Search NASA⌕ Search

SEARCH · Search NASA

Results for “voltage measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

An Open Source Perovskite Solar Cell Curve Tracer

When developing systems for perovskite solar cells (PSCs), it is important to have a testing platform that closely resembles your deployed systems. While developing a 1 U CubeSat, the Big Red Sat-1 at the University of Nebraska-Lincoln, we found a lack of passive curve tracing instrumentation, which we needed for our mission. To that end, we developed a benchtop passive curve tracer that leverages the Ossila Solar Simulator as an AM1.5 light source. This device utilizes a ladder of switched resistors and a precision voltage and current measurement to achieve the curve tracing. It also integrates a common-anode multiplexer to switch through multipixel PSCs. Finally, the solar cell holder is separate from the main measurement system, so various substrates sizes and pixel counts can be supported. This system is tested using various PSCs. It has been open sourced to enable reuse in future systems that may benefit from the lower power consumption and flight heritage.

14 SOLAR ENERGY↗

Decentralized Carrier Phase Shifting for Optimal Harmonic Minimization in Asymmetric Parallel-Connected Inverters

This paper presents a carrier phase shifting technique for minimizing the aggregate harmonics in networks of asymmetric parallel-connected inverters for distributed power generation system applications. The proposed technique is: 1) implemented in a decentralized manner, relying only on local voltage and current measurements, and 2) optimal in the sense that it minimizes a cost function representing the carrier-frequency current harmonics. The analysis indicates that the proposed optimal carrier phase shifting technique can enable order-of-magnitude reductions in harmonic power, and also universal improvements compared to symmetric carrier interleaving for asymmetric inverter networks. Moreover, compared to existing methods that require either centralized communication or information exchange between inverters to coordinate carriers, the proposed technique is completely decentralized, which provides important practical benefits for implementation, including improved robustness and reduced cost. The technique is experimentally validated on a network of three single-phase 2-kW inverters and demonstrates a 36.5% reduction in the weighted total harmonic distortion factor of the aggregate inverter current, and the ability to converge to the optimal carrier phase spacing dynamically in less than one line frequency cycle (16.7 ms) in steady state and transient operating conditions.

42 ENGINEERING↗

Investigating Effects of Operational Parameters on the Rate of Electrochemical Cleaning of Chromium Deposits on Strontium-Doped Lanthanum Manganite Cathodes in Solid Oxide Fuel Cells

Chromium poisoning of the cathode remains a significant obstacle to the stable long-term performance of solid oxide fuel cells. This study reports, a quick, in-situ mitigation method, called electrochemical cleaning. By applying a mild anodic bias, the electrochemical deposition reactions of chromium-containing species are reversed. Chromium vapor species are formed, freeing active electrochemical sites in the air electrode. An LSM/YSZ-based cell was exposed to Cr vapors at 800ºC and then subjected to electrochemical cleaning. Cell performance recovery was evidenced by current-voltage and EIS measurements. Chromium removal was verified using SEM and EDS analyses. The cyclability of the electrochemical cleaning was tested by repeated poisoning and cleaning of another cell. Investigation into the effect of cell operating parameters (current density and cell temperature) on the rate of cleaning is discussed.

30 DIRECT ENERGY CONVERSION↗

Void-free Copper Electrodeposition in High Aspect Ratio, Full Wafer Thickness Through-Silicon Vias with Endpoint Detection

High density interconnects are required for increased input/output for microelectronics applications, incentivizing the development of Cu electrochemical deposition (ECD) processes for high aspect ratio through-silicon vias (TSVs). This work outlines Cu ECD processes for 62.5 μ m diameter TSVs, etched into a 625 μ m thick silicon substrate, a 10:1 aspect ratio. Cu ECD in high aspect ratio features relies on a delicate balance of electrolyte composition, solution replenishment, and applied voltage. Implementing a CuSO 4 -H 2 SO 4 electrolyte, which contains suppressor and a low chloride concentration, allows for a tunable relationship between applied voltage and localized deposition in the vias. A stepped potential waveform was applied to move the Cu growth front from the bottom of the via to the top. Sample characterization was performed through mechanical cross-sections and X-ray computed tomography (CT) scans. The CT scans revealed small seam voids in the Cu electrodeposit, and process parameters were tuned accordingly to produce void-free Cu features. During the voltage-controlled experiments, measured current data showed a characteristic current minimum, which was identified as an endpoint detection method for Cu deposition in these vias. We believe this is the first report of this novel endpoint detection method for TSV filling.

42 ENGINEERING↗

Ambient Temperature Sodium Polysulfide Catholyte for Nonaqueous Redox Flow Batteries

This study reports a sodium polysulfide catholyte for nonaqueous redox flow batteries (RFBs). We demonstrate reversible capacities up to 200 mAh/gS with negligible fade over 250 cycles at room temperature for sodium polysulfide|biphenyl full cells containing Na + ß '' -Al 2 O 3 solid electrolyte (BASE) membranes. Interestingly, formation of insoluble S and Na 2 S 4 phases did not inhibit the catholyte's cycle life which is likely due to the low concentrations used in the lab-scale prototypes. 3-electrode galvanostatic AC impedance measurements demonstrate that voltage losses were dominated by charge transfer at the cathode, and relevant kinetic parameters (i.e., transfer coefficients and exchange current density) were calculated through a Tafel analysis. To the best of our knowledge, this is the first report applying such an impedance approach to nonaqueous RFBs. Overall, the use of low-cost active materials makes sodium polysulfide|biphenyl RFBs promising for long duration energy storage applications. Furthermore, if strategies are developed to increase the solubility of S and/or low order polysulfides (Na 2 S x , x ≤ 4), specific energies up to 100 Wh kg -1 (including combined mass of the anolyte and catholyte) can be achieved.

25 ENERGY STORAGE↗

Radioimaging for real-time tracking of high-voltage breakdown

Development of a radioimaging diagnostic for high-voltage component reliability testing and electrical breakdown computational model validation is described. Radioimaging has its roots in radio astronomy, where aperture synthesis (also known as synthesis imaging) has been utilized for decades to image radio sources far from Earth. Radioimaging as described herein, in contrast, seeks to image radio sources in close proximity to its receivers (i.e., in a laboratory environment). Here it is shown that corona discharge, a non-destructive precursor to catastrophic (thermal) arc discharge, electromagnetically radiates strongly within a 250 kHz – 2.5 GHz bandwidth, and is readily detected and located by postprocessing the received radio signals. The ability of radioimaging to detect both corona and arc discharge (grouped together herein as high voltage breakdown or HVB) makes it a valuable tool for 100% HVB detection in materials, components, and devices, and has the ability to indicate electrical weakness (via corona detection) prior to a destructive arc discharge event. Radioimaging enables HVB to be located both internal and external to dielectric components under test in near-real-time, with multiple and/or extended HVB events located simultaneously. In contrast, existing non-destructive diagnostics (at the time of this writing) either indicate electrical breakdown without resolving failure locations (e.g., current, voltage, and chemical measurements), locate external HVB (e.g., high-speed optical and ultraviolet (UV) measurements or photography), or locate both external and internal HVB but with low fidelity (e.g., a single HVB source can be located by existing time-of-arrival (TOA) UHF or acoustic emissions). Radioimaging instead creates a sequence of high-fidelity images similar to an optical high-speed camera but at radiofrequencies (RF), and is not limited to two-dimensions. Moreover, radioimaging has already served one internal and two external industry customers, the results of which are detailed in this report. The radioimaging results described herein were part of a three-year effort funded by the Sandia Lab Directed Research and Development (LDRD) program within the Radiation, Electromagnetic, High Energy Density Science (REHEDS) investment area.

47 OTHER INSTRUMENTATION↗

20 kV Gallium Nitride pn Diode Electro-Magnetic Pulse Arrestor for Grid Reliability (Final Scientific/Technical Report)

This project developed vertical Gallium Nitride (GaN) pn diodes under two main thrusts: (1) A focus on relatively higher-voltage devices for use as fast EMP arrestors to protect the electric grid; and (2) A focus on a Foundry effort to establish the manufacturability of relatively lower voltage devices. For the first thrust, the aim was to develop devices that go into avalanche breakdown to clamp the voltage across sensitive grid equipment subject to voltage transients induced by electromagnetic pulses (EMPs). Devices with breakdown voltages exceeding 6.5 kV were achieved, and breakdown times shorter than 1 ns were demonstrated, which is sufficiently fast to protect against the fast component of an EMP-induced signal. Key challenges included the epitaxial growth of thick (50 µm or more), low-doped (low 10 15 cm -3 range) GaN layers comprising the drift regions of the diodes, as well as the design and fabrication of edge termination structures (step-etched junction termination extensions) to prevent premature breakdown. Midway through the project, an additional emphasis was put on large-area, high-current devices, and forward currents of approximately 400 A were achieved in composite devices towards the end of the project. Experimental and theoretical studies of impact ionization and avalanche ruggedness were also conducted. For the second thrust (the Foundry), the focus was primarily on 1.2-kV-class devices, although towards the end of the project outstanding results on 3.3-kV class devices were also achieved. The aim of the Foundry was to develop a high-yield, reliable, and economic vertical GaN pn diode process. The Foundry conducted characterization of incoming epitaxial material and correlated this information with the yield and performance of fully processed devices. Wafer maps of diode characteristics such as forward and reverse current as well as capacitance-voltage curves were measured using auto-probing. Several mask sets comprising different-area devices as well as multiple edge termination designs (implanted junction termination extensions, guard rings, and combinations thereof) were studied, and machine-learning-based approaches were utilized to analyze the data. Packaging and reliability efforts were also undertaken for the Foundry diodes, which are necessary for a viable commercial process.

20KV↗

20 kV Gallium Nitride pn Diode Electro-Magnetic Pulse Arrestor for Grid Reliability (Final Report)

This project developed vertical Gallium Nitride (GaN) pn diodes under two main thrusts: (1) A focus on relatively higher-voltage devices for use as fast EMP arrestors to protect the electric grid; and (2) A focus on a Foundry effort to establish the manufacturability of relatively lower-voltage devices. For the first thrust, the aim was to develop devices that go into avalanche breakdown to clamp the voltage across sensitive grid equipment subject to voltage transients induced by electromagnetic pulses (EMPs). Devices with breakdown voltages exceeding 6.5 kV were achieved, and breakdown times shorter than 1 ns were demonstrated, which is sufficiently fast to protect against the fast component of an EMP-induced signal. Key challenges included the epitaxial growth of thick (50 um or more), low-doped (low 10 15 cm -3 range) GaN layers comprising the drift regions of the diodes, as well as the design and fabrication of edge termination structures (step-etched junction termination extensions) to prevent premature breakdown. Midway through the project, an additional emphasis was put on large-area, high-current devices, and forward currents of approximately 400 A were achieved in composite devices towards the end of the project. Experimental and theoretical studies of impact ionization and avalanche ruggedness were also conducted. For the second thrust (the Foundry), the focus was primarily on 1.2-kV-class devices, although towards the end of the project outstanding results on 3.3-kV-class devices were also achieved. The aim of the Foundry was to develop a high-yield, reliable, and economic vertical GaN pn diode process. The Foundry conducted characterization of incoming epitaxial material and correlated this information with the yield and performance of fully processed devices. Wafer maps of diode characteristics such as forward and reverse current as well as capacitance-voltage curves were measured using auto-probing. Several mask sets comprising different-area devices as well as multiple edge termination designs (implanted junction termination extensions, guard rings, and combinations thereof) were studied, and machine-learning-based approaches were utilized to analyze the data. Packaging and reliability efforts were also undertaken for the Foundry diodes, which are necessary for a viable commercial process.

24 POWER TRANSMISSION AND DISTRIBUTION↗

PNNL DSSE Docker Image

This is the docker image for Pacific Northwest National Laboratory's DSSE (distribution system state estimator) used for the demo of OEDI-SI platform. To support the operation of modern distribution systems, operators require real-time visibility into system states. Due to a lack of measurements and unbalanced operation, the state estimation in distribution systems is challenging. This submission is related to an OEDI-SI use case which demonstrates the application of an extended Kalman filter-based state estimator on an IEEE-123 bus system. The state estimator uses the measurements to generate voltage estimates for the system.

Array↗

Enhancement of Photoemission on p-Type GaAs Using Surface Acoustic Waves

We demonstrate that photoemission properties of p-type GaAs can be altered by surface acoustic waves (SAWs) generated on the GaAs surface due to dynamical piezoelectric fields of SAWs. Multiphysics simulations indicate that charge-carrier recombination is greatly reduced, and electron effective lifetime in p-doped GaAs may increase by a factor of 10× to 20×. It implies a significant increase, by a factor of 2× to 3×, of quantum efficiency (QE) for GaAs photoemission applications, like GaAs photocathodes. Conditions of different SAW wavelengths, swept SAW intensities, and varied incident photon energies were investigated. Essential steps in SAW device fabrication on a GaAs substrate are demonstrated, including deposition of an additional layer of ZnO for piezoelectric effect enhancement, measurements of current–voltage (I–V) characteristics of the SAW device, and ability to survive high-temperature annealing. Results obtained and reported in this study provide the potential and basis for future studies on building SAW-enhanced photocathodes, as well as other GaAs photoelectric applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Methods and systems for detection of man-in-the-middle attacks for SCADA communication networks and applications of same

A system for detecting MITM for SCADA communication networks includes secure substation-substation communication links for providing secure and reliable paths to exchange OT data between substations for OT data consistency check; a SIB in each substation for sampling CT and PT measurements to calculate voltage magnitude and phase angle thereof; a S&C server in each substation coupled to the SIB for receiving the voltage magnitude and phase angle from the SIB and obtaining a packet carrying active power flow in transmission lines between two substations and a time stamp; an IDS server placed in a SCADA center for collecting the packet of each substation sent by the S&C server; analyzing the received packet from every adjacent substation; inspecting the payload of the received packet; and triggering an intrusion alarm to a SCADA operator when the power flow is not the same as the payload of the packets.

McCann, Roy A.↗

Optical device for in-line and real-time monitoring of microorganisms

A multi-wavelength laser diode based optical sensor system capable of monitoring the dynamics and physiological changes of a microorganism culture in real-time. The microorganism culture from a microorganism production chamber is pumped to a flow chamber. Laser diodes emit light at certain wavelengths through the flow chamber, which is sensed by photodiodes. A laser control circuitry is operatively connected to the laser diodes and a signal conditioning circuitry is operatively connected to the photodiodes. A microprocessor reads and records voltage signals corresponding to the wavelengths. A data acquisition system converts said voltage signals into measurements of biological parameters, which are displayed on a graphical user interface and allow a user to monitor the measurements in real time.

47 OTHER INSTRUMENTATION↗

Health Assessment and Performance Monitoring of Large Machine Diagnostics

Diagnostic machines are a crucial component of the Stockpile Stewardship Program for data collection, toward the ultimate goal of improving our understanding of nuclear physics. These systems consist of interactions between many complex components, and require regular maintenance for acceptable performance. The Cygnus X-ray diagnostic located at the Nevada National Security Site's U1a underground facility which provides radiographic data for subcritical experiments, is a prime example of these systems. Component degradation and failures within Cygnus can result in system downtime and data loss, affecting schedules and increasing experiment costs. To evade such failures, years worth of data on machine performance has been collected on the two Cygnus axes in the form of voltage and current measurements of Cygnus' various components. Using these as input, we have developed machine learning techniques for assessing the health of Cygnus, with the ultimate goal of predicting declining performance and machine failure.

97 MATHEMATICS AND COMPUTING↗

SVM-Based Synchronized Fault Detection for 100% Renewable Microgrids: Preprint

Traditional protection schemes face significant challenges when applied to microgrids with high penetrations of renewables with inverter-based resources (IBRs). The proliferation of advanced sensing and communication technologies has generated copious data, offering an opportunity to overcome these limitations using data-driven machine learning approaches. This work proposes a novel approach based on a support vector machine (SVM) for detecting faults within a 100% renewable microgrid. The approach encompasses a systematic offline training stage for the development of a linear SVM-based fault detection algorithm. This process covers offline data collection from the microgrid under study, the extraction of features such as positive- and negative-sequence components and the total harmonic distortion of the voltage and current measurements of the relays, and the design of the linear SVM-based classifier. During the online implementation, however, different classifiers can exhibit asynchronicity in detecting the fault inception at different subcycle-to-cycle period-level delays. To circumvent this asynchronicity issue, a separate algorithm is developed for each relay to estimate the fault inception time as close to the real fault time. The performance of the proposed SVM-based synchronized fault detection method is evaluated using online time-domain simulation studies on a microgrid test system. The results corroborate the reliability of the fault detection scheme when tested under various fault cases (fault types, locations, and impedances) and non-fault cases during both grid-tied and islanded operation modes.

100% microgrid↗

MULTI-FIDELITY MODELING AND UNCERTAINTY QUANTIFICATION OF INVERTER BASED RESOURCES IN INTEGRATED T&D SYSTEMS

Uncertainty quantification plays a pivotal role in improving the accuracy and reliability of inverter operation within modern power systems that are increasingly dominated by inverter-based resources (IBRs). IBRs, especially those operating under grid forming (GFM) control, rely heavily on a complex set of control parameters and system measurements to maintain voltage, frequency, and power balance. Traditional deterministic modeling approaches often fail to capture these parameter deviations, potentially resulting in suboptimal control actions, reduced system stability, or even instability under high penetration of IBRs. In this paper, we demonstrate the application of model calibration and uncertainty quantification (UQ) principles to an integrated transmission and distribution (T&D) model involving a GFM converter and provide a framework for prioritizing control improvements, guiding robust design, and informing adaptive strategies that can accommodate real-time variability in system conditions. The proposed approach could be valuable in enhancing the robustness of current and future power systems under increased IBR penetrations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sensors with Intelligent Measurement Platform and Low-cost Equipment (SIMPLE) for Monitoring and Control of Medium Voltage Distribution Systems with High Penetration of Intermittent Distributed Energy Resources

The primary focus of the SIMPLE project was to develop, commission, test and introduce intelligent voltage and current sensor platform with enhanced characteristics (accuracy, bandwidth and harmonic range) and high measurement granularity for medium voltage distribution system monitoring, protection and control. The enhancements incorporated existing (commercially available) sensors and made them suitable for applications such as voltage regulation, frequency support, fault detection and location, distribution system state estimation, power quality measurements and electrical distribution network topology processing. The development of the intelligent sensor platform was driven by the need for high-fidelity monitoring and control of medium voltage distribution feeder to enable higher penetration of renewable resources and microgrid operation.

14 SOLAR ENERGY↗

Impacts of Non-Ideal Back Contact on Capacitance Measurements in CdTe Solar Cells

CdTe solar cells suffer from a non-ideal back contact which can strongly affect the equivalent circuit model and complicate capacitance measurements. Here, five different back contact materials are deposited on identical CdTe absorbers and their influence on capacitance measurements is characterized. A five-element equivalent circuit model is shown to represent a CdTe solar cell with a non-ideal back contact, and capacitance-frequency (C-f) measurements on each sample clearly show the influence of this contact. Capacitance-voltage (C-V) measurements on each sample show the influence of frequency on measured capacitance. In the AlGaOx/Au sample, temperature dependent C-fs show the back barrier height to be 240 meV, and ongoing measurements will give a comparison of back barrier heights for all samples. This study provides insight into the efficacy of various back contacts and highlights potential errors in the interpretation of capacitance measurements due to the presence of the back contact.

14 SOLAR ENERGY↗