Search NASA⌕ Search

SEARCH · Search NASA

Results for “AXIAL FLOW COMPRESSOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Performance of single-stage compressor designed on basis of constant total enthalpy with symmetrical velocity diagram at all radii and velocity ratio of 0.7 at rotor hub / Jack R. Burtt and Robert J. Jackson

A typical inlet axial-flow compressor inlet stage, which was designed on the basis of constant total enthalpy with symmetrical velocity diagram at all radii, was investigated. At a tip speed of 1126 feet per second, a peak pressure ratio of 1.28 was obtained at an efficiency of 0.76. At a tip speed, the highest practical flow was 28 pounds per second per square foot frontal area with an efficiency of 0.78. Data for a rotor relative inlet Mach number range of from 0.5 to 0.875 indicates that the critical value for any stage radial element is approximately 0.80 for the stage investigated.

FANS↗

Comparison of NACA 65-series compressor-blade pressure distributions and performance in a rotor and in cascade

An investigation has been conducted to compare the performance of NACA 65-series compressor blades in two-dimensional cascade with that in an axial flow compressor. Blade pressure distributions were obtained by the use of a mercury-seal pressure-transfer device. The comparison indicated that cascade data accurately predicted the turning angle and blade pressure distribution obtained in the compressor at design conditions.

CASCADES↗

Objectives and scope

This first chapter of a report on the aerodynamic design of axial-flow compressors presents the general objectives and scope of the over-all report. The basic problem of compressor design is outlined, and the approach generally taken to accomplish its solution is pointed out. The sixteen succeeding chapters in the report are summarized.

Systems design↗

Status of laser anemometry in turbomachinery research at the Lewis Research Center

Laser anemometer systems were developed for a full-annular turbine stator cascade facility and for a compressor rotor facility; both are ambient temperature axial flow facilities with a 20-inch tip diameter. The optical configurations of the two anemometers are similar single-component fringe-type backscatter systems with a probe volume diameter of 125 microns and length of about 2 mm. Laser anemometer measurements are compared with numerical solutions for a transonic axial flow compressor rotor and a turbine stator cascade.

Seasholtz, R. G.↗

Preliminary Results of Altitude-Wind-Tunnel Investigation of X24C-4B Turbojet Engine. IV - Performance of Modified Compressor: Performance of Modified Compressor - Part 4

The performance of the 11-stage axial-flow compressor, modified to improve the compressor-outlet velocity, in a revised X24C-4B turbojet engine is presented and compared with the performance of the compressor in the original engine. Performance data were obtained from an investigation of the revised engine in the MACA Cleveland altitude wind tunnel. Compressor performance data were obtained for engine operation with four exhaust nozzles of different outlet area at simulated altitudes from 15,OOO to 45,000 feet, simulated flight Mach numbers from 0.24 to 1.07, and engine speeds from 4000 to 12,500 rpm. The data cover a range of corrected engine speeds from 4100 to 13,500 rpm, which correspond to compressor Mach numbers from 0.30 to 1.00.

Thorman, H. Carl↗

Preliminary Results of Altitude-Wind-Tunnel Investigation of X34C-4B Turbojet Engine. III - Compressor Performance: Compressor Performance - 3

The performance of the 11-stage axial-flow compressor in the X24C-4B turbojet engine was analyzed on the basis of results obtained from an investigation of the complete engine in the NACA Cleveland altitude wind tunnel. The engine was operated with four, exhaust nozzles of different outlet area over a range of engine speeds from 6000 to 12,500 rpm, corrected engine speeds from approximately 6100 to 13,600 rpm, and compressor Mach numbers from 0.45 to 1.00. Data are presented for engine operation over a range of simulated altitudes from 15,000 to 45,000 feet and simulated flight Mach numbers from 0.24 to 1.08.

Dupree, David T.↗

Unsteady design-point flow phenomena in transonic compressors

High-frequency response probes which had previously been used exclusively in the MIT Blowndown Facility were successfully employed in two conventional steady state axial flow compressor facilities to investigate the unsteady flowfields of highly loaded transonic compressors at design point operation. Laser anemometry measurements taken simultaneously with the high response data were also analyzed. The time averaged high response data of static and total pressure agreed quite well with the conventional steady state instrumentation except for flow angle which showed a large spread in values at all radii regardless of the type of instrumentation used. In addition, the time resolved measurements confirmed earlier test results obtained in the MIT Blowdown Facility for the same compressor. The results of these tests have further revealed that the flowfields of highly loaded transonic compressors are heavily influenced by unsteady flow phenomena. The high response measurements exhibited large variations in the blade to blade flow and in the blade passage flow. The observed unsteadiness in the blade wakes is explained in terms of the rotor blades' shed vorticity in periodic vortex streets. The wakes were modeled as two-dimensional vortex streets with finite size cores. The model fit the data quite well as it was able to reproduce the average wake shape and bi-modal probability density distributions seen in the laser anemometry data. The presence of vortex streets in the blade wakes also explains the large blade to blade fluctuations seen by the high response probes which is simply due to the intermittent sampling of the vortex street as it is swept past a stationary probe.

Gertz, J. B.↗

Effects of diffusion factor, aspect ratio and solidity on overall performance of 14 compressor middle stages

A series of high hub tip radius ratio compressor stages representative of the middle and latter stages of axial flow compressors is discussed. The effects of aspect ratio, diffusion factor, and solidity on rotor and stage performance are determined. Fourteen middle stages are tested to study the effects on performance of varying both diffusion through the rotor and stator blades and blade aspect ratio. The design parameters in the streamline analysis program, the blade geometry program, and the blade coordinate program are presented.

Britsch, W. R.↗

8- by 6-Foot Supersonic Wind Tunnel Compressor Inspected

The NASA Glenn Research Center's 8- by 6-Foot Supersonic Wind Tunnel (8 6 SWT) is NASA's only transonic propulsion wind tunnel. The test section speed range is between Mach 0.25 and 2.0. The 9- by 15-Foot Low-Speed Wind Tunnel (9 15 LWST), which has a speed range from 0 to 175 mph, is housed in the return leg of the 8 6 SWT and uses the same compressor. The 8 6 SWT uses a large, seven-stage axial flow compressor to drive the air through the tunnel. The compressor is 17 ft in diameter and is rated at 1600 m3 (56,600 ft3) of air/sec. It is driven by three electric motors with a combined horsepower of 87,000. A close examination of this compressor was performed in 2001, the first time since February of 1966.

Krupar, Martin J.↗

Single-stage experimental evaluation of tandem-airfoil rotor and stator blading for compressors, part 8

An experimental investigation was conducted with an 0.8 hub/tip ratio, single-stage, axial flow compressor to determine the potential of tandem-airfoil blading for improving the efficiency and stable operating range of compressor stages. The investigation included testing of a baseline stage with single-airfoil blading and two tandem-blade stages. The overall performance of the baseline stage and the tandem-blade stage with a 20-80% loading split was considerably below the design prediction. The other tandem-blade stage, which had a rotor with a 50-50% loading split, came within 4.5% of the design pressure rise (delta P(bar)/P(bar) sub 1) and matched the design stage efficiency. The baseline stage with single-airfoil blading, which was designed to account for the actual rotor inlet velocity profile and the effects of axial velocity ratio and secondary flow, achieved the design predicted performance. The corresponding tandem-blade stage (50-50% loading split in both blade rows) slightly exceeded the design pressure rise but was 1.5 percentage points low in efficiency. The tandem rotors tested during both phases demonstrated higher pressure rise and efficiency than the corresponding single-airfoil rotor, with identical inlet and exit airfoil angles.

Brent, J. A.↗

Experimental investigation of the performance of a supersonic compressor cascade

Supersonic cascade wind tunnel results are presented for a linear, supersonic compressor cascade derived from the near-tip section of a high-throughflow axial flow compressor rotor over the inlet Mach number range of 1.30-1.71. Laser anemometry was used to obtain flow-velocity measurements showing the wave pattern in the entrance region. Attention is given to the unique-incidence relationship for this cascade, which relates the supersonic inlet Mach number to the inlet flow direction. An empirical correlation is obtained for the influence of the independent parameters of back pressure, axial velocity density ratio, and blade element performance.

Tweedt, T. L.↗

Investigation of the Performance of an Axial-Flow-Pump Stage Designed by the Blade-Element Theory: Blade-Element Data

An axial-flow-pump stage was designed by utilizing blade-element methods in conjunction with axial-flow-compressor blade-element theory. This report presents the blade-element data of the pump stage in both the noncavitating and cavitating conditions. The noncavitating blade- element performance is compared with design rules. The results indicated that some modification of the compressor design equations for computing minimum-loss incidence and deviation angles may be necessary for application to an axial-flow-pump design. Minimum values of observed rotor loss were slightly lower than anticipated from compressor results. At the design flow coefficient the rotor-blade elements were not operating at the reference incidence angles, and the experimental efficiency was lower than the design value. The observed head rise was very close to the design. An attempt was made to estimate the potential of this rotor by using the minimum measured values of loss coefficient and observed energy input at the design flow. Performance of the pump at a suction specific speed of approximately 13,000 (cavitation number k approximately equals 0.12) showed only a slight dropoff in performance in the cavitation inception region from the noncavitating results. The observed performance at a suction specific speed of approximately 16,000 (k approximately equals 0.09) is also presented for comparison.

Crouse, James E.↗

Experimental investigation of the performance of a supersonic compressor cascade

Results are presented from an experimental investigation of a linear, supersonic, compressor cascade tested in the supersonic cascade wind tunnel facility at the DFVLR in Cologne, Federal Republic of Germany. The cascade design was derived from the near-tip section of a high-through-flow axial flow compressor rotor with a design relative inlet Mach number of 1.61. Test data were obtained over a range of inlet Mach numbers from 1.23 to 1.71, and a range of static pressure ratios and axial-velocity-density ratios (AVDR) at the design inlet condition. Flow velocity measurements showing the wave pattern in the cascade entrance region were obtained using a laser transit anemometer. From these measurements, some unique-incidence conditions were determined, thus relating the supersonic inlet Mach number to the inlet flow direction. The influence of static pressure ratio and AVDR on the blade passage flow and the blade-element performance is described, and an empirical correlation is used to show the influence of these two (independent) parameters on the exit flow angle and total-pressure loss for the design inlet condition.

Tweedt, D. L.↗

Transient performance of fan engine with water ingestion

In a continuing investigation on effects of rain-water ingestion into bypass fan engines, it is shown that the performance of axial-flow compressors and fans is fundamentally time-dependent during ingestion of water. A code named WINCOF-I has been developed for establishing the performance of axial-flow turbomachinery operating with air-water vapor-water droplet-water film mixture, Illustrative examples of predictions and effects are provided for the case of the air-compression system of a generic bypass fan engine. Utilizing performance maps so-generated, the effects of water ingestion into the generic engine have been determined under test cell conditions simulating ingestion, flight operation (altitude and flight Mach number), and power-demand setting.

Murthy, S. N. B.↗