing, life tests, optical contrast tests, and environmental tests including radiation, vibration, and acoustic tests. A 2-D addressing pattern with 'ESA' letters programmed in a MSA is shown in Figure 9. The MSAs passed 1 million cycle life tests and achieved high optical contrast over 10,000. MSA teams are now making progress in final fabrication, testing and assembly (Figure 10). The delivery of flight-format MSA system is scheduled at the end of 2008 for being integrated to the focal plane of the NIRSpec detectors.

Li, Mary J.↗

Enhanced light–matter interaction of aligned armchair graphene nanoribbons using arrays of plasmonic nanoantennas

We couple photoluminescent semiconducting 7-atom wide armchair edge graphene nanoribbons to plasmonic nanoantenna arrays and demonstrate an enhancement of the photoluminescence and Raman scattering intensity of the nanoribbons by more than an order of magnitude averaged over large areas, and by three orders of magnitude in the hot spots of plasmonic antennas. The increase in signal allows us to study Raman spectra with high signal-to-noise ratio. Using plasmonic enhancement we are able to detect the off-resonant Raman scattering from the modified radial breathing-like mode (RBLM) due to physisorbed molecules, the 3rd order RBLM, and C-H vibrations. We find excellent agreement between experimental data and simulations describing the spectral dependence of the enhancement and modifications of the polarization anisotropy. The strong field gradients in the optical near-field further allow us to probe the subwavelength coherence properties of the phonon modes in the nanoribbons. We theoretically model this considering a finite phonon correlation length along the GNR direction. Our results allow estimating the correlation length in graphene nanoribbons.

36 MATERIALS SCIENCE↗

Rationale for an experimental test for flexible space structure attitude control

The problems of large flexible spacecraft control are characterized by the infinite bandwidth of structural vibrations, which cannot be accounted for in the dynamic design model. This may lead to instability even, if ideal control hardware is assumed, which can be concluded from preceding numerical investigations. Additional performance limitations are expected to occur due to hardware constraints. A laboratory experiment is proposed to investigate the key problems in more detail. The test setup requirements being defined by the idealized control system are extremely high demanding a high speed processor and special hardware component developments. The test element is a wire suspended plate being controlled by an array processor via high performance sensors and actuators. First tests on component level indicate the feasibility of the system presently being developed.

Lange, T.↗