At least 289 records · Page 16

Time‐And‐Space Averaging Applied to Intermittent Multiphase Flow Experiments

Abstract Various researchers have studied fluctuations in pore‐scale phase occupancy during multiphase flow in porous media using synchrotron‐based X‐ray microcomputed tomography (micro‐CT). However, the impact of these fluctuations on the concept of a representative volume is not yet fully understood. In this study, we performed spatial and temporal averaging of multiphase flow experiments visualized with synchrotron‐based micro‐CT, focusing on oil saturation as the key parameter to determine a representative time‐and‐space average. Our findings revealed that a saturation value representative of both time and space was achieved during fractional flow experiments in drainage mode with fractional flows of 0.8, 0.5, and 0.3. Furthermore, we computed a range of relative permeabilities on the basis of whether momentaneous saturation or time‐and‐space averaged saturation was utilized for direct simulation. Our results highlighted the importance of time‐and‐space averaging in determining a representative relative permeability and indicated that the temporal and spatial scales covered in a typical micro‐CT flow experiment were sufficient to obtain a representative saturation value for sandstone rock under intermittent flow conditions.

Environmental Sciences & Ecology↗

SU-E-J-195: Quantification of Rotations and Deformations in Head and Heck Radiotherapy

Purpose: To quantify the magnitude of patient rotations and deformations over the course of head and neck radiotherapy. Methods: 45 CBCT images acquired weekly were selected retrospectively from 5 head and neck cancer patients. CBCT images were registered to the corresponding planning CT images using translation, rigid-body, and cubic B-spline deformable transformations. Elastix ( elastix.isi.uu.nl ), an open-source public domain registration algorithm, was used for all registrations with mutual information as similarity metric and gradient descent as optimization. Four-level multiresolution approach was employed with 2 cm B-spline grid spacing at the finest resolution. Registration qualities were visually verified. Rotational occurrences were quantified from the rigid-body registrations. The magnitude of deformations in planning target volumes (PTV) and organs were quantified from the deformation vector fields with rigid registrations as baseline. Results: The measured rotations (mean±std) were 1.0±1.0 deg, - 0.3±1.0 deg, and 0.1±0.8 deg in the sagittal, coronal, and axial plains respectively. The estimated magnitudes of deformations (mean±std) were 3.4±2.1 mm for PTVs, 2.9±1.2 mm for parotid glands, 2.8±1.2 mm for mandible, and 2.2±1.1 mm for spinal cord. The overall deformation in the body contour was 4.3±4.3 mm. The organ spatial deviation due to rotation was small and approximately 8.4% of that from deformations. Results varied among patients. Conclusion: Rotations occurred about 1.0 deg (1SD) in the H'N area. Daily geometric deviation of target volumes was considerable and mainly from tissue deformation than rotations. Proper safety margin is necessary for adequate target coverage. Online plan adaptation may mitigate the daily differences between the plan and actual patient poses. Partially supported by a grant from Varian Medical Systems, Palo Alto, CA.

60 APPLIED LIFE SCIENCES↗

Optical Imaging Methods for Volumetric Additive Manufacturing

Tomographic volumetric additive manufacturing (VAM) is a technique that enables light-induced curing of photoresins into complex 3D end use objects within a single step. This is made possible through projecting tomographically patterned light energy into a photo-curable resin volume within a rotating container. In order to monitor, quantify, and control curing during tomographic VAM, researchers need to visualize the curing parts in real-time. This may enable advancements toward dynamic, controlled and closedloop VAM methods in the future, as some researchers have shown. Herein we briefly review various optical imaging methods used to monitor printing in real-time, as well as provide some perspectives for future needs and considerations for imaging methods in VAM.

36 MATERIALS SCIENCE↗

Making Advanced Scientific Algorithms and Big Scientific Data Management More Accessible

Synchrotrons such as the Advanced Light Source (ALS) at Lawrence Berkeley National Laboratory are known as user facilities. They are sources of extremely bright X-ray beams, and scientists come from all over the world to perform experiments that require these beams. As the complexity of experiments has increased, and the size and rates of data sets has exploded, managing, analyzing and presenting the data collected at synchrotrons has been an increasing challenge. The ALS has partnered with high performance computing, fast networking, and applied mathematics groups to create a"super-facility", giving users simultaneous access to the experimental, computational, and algorithmic resources to overcome this challenge. This combination forms an efficient closed loop, where data despite its high rate and volume is transferred and processed, in many cases immediately and automatically, on appropriate compute resources, and results are extracted, visualized, and presented to users or to the experimental control system, both to provide immediate insight and to guide decisions about subsequent experiments during beam-time. In this paper, We will present work done on advanced tomographic reconstruction algorithms to support users of the 3D micron-scale imaging instrument (Beamline 8.3.2, hard X-ray micro-tomography).

97 MATHEMATICS AND COMPUTING↗

Investigation of Three-Dimensional Microstructure of Tricalcium Silicate (C 3 S) by Electron Microscopy

A serial block-face scanning electron microscopy (SBFSEM) system, composed of a scanning electron microscope (SEM) and an ultra-microtome installed within the SEM vacuum chamber, has been used to characterize the three-dimensional (3D) microstructure of tricalcium silicate (C 3 S) grains embedded in epoxy resin. A selection of C 3 S grains were segmented and rendered with 3D-image processing software, which allowed the C 3 S grains to be clearly visualized and enabled statistically quantitative analysis. The results show that about 5% of the C 3 S grains have volumes larger than 1 μm 3 and the average volume of the grains is 25 μm 3 . Pores can also be clearly seen in the biggest C 3 S grain, the volume of which is 3.6 × 10 4 μm 3 , and the mean volume and total volume of all the pores within this grain are 4.8 μm 3 and 3.0 × 10 3 μm 3 , respectively. This work provides a new approach for the characterization of the 3D spatial structure of raw C 3 S materials, and the resulting 3D structure of the raw C 3 S is important for further systematic research on the relationships between the spatial microstructure and the hydration kinetics of C 3 S and other cement minerals.

36 MATERIALS SCIENCE↗

Local Tumor Control, Visual Acuity, and Survival After Hypofractionated Stereotactic Photon Radiotherapy of Choroidal Melanoma in 212 Patients Treated Between 1997 and 2007

Purpose: To evaluate long-term local tumor control, visual acuity, and survival after hypofractionated linear accelerator-based stereotactic photon radiotherapy in patients with choroidal melanoma. Methods and Materials: Between 1997 and 2007, 212 patients with choroidal melanoma unsuitable for ruthenium-106 brachytherapy or local resection were treated stereotactically at a linear accelerator with 6-MV photon beams at the Medical University of Vienna in five fractions over 7 days. Twenty-four patients received a total dose of 70 Gy (five fractions of 14 Gy), 158 a total dose of 60 Gy (five fractions of 12 Gy) and 30 patients a total dose of 50 Gy (five fractions of 10 Gy) applied on the 80% isodose. Ophthalmologic examinations were performed at baseline and every 3 months in the first 2 years, every 6 months until 5 years, and once a year thereafter until 10 years after radiotherapy. Assessment of visual acuity, routine ophthalmologic examinations, and measurement of tumor base dimension and height using standardized A-scan and B-scan echography were done at each visit. Funduscopy and fluorescein angiography were done when necessary to document tumor response. Results: Median tumor height and volume decreased from 4.8 mm and 270.7 mm{sup 3} at baseline to 2.6 mm and 86.6 mm{sup 3} at the last individual follow-up, respectively (p < 0.001, p < 0.001). Median visual acuity decreased from 0.55 at baseline to hand motion at the last individual follow-up (p < 0.001). Local tumor control was 95.9% after 5 years and 92.6% after 10 years. Thirty-two patients developed metastatic disease, and 22 of these patients died during the follow-up period. Conclusion: Hypofractionated stereotactic photon radiotherapy with 70 to 50 Gy delivered in five fractions in 7 days is sufficient to achieve excellent local tumor control in patients with malignant melanoma of the choroid. Disease outcome and vision are comparable to those achieved with proton beam radiotherapy. Decreasing the total dose below 60 Gy seems to be possible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-T-490: Separating Effects Influencing Detector Response in Small MV Photon Fields

Purpose: Different detector properties influence their responses especially in field sizes below the lateral electron range. Due to the finite active volume, the detector density and electron perturbation at other structural parts, the response factor is in general field size dependent. We aimed to visualize and separate the main effects contributing to detector behavior for a variety of detector types. This was achieved in an experimental setup, shielding the field center. Thus, effects caused by scattered radiation could be examined separately. Methods: Signal ratios for field sizes down to 8 mm (SSD 90 cm, water depth 10 cm) of a 6MV beam from a Siemens Primus LINAC were recorded with several detectors: PTW microDiamond and PinPoint ionization chamber, shielded diodes (PTW P-60008, IBA PFD and SNC Edge) and unshielded diodes (PTW E-60012 and IBA SFD). Measurements were carried out in open fields and with an aluminum pole of 4 mm diameter as a central block. The geometric volume effect was calculated from profiles obtained with Gafchromic EBT3 film, evaluated using FilmQA Pro software (Ashland, USA). Results: Volume corrections were 1.7% at maximum. After correction, in small open fields, unshielded diodes showed a lower response than the diamond, i.e. diamond detector over-response seems to be higher than that for unshielded diodes. Beneath the block, this behavior was amplified by a factor of 2. For the shielded diodes, the overresponse for small open fields could be confirmed. However their lateral response behavior was strongly type dependent, e.g. the signal ratio dropped from 1.02 to 0.98 for the P-60008 diode. Conclusion: The lateral detector response was experimentally examined. Detector volume and density alone do not fully account for the field size dependence of detector response. Detector construction details play a major role, especially for shielded diodes.

61 RADIATION PROTECTION AND DOSIMETRY↗

Comparative accuracy of qualitative and quantitative 18F-FDG PET/CT analysis in detection of lymph node metastasis from anal cancer

Purpose: To compare the diagnostic performance of qualitative and quantitative 18F-FDG PET/CT in detection of regional and distant lymph node metastasis in patients with anal cancer. Methods: Between 2004 and 2017, 28 patients with anal cancer who had staging PET/CT and pathological assessment of suspicious lymph nodes were included. For qualitative analysis, positive lymph nodes were defined as uptake visually higher than the liver reference uptake. For quantitative study, lymph nodes were contoured to determine maximum standard uptake value (SUV{sub max}) and metabolic tumor volume (MTV). Receiver operating characteristic (ROC) curves were plotted to extract the optimal cut-offs and area under the curve (AUC) of SUV{sub max}, lesion to background (L/B) ratio, short axis diameter (SAD), and MTV of lymph nodes. Histopathologic analysis was a reference standard. Results: A total of 28 lymph nodes (24 inguinal, 2 external iliac, 1 internal iliac, and 1 paraaortic nodes) in 28 patients on PET/CT were included. With the qualitative visual analysis, 19 patients were categorized as positive for nodal metastasis with sensitivity, specificity, and accuracy of 85%, 75%, and 82%. The optimal SUV{sub max} and L/B ratio cut-offs were 2.6 and 1.0 with both sensitivity and specificity of 95% and 75% (AUC of SUV{sub max} = 0.893, AUC of L/B ratio = 0.912). Using the best cut-off of 1.6 cm for SAD and 3.65 cm{sup 3} for MTV, both sensitivity and specificity were 80% and 100% (AUC of SAD = 0.950, AUC of MTV = 0.931). Conclusions: SUV{sub max} optimization may be helpful in enhancing the diagnostic accuracy of 18F-FDG PET/CT in nodal staging patients with anal cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Integrating 3D seismic curvature and curvature gradient attributes for fracture characterization: Methodologies and interpretational implications

In 3D seismic interpretation, curvature is a popular attribute that depicts the geometry of seismic reflectors and has been widely used to detect faults in the subsurface; however, it provides only part of the solutions to subsurface structure analysis. This study extends the curvature algorithm to a new curvature gradient algorithm, and integrates both algorithms for fracture detection using a 3D seismic test data set over Teapot Dome (Wyoming). In fractured reservoirs at Teapot Dome known to be formed by tectonic folding and faulting, curvature helps define the crestal portion of the reservoirs that is associated with strong seismic amplitude and high oil productivity. In contrast, curvature gradient helps better define the regional northwest-trending and the cross-regional northeast-trending lineaments that are associated with weak seismic amplitude and low oil productivity. In concert with previous reports from image logs, cores, and outcrops, the current study based on an integrated seismic curvature and curvature gradient analysis suggests that curvature might help define areas of enhanced potential to form tensile fractures, whereas curvature gradient might help define zones of enhanced potential to develop shear fractures. In certain fractured reservoirs such as at Teapot Dome where faulting and fault-related folding contribute dominantly to the formation and evolution of fractures, curvature and curvature gradient attributes can be potentially applied to differentiate fracture mode, to predict fracture intensity and orientation, to detect fracture volume and connectivity, and to model fracture networks.

3D, attributes, fractures, visualization↗

Root system architecture and environmental flux analysis in mature crops using 3D root mesocosms

Current methods of root sampling typically only obtain small or incomplete sections of root systems and do not capture their true complexity. To facilitate the visualization and analysis of full-sized plant root systems in 3-dimensions, we developed customized mesocosm growth containers. While highly scalable, the design presented here uses an internal volume of 45 ft 3 (1.27 m 3 ), suitable for large crop and bioenergy grass root systems to grow largely unconstrained. Furthermore, they allow for the excavation and preservation of 3-dimensional root system architecture (RSA), and facilitate the collection of time-resolved subterranean environmental data. Sensor arrays monitoring matric potential, temperature and CO 2 levels are buried in a grid formation at various depths to assess environmental fluxes at regular intervals. Methods of 3D data visualization of fluxes were developed to allow for comparison with root system architectural traits. Following harvest, the recovered root system can be digitally reconstructed in 3D through photogrammetry, which is an inexpensive method requiring only an appropriate studio space and a digital camera. We developed a pipeline to extract features from the 3D point clouds, or from derived skeletons that include point cloud voxel number as a proxy for biomass, total root system length, volume, depth, convex hull volume and solidity as a function of depth. Ground-truthing these features with biomass measurements from manually dissected root systems showed a high correlation. We evaluated switchgrass, maize, and sorghum root systems to highlight the capability for species wide comparisons. We focused on two switchgrass ecotypes, upland (VS16) and lowland (WBC3), in identical environments to demonstrate widely different root system architectures that may be indicative of core differences in their rhizoeconomic foraging strategies. Finally, we imposed a strong physiological water stress and manipulated the growth medium to demonstrate whole root system plasticity in response to environmental stimuli. Hence, these new “3D Root Mesocosms” and accompanying computational analysis provides a new paradigm for study of mature crop systems and the environmental fluxes that shape them.

59 BASIC BIOLOGICAL SCIENCES↗

Extensible Computational Chemistry Environment

ECCE provides a sophisticated graphical user interface, scientific visualization tools, and the underlying data management framework enabling scientists to efficiently set up calculations and store, retrieve, and analyze the rapidly growing volumes of data produced by computational chemistry studies. ECCE was conceived as part of the Environmental Molecular Sciences Laboratory construction to solve the problem of researchers being able to effectively utilize complex computational chemistry codes and massively parallel high performance compute resources. Bringing the power of these codes and resources to the desktops of researcher and thus enabling world class research without users needing a detailed understanding of the inner workings of either the theoretical codes or the supercomputers needed to run them was a grand challenge problem in the original version of the EMSL. ECCE allows collaboration among researchers using a web-based data repository where the inputs and results for all calculations done within ECCE are organized. ECCE is a first of kind end-to-end problem solving environment for all phases of computational chemistry research: setting up calculations with sophisticated GUI and direct manipulation visualization tools, submitting and monitoring calculations on remote high performance supercomputers without having to be familiar with the details of using these compute resources, and performing results visualization and analysis including creating publication quality images. ECCE is a suite of tightly integrated applications that are employed as the user moves through the modeling process.

Source record↗

Extensible Computational Chemistry Environment

ECCE provides a sophisticated graphical user interface, scientific visualization tools, and the underlying data management framework enabling scientists to efficiently set up calculations and store, retrieve, and analyze the rapidly growing volumes of data produced by computational chemistry studies. ECCE was conceived as part of the Environmental Molecular Sciences Laboratory construction to solve the problem of researchers being able to effectively utilize complex computational chemistry codes and massively parallel high performance compute resources. Bringing the power of these codes and resources to the desktops of researcher and thus enabling world class research without users needing a detailed understanding of the inner workings of either the theoretical codes or the supercomputers needed to run them was a grand challenge problem in the original version of the EMSL. ECCE allows collaboration among researchers using a web-based data repository where the inputs and results for all calculations done within ECCE are organized. ECCE is a first of kind end-to-end problem solving environment for all phases of computational chemistry research: setting up calculations with sophisticated GUI and direct manipulation visualization tools, submitting and monitoring calculations on remote high performance supercomputers without having to be familiar with the details of using these compute resources, and performing results visualization and analysis including creating publication quality images. ECCE is a suite of tightly integrated applications that are employed as the user moves through the modeling process.

Source record↗

3D MRI in Musculoskeletal Imaging: Current and Future Applications

Purpose of Review: This article addresses current clinical applications, recent literature, and potential future applications of 3-dimensional magnetic resonance imaging (3D MRI) for musculoskeletal (MSK) applications. Recent Findings: The main advantage of 3D MRI over standard 2-dimensional MRI is its ability to reduce partial volume averaging artifacts and create multiplanar reconstruction (MPRs) in any plane with any slice thickness from a single high-resolution isotropic acquisition. 3D MRI acquisitions are particularly useful for the evaluation of articular cartilage, which is prone to volume averaging artifacts, and for the assessment of longitudinally coursing structures such as peripheral nerves and tendons, which are better visualized with non-orthogonal MPRs. 3D MRI is also useful for surface and volumetric analysis of bone and cartilage for preoperative and longitudinal assessments. Current research is focused on decreasing acquisition times and automating segmentation through machine learning, thus overcoming some of the current limitations of 3D MRI and providing new applications for this technique. Summary: 3D MRI is widely used in MSK imaging today, and its use is likely to continue to increase in the future, with recent advancements focused on accelerated acquisition techniques and quantitative imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Anatomically Validated Brachial Plexus Contouring Method for Intensity Modulated Radiation Therapy Planning

Purpose: To develop contouring guidelines for the brachial plexus (BP) using anatomically validated cadaver datasets. Magnetic resonance imaging (MRI) and computed tomography (CT) were used to obtain detailed visualizations of the BP region, with the goal of achieving maximal inclusion of the actual BP in a small contoured volume while also accommodating for anatomic variations. Methods and Materials: CT and MRI were obtained for 8 cadavers positioned for intensity modulated radiation therapy. 3-dimensional reconstructions of soft tissue (from MRI) and bone (from CT) were combined to create 8 separate enhanced CT project files. Dissection of the corresponding cadavers anatomically validated the reconstructions created. Seven enhanced CT project files were then automatically fitted, separately in different regions, to obtain a single dataset of superimposed BP regions that incorporated anatomic variations. From this dataset, improved BP contouring guidelines were developed. These guidelines were then applied to the 7 original CT project files and also to 1 additional file, left out from the superimposing procedure. The percentage of BP inclusion was compared with the published guidelines. Results: The anatomic validation procedure showed a high level of conformity for the BP regions examined between the 3-dimensional reconstructions generated and the dissected counterparts. Accurate and detailed BP contouring guidelines were developed, which provided corresponding guidance for each level in a clinical dataset. An average margin of 4.7 mm around the anatomically validated BP contour is sufficient to accommodate for anatomic variations. Using the new guidelines, 100% inclusion of the BP was achieved, compared with a mean inclusion of 37.75% when published guidelines were applied. Conclusion: Improved guidelines for BP delineation were developed using combined MRI and CT imaging with validation by anatomic dissection.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Volume Labeling with Alexa-Fluor Dyes and Surface Functionalization of Highly Sensitive Fluorescent SiO2 Nanoparticles

A new synthesis approach is described that allows the direct incorporation of fluorescent labels into the volume or body of SiO2 nanoparticles. In this process, fluorescent Alexa Fluor dyes with different emission wavelengths were covalently incorporated into the SiO2 nanoparticles during their formation by the hydrolysis of tetraethoxysilane. The dye molecules were homogeneously distributed throughout the SiO2 nanoparticles. The quantum yields of the Alexa Fluor volume-labeled SiO2 nanoparticles were much higher than nanoparticles labeled using conventional organic dyes. The size of the resulting nanoparticles was controlled using microemulsion reaction media with sizes in the range of 20-100 nm and a polydispersity of <15%. In comparison with conventional surface tagged particles created by post-synthesis modification, this process maintains the physical and surface chemical properties that have the most pronounced effect on colloidal stability and interactions with their surroundings. These volume-labeled nanoparticles have proven to be extremely robust, showing excellent signal strength, negligible photobleaching, and minimal loss of functional organic components. The native or free surface of the volume-labeled particles can be altered to achieve a specific surface functionality without altering fluorescence. Their utility was demonstrated for visualizing the association of surface modified fluorescent particles with cultured macrophages. Differences in particle agglomeration and cell association were clearly associated with differences in observed nanoparticle toxicity. The capacity to maintain particle fluorescence while making significant changes to surface chemistry makes these particles extremely versatile and useful for studies of particle agglomeration, uptake, and transport in environmental and biological systems.

Wang, Wei↗

A Comparison of the Perceptual Benefits of Linear Perspective and Physically-Based Illumination for Display of Dense 3D Streamtubes

Large datasets typically contain coarse features comprised of finer sub-features. Even if the shapes of the small structures are evident in a 3D display, the aggregate shapes they suggest may not be easily inferred. From previous studies in shape perception, the evidence has not been clear whether physically-based illumination confers any advantage over local illumination for understanding scenes that arise in visualization of large data sets that contain features at two distinct scales. In this paper we show that physically-based illumination can improve the perception for some static scenes of complex 3D geometry from flow fields. We perform human-subjects experiments to quantify the effect of physically-based illumination on participant performance for two tasks: selecting the closer of two streamtubes from a field of tubes, and identifying the shape of the domain of a flow field over different densities of tubes. We find that physically-based illumination influences participant performance as strongly as perspective projection, suggesting that physically-based illumination is indeed a strong cue to the layout of complex scenes. We also find that increasing the density of tubes for the shape identification task improved participant performance under physically-based illumination but not under the traditional hardware-accelerated illumination model.

3D shape perception↗

Oxidation performance and limitations of additively manufactured SiC/Si-O-C composites at elevated temperatures

Here, SiC preforms were infiltrated with polycarbosiloxane preceramic polymer to create low-cost SiC—Si x O y C z matrix composites for possible high temperature application. The effect of specimen annealing conditions on the steam and air oxidation resistance was analyzed. Air exposures from 900–1500°C showed stability of the Si x O y C z matrix phase with moderate oxidation resistance. After 900°C exposures, oxidation of the composite is primarily limited to the matrix phase, and only at 1200 and 1500°C was SiC consumption visualized. Steam cycle exposures at 1200°C resulted in rapid linear oxidation of the composites with induced specimen swelling from volume expansion associated with internal oxidation. Specimens annealed in argon were found to be the most oxidation resistant due to increased matrix crystallinity and carbon retention. The results of this work were used to develop clear strategies for improving the high-temperature properties of SiC—Si x O y C z composites.

36 MATERIALS SCIENCE↗

Managing negative values is reservoir inflow computation: A case study

Reservoir inflow is conventionally estimated using the water balance method, which involves the reservoir release and the change in storage during the period considered. As a result, the estimated inflow may sometimes be negative as the errors involved in each input variable build-up to the output. In our study, the fleet data was provided by the Tennessee Valley Authority (TVA) for their Norris Hydropower facility. Unlike the flow release data, which was readily accessible, the change in storage had to be calculated using the reservoir elevation and volume relationship. The original inflow estimates produced a wide range of negative values with large outliers, making it difficult to visualize the current trends. This paper describes a methodology to remove the negative values encountered during the inflow computation, and the results were analyzed by correlating with the nearby streamflow gaging stations.

Shibu, Asha↗