Search NASA⌕ Search

SEARCH · Search NASA

Results for “Advanced Photon Source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Note: A novel method for in situ loading of gases via x-ray induced chemistry

We have developed and demonstrated a novel method to load oxygen in a sealed diamond anvil cell via the x-ray induced decomposition of potassium chlorate. By irradiating a pressurized sample of an oxidizer (KClO{sub 3}) with either monochromatic or white beam x-rays from the Advanced Photon Source at ambient temperature and variable pressure, we succeeded in creating a localized region of molecular oxygen surrounded by unreacted sample which was confirmed via Raman spectroscopy. We anticipate that this technique will be useful in loading even more challenging, difficult-to-load gases such as hydrogen and also to load multiple gases.

08 HYDROGEN↗

Phase contrast imaging of cochlear soft tissue.

A noninvasive technique to image soft tissue could expedite diagnosis and disease management in the auditory system. We propose inline phase contrast imaging with hard X-rays as a novel method that overcomes the limitations of conventional absorption radiography for imaging soft tissue. In this study, phase contrast imaging of mouse cochleae was performed at the Argonne National Laboratory Advanced Photon Source. The phase contrast tomographic reconstructions show soft tissue structures of the cochlea, including the inner pillar cells, the inner spiral sulcus, the tectorial membrane, the basilar membrane, and the Reissner's membrane. The results suggest that phase contrast X-ray imaging and tomographic techniques hold promise to noninvasively image cochlear structures at an unprecedented cellular level.

43 PARTICLE ACCELERATORS↗

A compact design of a temperature gradient furnace for synchrotron microradiography

A compact, convenient and economic design of a temperature gradient furnace for synchrotron microradiography is described. The thermal control of the furnace, in terms of cooling rate and temperature gradient, was achieved by programmable temperature controllers, and provided necessary thermal conditions for real time observations of dendritic solidification in real alloys. The experiments at the Advanced Photon Source (APS), Argonne National Laboratory (ANL) demonstrate that the design is well suited to the melting and solidification of alloys with liquidus temperatures up to intermediate ranges ({approx}650 C), such as aluminium alloys. Real time observations with this furnace of dendritic solidification in Al-25 wt% Cu alloy by synchrotron microradiography show interesting and promising results.

36 MATERIALS SCIENCE↗

A Survey of Students from the National School on Neutron and X-ray Scattering: Communication Habits and Preferences

Oak Ridge National Laboratory (ORNL) offers the scientific community unique access to two types of world-class neutron sources at a single site - the Spallation Neutron Source (SNS) and the High Flux Isotope Reactor (HFIR). The 85-MW HFIR provides one of the highest steady-state neutron fluxes of any research reactor in the world. And the SNS is one of the world's most intense pulse neutron beams. Management of these resources is the responsibility of the Neutron Sciences Directorate (NScD). NScD started conducting the National School on Neutron and X-ray Scattering (NXS) in conjunction with the Advanced Photon Source (APS) at Argonne National Laboratory in 2007. This survey was conducted to determine the most effective ways to reach students with information about what SNS and HFIR offer the scientific community, including content and communication vehicles. The emphasis is on gaining insights into compelling messages and the most effective channels, e.g., Web sites and social media, for communicating with students about neutron science The survey was conducted in two phases using a classic qualitative investigation to confirm language and content followed by a survey designed to quantify issues, assumptions, and working hypotheses. Phase I consisted of a focus group in late June 2010 with students attending NXS. The primary intent of the group was to inform development of an online survey. Phase two consisted of an online survey that was developed and pre-tested in July 2010 and launched on August 9, 2010 and remained in the field until September 9, 2010. The survey achieved an overall response rate of 48% for a total of 157 completions. The objective of this study is to determine the most effective ways to reach students with information about what SNS and HFIR offer the scientific community, including content and communication vehicles. The emphasis is on gaining insights into compelling messages and the most effective channels, e.g., Web sites, social media, for communicating with students about neutron science.

43 PARTICLE ACCELERATORS↗

Precision X-ray Measurement of the Position Sensitivity of Graphene Field Effect Transistors

We have been exploring the graphene field-effect transistor (GFET) as a platform for detection of ionizing radiation, whereby the detection is achieved indirectly by use of the field effect in graphene, which is induced by the generation and transport of ionized charge carriers in the underlying undoped semiconductor substrate. An important characteristic of such a detector is scalability to large areas. Previous experimental studies suggest that the effective area significantly exceeds the size of graphene for field effect-based architectures, and this is also predicted from the operational principle of these devices. We describe the results of the experimental studies of GFETs on silicon carbide (SiC) substrates by use a microbeam Xray facility, provided by the Advanced Photon Source at Argonne National Laboratory. The results confirm that the effective area of the GFET is significantly larger than that of graphene with response measured at distances as large as 1000 μm from 10-μm size graphene. A simple transport model has been developed and is used to explain the spatial dependence of the GFET response. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Argonne National Laboratory annual report of Laboratory Directed Research and Development Program Activities FY 2009.

I am pleased to submit Argonne National Laboratory's Annual Report on its Laboratory Directed Research and Development (LDRD) activities for fiscal year 2009. Fiscal year 2009 saw a heightened focus by DOE and the nation on the need to develop new sources of energy. Argonne scientists are investigating many different sources of energy, including nuclear, solar, and biofuels, as well as ways to store, use, and transmit energy more safely, cleanly, and efficiently. DOE selected Argonne as the site for two new Energy Frontier Research Centers (EFRCs) - the Institute for Atom-Efficient Chemical Transformations and the Center for Electrical Energy Storage - and funded two other EFRCs to which Argonne is a major partner. The award of at least two of the EFRCs can be directly linked to early LDRD-funded efforts. LDRD has historically seeded important programs and facilities at the lab. Two of these facilities, the Advanced Photon Source and the Center for Nanoscale Materials, are now vital contributors to today's LDRD Program. New and enhanced capabilities, many of which relied on LDRD in their early stages, now help the laboratory pursue its evolving strategic goals. LDRD has, since its inception, been an invaluable resource for positioning the Laboratory to anticipate, and thus be prepared to contribute to, the future science and technology needs of DOE and the nation. During times of change, LDRD becomes all the more vital for facilitating the necessary adjustments while maintaining and enhancing the capabilities of our staff and facilities. Although I am new to the role of Laboratory Director, my immediate prior service as Deputy Laboratory Director for Programs afforded me continuous involvement in the LDRD program and its management. Therefore, I can attest that Argonne's program adhered closely to the requirements of DOE Order 413.2b and associated guidelines governing LDRD. Our LDRD program management continually strives to be more efficient. In addition to meeting all reporting requirements during fiscal year 2009, our LDRD Office continues to enhance its electronic systems to streamline the LDRD management process. You will see from the following individual project reports that Argonne's researchers have once again done a superb job pursuing projects at the forefront of their respective fields and have contributed significantly to the advancement of Argonne's strategic thrusts. This work has not only attracted follow-on sponsorship in many cases, but is also proving to be a valuable basis upon which to continue realignment of our strategic portfolio to better match the Laboratory's Strategic Plan.

43 PARTICLE ACCELERATORS↗

JBluIce-EPICS control system for macromolecular crystallography.

The trio of macromolecular crystallography beamlines constructed by the General Medicine and Cancer Institutes Collaborative Access Team (GM/CA-CAT) in Sector 23 of the Advanced Photon Source (APS) have been in growing demand owing to their outstanding beam quality and capacity to measure data from crystals of only a few micrometres in size. To take full advantage of the state-of-the-art mechanical and optical design of these beamlines, a significant effort has been devoted to designing fast, convenient, intuitive and robust beamline controls that could easily accommodate new beamline developments. The GM/CA-CAT beamline controls are based on the power of EPICS for distributed hardware control, the rich Java graphical user interface of Eclipse RCP and the task-oriented philosophy as well as the look and feel of the successful SSRL BluIce graphical user interface for crystallography. These beamline controls feature a minimum number of software layers, the wide use of plug-ins that can be written in any language and unified motion controls that allow on-the-fly scanning and optimization of any beamline component. This paper describes the ways in which BluIce was combined with EPICS and converted into the Java-based JBluIce, discusses the solutions aimed at streamlining and speeding up operations and gives an overview of the tools that are provided by this new open-source control system for facilitating crystallographic experiments, especially in the field of microcrystallography.

43 PARTICLE ACCELERATORS↗

Microfabrication of controlled-geometry samples for the laser-heated diamond-anvil cell using focused ion beam technology

The pioneering of x-ray diffraction with in situ laser heating in the diamond-anvil cell has revolutionized the field of high-pressure mineral physics, expanding the ability to determine high-pressure, high-temperature phase boundaries and equations of state. Accurate determination of high-pressure, high-temperature phases and densities in the diamond-anvil cell rely upon collinearity of the x-ray beam with the center of the laser-heated spot. We present the development of microfabricated samples that, by nature of their design, will have the sample of interest in the hottest portion of the sample. We report initial successes with a simplified design using a Pt sample with dimensions smaller than the synchrotron-based x-ray spot such that it is the only part of the sample that absorbs the heating laser ensuring that the x-rayed volume is at the peak hotspot temperature. Microfabricated samples, synthesized using methods developed at The Ohio State University's Mineral Physics Laboratory and Campus Electron Optics Facility, were tested at high P-T conditions in the laser-heated diamond-anvil cell at beamline 16 ID-B of the Advanced Photon Source. Pt layer thicknesses of {le} 0.8 {micro}m absorb the laser and produce accurate measurements on the relative equations of state of Pt and PtC. These methods combined with high-purity nanofabrication techniques will allow for extension by the diamond-anvil cell community to multiple materials for high-precision high-pressure, high-temperature phase relations, equations of state, melting curves, and transport properties.

43 PARTICLE ACCELERATORS↗

An equivalent circuit model and power calculations for the APS SPX crab cavities

An equivalent parallel resistor-inductor-capacitor (RLC) circuit with beam loading for a polarized TM110 dipole-mode cavity is developed and minimum radio-frequency (rf) generator requirements are calculated for the Advanced Photon Source (APS) short-pulse x-ray (SPX) superconducting rf (SRF) crab cavities. A beam-loaded circuit model for polarized TM110 mode crab cavities was derived. The single-cavity minimum steady-state required generator power has been determined for the APS SPX crab cavities for a storage ring current of 200mA DC current as a function of external Q for various vertical offsets including beam tilt and uncontrollable detuning. Calculations to aid machine protection considerations were given.

43 PARTICLE ACCELERATORS↗

Ultra-fast LuI{sub 3}:Ce scintillators for hard x-ray imaging

We have developed ultra-fast cerium-coped lutetium-iodide (LuI{sub 3}:Ce) films thermally evaporated as polycrystalline, structured scintillator using hot wall epitaxy (HWE) method. The films have shown a 13 ns decay compared to the 28 ns reported for crystals. The fast speed coupled with its high density (∼5.6 g/cm{sup 3}), high effective atomic number (59.7), and the fact that it can be vapor deposited in a columnar form makes LuI{sub 3}:Ce an attractive candidate for high frame rate, high-resolution, hard X-ray imaging. In crystal form, LuI{sub 3}:Ce has demonstrated bright (>100,000 photons/MeV) green (540 nm) emission, which is well matched to commercial CCD/CMOS sensors and is critical for maintaining high signal to noise ratio in light starved applications. Here, we report on the scintillation properties of films and those for corresponding crystalline material. The vapor grown films were integrated into a high-speed CMOS imager to demonstrate high-speed radiography capability. The films were also tested at Advanced Photon Source, Argonne National Laboratory beamline 1-ID under hard X-ray irradiation. The data show a factor of four higher efficiency than the reference LuAG:Ce scintillators, high image quality, and linearity of scintillation response over a wide energy range. The films were employed to perform hard X-ray microtomography, the results of which will also be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and Prototype Progress toward a Superconducting Crab Cavity Cryomodule for the APS

A squashed, elliptical supercondconducting (SC) cavity with waveguide dampers on the beam pipes has currently been chosen as the baseline design [1] for the Short Pulse X-ray (SPX) project at the Advanced Photon Source (APS). An alternate cavity design, with a waveguide damper located directly on the cavity cell for improved damping characteristics, has also been designed and cold-tested with promising results. In either case, eight cavities would be operated CW in a single cryomodule at 2K to produce an electron bunch chirp of 4MV at a frequency of 2.815 GHz. Detailed analysis of multipactoring (MP), Lorentz force detuning (LFD), and the thermal properties of the baseline design has led to an engineering specification of the basic parameters of the cryomodule.

43 PARTICLE ACCELERATORS↗

Mitigation of COTR due to the Microbunching Instability in Compressed Electron Beams

We have demonstrated a technique to mitigate the intensity of the coherent OTR (COTR) relative to the OTR signals on the Advanced Photon Source chicane-compressed beams at 325 MeV. Since the reported spectral content of the COTR at LCLS after the first compression stage is similar, the concepts should also apply to LCLS. We utilized the stronger violet content at 400 nm of the OTR compared to the observed gain factors of the COTR in the green to NIR. We also demonstrated the use of an LSO:Ce scintillator that emits violet light to support lower-charge imaging.

43 PARTICLE ACCELERATORS↗

A design concept for a planar superconducting undulator for the APS.

A superconducting planar undulator is under development at the Advanced Photon Source. The R&D phase culminated in the successful testing of several short magnetic structure prototypes. Work is now focused on a complete design for the first undulator. The conceptual designs for its superconducting magnet, the cooling system, and the cryostat are described in this paper.

43 PARTICLE ACCELERATORS↗

Shape-selective catalysts for Fischer-Tropsch chemistry : atomic layer deposition of active catalytic metals. Activity report : January 1, 2005 - September 30, 2005.

Argonne National Laboratory is carrying out a research program to create, prepare, and evaluate catalysts to promote Fischer-Tropsch (FT) chemistry - specifically, the reaction of hydrogen with carbon monoxide to form long-chain hydrocarbons. In addition to needing high activity, it is desirable that the catalysts have high selectivity and stability with respect to both mechanical strength and aging properties. The broad goal is to produce diesel fraction components and avoiding excess yields of both light hydrocarbons and heavy waxes. Originally the goal was to prepare shape-selective catalysts that would limit the formation of long-chain products and yet retain the active metal sites in a protected 'cage.' Such catalysts were prepared with silica-containing fractal cages. The activity was essentially the same as that of catalysts without the cages. We are currently awaiting follow-up experiments to determine the attrition strength of these catalysts. A second experimental stage was undertaken to prepare and evaluate active FT catalysts formed by atomic-layer deposition [ALD] of active components on supported membranes and particulate supports. The concept was that of depositing active metals (i.e. ruthenium, iron or cobalt) upon membranes with well defined flow channels of small diameter and length such that the catalytic activity and product molecular weight distribution could be controlled. In order to rapidly evaluate the catalytic membranes, the ALD coating processes were performed in an 'exploratory mode' in which ALD procedures from the literature appropriate for coating flat surfaces were applied to the high surface area membranes. Consequently, the Fe and Ru loadings in the membranes were likely to be smaller than those expected for complete monolayer coverage. In addition, there was likely to be significant variation in the Fe and Ru loading among the membranes due to difficulties in nucleating these materials on the aluminum oxide surfaces. The first series of experiments using coated membranes demonstrated that the technology needed further improvement. Specifically, observed catalytic FT activity was low. This low activity appeared to be due to: (1) low available surface area, (2) atomic deposition techniques that needed improvements, and (3) insufficient preconditioning of the catalyst surface prior to FT testing. Therefore, experimentation was expanded to the use of particulate silica supports having defined channels and reasonably high surface area. This later experimentation will be discussed in the next progress report. Subsequently, we plan to evaluate membranes after the ALD techniques are improved with a careful study to control and quantify the Fe and Ru loadings. The preconditioning of these surfaces will also be further developed. (A number of improvements have been made with particulate supports; they will be discussed in the subsequent report.) In support of the above, there was an opportunity to undertake a short study of cobalt/promoter/support interaction using the Advanced Photon Source (APS) of Argonne. Five catalysts and a reference cobalt oxide were characterized during a temperature programmed EXAFS/XANES experimental study with the combined effort of Argonne and the Center for Applied Energy Research (CAER) of the University of Kentucky. This project was completed, and it resulted in an extensive understanding of the preconditioning step of reducing Co-containing FT catalysts. A copy of the resulting manuscript has been submitted and accepted for publication. A similar project was undertaken with iron-containing FT catalysts; the data is currently being studied.

08 HYDROGEN↗

Probing the isothermal (delta)->(alpha)' martensitic transformation in Pu-Ga with in situ x-ray diffraction

The time-temperature-transformation (TTT) curve for the {delta} {yields} {alpha}{prime} isothermal martensitic transformation in a Pu-1.9 at. % Ga alloy is peculiar because it is reported to have a double-C curve. Recent work suggests that an ambient temperature conditioning treatment enables the lower-C curve. However, the mechanisms responsible for the double-C are still not fully understood. When the {delta} {yields} {alpha}{prime} transformation is induced by pressure, an intermediate {gamma}{prime} phase is observed in some alloys. It has been suggested that transformation at upper-C temperatures may proceed via this intermediate phase, while lower-C transformation progresses directly from {delta} to {alpha}{prime}. To investigate the possibility of thermally induced transformation via the intermediate {gamma}{prime} phase, in situ x-ray diffraction at the Advanced Photon Source was performed. Using transmission x-ray diffraction, the {delta} {yields} {alpha}{prime} transformation was observed in samples as thin at 30 {micro}m as a function of time and temperature. The intermediate {gamma}{prime} phase was not observed at -120 C (upper-C curve) or -155 C (lower-C curve). Results indicate that the bulk of the {alpha}{prime} phase forms relatively rapidly at -120 C and -155 C.

36 MATERIALS SCIENCE↗

Using a Microcapillary Refractive X-Ray Lens for Focusing And Imaging

The microcapillary lens, formed by air bubbles in a hollow core glass capillary filled with epoxy, is a novel design of a compound refractive lens for X-rays. The epoxy enclosed between two air bubbles has the form of a biconcave lens and acts as a positive lens for X-rays. Each individual lens is spherical with radius of curvature equal to the inner radius of the capillary. Up to 500 individual biconcave lenses can be formed in a single capillary with diameters from 50 to 500 {mu}m. Due to the small radius of curvatures that can be achieved, microcapillary lenses typically have shorter focal lengths than those made by compression or injection molding. For example, microcapillary lenses with a focal length about 5 cm for 8 keV X-rays and 50-micron aperture are readily available. We have produced a set of lenses in a 200-micron inner-diameter glass capillary with 100--350 individual microlenses and measured their parameters at the Stanford Synchrotron Radiation Laboratory and at the Advanced Photon Source. Our investigations have also shown that the lenses are suitable for imaging applications with an X-ray tube as a source of X-rays. A simple X-ray microscope is discussed. The microscope consists of a copper anode X-ray tube, X-ray lens and CCD-camera. The object, lens and CCD-camera were placed in-line at distances to satisfy the lens formula. It is shown that the field of view of the microscope is about 1 mm and resolution is equal to 3--5 {mu}m.

43 PARTICLE ACCELERATORS↗

Synchrotron Microdiffraction Study of Heavy-Ion-Irradiated Uranium-Molybdenum Dispersion Fuel

There has been an ongoing effort by the Department of Energy Office of Material Management and Minimization to convert research and test reactors from high-enriched to low-enriched uranium fuels. Uranium-molybdenum alloy fuel dispersed in an aluminum matrix (UMo-Al dispersion fuel) has emerged as the leading candidate fuel for converting the remaining high-power research reactors in Europe. One of the primary barriers to using this fuel type is the deleterious reaction of UMo with Al. Depending on the operating temperature of the reactor, this interaction layer can be amorphous under irradiation and allows for the accumulation of fission gas products in large bubbles, leading to unacceptable swelling of the fuel. Therefore, detailed characterization of the phases that form within the fuel and in the interaction layer is critical to understanding, and controlling, UMo-Al dispersion fuel behavior under irradiation. Furthermore, the phase stability of the UMo fuel is of great importance, as the alpha-UMo phase has undesirable swelling compared to the metastable gamma-UMo phase. Heavy ion irradiation was used to reproduce the interaction layer that develops in-reactor. Samples of both the fuel and interaction layer formed under ion irradiation were examined using the high-energy x-ray microdiffraction technique at the Advanced Photon Source (APS) at Argonne National Laboratory to examine the microstructure of the interaction layer. The high-resolution phase information obtained in this experiment provides a valuable basis for understanding the evolution of UMo-Al dispersion fuel under irradiation and as input for computational studies to improve predictive capabilities. Phase information for in-pile fuels can currently be determined from TEM samples (limited sample volume, limiting statistics), or by extrapolation from SEMEDS analysis. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of high-repetition-rate laser pump/x-ray probe methodologies for synchrotron facilities

We describe our implementation of a high repetition rate (54 kHz-6.5 MHz), high power (>10 W), laser system at the 7ID beamline at the Advanced Photon Source for laser pump/x-ray probe studies of optically driven molecular processes. Laser pulses at 1.06 {mu}m wavelength and variable duration (10 or 130 ps) are synchronized to the storage ring rf signal to a precision of {approx}250 fs rms. Frequency doubling and tripling of the laser radiation using nonlinear optical techniques have been applied to generate 532 and 355 nm light. We demonstrate that by combining a microfocused x-ray probe with focused optical laser radiation the requisite fluence (with <10 {mu}J/pulse) for efficient optical excitation can be readily achieved with a compact and commercial laser system at megahertz repetition rates. We present results showing the time-evolution of near-edge x-ray spectra of a well-studied, laser-excited metalloporphyrin, Ni(II)-tetramesitylporphyrin. The use of high repetition rate, short pulse lasers as pump sources will dramatically enhance the duty cycle and efficiency in data acquisition and hence capabilities for laser-pump/x-ray probe studies of ultrafast structural dynamics at synchrotron sources.

36 MATERIALS SCIENCE↗