Search NASA⌕ Search

SEARCH · Search NASA

Results for “Algorithm Development and Nuclear Data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Data-driven analysis of ultrasonic pressure tube inspection data - 220

Pressure tubes are critical components of the CANDU reactors and other pressurized heavy water type reactors, as they contain the nuclear fuel and the coolant. Manufacturing flaws, as well as defects developed during the in-service operation, can lead to coolant leakage and can potentially damage the reactor. The current inspection process of these flaws is based on manually analyzing ultrasonic data received from multiple probes during planned, statutory outages. Recent advances on ultrasonic inspection tools enable the provision of high resolution data of significantly large volumes. This is highlighting the need for an efficient autonomous signal analysis process. Typically, the automation of ultrasonic inspection data analysis is approached by knowledge-based or supervised data-driven methods. This work proposes an unsupervised data-driven framework that requires no explicit rules, nor individually labeled signals. The framework follows a two-stage clustering procedure that utilizes the DBSCAN density-based clustering algorithm and aims to provide decision support for the assessment of potential defects in a robust and consistent way. Nevertheless, verified defect dimensions are essential in order to assess the results and train the framework for unseen defects. Initial results of the implementation are presented and discussed, with the method showing promise as a means of assessing ultrasonic inspection data. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Digital pile-up rejection for plutonium experiments with solution-grown stilbene

A solution-grown stilbene detector was used in several experiments with plutonium samples including plutonium oxide, mixed oxide, and plutonium metal samples. Neutrons from different reactions and plutonium isotopes are accompanied by numerous gamma rays especially by the 59-keV gamma ray of 241Am. Identifying neutrons correctly is important for nuclear nonproliferation applications and makes neutron/gamma discrimination and pile-up rejection necessary. Each experimental dataset is presented with and without pile-up filtering using a previously developed algorithm. The experiments were simulated using MCNPX-PoliMi, a Monte Carlo code designed to accurately model scintillation detector response. Collision output from MCNPX-PoliMi was processed using the specialized MPPost post-processing code to convert neutron energy depositions event-by-event into light pulses. The model was compared to experimental data after pulse-shape discrimination identified waveforms as gamma ray or neutron interactions. We show that the use of the digital pile-up rejection algorithm allows for accurate neutron counting with stilbene to within 2% even when not using lead shielding

Bourne, M. M.↗

Artificial Intelligence for Accelerating Nuclear Applications, Science, and Technology

Artificial intelligence (AI) and machine learning (ML) methods have had significant impacts in science and technology in recent years. These methods for generating models from datasets or logic-based algorithms that emulate aspects of human performance can similarly accelerate the fields of nuclear applications, science, and technology toward the IAEA goals of contributing to peace, health, and prosperity. In order to accomplish advances with AI in general and ML in particular across these fields, IAEA can play a significant role by establishing, hosting and curating centralised resources, including databases, adhering to FAIR (findable, accessible, interoperable and reusable) principles and Open Science best practices, providing stewardship of data sharing, supporting training efforts and development of relevant workforces, as well as enabling connections among the scientific, technology, mathematics, AI and ethics communities. Many areas can benefit from the use of AI in the realm of nuclear applications. In human health, these areas include clinical research, epidemiology, nutrition, medical imaging, radiotherapy and education of health professionals. AI-based tools are also being used to facilitate different clinical tasks in imaging, computer-assisted diagnosis in mammography and lung cancer screening programmes, and dose prediction in nuclear medicine procedures. ML methods in particular may also increase the efficiency and accuracy of the analysis of computerised tomography and dual-energy absorptiometry scans for body composition and bone analysis. The application of AI methods to nuclear and related technologies in food and agriculture can lead to significant advances and improved efficiency in the optimisation of agricultural production, food product development, management of supply chains, food safety and food authenticity control. In the water and environmental sector, AI can help inform policies to mitigate the world’s water problems. The application of AI techniques to hydrology and environmental sciences is expected to improve patterns identification and enable model predictions under a changing climate.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

DEVELOPMENT OF DECISION MAKING ALGORITHM FOR CONTROL OF SEA CARGO CONTAINERS BY 'TAGGED' NEUTRON METHOD

Nowadays in Russia and abroad there are several groups of scientists, engaged in development of systems based on 'tagged' neutron method (API method) and intended for detection of dangerous materials, including high explosives (HE). Particular attention is paid to possibility of detection of dangerous objects inside a sea cargo container. Energy gamma-spectrum, registered from object under inspection is used for determination of oxygen/carbon and nitrogen/carbon chemical ratios, according to which dangerous object is distinguished from not dangerous one. Material of filled container, however, gives rise to additional effects of rescattering and moderation of 14 MeV primary neutrons of generator, attenuation of secondary gamma-radiation from reactions of inelastic neutron scattering on objects under inspection. These effects lead to distortion of energy gamma-response from examined object and therefore prevent correct recognition of chemical ratios. These difficulties are taken into account in analytical method, presented in the paper. Method has been validated against experimental data, obtained by the system for HE detection in sea cargo, based on API method and developed in VNIIA. Influence of shielding materials on results of HE detection and identification is considered. Wood and iron were used as shielding materials. Results of method application for analysis of experimental data on HE simulator measurement (tetryl, trotyl, hexogen) are presented.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Progress on a High Sensitivity, High Purity, One-Electron-One-Proton Search for the MiniBooNE Low Energy Excess in the MicroBooNE Detector

MicroBooNE is a large liquid argon time projection chamber (LArTPC) located at Fermilab. One of the experiments primary aims is to investigate the CCQE-like excess of ν ϵ events observed by MiniBooNE at low energy. A novel approach to analyzing LArTPC data using an amalgam of Deep Learning and traditional algorithms has been developed and is capable of end to end reconstruction and selection. We report here an overview and progress to event selection which yields greater than 99.999% rejection of backgrounds. Statistical, flux, and some cross section systematics have also been evaluated. Detector systematics and additional cross section systematics are still under study.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A BPF-FBP tandem algorithm for image reconstruction in reverse helical cone-beam CT

Purpose: Reverse helical cone-beam computed tomography (CBCT) is a scanning configuration for potential applications in image-guided radiation therapy in which an accurate anatomic image of the patient is needed for image-guidance procedures. The authors previously developed an algorithm for image reconstruction from nontruncated data of an object that is completely within the reverse helix. The purpose of this work is to develop an image reconstruction approach for reverse helical CBCT of a long object that extends out of the reverse helix and therefore constitutes data truncation. Methods: The proposed approach comprises of two reconstruction steps. In the first step, a chord-based backprojection-filtration (BPF) algorithm reconstructs a volumetric image of an object from the original cone-beam data. Because there exists a chordless region in the middle of the reverse helix, the image obtained in the first step contains an unreconstructed central-gap region. In the second step, the gap region is reconstructed by use of a Pack-Noo-formula-based filteredbackprojection (FBP) algorithm from the modified cone-beam data obtained by subtracting from the original cone-beam data the reprojection of the image reconstructed in the first step. Results: The authors have performed numerical studies to validate the proposed approach in image reconstruction from reverse helical cone-beam data. The results confirm that the proposed approach can reconstruct accurate images of a long object without suffering from data-truncation artifacts or cone-angle artifacts. Conclusions: They developed and validated a BPF-FBP tandem algorithm to reconstruct images of a long object from reverse helical cone-beam data. The chord-based BPF algorithm was utilized for converting the long-object problem into a short-object problem. The proposed approach is applicable to other scanning configurations such as reduced circular sinusoidal trajectories.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Detection of reflected Cherenkov light from extensive air showers in the SPHERE experiment as a method of studying superhigh energy cosmic rays

Although a large number of experiments were carried out during the last few decades, the uncertainty in the spectrum of all nuclei of primary cosmic rays (PCRs) with superhigh energies is still high, and the results of many experiments on nuclear composition of PCRs are contradictory. An overview of the SPHERE experiment on detecting Vavilov-Cherenkov radiation from extensive air shower (EAS) reflected from a ground snow surface is given. A number of experimental studies implementing this method are presented and their results are analyzed. Some other popular methods of studying PCRs with superhigh energies (E{sub 0} > 10{sup 15} eV) and their main advantages and drawbacks are briefly considered. The detecting equipment of the SPHERE-2 experiment and the technique of its calibration are considered. The optical properties of snow, which are important for experiments on reflected Cherenkov light (CL) from EAS, are discussed and the history of observing reflected EAS CL is described. The algorithm of simulating the detector response and calculating the fiducial acceptance of shower detection is described. The procedure of processing the experimental data with a subsequent reconstruction of the spectrum of all PCR nuclei and analysis of the mass composition is shown. The first results of reconstructing the spectrum and separating groups of cosmic-ray nuclei with high energies in the SPHERE-2 experiment are presented. Main sources of systematic errors are considered. The prospects of developing the technique of observation of reflected EAS CL in future experiments are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Decoding {beta}-decay systematics: A global statistical model for {beta}{sup -} half-lives

Statistical modeling of nuclear data provides a novel approach to nuclear systematics complementary to established theoretical and phenomenological approaches based on quantum theory. Continuing previous studies in which global statistical modeling is pursued within the general framework of machine learning theory, we implement advances in training algorithms designed to improve generalization, in application to the problem of reproducing and predicting the half-lives of nuclear ground states that decay 100% by the {beta}{sup -} mode. More specifically, fully connected, multilayer feed-forward artificial neural network models are developed using the Levenberg-Marquardt optimization algorithm together with Bayesian regularization and cross-validation. The predictive performance of models emerging from extensive computer experiments is compared with that of traditional microscopic and phenomenological models as well as with the performance of other learning systems, including earlier neural network models as well as the support vector machines recently applied to the same problem. In discussing the results, emphasis is placed on predictions for nuclei that are far from the stability line, and especially those involved in r-process nucleosynthesis. It is found that the new statistical models can match or even surpass the predictive performance of conventional models for {beta}-decay systematics and accordingly should provide a valuable additional tool for exploring the expanding nuclear landscape.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Performance Validation of Pulsed Thermal Imaging System for In-Service Applications

Additive manufacturing (AM) is an emerging method for cost-efficient fabrication of complex topology nuclear reactor parts from high-strength corrosion resistance alloys, such as stainless steel and Inconel. AM of metallic structures for nuclear energy applications is currently based on laser powder bed fusion (LPBF) process, which has the capability of melting metallic powder and net shaping the structures with relatively high precision. Some of the challenges with using LPBF method for nuclear manufacturing include the possibility of introducing pores into metallic structures. Integrity of AM structures needs to be evaluated nondestructively because material flaws could lead to premature failures in high temperature nuclear reactor environment. Currently, there exist limited capabilities to evaluate actual AM structures non-destructively. Pulsed Thermography Imaging (PTI) provides a capability for non-destructive evaluation (NDE) of subsurface defects in arbitrary size structures. The PTI method is based on recording material surface temperature transients with infrared (IR) camera following thermal pulse delivered on material surface with flash light. The PTI method has advantages for NDE of actual AM structures because the method involves one-sided non-contact measurements and fast processing of large sample areas captured in one image. Following initial qualification of an AM component for deployment in a nuclear reactor, a PTI system can also be used for in-service nondestructive evaluation (NDE) applications. In this report, we describe recent progress in enhancing PTI capabilities in detecting microscopic defects in metallic specimens. SS316 and IN718 specimens were developed with a pattern of subsurface calibrated flat bottom hole (FBH) defects with diameters from 500µm to 200µm. FBH’s were created with EDM (electron discharge machining) drill. PTI imaging data was processed Spatial Temporal Denoised Thermal Source Separation (STDTSS) unsupervised machine learning (ML) algorithm. We show that defects as small as 200µm in SS316 and IN718 can be detected with STDTSS algorithm. To the best of our knowledge, these are the smallest detected defects which are reported in literature.

42 ENGINEERING↗

CBRN Situational Awareness Tools for the Modern Age

CBRN Situational awareness (SA) should be a key operational requirement in the CNI area of discussion, not only for the “boots-on-the-ground” warfighter, but at a strategic level. For example, maneuver plans will need to be developed for contamination avoidance and battlefield survivability. Large datasets from instruments dispersed across the battlefield will thus need to be collected and processed into a holistic assessment of the radiological hazard. From there, hazard maps then must be distributed at the tactical level, all while continuing to effectively engage a peer adversary. This vision represents a network of sensors, software tools, data processing algorithms, communications suites, and common operational picture (COP) platforms working in concert to inform warfighters and command echelons alike of evolving nuclear and radiological hazards. This complex system-of-systems and the ultimate goal of effective engagement in a nuclear or radiological-hazard battlefield can be achieved through pursuit of improvement in collaborative SA tools.

Becker, Eric M.↗

Inspection design using 2D phased array, TFM and cueMAP software

A simulation suite, cueMAP, has been developed to facilitate the design of inspection processes and sparse 2D array configurations. At the core of cueMAP is a Total Focusing Method (TFM) imaging algorithm that enables computer assisted design of ultrasonic inspection scenarios, including the design of bespoke array configurations to match the inspection criteria. This in-house developed TFM code allows for interactive evaluation of image quality indicators of ultrasonic imaging performance when utilizing a 2D phased array working in FMC/TFM mode. The cueMAP software uses a series of TFM images to build a map of resolution, contrast and sensitivity of imaging performance of a simulated reflector, swept across the inspection volume. The software takes into account probe properties, wedge or water standoff, and effects of specimen curvature. In the validation process of this new software package, two 2D arrays have been evaluated on 304n stainless steel samples, typical of the primary circuit in nuclear plants. Thick section samples have been inspected using a 1MHz 2D matrix array. Due to the processing efficiency of the software, the data collected from these array configurations has been used to investigate the influence sub-aperture operation on inspection performance.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Broadly Applicable Dose Model for Radiotherapy Beams from 6-25 MV

The goal of modern external beam radiotherapy is to deliver a highly targeted radiation dose to a specified treatment volume while sparing the healthy surrounding tissue as much as possible. However, some healthy tissue radiation exposure is unavoidable. Healthy tissue in the margin of the treatment field will receive absorbed doses on the order of the prescribed dose, and tissue far out of field will receive stray dose from scattered and leakage radiation. These doses can lead to late effects such as secondary cancers both near the treatment field and far out of field in tissues only receiving stray radiation dose. Many researchers have investigated algorithms to model absorbed dose from external beam photon radiation therapy; however, none of these works have fully addressed the stray dose far from the treatment field. The AAPM Task Group Report No. 36 described three main sources of stray radiation from external beam radiation therapy delivered with electron linear accelerators. Radiation scattered from the treatment head, known as head scatter, is primarily important within about 10 cm from the field edge. Patient scatter is an important source up to around 30 cm from the field edge. Finally, leakage radiation emanates from the treatment enclosure and predominates the stray radiation dose beyond about 30 cm. Monte Carlo simulations have been a useful research tool for modeling stray dose, but these methods have not found use in clinical settings due to their complexity and long computational times. The feasibility of analytical models to predict stray dose from radiation therapy has been supported by several works, but few attempts have been made at developing models accurate for both in-field and out-of-field doses. Jagetic and Newhauser reported on one such model that predicts absorbed dose from therapeutic, scatter, and leakage radiation with promising results. This model was validated at 6 MV for Conformal Radiation Therapy (CRT) beams from an Elekta linac. Intensity Modulated Radiation Therapy (IMRT) was not considered, and the model has not been tested at beam energies greater than 6 MV. Additionally, this model relies on proprietary, machine specific parameters, and so adapting the model for use on treatment units from other manufacturers is not straightforward. In this study we aim to test whether a physics-based analytical modeling approach is broadly applicable and if sufficient accuracy can be achieved without the need for proprietary, machine specific parameters. In order to accomplish this, a new analytical model was developed that does not rely on machine specific parameters, so that it can easily be trained on measurements from whatever treatment machine is available at a given clinic. This model was tested using measured data from a variety of treatment machines and techniques in the 6 MV to 25 MV energy interval. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Pattern ANalytics To Support High-performance Exploitation and Reasoning (PANTHER)

Sandia researchers are developing analytic techniques that efficiently detect patterns in high-volume, noisy, remote sensing and other geospatial data, improving an analysts’ ability to detect possibly off-normal events in complex homeland security, nuclear weapons, and emerging threat environments. High-consequence, national security decisions rely on timely, comprehensive answers to complex questions, yet critical gaps in our approach to these questions remain. PANTHER addresses these gaps through fundamental research on: geospatial-temporal feature extraction via image segmentation and classification; geospatial-temporal graph algorithms and computational geometry; and domain-relevant models of human perception and cognition informing the design of analytic systems. PANTHER’s cross-disciplinary R&D approach uses fundamental science and mathematics to understand how to maximize decision systems through rethinking key aspects of geospatial data analysis. New methods in motion and trajectory analysis support both rapid search for known trajectories as well as rapid clustering and anomaly detection. Thus, the perceptual and visual load on users is reduced by providing pattern analytics with elegant visual cues to spatial and temporal characteristics.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Development and application of marginal likelihood optimization for integral parameter adjustment

When adjusting nuclear data with integral experiments, care must be taken that spurious adjustments are not made by assimilating poorly characterized integral parameters. If there are unaccounted for biases or poorly estimated uncertainties in the calculated and experimental values for an integral parameter, the Bayesian data assimilation may adjust the nuclear data in a manner that does not reflect the physics of the integral parameter. To identify and lessen the impact of these inconsistent integral parameters, in this study we present a Marginal Likelihood Optimization algorithm. In a data-driven way, the marginalized likelihood is used to modulate hyperparameter terms that decrease the influence of inconsistent integral parameters on the adjustment. The advantage of this approach over other methods in the literature is that it incorporates correlation information and does not remove an integral parameter from the adjustment. Herein, we present and motivate the algorithm, and apply it to an integral data assimilation case study.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Robust Online Monitoring for Calibration Assessment of Transmitters and Instrumentation

Robust online monitoring (OLM) technologies are expected to enable the extension or elimination of periodic sensor calibration intervals in operating and new reactors. These advances in OLM technologies will improve the safety and reliability of current and planned nuclear power systems through improved accuracy and increased reliability of sensors used to monitor key parameters. In this article, we discuss an overview of research being performed within the Nuclear Energy Enabling Technologies (NEET)/Advanced Sensors and Instrumentation (ASI) program, for the development of OLM algorithms to use sensor outputs and, in combination with other available information, 1) determine whether one or more sensors are out of calibration or failing and 2) replace a failing sensor with reliable, accurate sensor outputs. Algorithm development is focused on the following OLM functions: • Signal validation • Virtual sensing • Sensor response-time assessment These algorithms incorporate, at their base, a Gaussian Process-based uncertainty quantification (UQ) method. Various plant models (using kernel regression, GP, or hierarchical models) may be used to predict sensor responses under various plant conditions. These predicted responses can then be applied in fault detection (sensor output and response time) and in computing the correct value (virtual sensing) of a failing physical sensor. The methods being evaluated in this work can compute confidence levels along with the predicted sensor responses, and as a result, may have the potential for compensating for sensor drift in real-time (online recalibration). Evaluation was conducted using data from multiple sources (laboratory flow loops and plant data). Ongoing research in this project is focused on further evaluation of the algorithms, optimization for accuracy and computational efficiency, and integration into a suite of tools for robust OLM that are applicable to monitoring sensor calibration state in nuclear power plants.

fault detection↗

Temporal resolution and motion artifacts in single-source and dual-source cardiac CT

Purpose: The temporal resolution of a given image in cardiac computed tomography (CT) has so far mostly been determined from the amount of CT data employed for the reconstruction of that image. The purpose of this paper is to examine the applicability of such measures to the newly introduced modality of dual-source CT as well as to methods aiming to provide improved temporal resolution by means of an advanced image reconstruction algorithm. Methods: To provide a solid base for the examinations described in this paper, an extensive review of temporal resolution in conventional single-source CT is given first. Two different measures for assessing temporal resolution with respect to the amount of data involved are introduced, namely, either taking the full width at half maximum of the respective data weighting function (FWHM-TR) or the total width of the weighting function (total TR) as a base of the assessment. Image reconstruction using both a direct fan-beam filtered backprojection with Parker weighting as well as using a parallel-beam rebinning step are considered. The theory of assessing temporal resolution by means of the data involved is then extended to dual-source CT. Finally, three different advanced iterative reconstruction methods that all use the same input data are compared with respect to the resulting motion artifact level. For brevity and simplicity, the examinations are limited to two-dimensional data acquisition and reconstruction. However, all results and conclusions presented in this paper are also directly applicable to both circular and helical cone-beam CT. Results: While the concept of total TR can directly be applied to dual-source CT, the definition of the FWHM of a weighting function needs to be slightly extended to be applicable to this modality. The three different advanced iterative reconstruction methods examined in this paper result in significantly different images with respect to their motion artifact level, despite exactly the same amount of data being used in the reconstruction process. Conclusions: The concept of assessing temporal resolution by means of the data employed for reconstruction can nicely be extended from single-source to dual-source CT. However, for advanced (possibly nonlinear iterative) reconstruction algorithms the examined approach fails to deliver accurate results. New methods and measures to assess the temporal resolution of CT images need to be developed to be able to accurately compare the performance of such algorithms.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Dark Energy Survey Data Management System

The Dark Energy Survey (DES) is a project with the goal of building, installing and exploiting a new 74 CCD-camera at the Blanco telescope, in order to study the nature of cosmic acceleration. It will cover 5000 square degrees of the southern hemisphere sky and will record the positions and shapes of 300 million galaxies up to redshift 1.4. The survey will be completed using 525 nights during a 5-year period starting in 2012. About O(1 TB) of raw data will be produced every night, including science and calibration images. The DES data management system has been designed for the processing, calibration and archiving of these data. It is being developed by collaborating DES institutions, led by NCSA. In this contribution, we describe the basic functions of the system, what kind of scientific codes are involved and how the Data Challenge process works, to improve simultaneously the Data Management system algorithms and the Science Working Group analysis codes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multiphysics for nuclear energy applications using a cohesive computational framework

With the recent development of advanced numerical algorithms, software design, and low-cost high-performance computer hardware, reliance on coupled multiphysics to predict the behavior of complex physical systems is beginning to become standard practice. This is especially true in nuclear energy applications where strong nonlinear interdependencies exist between reactor physics, radiation transport, multi-scale nuclear fuels performance, thermal fluids, etc. Resolving these nonlinear dependencies requires choices in multiphysics software approaches. Two main multiphysics modeling and simulation approaches have emerged. The first is based upon "code coupling" where disparate physics codes of different software design, code languages, and spatial and temporal integration schemes are coupled together with relatively complex data passing interfaces. The second multiphysics software approach is to employ a "cohesive" framework where all physics applications are developed with a common software design, i.e., data structures, syntax, input format, integrated spatial and temporal discretization schemes, etc. In this paper we present the Multiphysics Object-Oriented Simulation Environment (MOOSE) development and runtime framework and describe the framework's cohesive modeling and simulation multiphysics approach. Then, a "cohesive-like" extension of the MOOSE framework is presented where MOOSE-based physics software applications are efficiently coupled to non-MOOSE (external) physics codes to form multiphysics applications using MOOSE's unique interface capabilities. Finally, several examples of MOOSE's cohesive and cohesive-like multiphysics applications will be demonstrated. These multiphysics demonstrations will incorporate both MOOSE-based applications and external codes, including Nek5000, RELAP-7, TRACE, BISON, and Pronghorn.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗