Search NASA⌕ Search

SEARCH · Search NASA

Results for “Air simulations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Mid-Atlantic Turbulence Intensity Data in Observational Space

The dataset archives observed and model-simulated turbulence intensity and meteorological profiles and timeseries at the Air-Sea Interaction Tower (ASIT) of Woods Hole Oceanographic Institution’s Martha’s Vineyard Coastal Observatory (MVCO). The observational data were measured by lidar and buoy deployed at ASIT. The simulated profiles and timeseries data are interpolated in time and/or space according to observations. Simulations were carried out for the mid-Atlantic region using the revised Weather Research and Forecasting (WRF) model version 4.2 that incorporates the implementation of online turbulence intensity (TI) calculations (Tai et al. 2023). The simulated atmospheric profiles at the Shell Exploration and Production Corporation's Tension Leg Platforms Ursa and Mars are archived. Physics parameterizations chosen for the simulations include the Thompson microphysics parameterization, Mellor-Yamada-Nakanishi Niino (MYNN) boundary layer parameterization, Mellor-Yamada-Janjic surface layer parameterization, Unified Noah land-surface parameterization, and the RRTMG longwave and shortwave radiation parameterization. Initial and boundary conditions are taken from NOAA’s High-Resolution Rapid Refresh (HRRR) product. The JPL 0.01-degree Level 4 Multiscale Ultrahigh Resolution (MUR) Global Foundation Sea Surface Temperature (SST) Analysis (V4.1) data are used as the model’s SST forcing.

17 WIND ENERGY↗

Detailed chemistry modeling of rotating detonations with dilute n -heptane sprays and preheated air

Utilization of liquid fuels is crucial to enabling commercialization of rotating detonation engines (RDE) in the near future. In this study, Eulerian-Lagrangian simulations are conducted for rotating detonative combustion with dilute n-heptane sprays and preheated air. Two-dimensional flattened configuration is used and a skeletal chemical mechanism with 44 species and 112 elementary reactions for n-heptane combustion is adopted. The flow structure, droplet distribution, and thermochemical parameters in the refill zone are first analyzed. It is shown that the mixture in the refill zone is heterogeneous, including evaporating droplets, vapor, and air. When the total temperature is below 950 K, the average equivalence ratio increases with the total temperature. When it is higher than 950 K, the average equivalence ratio is almost constant. Subsequently, the chemical explosive mode analysis is applied to identify the controlling reactions and dominant combustion modes in the fuel refill zone and reaction fronts. Results demonstrate that the initiation reaction (R104: n-C 7 H 16 + O 2 2-C 7 H 15 + HO 2 ) and low-temperature reaction (R107: RO 2 R'O 2 H) are dominant in the upstream and downstream of the refill zone, respectively. The intermediate species from low-temperature chemistry, R'O 2 H, is found to be important for the chemical explosive mode in the undetonated mixture. The influence of species diffusion and dispersed droplets is further analyzed. Results show that vapor autoignition facilitated by droplet evaporation occurs in the refill zone. Finally, the effects of the air total temperature on the detonation propagation speed and RDE propulsion performance are investigated. Further, it is found that the detonation propagation speed and specific impulse increase with air total temperature. The total pressure ratio first increases and then decreases as the air total temperature increases. Moreover, when the total temperature of the preheated air is above 1,300 K, the effects of low-temperature chemistry are negligible.

33 ADVANCED PROPULSION SYSTEMS↗

Recovery of Natural Gas Equipment Emissions into Gas Compression Engines for the Reduction of Potential Greenhouse Gas Emissions

Since the turn of the millennium, the United States (U.S.) oil and natural gas (ONG) industry has nearly doubled its natural gas production rate. As a result, the ONG industry has recently come under increasing scrutiny for its contributions to greenhouse gas (GHG) emissions. Consequently, various solutions to this problem have been proposed and formulated to reduce the impacts of GHG emissions on the environment. West Virginia University (WVU) have found it important to research the impacts of recovering vented gas streams into prime-mover engines. The U.S. Department of Energy (DOE) and National Energy Technology Laboratory (NETL) have granted WVU funding to research and develop a “Methane Mitigator” (M2) - a “Scalable Vent Mitigation Strategy to Simultaneously Reduce Methane Emissions and Fuel Consumption from the Compression Industry.” One of the main areas of interest for this research was the collection of emissions from natural gas equipment into a Caterpillar G3508J natural gas compression engine. The parameters being analyzed from the engine were brake-specific emissions and power output. The emissions sources considered for this research were pneumatic controllers (PCs), reciprocating compressor vents, and the engine’s open crankcase breather. The compressor vent and PC emissions were simulated using a mass flow controller (MFC) and flowed into the engine using two separate methods: (1) directly into the air intake, and (2) through a retrofitted closed crankcase ventilation system (CCV), serving as a buffer volume. The crankcase emissions were quantified without the CCV, and the impact on exhaust emissions from circulating the crankcase gases into the intake was measured. The simulated compressor vent and PC flows from the MFC had limited effect on the steady state operation of the engine and resulting performance. When the simulated flows were fed directly into the engine’s air intake, the changes within the engine’s continuous performance and emission parameters were larger but lasted for shorter durations. Conversely, when the simulated flows were fed into the CCV before entering the air intake, the changes in the engine’s performance and emission parameters were less pronounced for continuous analysis but lasted for longer durations. In either case, the continuous emission changes in both emissions and performance varied in size depending on the test scenario being run, but the cycle average changes in emissions and performance showed little impact overall compared to the engine’s baseline operation. As a result, the inclusion of a CCV shows a decrease in baseline carbon dioxide equivalent (CO2-eq.) engine emissions (from combined exhaust and open crankcase) of almost 4%. Likewise, the CCV inclusion reduced baseline total methane (CH4) from combined exhaust and open crankcase by upwards of 16%. These atmospheric emissions only decreased further with the inclusions of collected PC and compressor vent flows. The resulting changes in time-averaged rated exhaust behavior (or lack thereof) prove that the proposed M2 system could likely be deployed at sites with modern lean-burn natural gas engines as a viable option for reducing and eliminating potential GHG sources that would have otherwise been unutilized as energy sources.

03 NATURAL GAS↗

Model bias in simulating major chemical components of PM 2.5 in China

High concentrations of PM 2.5 (particulate matter with an aerodynamic diameter less than 2.5 µm) in China have caused severe visibility degradation. Accurate simulations of PM 2.5 and its chemical components are essential for evaluating the effectiveness of pollution control strategies and the health and climate impacts of air pollution. In this study, we compared the GEOS-Chem model simulations with comprehensive datasets for organic aerosol (OA), sulfate, nitrate, and ammonium in China. Model results are evaluated spatially and temporally against observations. The new OA scheme with a simplified secondary organic aerosol (SOA) parameterization significantly improves the OA simulations in polluted urban areas, highlighting the important contributions of anthropogenic SOA from semivolatile and intermediate-volatility organic compounds. The model underestimates sulfate and overestimates nitrate for most of the sites throughout the year. More significant underestimation of sulfate occurs in winter, while the overestimation of nitrate is extremely large in summer. The model is unable to capture some of the main features in the diurnal pattern of the PM 2.5 chemical components, suggesting inaccuracies in the presented processes. Potential model adjustments that may lead to a better representation of the boundary layer height, the precursor emissions, hydroxyl radical concentrations, the heterogeneous formation of sulfate and nitrate, and the wet deposition of nitric acid and nitrate have been tested in the sensitivity analysis. The results show that uncertainties in chemistry perhaps dominate the model biases. The proper implementation of heterogeneous sulfate formation and the good estimates of the concentrations of sulfur dioxide, hydroxyl radical, and aerosol liquid water are essential for the improvement of the sulfate simulation. The update of the heterogeneous uptake coefficient of nitrogen dioxide significantly reduces the modeled concentrations of nitrate. However, the large overestimation of nitrate concentrations remains in summer for all tested cases. The possible bias in the chemical production and the wet deposition of nitrate cannot fully explain the model overestimation of nitrate, suggesting issues related to the atmospheric removal of nitric acid and nitrate. A better understanding of the atmospheric nitrogen budget, in particular, the role of the photolysis of particulate nitrate, is needed for future model developments. Moreover, the results suggest that the remaining underestimation of OA in the model is associated with the underrepresented production of SOA.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Influence of pilot-fuel mixing on the spatio-temporal progression of two-stage autoignition of diesel-sprays in low-reactivity ambient fuel-air mixture

The spatial and temporal locations of autoignition for direct-injection compression-ignition engines depend on fuel chemistry, temperature, pressure, and mixing trajectories in the fuel jets. Dual-fuel systems can provide insight into both fuel-chemistry and physical effects by varying fuel reactivities and engine operating conditions. In this context, the spatial and temporal progression of two-stage autoignition of a diesel-fuel surrogate, n-heptane, in a lean-premixed charge of synthetic natural-gas (NG) and air is imaged in an optically accessible heavy-duty diesel engine. The lean-premixed charge of NG is prepared by fumigation upstream of the engine intake manifold. Optical diagnostics include high-speed (15kfps) cool-flame chemiluminescence-imaging as an indicator of low-temperature heat-release (LTHR) and OH* chemiluminescence-imaging as an indicator high-temperature heat-release (HTHR). NG prolongs the ignition delay of the pilot fuel and increases the combustion duration. Zero-dimensional chemical-kinetics simulations provide further understanding by replicating a Lagrangian perspective for mixtures evolving along streamlines originating either at the fuel nozzle or in the ambient gas, for which the pilot-fuel concentration is either decreasing or increasing, respectively. The zero-dimensional simulations predict that LTHR initiates most likely on the air streamlines before transitioning to HTHR, either on fuel-streamlines or on air-streamlines in regions of near-constant φ. Due to the relatively short pilot-fuel injection-durations, the transient increase in entrainment near the end of injection (entrainment wave) is important for quickly creating auto-ignitable mixtures. To achieve desired combustion characteristics, e.g., multiple ignition-kernels and favorable combustion phasing and location (e.g., for reducing wall heat-transfer or optimizing charge stratification), adjusting injection parameters could tailor mixing trajectories to offset changes in fuel ignition chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Learning to Simulate Aerosol Dynamics with Graph Neural Networks

Aerosol effects on climate, weather, and air quality depend on characteristics of individual particles, which are tremendously diverse and change in time. Particle-resolved models are the only models able to capture this diversity in particle physiochemical properties, and these models are computationally expensive. As a strategy for accelerating particle-resolved microphysics models, we introduce Graph-based Learning of Aerosol Dynamics (GLAD) and use this model to train a surrogate of the particle-resolved model PartMC-MOSAIC. GLAD implements a Graph Network-based Simulator (GNS), a machine learning framework that has been used to simulate particle-based fluid dynamics models. In GLAD, each particle is represented as a node in a graph, and the evolution of the particle population over time is simulated through learned message passing. Here, we demonstrate our GNS approach on a simple aerosol system that includes condensation of sulfuric acid onto particles composed of sulfate, black carbon, organic carbon, and water. A graph with particles as nodes is constructed, and a graph neural network (GNN) is then trained using the model output from PartMC-MOSAIC. The trained GNN can then be used for simulating and predicting aerosol dynamics over time. Results demonstrate the framework's ability to accurately learn chemical dynamics and generalize across different scenarios, achieving efficient training and prediction times. We evaluate the performance across four scenarios, highlighting the framework's robustness and adaptability in modeling aerosol microphysics and chemistry.

aerosol chemistry dynamics↗

Latent heat thermal energy storage performance maps enabling fast & accurate building energy simulations

Thermal energy storage (TES) using phase change materials (PCMs) has gained attention as an effective approach to manage energy demand fluctuations and shift peak building loads. PCM embedded heat exchangers (PCM-HXs) offer high energy storage density and low temperature variation during phase change, being suitable for load-shifting applications. However, this component is typically evaluated using computationally expensive methods, which present significant challenges when the ultimate goal is to assess the performance of PCM-HX integrated thermal energy storage systems in the full building context. In this paper, we present a methodology to generate highly accurate and computationally efficient PCM-HX performance maps which can be easily integrated into building energy simulation tools to analyze the feasibility of space conditioning systems with latent heat PCM-based TES. The performance maps are generated using a computationally efficient PCM-HX simulation tool based on a Generalized Resistance-Capacitance Model (GRCM) which can simulate arbitrary PCM-HXs with high accuracy and significantly less computational effort compared to full CFD simulations. The methodology was verified for a case study considering a 5-ton (~17.5 kW) air-to-water heat pump-thermal energy storage system (HP-TES), which was co-simulated in Modelica for a DOE prototype small-office building in Vienna, Austria, using Spawn of EnergyPlus™. The TES performance maps provided accurate predictions of PCM-HX behavior when used as Modelica component, with deviations within 2-4% while also achieving at least 103 computational time reduction. Leveraging this faster prediction capability, four PCMs with different melting temperatures for cooling (12°C, 16°C) and heating (31°C, 36°C) were assessed to investigate their impact on system performance. This work highlights the importance of robust PCM-HX models for efficient and high-fidelity building-level simulations, presenting new opportunities for advanced control strategy development and parametric analysis of TES configurations in a computationally efficient manner

Modelica Building Simulations↗

An analysis of the hybrid internal mass modeling approach in EnergyPlus

Accurate simulation of building system dynamics is particularly important for understanding building energy flexibility. Among all dynamics in a building, a zone temperature’s variation is especially important, as it significantly affects a building’s electricity load profile when its heating, ventilating, and air conditioning (HVAC) system is controlled with on/off cycles or setpoint reset strategies. To accurately simulate a zone temperature’s dynamics, internal mass needs to be modeled carefully. In this paper, we compare the two internal mass modeling approaches provided by EnergyPlus, i.e., internal mass object and zone air capacitance multiplier, to better understand their impacts on zone temperature simulation. Real building zone temperature dynamic data from small- and medium-sized office buildings are analyzed and compared with simulated data. In particular, we illustrate the effectiveness of a hybrid method of the two EnergyPlus modeling approaches, which yields more realistic zone temperature dynamics, especially when the zone is conditioned with heat pump systems with on/off cycling.

Chen, Zhelun↗

A Simplified Numerical Approach to Characterize the Thermal Response of a Moving Bed Solar Reactor

Abstract Concentrated solar thermochemical storage in the form of a zero-emission fuel is a promising option to produce long-duration energy storage. Solar fuel is produced using a cavity reactor that captures concentrated solar radiation from a solar field of heliostats. In this paper, heat transfer model of a tubular plug-flow reactor designed and manufactured for a solar fuel production is presented. Experimental data collected from a fixed bed tubular reactor testing are used for model comparison. The system consists of an externally heated tube with counter-current flowing gas and moving solid particles as the heated media. The proposed model simulates the dynamic behavior of temperature profiles of the tube wall, gas, and particles under various gas flowrates and residence times. The heat transfer between gas–wall, solid particle–wall, and gas–solid particle is numerically studied. The model results are compared with the results of experiments done using a 4 kW furnace with a 150 mm heating zone surrounding a horizontal alumina tube (reactor) with 50.8 mm outer diameter and thickness of 3.175 mm. Solid fixed particles of magnesium manganese oxide (MgMn2O4) with the size of 1 mm are packed within the length of 250 mm at the center of the tube length. Simulation results are assessed with respect to fixed bed experimental data for four different gas flowrates, namely, 5, 10, 15, and 20 standard liters per minute of air, and furnace temperatures in the range of 200–1200 °C. The simulation results showed good agreement with maximum steady state error that is less than 6% of those obtained from the experiments for all runs. The proposed model can be implemented as a low-order physical model for the control of temperature inside plug-flow reactors for thermochemical energy storage applications.

Engineering↗

Analysis of strategies to meet ASHRAE S241 infectious aerosol control targets by space type and region using EnergyPlus™ simulations

Professional organizations, such as ASHRAE, have recently proposed new voluntary standards for controlling infectious aerosols. Specifically, ASHRAE Standard 241 (S241) defines equivalent clean air targets for a range of space types that can be met through combinations of mitigation measures. This paper seeks to inform the selection of measures by space type and climate zone through building simulations that quantify the impacts of increased outdoor air ventilation; increasing filtration and/or adding germicidal ultraviolet (GUV) in the central heating, ventilation, and air-conditioning (HVAC) systems; or using portable air cleaners (PACs), upper room GUV, or whole room GUV approaches to increase equivalent clean air delivery. The measures are assessed individually and in practical combinations for their ability to meet S241 in four space types (offices, classrooms, dining areas, and healthcare waiting rooms) using prototype buildings modeled using EnergyPlus. The mitigation measures are compared holistically against baseline building operations using metrics for equivalent clean air, energy, and comfort. The results in this study show that single measures can meet S241 for offices with minimal impacts on energy and comfort, while either upper room GUV systems or combinations of measures such as MERV 13 HVAC filtration with PACs are needed to meet S241 for classrooms. The dining area and healthcare waiting room targets cannot be met in this study when assuming design occupancy and MS2 as the challenge agent, even when combining multiple measures together. This paper provides valuable considerations when designing measures to meet S241 for a range of spaces and scenarios.

GUV↗

OCHRE: The Object-oriented, Controllable, High-resolution Residential Energy Model for Dynamic Integration Studies

Electrification and the growth of distributed energy resources (DERs), including flexible loads, are changing the energy landscape of electric distribution systems and creating new challenges and opportunities for electric utilities. Changes in demand profiles require improvements in distribution system load models, which have not historically accounted for device controllability or impacts on customer comfort. Although building modeling research has focused on these features, there is a need to incorporate them into distribution load models that include DERs and can be used to study grid-interactive buildings. In this paper, we present the Object-oriented, Controllable, High-resolution Residential Energy (OCHRE) model. OCHRE is a controllable thermal-electric residential energy model that captures building thermal dynamics, integrates grid-dependent electrical behavior, contains models for common DERs and end-use loads, and simulates at a time resolution down to 1 minute. It includes models for space heaters, air conditioners, water heaters, electric vehicles, photovoltaics, and batteries that are externally controllable and integrated in a co-simulation framework. Using a proposed zero energy ready community in Colorado, we co-simulate a distribution grid and 498 all-electric homes with a diverse set of efficiency levels and equipment properties. We show that controllable devices can reduce peak demand within a neighborhood by up to 73% during a critical peak period without sacrificing occupant comfort. We also demonstrate the importance of modeling load diversity at a high time resolution when quantifying power and voltage fluctuations across a distribution system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

2D CFD of lean premixed hydrogen–air flame quenching under locomotive engine conditions

Hydrogen (H 2 ) is a promising fuel for reducing emissions in heavy-duty internal combustion engines (ICEs), but its low quenching distance increases the risk of flame propagation into narrow crevice regions, such as piston-liner gaps. This work uses detailed CFD simulations with finite-rate chemistry to investigate premixed H 2 –air flame quenching in a two-dimensional (2D) region consistent with the piston-liner gap of a diesel ICE. Model accuracy was assessed by comparison with experimentally measured quenching distances in an annular stepwise diverging tube (ASDT). A parametric study was conducted to assess the influence of crevice width (0.05–1.18 mm), pressure (50–150 bar), unburned gas temperature (431–573 K), and equivalence ratio ( Φ= 0.3–0.6). Results show that the critical Péclet number for flame survival is no greater than 3.25, consistent with prior literature, even under ultra-lean and high-pressure conditions (Φ ≤ 0.3, > 50 bar). Additionally, flames with Péclet numbers exceeding 6.15 exhibited front wrinkling, suggesting the onset of velocity-driven instabilities and enhanced flame robustness. These findings help define thresholds for flame quenching in confined geometries and support the safe design of H 2 fueled ICEs.

08 HYDROGEN↗

Shock interacting with a random array of stationary particles underwater

Accurately predicting the force experienced by particles within a random bed during shock traversal is a challenging problem. In this paper, particle-resolved inviscid simulations of shock propagation over randomly distributed beds are performed, with the goal of quantifying the force on individual particles. Water was considered the continuum material, and then results were compared with previous research completed in air and the differences resulting from these different mediums were examined. Simulations were conducted for four different combinations of incident Mach number and bed volume fraction with the particles remaining stationary. Additionally, time-resolved streamwise and transverse force coefficients were calculated for each particle in the bed. It was observed that while the average force coefficient was similar to that of an isolated particle, the force on individual particles was substantially different. An important observation was that the inviscid drag force on some particles remained consistently positive, but others consistently negative even long after the passage of the shock. This persistent force on the particle was attributed to the potential flow fields that result from neighbors' specific locations upstream and downstream. Similar behavior was observed in the transverse force, with particles experiencing sustained force in the same lateral direction. These persistent forces are inviscid quasisteady contributions which with the viscous counterpart will play an essential role in the particle's long-term dispersion if allowed to move in response to the force.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Discovery of Stacking Heterogeneity, Layer Buckling, and Residual Water in COF-999-NH 2 and Implications on CO 2 Capture

Covalent organic frameworks (COFs), with their modular architectures and tunable functionalities, provide a versatile platform to design sorbents for the direct capture of CO 2 from air. Here, for this work, we combined density functional theory, molecular dynamics, and grand canonical Monte Carlo simulations with experiment to understand structural factors for furthering COF-999-NH 2 ’s performance as the precursor to COF-999 for direct air CO 2 capture. Small energy differences among laterally shifted stackings suggest intrinsic stacking heterogeneity. The simulations show pronounced layer buckling coupled to extensive amine–nitrile hydrogen bonding and persistent pore water, which initiates undesired polymerization and undermines uptake. The predicted presence of water is confirmed by subsequent experiments. These insights point to a single, actionable design rule: exclude retained water by introducing hydrophobic pore environments to maximize the CO 2 capture efficiency.

adsorption↗

Model-based data center cooling controls comparative co-design

This article presents a comparative simulation-based control logic design process. It uses the Control Description Language (CDL) and the ASHRAE Guideline 36 high-performing building control sequences with the Modelica Buildings Library (MBL) to demonstrate a comparative analysis of two control designs for a data center chilled water plant. Details include a description of the closed-loop plant and control design methodology, including sizing and parameterization, base and alternative (Guideline 36) control logic with software implementation structure, and outline of the simulation experimentation process. The selected control designs are paired with comparable chilled water plant configurations. The models include a chiller, a water-side economizer, and an evaporative cooling tower. The plant provides cooling at 27ºC zone supply air temperature to a data center in Sacramento, CA. The comparative simulation results examined the impacts of a selected control logic detail, and present an example model-based design application. Overall, the simulation results showed a 25% annual and a 18% summer energy use reduction for alternative controls. This shows that simulation-based control logic design performance evaluation can improve energy efficiency and resilience aspects of system controls at large.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Machine learning based simultaneous control of air handling unit discharge air and condenser water temperatures set-point for minimized cooling energy in an office building

In this study, an artificial intelligence based real-time prediction and control model to optimize condenser water temperature and discharge air temperature (DAT) set-points in water-cooled air handling unit (AHU) system has been developed. EnergyPlus-MATLAB co-simulation has been conducted to analyze the developed model's effectiveness. Here, to develop artificial neural networks (ANN) model, embedded neural network objects in MATLAB was utilized. The developed model could decide an optimal temperature set-points based on outdoor air wet-bulb temperature to reflect the Korean climate context. As a result, the developed ANN prediction model showed the predictive performance of Cv(RMSE) of approximately 21%. Compared to the conventional fixed temperature algorithm, which fixes AHU DAT at 14°C and condenser water temperature at 32°C, the ANN based optimized control showed a 22% total cooling energy reduction. These results show that significant energy savings can be achieved by simultaneously controlling condenser water temperature and AHU DAT set-points considering Korean climatic characteristics using AI technologies such as ANN models.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analysis of single-mode Richtmyer–Meshkov instability using high-order incompressible vorticity-streamfunction and shock-capturing simulations

In this study, two- and three-dimensional simulation results obtained using a new high-order incompressible, variable-density vorticity–streamfunction (VS) method and data from previous ninth-order weighted essentially nonoscillatory (WENO) shock-capturing simulations are used to investigate the nonlinear dynamics of single-mode Richtmyer–Meshkov instability using a model of a Mach 1.3 air(acetone)/SF6 shock tube experiment. A comparison of the density fields from both simulations with the experimental images demonstrates very good agreement in the large-scale structure with both methods but differences in the small-scale structure. The WENO method captures the small-scale disordered structure observed in the experiment, while the VS method partially captures such structure and yields a strong rotating core. The perturbation amplitude growth from the simulations generally agrees well with the experiment. The simulation bubble and spike amplitudes agree well at early times. At later times, the WENO bubble amplitude is smaller than the VS amplitude and vice versa for the spike amplitude. The predictions of nonlinear single-mode instability growth models are shown to agree with the simulation amplitudes at early-to-intermediate times but underpredict the amplitudes at later times in the nonlinear regime. Visualizations of the mass fraction and enstrophy isosurfaces, velocity and vorticity fields, and baroclinic vorticity production and vortex stretching terms from the three-dimensional simulations indicate that, with the exception of the small-scale structure within the rollups, the VS and WENO results are in good agreement.

42 ENGINEERING↗

Modeling land surface processes over a mountainous rainforest in Costa Rica using CLM4.5 and CLM5

This study compares the performance of the Community Land Models (CLM4.5 and CLM5) against tower and ground measurements from a tropical montane rainforest in Costa Rica. The study site receives over 4000 mm of mean annual precipitation and has high daily levels of relative humidity. The measurement tower is equipped with eddy-covariance and vertical profile systems able to measure various micrometeorological variables, particularly in wet and complex terrain. In this work, results from point-scale simulations for both CLM4.5 and its updated version (CLM5) are compared to observed canopy flux and micrometeorological data. Both models failed to capture the effects of frequent rainfall events and mountainous topography on the variables of interest (temperatures, leaf wetness, and fluxes). Overall, CLM5 alleviates some errors in CLM4.5, but CLM5 still cannot precisely simulate a number of canopy processes for this forest. Soil, air, and canopy temperatures, as well as leaf wetness, remain too sensitive to incoming solar radiation rates despite updates to the model. As a result, daytime vapor flux and carbon flux are overestimated, and modeled temperature differences between day and night are higher than those observed. Slope effects appear in the measured average diurnal variations of surface albedo and carbon flux, but CLM5 cannot simulate these features. This study suggests that both CLMs still require further improvements concerning energy partitioning processes, such as leaf wetness process, photosynthesis model, and aerodynamic resistance model for wet and mountainous regions.