Search NASA⌕ Search

SEARCH · Search NASA

Results for “Activity coefficient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Rapid Bayesian High Entropy Alloy Designs Fabricated via Wire Arc Additive Manufacturing

Purpose: This project seeks to demonstrate a new high-throughput (rapid) alloy design technique applied to creating new high entropy alloys (HEAs) for extreme environments. High entropy alloys shift the design paradigm from being focused on a single principal element (e.g. nickel-based alloys) to target alloys that include high atomic fractions (X >10%) of multiple elements. These HEA materials can exhibit sluggish diffusion and enhanced corrosion resistance, ideal for potential applications in advanced ultra supercritical (A-USC) steam cycles for power generation. Scope: The addition of multiple elements in high atomic fractions creates an enormous design space that cannot easily be investigated by traditional material design strategies such as designed of experiments (DOE). This project utilizes a Bayesian machine learning algorithm that has been modified to work with calculation of phase diagrams (CALPHAD) software. This Bayesian algorithm reduces manual inputs and increase the likelihood of achieving an optimal solution. Compositional inputs to this algorithm will be assessed using existing material property models for high temperature strength and corrosion resistance. The target for alloy performance will be a 15% (~100 ⁰C) increase in allowable service temperature beyond heat-resistant stainless steels while maintaining or improving alloy cost and corrosion resistance. Haynes 230 was selected as a baseline, which is 57 wt% Ni with 22 wt% Cr 14 wt% W, and 2 wt% Mo as solid solution strengtheners. In addition to rapid design via Bayesian machine learning, the alloys were rapidly fabricated using a multi-wire arc additive manufacturing (mWAAM) technique which allows for precise control of alloy composition and assessing of alloy design “windows” to study composition effects. Build speeds for wire-arc additive processes are among the highest for additive technologies enabling rapid and reliable sample fabrication when compared to conventional methods such as arc button melting. The mWAAM samples will be rapidly characterized via instrumented indentation for room temperature modulus and strength and for elevated temperature strength via hot hardness tests. After being screened with hardness testing, potential alloys will be further evaluated with conventional microscopy techniques including scanning electron microscopy (SEM) and transmission electron microscopy (TEM) to assess agreement with modeling results. The most promising compositions will also be evaluated by printing full sized tensile specimens for mechanical behavior tests at elevated temperatures. Results: Bayesian machine learning of a single performance function was initially used to optimize five performance metrics: 1) single phase stability, 2) yield strength, 3) creep resistance (low diffusion coefficient), 4) freezing range (weldability), and 5) material cost. The single performance function was suboptimal as assumptions had to be made about the results while formulating the optimization. A goal-oriented Bayesian optimization strategy (Hanaoka, 2021) was implemented with CALPHAD for use with the five metrics above. This multi-objective Bayesian optimization (MOBO) enabled the design of NiCrCoFe alloys with V and W additions. A base composition of NiCoCr was selected as Ni provides a stable FCC matrix, Cr aids corrosion/oxidation resistance, and Co is a solid-solutions strengthener that also improves creep by increasing the activation energy. Fe helps reduce diffusion coefficients and cost. Finally, V and W were selected for their reasonable solubility and high atomic misfit to aid in solid solution strengthening. Cracking of the mWAAM specimens was an early issue, and the Easton solidification cracking model (Easton et al., 2014a) was selected for addition to the MOBO function. High performing alloys fabricated by mWAAM included Ni 28 Cr 25 Co 26 Fe 15 V 8 and Ni 62 Cr 18 Co 1 Fe 3 W 15 . It was observed that even after adapting the mWAAM process for W, the W did not fully dissolve. To fully evaluate the Ni 62 Cr 18 Co 1 Fe 3 W 15 composition, a cored wire (80-20 NiCr sheath/powder core) was manufactured and printed via WAAM, and HIP’ing was utilized to homogenize and densify the printed alloy. The V and W alloys produced met metrics 1 (solid solution), 4 (solidification cracking), and 5 (cost). However, an unmodeled mechanism of thermal stress cracking was identified in the WAAM produced materials, perhaps exacerbated by the lack of grain boundary strengthening elements (B, C). Conclusions & Recommendations: A high-throughput (rapid) alloy design technique was applied to designing and manufacturing new high entropy alloys (HEAs) for extreme environments utilizing MOBO and mWAAM. The developed process was rapid and effective in addressing the mechanisms included in the model. The lack of grain boundary strengthening element additions (e.g., B, C) was a simplification that likely produced thermal stress cracking that turned into a large part of the investigation. Additions on the order of 0.005 wt% B and 0.05 wt% C likely would have minimized thermal stress grain boundary cracking. Overall, the high throughput design strategy is promising for rapid design of metrics-driven alloys for advanced ultra supercritical (A-USC) steam cycles for power generation. The MOBO and mWAAM process could be commercialized to accelerate metrics-driven alloy design. In addition, the cored-wire process utilized for scale-up is a promising high-volume process for WAAM alloy development and scale-up.

36 MATERIALS SCIENCE↗

Automated evaluation of setup errors in carbon ion therapy using PET: Feasibility study

Purpose: To investigate the possibility of detecting patient mispositioning in carbon-ion therapy with particle therapy positron emission tomography (PET) in an automated image registration based manner. Methods: Tumors in the head and neck (H and N), pelvic, lung, and brain region were investigated. Biologically optimized carbon ion treatment plans were created with TRiP98. From these treatment plans, the reference β{sup +}-activity distributions were calculated using a Monte Carlo simulation. Setup errors were simulated by shifting or rotating the computed tomography (CT). The expected β{sup +} activity was calculated for each plan with shifts. Finally, the reference particle therapy PET images were compared to the “shifted” β{sup +}-activity distribution simulations using the Pearson's correlation coefficient (PCC). To account for different PET monitoring options the inbeam PET was compared to three different inroom scenarios. Additionally, the dosimetric effects of the CT misalignments were investigated. Results: The automated PCC detection of patient mispositioning was possible in the investigated indications for cranio-caudal shifts of 4 mm and more, except for prostate tumors. In the rather homogeneous pelvic region, the generated β{sup +}-activity distribution of the reference and compared PET image were too much alike. Thus, setup errors in this region could not be detected. Regarding lung lesions the detection strongly depended on the exact tumor location: in the center of the lung tumor misalignments could be detected down to 2 mm shifts while resolving shifts of tumors close to the thoracic wall was more challenging. Rotational shifts in the H and N and lung region of +6° and more could be detected using inroom PET and partly using inbeam PET. Comparing inroom PET to inbeam PET no obvious trend was found. However, among the inroom scenarios a longer measurement time was found to be advantageous. Conclusions: This study scopes the use of various particle therapy PET verification techniques in four indications. The automated detection of patients' setup errors was investigated in a broad accumulation of data sets. The evaluation of introduced setup errors is performed automatically, which is of utmost importance to introduce highly required particle therapy monitoring devices into the clinical routine.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Insights into the soft brittle-to-ductile transition from discrete dislocation dynamics

The Brittle-to-ductile transition (BDT) in body centered cubic metals exhibits a soft transition wherein the fracture toughness gradually rises to before the onset of ductility. The resultant brittle-to-ductile transition temperature can be described with an Arrhenius relationship whose activation energy is related to plasticity in the material. To provide further insight into the nature of the BDTT, in this work we utilized a discrete dislo- cation dynamics model with a crack to simulate the BDT and how it depends on the thermally activated nature of plasticity. The interrelationship between the BDT activation energy and the dislocation mobility parameters were determined via the calculation of first order sensitivity coefficients. This analysis allows us to demonstrate that the activation energy for the BDT is directly related to the activation energy for plasticity through an effective stress that defines this relationship. This effective stress physically is the average stress on the dislocations that move out of the crack. Lastly, we are able to show that this effective stress is dictated by the low temperature fracture toughness or cleave energy of the material and the source position, the latter of which can be affected by processing. Collectively, these results provide new insight into what controls the thermal activation of the BDT and what are the important parameters to control it.

36 MATERIALS SCIENCE↗

Speciation and diffusive dynamics in hydrated grain boundaries of complex oxide Gd2Ti2O7

Abstract Grain boundaries in polycrystalline materials significantly affect their properties, such as ionic transport, corrosion, and chemical durability. The pyrochlore compound (Gd 2 Ti 2 O 7 ) is employed as a model for complex oxides and is known for its diverse applications, including nuclear waste immobilization. Density functional theory-based first-principles molecular dynamics simulations were performed at different temperatures on the hydrated grain boundary system. The results show extensive transformations within the grain boundaries among hydrous water species (OH − , H 2 O, and H 3 O + ). The temperature dependence of self-diffusion coefficients follows Arrhenius behavior, with an activation energy of 35.9 kJ/mol for hydrogen and 46.3 kJ/mol for oxygen. The lifetime of OH − is about three to four times longer than that of H 2 O at temperatures from 800 to 2100 K, suggesting the greater stability of OH − over H 2 O, a unique characteristic of the grain boundaries. The estimated lifetime of the hydrous species decreases as the temperature increases, with an activation energy of 9.9 kJ/mol for OH − and 13.4 kJ/mol for H 2 O. While Gd 3 + is more mobile than Ti 4+ , both the Gd 3 + and Ti 4+ cations are orders of magnitude less mobile than the water species. The results suggest that water species are much more mobile within grain boundaries than in the bulk crystal and have the potential to penetrate deep into polycrystalline materials through grain boundaries, leading to grain boundary degradation and dissolution. The different mobilities of cations in complex oxides can lead to leaching of certain cations and incongruent dissolution during the chemical weathering of Earth and industrial materials.

B. Ghosh, Dipta↗

Characterization of the indoor near-field aerosol transmission in a model commercial office building

To evaluate the exposure potential of infectious aerosols containing SARS-CoV-2 in an office building setting, synthetic test aerosols were used to experimental study airborne particle transmission in a multizone small office test building at the Oak Ridge National Laboratory. Nine measurement points in a single zone using active aerosol impactors report that the coefficient of variation of the time-averaged concentration is <10% in two campaigns and < 15% in one campaign, so a nearly well-mixed condition was noted. To understand the effect of HVAC system operation on the dynamic concentration of aerosols in office spaces, an aerosol transport model that includes factors such as outside air (OA) ratio, filtration, return air fraction, transport loss in air ducts, and particle deposition has been developed. The results of model fitting demonstrate strong agreement with experimental data. Overall, our investigation finds the return air fraction effects outweigh other mechanisms for the aerosol recirculation in this study, and the impact of air change rate (ACR) is more important than the small particle deposition for aerosol removal. Because ACR dominates the aerosol transport, the full model can be simplified to just one factor, the ACR, while maintaining an acceptable representation of the experimental data.

60 APPLIED LIFE SCIENCES↗

Diffusion in undoped and Cr-doped amorphous UO 2

UO 2 fuel pellets are often doped with chromium oxide to obtain favourable properties such as higher density, improved thermal stability, large grain sizes, improved pellet-clad interaction margins, and increased fission gas retention during transients. Chromium has a low solubility limit in UO 2 , with past experimental work reporting solubility limits ranging between 0.004 to 0.06 wt.% Cr. Due to its low solubility, segregation of Cr ions to the grain boundary may occur. Further, the complexity of these boundaries may be high as observed in other ceramics resulting in disordered or amorphous regions along the boundary, affecting a range of material and operational properties of the fuel pellet. To assess these disordered regions, in this work we study amorphous undoped and Cr doped UO 2 systems (containing 10–50 at.% Cr 3+ ) that have been modelled using classical molecular dynamics methods incorporating Cr 3+ into the well-used CRG potential library. Diffusion coefficients, pre-exponential factors, and activation energies for diffusion were computed for oxygen ions, assessing the impact of structure and extrinsic species on migration. Oxygen diffusion was observed to be much faster in the undoped amorphous system compared to its crystalline counterpart. Oxygen diffusion in doped systems decreased with increasing Cr concentration, highlighting the importance of additives to retain fission products and other migratory species.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Dispersion controlled by permeable surfaces: surface properties and scaling

Permeable and porous surfaces are common in natural and engineered systems. Flow and transport above such surfaces are significantly affected by the surface properties, e.g. matrix porosity and permeability. However, the relationship between such properties and macroscopic solute transport is largely unknown. In this work, we focus on mass transport in a two-dimensional channel with permeable porous walls under fully developed laminar flow conditions. By means of perturbation theory and asymptotic analysis, we derive the set of upscaled equations describing mass transport in the coupled channel–porous-matrix system and an analytical expression relating the dispersion coefficient with the properties of the surface, namely porosity and permeability. Our analysis shows that their impact on the dispersion coefficient strongly depends on the magnitude of the Péclet number, i.e. on the interplay between diffusive and advective mass transport. Additionally, we demonstrate different scaling behaviours of the dispersion coefficient for thin or thick porous matrices. Our analysis shows the possibility of controlling the dispersion coefficient, i.e. transverse mixing, by either active (i.e. changing the operating conditions) or passive mechanisms (i.e. controlling matrix effective properties) for a given Péclet number. By elucidating the impact of matrix porosity and permeability on solute transport, our upscaled model lays the foundation for the improved understanding, control and design of microporous coatings with targeted macroscopic transport features.

36 MATERIALS SCIENCE↗

Surface Phenomena and Parameters of Crystal Growth: Simple Basics

Basic concepts of crystal growth and their practical use to semi-quantitatively estimate growth processes are explained: surface energy and free energy, driving force of crystallization, atomically rough vs smooth interface structure and the corresponding normal vs layer-by-layer growth modes, application of the activated complex concept to derive kinetic coefficient characterizing crystal growth rate at a given driving force. The Reader is supposed to be familiar with general physics and chemistry. No specific knowledge in crystal growth is required.

36 MATERIALS SCIENCE↗

Studies on Nanocrystalline Bismuth Telluride

Nanostructured thermoelectric bismuth telluride powders with various hydrothermal synthesis times were synthesised to give an experimental comprehension on the formation of the nanopowders. Nanoparticles were synthesised at 130 deg. C for 24 h and 72 h. Bi{sub 2}Te{sub 3} nanoparticles with grain sizes 120A and 170A exhibit n-type semiconducting behaviour with a decrease in Seebeck coefficient with increasing temperature range. The activation energy ({Delta}E{sub S}) calculated from S vs. 1000/T graphs decreases with increasing synthesis time. This variation in {Delta}E{sub S} with synthesis time of the Bi{sub 2}Te{sub 3} nanomaterial may be due to the small amount unreacted carrier content in the material.

36 MATERIALS SCIENCE↗

Radiation assessment to paediatric with F-18-FDG undergo whole-body PET/CT examination

This study was carried out on wholebody radiation dose assessment to paediatrics patient who undergo PET/CT scanner at Institut Kanser Negara. Consist of 68 patients with varies of malignancies and epilepsy disease case covering age between 2 years to 12 years old. This is a retrospective study from 2010-2014. The use of PET/CT scanner as an advanced tool has been proven to give an extra radiation dose to the patient. It is because of the radiation exposure from the combination of both CT and PET scans rather than a single CT or PET scan. Furthermore, a study on radiation dose to paediatric patient undergoing PET/CT is rare in Malaysia. So, the aim of this study is to estimate the wholebody effective dose to paediatric patient in Malaysia. Effective dose from PET scan was calculated based on the activity of F18 FDG and dose coefficient reported in International Commission on Radiological Protection (ICRP) Publication 106. Effective dose from CT was determined using k coefficient as reported in ICRP publication 102 and Dose Length Product (DLP) value. The average effective dose from PET and CT were found to be 7.05mSv and 5.77mSv respectively. The mean wholebody effective dose received by a patient with combined PETCT examination was 12.78mSv. These results could be used as reference for dosimetry of a patient undergoing PETCT examination in Malaysia.

07 ISOTOPE AND RADIATION SOURCES↗

Individual and Simultaneous Imaging of ⁹⁹mTc and ¹⁷⁷Lu With a Preclinical Broad Energy-Spectrum CZT-Based SPECT

Radiopharmaceutical therapy has demonstrated a high efficacy in the treatment of various tumor types. One of the radionuclides already used in the clinic is 177Lu, a beta emitter that also emits several photons imageable with SPECT. Quantitative imaging of 177Lu is critical for developing new radiopharmaceuticals. Energy resolution is an important factor when imaging multiple photon emissions. Solid-state detectors offer a superior performance over scintillators, that are commonly used in commercially-available preclinical SPECT scanners. This study demonstrates the feasibility of 99m Tc and 177Lu quantitative imaging in mouse phantoms, individually and simultaneously, with a SPECT prototype built with four CdZnTe (CZT) detector heads and a custom-designed and energy-optimized parallel-hole tungsten collimator. With a custom implementation of the one-step late (OSL) image reconstruction algorithm, the system is capable of imaging energies from ~70 keV to 250 keV. Above 250 keV, images were significantly affected by septal penetration, consistent with the collimator design. A recovery coefficient within 25% was obtained for activities as low as 2 kBq/mL for 99m Tc and 45% for 177Lu. Compared to a commercial NaI-based preclinical SPECT (VECTor4/CT), our prototype showed a superior energy resolution (< 5% at 140 keV), a similar uniformity with a high-compact design.

Encarnação, Pedro M C C↗

Emissivity of Laser-Activated Pd–Ba Alloy

Comparative analysis of the influence of temperature and laser activation on the secondary electron emission coefficient and work function (eφ) in Pd–Ba alloy (1.5 at % Ba) has been conducted. The optimum density of laser radiation has been shown to roughly equal 2 J/cm{sup 2}. Reasons why the emission efficiency of Pd–Ba alloy decreases after long-term heating have been found.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Comparative Evaluation of U.S. Brand and Generic Intravenous Sodium Ferric Gluconate Complex in Sucrose Injection: Physicochemical Characterization

The objective of this study was to evaluate physicochemical equivalence between brand (i.e., Ferrlecit) and generic sodium ferric gluconate (SFG) in sucrose injection by conducting a series of comparative in vitro characterizations using advanced analytical techniques. The elemental iron and carbon content, thermal properties, viscosity, particle size, zeta potential, sedimentation coefficient, and molecular weight were determined. There was no noticeable difference between brand and generic SFG in sucrose injection for the above physical parameters evaluated, except for the sedimentation coefficient determined by sedimentation velocity analytical ultracentrifugation (SV-AUC) and molecular weight by asymmetric field flow fractionation-multi-angle light scattering (AFFF-MALS). In addition, brand and generic SFG complex products showed comparable molecular weight distributions when determined by gel permeation chromatography (GPC). The observed minor differences between brand and generic SFG, such as sedimentation coefficient, do not impact their biological activities in separate studies of in vitro cellular uptake and rat biodistribution. Coupled with the ongoing clinical study comparing the labile iron level in healthy volunteers, the FDA-funded post-market studies intended to illustrate comprehensive surveillance efforts ensuring safety and efficacy profiles of generic SFG complex in sucrose injection, and also to shed new light on the approval standards on generic parenteral iron colloidal products.

60 APPLIED LIFE SCIENCES↗

Defect identification based on first-principles calculations for deep level transient spectroscopy

Deep level transient spectroscopy (DLTS) is used extensively to study defects in semiconductors. We demonstrate that great care should be exercised in interpreting activation energies extracted from DLTS as ionization energies. We show how first-principles calculations of thermodynamic transition levels, temperature effects of ionization energies, and nonradiative capture coefficients can be used to accurately determine actual activation energies that can be directly compared with DLTS. Our analysis is illustrated with hybrid-functional calculations for two important defects in GaN, which have similar thermodynamic transition levels and shows that the activation energy extracted from DLTS includes a capture barrier that is temperature dependent, unique to each defect, and, in some cases, large in comparison to the ionization energy. By calculating quantities that can be directly compared with the experiment, first-principles calculations thus offer powerful leverage in identifying the microscopic origin of defects detected in DLTS.

Activation energies↗

Usefulness of specific calibration coefficients for gamma-emitting sources measured by radionuclide calibrators in nuclear medicine

Purpose: In nuclear medicine, the activity of a radionuclide is measured with a radionuclide calibrator that often has a calibration coefficient independent of the container type and filling. Methods: To determine the effect of the container on the accuracy of measuring the activity injected into a patient, The authors simulated a commercial radionuclide calibrator and 18 container types most typically used in clinical practice. The instrument sensitivity was computed for various container thicknesses and filling levels. Monoenergetic photons and electrons as well as seven common radionuclides were considered. Results: The quality of the simulation with gamma-emitting sources was validated by an agreement with measurements better than 4% in five selected radionuclides. The results show that the measured activity can vary by more than a factor of 2 depending on the type of container. The filling level and the thickness of the container wall only have a marginal effect for radionuclides of high energy but could induce differences up to 4%. Conclusions: The authors conclude that radionuclide calibrators should be tailored to the uncertainty required by clinical applications. For most clinical cases, and at least for the low-energy gamma and x-ray emitters, measurements should be performed with calibration coefficients specific to the container type.

61 RADIATION PROTECTION AND DOSIMETRY↗

Electric Power Consumption Coefficients for U.S. Industries: Regional Estimation and Analysis

Economic activity relies on electric power provided by electrical generation, transmission, and distribution systems. This paper presents a method developed at Los Alamos National Laboratory to estimate electric power consumption by different industries in the United States. Results are validated through comparisons with existing literature and benchmarking data sources. We also discuss the limitations and applications of the presented method, such as estimating indirect electric power consumption and assessing the economic impact of power outages based on input-output economic models.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effect of magnetic fields on spin glass dynamics

The effects of a magnetic field on spin glass dynamics are explored for a Cu 0.887 Mn 0.113 thin film of thickness L = 20 nm in a multilayer configuration. An experimental protocol removes uncertainties associated with the time dependence of the field-cooled magnetization M FC (t,T). Activated dynamics is exhibited after the spin glass correlation length ξ(t,T) has reached L, creating a quasiequilibrium state. Here, the activation energy depends upon the strength of the magnetic field H. The magnitude of the activation energy diminishes as H 2 , the coefficient of which is proportional to the number of correlated spins. A quantitative fit requires a “pancakelike” correlated region, associated with the T = 0 phase transition for a spin glass in D = 2 dimensions.

36 MATERIALS SCIENCE↗