Search NASA⌕ Search

SEARCH · Search NASA

Results for “Analyzer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

The CMS Phase 2 Outer Tracker Analyzer of Test Outputs - POTATO!

The Phase-2 upgrade of the Large Hadron Collider (LHC), also known as the High-Luminosity LHC (HL-LHC) is designed to achieve peak instantaneous luminosities which is about an order of magnitude higher than the nominal design value of $10^{34}~cm^{-2}s^{-1}$ delivering a total of atleast $3000 fb^{-1}$ data over 10 years of operation at $\sqrt{s}~=~14~TeV$. One crucial aspect of the CMS Phase-2 detector upgrade is the replacement of the existing tracking detector in order to deal with the extreme HL-LHC conditions, retaining and further expanding the physics performances achieved in the previous years. The outer part of the upgraded tracker (OT), will be equipped with over 13,000 macro Pixel-Strip (PS) and Strip-Strip (2S) modules! Module production is distributed across centers worldwide and necessitates coordinated efforts and standardized procedures. Along with production and assembly of the modules, Fermilab OT group is also working on a tool, Phase 2 Outer Tracker Analyzer of Test Outputs (POTATO) that will analyze, grade, upload and manage the large quantity of files to be stored in the centralized Database (DB). In this contribution a brief overview of the module testing and the power and dire need of POTATO to handle this large number of test outputs will be presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analyzing Risks of Virtual Private Network Connections

The use of Splunk for analyzing VPN logs is an effective approach for identifying vulnerabilities in network endpoints. Splunk, a powerful platform for searching, monitoring, and analyzing machine-generated data, enables organizations to aggregate VPN logs in real-time, providing insights into network activity, user behavior, and potential security risks. By indexing VPN traffic and authentication logs, security teams can track abnormal patterns such as multiple failed login attempts, unusual IP addresses, or unexpected changes in bandwidth usage, all of which could indicate potential vulnerabilities or breaches. With Splunk’s advanced search and reporting capabilities, users can create custom dashboards and alerts to detect suspicious activities. Automated searches can flag endpoints exhibiting unusual behavior, while correlation analysis can identify links between compromised devices and broader network vulnerabilities. In particular, Splunk's machine learning capabilities can be leveraged to predict and prevent threats by identifying trends that might otherwise be missed in traditional log analysis. This proactive approach to monitoring VPN logs allows for the early detection of security weaknesses, enabling rapid response and minimizing potential damage to network integrity. By enhancing endpoint visibility, Splunk plays a crucial role in securing remote connections and safeguarding sensitive information. Additionally, Splunk’s automation and alerting features allow teams to create custom workflows that notify them of vulnerable or misconfigured endpoints identified through Shodan. This synergy between Splunk’s log analysis and Shodan’s device intelligence enhances an organization’s ability to proactively identify and mitigate security risks, improving the overall resilience of their VPN infrastructure.

97 MATHEMATICS AND COMPUTING↗

A novel flow cell for optical particle analyzers—application to measurements of Malvern Insitec under high pressure and temperature

A flow cell is a necessary measurement interface for some important optical analyzers. In our application of the flow cell, we utilize a state-of-the-art optical analyzer (Malvern Insitec) to measure particle size distribution and concentration in-situ in a sampled flow from a novel pressurized oxygen-fuel combustion process. However, since this sampling flow is a flow of moist flue gas under high temperature and pressure, and the flow contains particles and corrosive acid gases, it is an extreme challenge to obtain a flow cell with a high optical quality that does not perturb the measurement. To address this challenge, we propose a new design for an optical flow cell. By using a unique flow field in the proposed flow cell, the measurement zone can be well defined by the sampling flow, minimizing the influence of purge flow. To demonstrate this flow cell, we have built a test system, and conduct measurements utilizing polydisperse-particle standards (10-100 µm and 1-10 µm). The results reveal that the optical windows are well protected by the purge flow field, without risk of deposition from the sampling flow, and the Malvern Insitec can measure the particle size distribution by using this flow cell, without generating sample bias.

Cheng, Mao↗

Characterization of the Sunset Semi-Continuous Carbon Aerosol Analyzer

Accurate quantification of carbonaceous aerosols is essential for reducing uncertainty in climate change models and is important for long-term air quality monitoring by government agencies. The field-deployable Sunset Semi-Continuous Organic Carbon/Elemental Carbon Aerosol Analyzer (Sunset OCEC) utilizes a modified National Institute for Occupational Safety and Health thermal-optical method to determine total carbon (TC), organic carbon (OC), and elemental carbon (EC) at near real-time; however, its performance is not yet fully characterized. Two collocated Sunset OCEC Analyzers, Unit A and Unit B, were used to determine the relative standard deviation (RSD) and limit of detection (LOD) between June 23 and July 9, 2007, in Richland, Washington, USA. A high-efficiency particulate air filter was utilized to determine the LODs of both instruments. The RSDs between the two Sunset OCECs were 9.12% for TC, 13.0% for Optical OC, and 8.97% for Thermal OC, indicating good precision between the instruments, although the RSDs for Thermal and Optical EC were higher, 29.0% and 48.3%, respectively. The LOD of Unit A was approximately 0.21 µgC/m3 for TC, Optical OC, and Thermal OC, and ~0.004 µgC/m3 for Optical and Thermal EC. Similarly, Unit B had an LOD of ~0.29 µgC/m3 for TC, Optical OC, and Thermal OC, 0.018 µgC/m3 for Optical EC, and 0.004 µgC/m3 for Thermal EC. Factors that may have contributed to the poor RSDs of Thermal and Optical EC include the low EC mass loading in Richland, minor leakage in the oxygen valve of Unit B, and excessive noise from the non-dispersive infrared (NDIR) laser in Unit B, resulting in scattered Optical EC measurements. Improved RSDs of all OC and EC parameters are expected after the Unit B NDIR is tuned up. Future work should reevaluate the precision of the Sunset OCECs and investigate the differences in various thermal-optical protocols on OCEC quantification.

54 ENVIRONMENTAL SCIENCES↗

Analyzing Impact of Distributed PV Generation on Integrated Transmission & Distribution System Voltage Stability—A Graph Trace Analysis Based Approach

The use of a Graph Trace Analysis (GTA)-based power flow for analyzing the voltage stability of integrated Transmission and Distribution (T&D) networks is discussed in the context of distributed Photovoltaic (PV) generation. The voltage stability of lines and the load carrying capability of buses is analyzed at various PV penetration levels. It is shown that as the PV generation levels increase, an increase in the steady state voltage stability of the system is observed. Moreover, within certain regions of stability margin changes, changes in voltage stability margins of transmission lines are shown to be linearly related to changes in the loading of the lines. Two case studies are presented, where one case study involves a model with eight voltage levels and 784,000 nodes. In one case study, a voltage-stability heat map is used to demonstrate the identification of weak lines and buses.

14 SOLAR ENERGY↗

Analyzing and Comparing Biomass Feedstock Supply Systems in China: Corn Stover and Sweet Sorghum Case Studies

This paper analyzes the rural Chinese biomass supply system and models supply chain operations according to U.S. concepts of logistical unit operations: harvest and collection, storage, transportation, preprocessing, and handling and queuing. In this paper, we quantify the logistics cost of corn stover and sweet sorghum in China under different scenarios. We analyze three scenarios of corn stover logistics from northeast China and three scenarios of sweet sorghum stalks logistics from Inner Mongolia in China. The case study estimates that the logistics cost of corn stover and sweet sorghum stalk to be $52.95/dry metric ton and $52.64/dry metric ton, respectively, for the current labor-based biomass logistics system. However, if the feedstock logistics operation is mechanized, the cost of corn stover and sweet sorghum stalk decreases to $36.01/dry metric ton and $35.76/dry metric ton, respectively. The study also includes a sensitivity analysis to identify the cost factors that cause logistics cost variation. Results of the sensitivity analysis show that labor price has the most influence on the logistics cost of corn stover and sweet sorghum stalk, with a variation of $6 to $12/dry metric ton.

09 BIOMASS FUELS↗

ANALYZING THE LARGEST SPECTROSCOPIC DATA SET OF STRIPPED SUPERNOVAE TO IMPROVE THEIR IDENTIFICATIONS AND CONSTRAIN THEIR PROGENITORS

Using the largest spectroscopic data set of stripped-envelope core-collapse supernovae (stripped SNe), we present a systematic investigation of spectral properties of Type IIb SNe (SNe IIb), Type Ib SNe (SNe Ib), and Type Ic SNe (SNe Ic). Prior studies have been based on individual objects or small samples. Here, we analyze 242 spectra of 14 SNe IIb, 262 spectra of 21 SNe Ib, and 207 spectra of 17 SNe Ic based on the stripped SN data set of Modjaz et al. and other published spectra of individual SNe. Each SN in our sample has a secure spectroscopic ID, a date of V -band maximum light, and most have multiple spectra at different phases. We analyze these spectra as a function of subtype and phase in order to improve the SN identification scheme and constrain the progenitors of different kinds of stripped SNe. By comparing spectra of SNe IIb with those of SNe Ib, we find that the strength of H α can be used to quantitatively differentiate between these two subtypes at all epochs. Moreover, we find a continuum in observational properties between SNe IIb and Ib. We address the question of hidden He in SNe Ic by comparing our observations with predictions from various models that either include hidden He or in which He has been burnt. Our results favor the He-free progenitor models for SNe Ic. Finally, we construct continuum-divided average spectra as a function of subtype and phase to quantify the spectral diversity of the different types of stripped SNe.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimization of an enclosed gas analyzer sampling system for measuring eddy covariance fluxes of H 2 O and CO 2

Several initiatives are currently emerging to observe the exchange of energy and matter between the earth's surface and atmosphere standardized over larger space and time domains. For example, the National Ecological Observatory Network (NEON) and the Integrated Carbon Observing System (ICOS) are set to provide the ability of unbiased ecological inference across ecoclimatic zones and decades by deploying highly scalable and robust instruments and data processing. In the construction of these observatories, enclosed infrared gas analyzers are widely employed for eddy covariance applications. While these sensors represent a substantial improvement compared to their open- and closed-path predecessors, remaining high-frequency attenuation varies with site properties and gas sampling systems, and requires correction. Here, we show that components of the gas sampling system can substantially contribute to such high-frequency attenuation, but their effects can be significantly reduced by careful system design. From laboratory tests we determine the frequency at which signal attenuation reaches 50 % for individual parts of the gas sampling system. For different models of rain caps and particulate filters, this frequency falls into ranges of 2.5–16.5 Hz for CO 2 , 2.4–14.3 Hz for H 2 O, and 8.3–21.8 Hz for CO 2 , 1.4–19.9 Hz for H 2 O, respectively. A short and thin stainless steel intake tube was found to not limit frequency response, with 50 % attenuation occurring at frequencies well above 10 Hz for both H 2 O and CO 2 . From field tests we found that heating the intake tube and particulate filter continuously with 4 W was effective, and reduced the occurrence of problematic relative humidity levels (RH > 60 %) by 50 % in the infrared gas analyzer cell. No further improvement of H 2 O frequency response was found for heating in excess of 4 W. These laboratory and field tests were reconciled using resistor–capacitor theory, and NEON's final gas sampling system was developed on this basis. The design consists of the stainless steel intake tube, a pleated mesh particulate filter and a low-volume rain cap in combination with 4 W of heating and insulation. In comparison to the original design, this reduced the high-frequency attenuation for H 2 O by ≈ 3/4, and the remaining cospectral correction did not exceed 3 %, even at high relative humidity (95 %). The standardized design can be used across a wide range of ecoclimates and site layouts, and maximizes practicability due to minimal flow resistance and maintenance needs. Lastly, due to minimal high-frequency spectral loss, it supports the routine application of adaptive correction procedures, and enables largely automated data processing across sites.

54 ENVIRONMENTAL SCIENCES↗

The quasi-equilibrium framework revisited: analyzing long-term CO 2 enrichment responses in plant–soil models

Abstract. Elevated carbon dioxide ( CO 2 ) can increase plant growth, but themagnitude of this CO 2 fertilization effect is modified by soilnutrient availability. Predicting how nutrient availability affects plantresponses to elevated CO 2 is a key consideration for ecosystemmodels, and many modeling groups have moved to, or are moving towards,incorporating nutrient limitation in their models. The choice of assumptionsto represent nutrient cycling processes has a major impact on modelpredictions, but it can be difficult to attribute outcomes to specificassumptions in complex ecosystem simulation models. Here we revisit thequasi-equilibrium analytical framework introduced by Comins andMcMurtrie (1993) and explore the consequences of specific model assumptionsfor ecosystem net primary productivity (NPP). We review the literature applying this framework to plant–soilmodels and then analyze the effect of several new assumptions on predictedplant responses to elevated CO 2 . Examination of alternativeassumptions for plant nitrogen uptake showed that a linear function of themineral nitrogen pool or a linear function of the mineral nitrogen pool withan additional saturating function of root biomass yield similar CO 2 responses at longer timescales ( >5 years), suggesting that the addedcomplexity may not be needed when these are the timescales of interest. Incontrast, a saturating function of the mineral nitrogen pool with lineardependency on root biomass yields no soil nutrient feedback on thevery-long-term ( >500 years), near-equilibrium timescale, meaning that oneshould expect the model to predict a full CO 2 fertilization effecton production. Secondly, we show that incorporating a priming effect on slowsoil organic matter decomposition attenuates the nutrient feedback effect onproduction, leading to a strong medium-term (5–50 years) CO 2 response. Models incorporating this priming effect should thus predict astrong and persistent CO 2 fertilization effect over time. Thirdly,we demonstrate that using a “potential NPP” approach to represent nutrientlimitation of growth yields a relatively small CO 2 fertilizationeffect across all timescales. Overall, our results highlight thefact that the quasi-equilibriumanalytical framework is effective for evaluating both the consequences andmechanisms through which different model assumptions affect predictions. Tohelp constrain predictions of the future terrestrial carbon sink, werecommend the use of this framework to analyze likely outcomes of new modelassumptions before introducing them to complex model structures.

58 GEOSCIENCES↗

Welder analyzer

Welder analyzer circuit evaluates and certifies resistance welding machines. The analyzer measures peak current, peak voltage, peak power, total energy, and first-pulse energy. It is used as an energy monitor while welding is being performed, or a precision shunt load for a pure electrical evaluation of the weld machine.

Miller, L. L.↗

To develop a spectral analyzer for physiological and medical use

Scientific requirements necessary to develop a spectral analyzer for monitoring mammalian subjects, are discussed. The analyzer measures dynamic or time dependent data as a measure of the subjects operating status. Measurable data include metabolic rate, body temperature, and blood constituents like glucose, oxygen, and carbon dioxide, and lactic acid. Metabolic cycles were found with periodicities in the range of minutes and hours; longer cycles in body weight (3 1/2 days and 60 days), indicative of metabolic processes, were also found.

Iberall, A.↗

Methods of analyzing microsize particulate aerosols and contaminants.

Methods for analyzing atmospheric aerosols and particulate contaminants from natural and industrial sources are briefly described. Their development was spurred by interest in cosmic dust investigations. These methods make it possible to analyze individual particles ranging in size from 0.01 to 1000 microns for elemental and mineralogical content. The described methods include transmission electron microscopy, scanning electron microscopy, electron probe microanalysis, X-ray diffraction, optical mineralogy, and density measurement.

Blanchard, M. B.↗

A quadratic pulse height analyzer for space applications.

A flight-worthy pulse height analyzer that has a quadratic transfer function is described. This quadratic function permits optimum usage of the entire PHA dynamic range due to the quadratic nature of the gamma ray spectrometer's resolution vs energy. After the theoretical design discussion, the implementation of the design is examined and test results described. The analyzer is part of the University of New Hampshire gamma ray monitor for OSO-H.

Burtis, D. W.↗

Modular thermal analyzer routine, volume 1

The Modular Thermal Analyzer Routine (MOTAR) is a general thermal analysis routine with strong capabilities for performing thermal analysis of systems containing flowing fluids, fluid system controls (valves, heat exchangers, etc.), life support systems, and thermal radiation situations. Its modular organization permits the analysis of a very wide range of thermal problems for simple problems containing a few conduction nodes to those containing complicated flow and radiation analysis with each problem type being analyzed with peak computational efficiency and maximum ease of use. The organization and programming methods applied to MOTAR achieved a high degree of computer utilization efficiency in terms of computer execution time and storage space required for a given problem. The computer time required to perform a given problem on MOTAR is approximately 40 to 50 percent that required for the currently existing widely used routines. The computer storage requirement for MOTAR is approximately 25 percent more than the most commonly used routines for the most simple problems but the data storage techniques for the more complicated options should save a considerable amount of space.

Oren, J. A.↗

The effect of grid transparency and finite collector size on determining ion temperature and density by the retarding potential analyzer

The analysis of ion data from retarding potential analyzers (RPA's) is generally done under the planar approximation, which assumes that the grid transparency is constant with angle of incidence and that all ions reaching the plane of the collectors are collected. These approximations are not valid for situations in which the ion thermal velocity is comparable to the vehicle velocity, causing ions to enter the RPA with high average transverse velocity. To investigate these effects, the current-voltage curves for H+ at 4000 K were calculated, taking into account the finite collector size and the variation of grid transparency with angle. These curves are then analyzed under the planar approximation. The results show that only small errors in temperature and density are introduced for an RPA with typical dimensions; and that even when the density error is substantial for non-typical dimensions, the temperature error remains minimal.

Troy, B. E., Jr.↗