Search NASA⌕ Search

SEARCH · Search NASA

Results for “wire”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Use of beam deflection to control an electron beam wire deposition process

A method for controlling an electron beam process wherein a wire is melted and deposited on a substrate as a molten pool comprises generating the electron beam with a complex raster pattern, and directing the beam onto an outer surface of the wire to thereby control a location of the wire with respect to the molten pool. Directing the beam selectively heats the outer surface of the wire and maintains the position of the wire with respect to the molten pool. An apparatus for controlling an electron beam process includes a beam gun adapted for generating the electron beam, and a controller adapted for providing the electron beam with a complex raster pattern and for directing the electron beam onto an outer surface of the wire to control a location of the wire with respect to the molten pool.

Taminger, Karen M.↗

Next Generation Wiring

Wiring is a major operational component on aerospace hardware that accounts for substantial weight and volumetric space. Over time wire insulation can age and fail, often leading to catastrophic events such as system failure or fire. The next generation of wiring must be reliable and sustainable over long periods of time. These features will be achieved by the development of a wire insulation capable of autonomous self-healing that mitigates failure before it reaches a catastrophic level. In order to develop a self-healing insulation material, three steps must occur. First, methods of bonding similar materials must be developed that are capable of being initiated autonomously. This process will lead to the development of a manual repair system for polyimide wire insulation. Second, ways to initiate these bonding methods that lead to materials that are similar to the primary insulation must be developed. Finally, steps one and two must be integrated to produce a material that has no residues from the process that degrades the insulating properties of the final repaired insulation. The self-healing technology, teamed with the ability to identify and locate damage, will greatly improve reliability and safety of electrical wiring of critical systems. This paper will address these topics, discuss the results of preliminary testing, and remaining development issues related to self-healing wire insulation.

Medelius, Petro↗

LANSCE wire scanning diagnostics device mechanical design

The Los Alamos Neutron Science Center (LANSCE) is one of the major experimental science facilities at the Los Alamos National Laboratory (LANL). The core of LANSCE's work lies in the operation of a powerful linear accelerator, which accelerates protons up to 84% the speed oflight. These protons are used for a variety of purposes, including materials testing, weapons research and isotopes production. To assist in guiding the proton beam, a series of over one hundred wire scanners are used to measure the beam profile at various locations along the half-mile length of the particle accelerator. A wire scanner is an electro-mechanical device that moves a set of wires through a particle beam and measures the secondary emissions from the resulting beam-wire interaction to obtain beam intensity information. When supplemented with data from a position sensor, this information is used to determine the cross-sectional profile of the beam. This measurement allows beam operators to adjust parameters such as acceleration, beam steering, and focus to ensure that the beam reaches its destination as effectively as possible. Some of the current wire scanners are nearly forty years old and are becoming obsolete. The problem with current wire scanners comes in the difficulty of maintenance and reliability. The designs of these wire scanners vary making it difficult to keep spare parts that would work on all designs. Also many of the components are custom built or out-dated technology and are no longer in production.

43 PARTICLE ACCELERATORS↗

LANSCE-R WIRE-SCANNER ANALOG FRONT-END ELECTRONICS

A new AFE is being developed for the new LANSCE-R wire-scanner systems. The new AFE is implemented in a National Instruments Compact RIO (cRIO) module installed a BiRa 4U BiRIO cRIO chassis specifically designed to accommodate the cRIO crate and all the wire-scanner interface, control and motor-drive electronics. A single AFE module provides interface to both X and Y wire sensors using true DC coupled transimpedance amplifiers providing collection of the wire charge signals, real-time wire integrity verification using the normal dataacquisition system, and wire bias of 0V to +/-50V. The AFE system is designed to accommodate comparatively long macropulses (>1ms) with high PRF (>120Hz) without the need to provide timing signals. The basic AFE bandwidth is flat from true DC to 50kHz with a true first-order pole at 50kHz. Numeric integration in the cRIO FPGA provides real-time pulse-to-pulse numeric integration of the AFE signal to compute the total charge collected in each macropulse. This method of charge collection eliminates the need to provide synchronization signals to the wire-scanner AFE while providing the capability to accurately record the charge from long macropulses at high PRF.

Accelerator Design, Technology, and Operations↗

Beam Position and Phase Monitor - Wire Mapping System

The Los Alamos Neutron Science Center (LANSCE) deploys many cylindrical beam position and phase monitors (BPPM) throughout the linac to measure the beam central position, phase and bunched-beam current. Each monitor is calibrated and qualified prior to installation to insure it meets LANSCE requirements. The BPPM wire mapping system is used to map the BPPM electrode offset, sensitivity and higher order coefficients. This system uses a three-axis motion table to position the wire antenna structure within the cavity, simulating the beam excitation of a BPPM at a fundamental frequency of 201.25 MHz. RF signal strength is measured and recorded for the four electrodes as the antenna position is updated. An effort is underway to extend the systems service to the LANSCE facility by replacing obsolete electronic hardware and taking advantage of software enhancements. This paper describes the upgraded wire positioning system's new hardware and software capabilities including its revised antenna structure, motion control interface, RF measurement equipment and Labview software upgrades. The main purpose of the wire mapping system at LANSCE is to characterize the amplitude response versus beam central position of BPPMs before they are installed in the beam line. The wire mapping system is able to simulate a beam using a thin wire and measure the signal response as the wire position is varied within the BPPM aperture.

43 PARTICLE ACCELERATORS↗

Heat transfer enhancement in a tube with equilateral triangle cross sectioned coiled wire inserts

The heat transfer and pressure drop were experimentally investigated in a coiled wire inserted tube in turbulent flow regime. The coiled wire has equilateral triangular cross section and was inserted separately from the tube wall. The experiments were carried out with three different pitch ratios (P/D = 1, 2 and 3) and two different ratio of equilateral triangle length side to tube diameter (a/D = 0.0714 and 0.0892) at a distance (s) of 1 mm from the tube wall in the range of Reynolds number from 3500 to 27,000. Uniform heat flux was applied to the external surface of the tube and air was selected as fluid. The experimental results obtained from a smooth tube were compared with those from the studies in literature for validation of experimental set-up. The use of coiled wire inserts leads to a considerable increase in heat transfer and pressure drop over the smooth tube. The Nusselt number rises with the increase of Reynolds number and wire thickness and the decrease of pitch ratio. The highest overall enhancement efficiency of 36.5% is achieved for the wire with a/D = 0.0892 and P/D = 1 at Reynolds number of 3858. Consequently, the experimental results reveal that the best operating regime of all coiled wire inserts is detected at low Reynolds number, leading to more compact heat exchanger. (author)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Copper Nanoparticle Synthesis By The Wire Explosion Technique

Wire explosion technique is performed by passing a high power pulsed current through a metallic wire to disintegrate it through Joule heating effect. In this work, the production of nanoparticles by the wire explosion technique has been investigated. Copper wires with a diameter of 125 mum and a length of 3.5 cm are exploded in air at two different pressures, namely, 1 bar and 10{sup -2} mbar. Particles produced from the wire explosion are collected for characterization. The characterization of the particles is done by using field emission scanning electron microscope (FE-SEM) and energy dispersive analysis by X-rays (EDAX). The morphology and chemical composition of the particles produced at the two different pressures are compared. Discharge current and optical emission spectra of the wire explosion at the two pressures are also presented.

36 MATERIALS SCIENCE↗

Fabrication and Test of C3a: A Six-Layer Subscale Canted $\cos \theta$ Dipole Magnet Using High-Temperature Superconducting corc Wires

REBCO coated conductors have a strong potential for high-field magnet applications. The REBCO technology, however, is still in its infancy for accelerator magnet applications. As part of the U.S. Magnet Development Program (MDP), we developed a six-layer canted cos θ dipole magnet, C3a, using CORC® wires developed by Advanced Conductor Technologies LLC. All the layers were wound using a semi-automated winding machine. Three layers of the magnet used CORC® wires containing the SuperPower “AP” REBCO tapes and the remaining layers used the wires containing the “HM” tapes. At 77 K, both kinds of CORC® wires showed 5% to 10% degradation, after bending to a minimum bend radius of 30 or 35 mm, with respect to the self-field critical current measured before winding. At 4.2 K, the magnet reached 9.5 kA at a ramp rate of 9 A s -1 and generated a dipole field of 1.4 T. Further, the critical current of one layer degraded by 4% after a current transient up to 10.5 kA ramped in an averaged rate of 175 kA s -1 or 20 T s -1 . We confirmed the HM CORC® wire can carry a higher current than the AP CORC® wire at 4.2 K. The test results of the C3a magnet showed that the fabrication and assembly procedure can be used for the upcoming full-scale C3 magnet.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Wire-Based Additive Manufacturing of Stainless Steel Components

In this work three different wire-fed additive manufacturing (AM) processes were employed to evaluate differences between laser, arc, and electron beam heat sources used for high-deposition-rate AM on the order of 1 kg/h. Optimum weld and build parameters were developed independently to match the characteristics of each heat source using 308L stainless steel welding wire as the feedstock. Laser-wire AM was made with the lowest energy per unit length of weld and had the best control of the melt pool and surface finish. Wire arc-based AM had an intermediate energy per unit length of weld of approximately 5× that of the laser process, while electron beam wire AM had the highest energy per unit length of weld at approximately 10× that of the laser process. Analysis of the parts that were built included evaluation of mechanical properties and microstructures, and these properties are discussed with respect to the difference in input energy and cooling rates. Results show that all three processes build parts with properties that exceed those of annealed 304L wrought stainless steel. However, significant differences exist between the processes, and the results presented here can be used to help select the best wire-fed process for a given high-deposition-rate application.

36 MATERIALS SCIENCE↗

Simultaneous Multiple Preoperative Localizations of Small Pulmonary Lesions Using a Short Hook Wire and Suture System

PurposeThe aim of the study was to retrospectively evaluate simultaneous multiple hook wire placement outcomes before video-assisted thoracoscopic surgery (VATS).Materials and MethodsThirty-eight procedures were performed on 35 patients (13 men and 22 women; mean age, 59.9 years) with 80 lung lesions (mean diameter 7.9 mm) who underwent simultaneous multiple hook wire placements for preoperative localizations. The primary endpoints were technical success, complications, procedure duration, and VATS outcome; secondary endpoints included comparisons between technical success rates, complication rates, and procedure durations of the 238 single-placement procedures performed. Complications were also evaluated.ResultsIn 35 procedures including 74 lesions, multiple hook wire placements were technically successful; in the remaining three procedures, the second target placement was aborted because of massive pneumothorax after the first placement. Although complications occurred in 34 procedures, no grade 3 or above adverse event was observed. The mean procedure duration was 36.4 ± 11.8 min. Three hook wires dislodged during patient transport to the surgical suite. Seventy-four successfully marked lesions were resected. Six lesions without hook wires were successfully resected after detection by palpation with an additional mini-thoracotomy or using subtle pleural changes as a guide. The complication rates and procedure durations of multiple-placement procedures were significantly higher (P = 0.04) and longer (P < 0.001) than those in the single-placement group, respectively, while the technical success rate was not significantly different (P = 0.051).ConclusionsSimultaneous multiple hook wire placements before VATS were clinically feasible, but increased the complication rate and lengthened the procedure time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Generation and characterization of nano tungsten oxide particles by wire explosion process

Nano tungsten oxide particles are produced by wire explosion process. It is realized that by exploding tungsten conductor in lower pressure of oxygen, unreacted phase of tungsten was present and it could be reduced by increasing the operating pressure and increasing the amount of energy deposited to the exploding conductor. It is realized that the nucleation rate of the particle could be high only at the point of maximum saturation ratio, irrespective of the pressure of the oxygen. The size of the critical nucleus formed is low when the saturation ratio and the nucleation rate are at maximum. The nano metal oxide particle formation by wire explosion process allows one to conclude that the second stage annealing process has a major impact on the final grain size formed. The high speed camera photographs of wire explosion process were used to understand the dynamics of particle formation by wire explosion process. The Transmission Electron Microscopy (TEM) analysis indicates that the nano tungsten oxide (WO{sub 3}) particles are of spherical shape and the analysis of particle size indicates that it follows log normal distribution. - Graphical Abstract: Nano tungsten oxide (WO{sub 3}) particles are produced by wire explosion process. Theoretical analysis indicates that the size of the critical nucleus formed is low when the saturation ratio and the nucleation rate are at maximum. High speed camera photographs of wire explosion process were used to understand the dynamics of particles formed. Research Highlights: {yields}Lower particle size is possible with lower pressure. {yields}Particle size is increased with reduced energy ratio. {yields}Unreacted tungsten content reduces when oxygen pressure increases.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Magnetic field-assisted synthesis of wire-like Co{sub 3}O{sub 4} nanostructures: Electrochemical and photocatalytic studies

Graphical abstract: Schematic illustration for the magnetic field-assisted growth of wire-like Co{sub 3}O{sub 4} nanostructure. Display Omitted Highlights: ► Co{sub 3}O{sub 4} nanowires are prepared by magnetic field hydrothermal reduction and annealing. ► These Co{sub 3}O{sub 4} nanowires possess enhanced capacitance. ► The Co{sub 3}O{sub 4} nanowires have a good photocatalytic activity for methyl orange. -- Abstract: Wire-like Co{sub 3}O{sub 4} nanostructures were prepared by the combination of magnetic field-assisted hydrothermal reduction of cobalt ions and the subsequent ambient annealing at 500 °C. X-ray diffraction (XRD) and scanning electron microscopy (SEM) were used to characterize the structure and morphological evolution of the products. The results show that the wire-like nanostructures possess diameters about 250 nm and lengths over 10 μm. The possible formation mechanism of the wire-like Co{sub 3}O{sub 4} nanostructures is also proposed based on the SEM results. Galvanostatic methods were used to characterize the electrochemical properties. The measurements indicate that the wire-like Co{sub 3}O{sub 4} nanostructures show larger discharge and charge capacities than that of spherical Co{sub 3}O{sub 4} nanoparticles prepared in the absence of magnetic field. In addition, the photocatalytic activity of the products was investigated by measuring the photodegradation of methyl orange solution under ultraviolet radiation, which shows that both the wire-like and spherical products have a good photocatalytic activity.

36 MATERIALS SCIENCE↗

Heterobinuclear Light Absorber Coupled to Molecular Wire for Charge Transport across Ultrathin Silica Membrane for Artificial Photosynthesis

Coupling of robust, all-inorganic heterobinuclear light absorbers to metal oxide catalysts for water oxidation across an ultrathin product-separating silica membrane requires charge transfer through organic molecular wires embedded in the silica. A synthetic approach for assembling the bimetallic units on the silica surface is introduced that is compatible with the presence of encapsulated organic molecules. Accurate selection and fine tuning of the concentration of embedded conducting wires are enabled by a two-step method consisting of surface attachment of a tripodal anchor, trimethoxysilyl aniline, followed by attachment of p-oligo(phenylene vinylene) through amide linkage. Each step of the assembly process was monitored and characterized by a combination of Fourier transform infrared, Fourier transform-Raman, and UV-vis spectroscopy techniques. Hole transfer was observed from transient Co III , formed by Ti IV OCo II → Ti III OCo III charge transfer excitation of the chromophore, to p-oligo(phenylene vinylene) molecule within the 8 ns width of the photolysis laser pulse by transient optical absorption spectroscopy of the wire radical cation. The rectifying property of the light absorber-wire assembly enabled by appropriate selection of redox potentials of metals and embedded wire obviates the need for a molecularly defined linkage between the components. Combined with the previously observed ultrafast hole injection from the embedded wires to Co oxide catalyst, the result implies visible-light-induced hole transfer from visible-light-excited binuclear light absorber to water oxidation catalyst across the silica separation membrane in a few nanoseconds or faster. Finally, demonstration and understanding of this interfacial charge-transfer step is critical for developing nanoscale core-shell architectures for complete photosynthetic cycles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spectroscopic research of underwater electrical wire explosion

Results of spectroscopic research in the visible range of light of the radiation generated by underwater electrical wire explosions (UEWE) are presented. A pulsed generator with an output voltage of {approx}110 kV, current of {approx}70 kA, and rise time of {approx}60 ns was used for electrical explosion of Cu wires 0.1 mm in diameter and 50 mm in length. It was shown that UEWE is not governed by the 'polarity' effect, which plays an important role in electrical wire explosions in vacuum. The results of detailed space- and time-resolved spectroscopic measurements show that the radiation spectrum differs significantly of the spectrum expected from the exploding wire. A model is suggested based on the formation of a few {mu}m 'water' plasma layer in the vicinity of the exploding wire plasma which efficiently absorbs the radiation of the exploding wire.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Azimuthally correlated ablation between z-pinch wire cores

Azimuthally correlated wire core ablation was compared for closely spaced versus widely spaced wires in a 1 MA Z-pinch. X-ray point-projection diagnostics revealed that 240 {mu}m spaced wires exhibited a correlation coefficient approaching unity in both real space and in k-space. This correlated ablation between wires at a fixed axial location is believed to occur due to an enhanced, localized Joule heating. Wires separated by 2.47 mm or greater were uncorrelated in real space, but correlated in k-space, indicating the ablation structure between wires was shifted in phase.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The role of magnetic field in the transition to streaming ablation in wire arrays

In wire array Z-pinches, the magnetic field configuration and the global field penetration of individual wires play a key role in the ablation plasma dynamics. Knowledge of the magnetic field configuration is necessary to understand the ablation plasma acceleration process near the wires. Two-dimensional resistive magnetohydrodynamics simulations show that a change in the global magnetic field configuration is critical to initiating inward flow of the ablation plasma. Analysis of these simulations show that the initially compressive JxB force around a wire in its vacuum field configuration undergoes a transition to a configuration in which the Lorentz force can accelerate plasma toward the array axis. This transition is achieved through a low magnetic Reynolds number diffusive flow in which the plasma and the magnetic field are decoupled. The plasma current follows the expanding plasma toward the array axis and, after traveling a critical distance scaling with the array radius divided by the wire number, the global magnetic field threads the wire core, thereby allowing JxB coronal acceleration into ablation streams.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

InAs quantum wire induced composition modulation in an In{sub 0.53}Ga{sub 0.37}Al{sub 0.10}As barrier layer grown on an InP substrate

Composition modulations are observed by transmission electron microscopy in In{sub 0.53}Ga{sub 0.37}Al{sub 0.10}As barrier layers that overgrow both single- and multilayer InAs quantum wire structures grown on an InP substrate. Indium-rich (gallium-deficient) regions were observed in the region of the barrier layer lying directly above individual quantum wires, while indium-deficient (gallium-rich) regions were detected in the barrier above the gaps between adjacent underlying quantum wires. The magnitude of such modulation was typically 7% (atomic percent) for both indium and gallium as estimated from the energy dispersive x-ray analysis. The origin of such composition modulations was determined by modeling the chemical potential distribution for indium and gallium on the growth front of the barrier layer at the initial capping stage of the quantum wires with finite element simulations. It is found that the number and positions of the indium-rich regions are determined by the combined effects of strain and surface energy distributions on the barrier material capping the quantum wires. Moreover the estimated magnitudes of the composition modulation for both indium and gallium from the finite element models are in good agreement with the experimental observations. This method provides a simple way to understand the origin of, and to estimate the magnitude of the quantum wire-induced composition modulation in the barrier layer.

36 MATERIALS SCIENCE↗

Dynamics of vapor emissions at wire explosion threshold

X-pinch plasmas have been actively studied in the recent years. Numerical simulation of the ramp-up of metallic vapor emissions from wire specimens shows that under impulsive Ohmic heating the wire core invariably reaches a supercritical state before explosion. The heating rate depends sensitively on the local wire resistance, leading to highly variable vapor emission flux along the wire. To examine the vapor emission process, we have visualized nickel wire explosions by means of shock formation in air. In a single explosion as captured by shadowgraphy, there usually appear several shocks with spherical or cylindrical wave front originating from different parts of the wire. Growth of various shock fronts in time is well characterized by a power-law scaling in one form or another. Continuum emission spectra are obtained and calibrated to measure temperature near the explosion threshold. Shock front structures and vapor plume temperature are examined.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗