Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ansys”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Design and Analysis of Liquid Lithium Plasma Facing Components

In this study, liquid metal (LM) on plasma-facing components (PFCs) creates a renewable protective cover enhancing power exhaust and protecting the solid substrate. Additionally, energy confinement improvement through particle pumping can be achieved in the case of liquid lithium (LL). A new variant of PFCs was recently introduced at Princeton Plasma Physics Laboratory (PPPL) where a porous wall is used to stabilize the LM surface, while using magnetohydrodynamic (MHD) drive to push the LM flow inside the component. This arrangement allows efficient heat exhaust, and enhanced control of the LM surface temperature, leading to spatial control of evaporation and condensation of LL on the plasma interface. This feature is particularly attractive when vapor shielding is introduced to allow heat flux redistribution. This system has the advantage that as the heat flux increases, the evaporation rate will increase, while decreasing heat flux will decrease the evaporation rate of lithium, ideally creating a feedback effect which could self-regulate the amount of lithium evaporated. Analytical and numerical models for LL PFCs were developed in PPPL. To calculate the target temperature distribution for the case of evaporation from the divertor, we apply an iterative process allowing two-way coupling between the fluid-kinetic analysis of plasma using SOLPS-ITER code and the flow and heat transfer analysis of the PFC using an analytical model. In the last stage, the results are validated using computational fluid dynamics (CFD) analysis with customized version of the CFX code from ANSYS. CFX was modified at PPPL to allow MHD analysis at the high magnetic field typical for fusion applications. Results of the analysis for NSTX-U tokamak conditions will be presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimization of Air-Gap Profile in Interior Permanent-Magnet Synchronous Motors for Torque Ripple Mitigation

Interior permanent magnet synchronous motors (IPMSMs) have been widely used due to their high efficiency and high power density. Minimization of torque pulsation resulting in vibration and acoustic noise is one of the important design considerations for IPMSMs. In this paper, a grid on/off search method for the rotor profile is proposed to mitigate torque pulsation. Selection of the rotor profile is due to the fact that air-gap is the most sensitive parameter in electric machines wherein changes in flux densities can cause substantial differences in the distribution of forces. A layer comprised of 20 partitions with a 0.1 mm thickness and 3 degrees wide grids have been introduced to the rotor surface for each pole and the possible geometries have been analyzed using finite element method (FEM) in ANSYS Maxwell. An optimal design was found that has the lowest torque ripple with a higher average torque compared to the original design. Genetic algorithm (GA) has also been applied to the method to automate the coupling between Maxwell and Matlab thereby saving the simulation time. Finally, complete structural analysis has been done for both of the original and optimal designs to verify the superiority and feasibility of the proposed design.

42 ENGINEERING↗

Experimental and Numerical Analysis of Additively Manufactured Coupons With Parallel Channels and Inline Wall Jets

Present paper developed a series of additively manufactured parallel cooling channels with streamwise wall jets inside, which could be suitable for double-wall and near-wall cooling configurations in gas turbine hot section components. The tested coupons consisted of parallel channels, each channel further divided into small chambers using several spanwise separation walls. Height of these walls was kept less than channel height, thus forming a slot with one of the end walls. Coolant entered from one side of channel and formed streamwise wall jet while crossing through the slot over to the downstream chamber. The test coupons were additively manufactured by selective laser sintering (SLS) technique using Inconel 718 alloy. Steady-state heat transfer experiments with constant wall temperature boundary condition were performed to analyze effect of pitch between subsequent slots and blockage ratio (ratio of separation wall height to channel height) on heat transfer. The channel Reynolds number ranged from 1800 to 5000. Numerical simulations were performed using ANSYS cfx solver with SST k–ω turbulence model to obtain detailed understanding of existing flow field. Experimental results showed heat transfer enhancement of up to 6.5 times that of a smooth channel for the highest blockage ratio of 0.75. Numerical results revealed complex flow field which consisted of wall jets along with impingement, separation, and recirculation zones in each chamber. For all configurations, gain in heat transfer was accompanied with high pressure drops. However, coupled with the high heat transfer, this design could lead to potential coolant savings.

Engineering↗

Pairing Directional Solar Inputs From Ray Tracing to Solar Receiver/Reactor Heat Transfer Models on Unstructured Meshes: Development and Case Studies

A novel method for pairing surface irradiation and volumetric absorption from Monte Carlo ray tracing to computational heat transfer models is presented. The method is well-suited to directionally and spatially complex concentrated radiative inputs (e.g., solar receivers and reactors). The method employs a generalized algorithm for directly mapping absorbed rays from a Monte Carlo ray tracing model to boundary or volumetric source terms in the computational mesh. The algorithm is compatible with unstructured, two and three-dimensional meshes with varying element shapes. Four case studies were performed on a directly irradiated, windowed solar thermochemical reactor model to validate the method. The method was shown to conserve energy and preserve spatial variation when mapping rays from a Monte Carlo ray tracing model to a computational heat transfer model in ansys fluent.

14 SOLAR ENERGY↗

On-Sun Testing of a High-Temperature Solar Receiver's Flux Distribution

Concentrated solar power (CSP) is a promising technology in transitioning to renewable energy because of its abundance in nature and thermal energy storage (TES) capability. Among the four types of available CSP technology, including parabolic trough, linear Fresnel, power tower, and parabolic dishes, a power tower using a central receiver has more potential to generate high-temperature heat in a scale supporting power cycles efficiency and achieve low levelized cost of energy (LCOE). Other than the conventional type of receiver design, the high-absorptive receiver concept developed and presented in this paper is novel in its design approach. The novel receiver design originated from National Renewable Energy Laboratory (NREL) consists of an array of solar flux absorb tubes. The solar absorb tubes require uniform flux distribution and in-depth flux penetration through the three different reflective sections of tubes in a hexagonal shape. To evaluate this unique receiver design and thermal performance, the flux distribution, flux uniformity, and intensity were numerically simulated using ansys fluent and SolTrace modeling program. On-sun testing has been done at NREL high flux solar testing facility, based on the computational analysis.

clean energy↗

Three-Dimensional Permeability of Thick-Section Glass Fabric Reinforced Polymer Composite by Vacuum-Assisted Resin Infusion Molding

Abstract Determination of permeability of thick-section glass fabric preforms with fabric layers of different architectures is critical for manufacturing large, thick composite structures with complex geometry, such as wind turbine blades. The thick-section reinforcement permeability is inherently three-dimensional and needs to be obtained for accurate composite processing modeling and analysis. Numerical simulation of the liquid stage of vacuum-assisted resin infusion molding (VARIM) is important to advance the composite manufacturing process and reduce processing-induced defects. In this research, the 3D permeability of thick-section E-glass fabric reinforcement preforms is determined, and the results are validated by a comparison between flow front progressions from experiments and from numerical simulations using ansys fluent software. The orientation of the principal permeability axes were unknown prior to experiments. The approach used in this research differs from those in literature in that the through-thickness permeability is determined as a function of flow front positions along the principal axes and the in-plane permeabilities and is not dependent on the inlet radius. The approach was tested on reinforcements with fabric architectures which vary through-the-thickness direction, such as those in a spar cap of a wind turbine blade. The computational simulations of the flow-front progression through-the-thickness were consistent with experimental observations.

Engineering↗

Effect of Quartz Aperture Covers on the Fluid Dynamics and Thermal Efficiency of Falling Particle Receivers

Falling particle receivers are an emerging technology for use in concentrating solar power systems. In this paper, quartz half-shells are investigated for use as full or partial aperture covers to reduce receiver thermal losses. Quartz half-shell aperture covers offer the ability to minimally interfere with incoming solar radiation from the heliostat field while obstructing thermal radiation and advection from leaving the receiver cavity. The fluid dynamics and heat transfer of a receiver subdomain and surrounding air are modeled using ANSYS®FLUENT We compare the percentage of total incident solar power lost due to conduction through the receiver walls, advective losses through the aperture, and radiation exiting the aperture. Contrary to expected outcomes, results show that quartz aperture covers can increase radiative losses and result in modest to nonexistent reductions in advective losses. The increased radiative losses are driven by elevated quartz half-shell temperatures and have the potential to be mitigated by active cooling and/or material selection. Quartz half-shell total transmissivity was measured experimentally using a radiometer and the National Solar Thermal Test Facility heliostat field with values up to 0.97 ± 0.01. Quartz half-shell aperture covers did not yield expected efficiency gains in numerical results due to increased radiative losses, but efficiency improvement in some numerical results and the performance of quartz half-shells subject to concentrated solar radiation suggest that quartz half-shell aperture covers should be investigated further.

14 SOLAR ENERGY↗

An Investigation of the Effects of Volume Fraction on Drag Coefficient of Non-Spherical Particles Using PR-DNS

Prediction of the drag coefficient is required in gas-particle multiphase flow modeling and simulation. Experimental data and correlations on the fixed-bed system of spherical particles with high volume fractions for various possible arrangements are available in the literature. However, the effect of volume fraction on the drag coefficient of non-spherical particles is not well studied. In solving the momentum equation, the volume fraction plays a vital role in determining the flow resistances. In this paper, we study the impact of volume fraction in the range of 0.069 to 0.65 on the drag coefficient using the computational fluid dynamics (CFD) simulation of air for Reynold number in the range of 10 to 10000 using particle resolved direct numerical solution (PR-DNS). Regular non-spherical particles such as a cube, tetrahedron, and spheroids are used in this study since their single particle’s drag coefficient data are available in the literature for comparison. For this work, the simulations are carried out in the Ansys Fluent using polyhedral mesh, which consumes significantly less computational time and power. The study showed the sphericity and volume fraction have significant impact on the bed pressure drop and average drag coefficient of the particles in the bed especially in high Reynolds number regime. The bed of the spheroid experiences the lowest drag being the most streamlined particle, and the particles with the edges result in a large drag coefficient due to flow separation at the discontinuity. The vector plots verify this behavior where large wake regions are observed behind the tetrahedron particle.

Mahyawansi, Pratik↗

Preliminary Verification and Validation of WEC-Sim, an Open-Source Wave Energy Converter Design Tool: Preprint

To promote and support the wave energy industry, a wave energy converter (WEC) design tool, WEC-Sim, is being developed by Sandia National Laboratories and the National Renewable Energy Laboratory. In this paper, the WEC-Sim code is used to model a point absorber WEC designed by the U.S. Department of Energy's reference model project. Preliminary verification was performed by comparing results of the WEC-Sim simulation through a code-to-code comparison, utilizing the commercial codes ANSYS-AQWA, WaveDyn, and OrcaFlex. A preliminary validation of the code was also performed by comparing WEC-Sim simulation results to experimental wave tank tests.

16 TIDAL AND WAVE POWER↗

New Developments and Capabilities Within WEC-Sim

WEC-Sim is an open-source software for simulating wave energy converters and has been actively developed and applied since its initial release in 2014 to simulate a wide variety of device archetypes. WEC-Sim is developed jointly by the National Renewable Energy Laboratory and Sandia National Laboratories within the MATLAB/SIMULINK environment. A general wave-to-wire model begins with a deployment site resource characterization, which is used to complete the hydrodynamic simulation of wave energy converters (WEC), with the power generation profile imported to a grid simulator to understand the influence on the local electrical network. While modeling the entire wave-to-wire is difficult and encompasses multiple time scales and physics, WEC-Sim is focused on the hydrodynamics simulation to predict, analyze, and optimize WEC dynamics and power performance. WEC-Sim simulations are performed in the time domain based on the radiation and diffraction method using hydrodynamics coefficients derived from boundary element method (BEM)-based frequency-domain potential flow solvers (e.g., WAMIT, NEMOH, Capytaine, or ANSYS-AQWA). With this level of modeling fidelity, WEC-Sim can handle floating body hydrodynamics, mechanical and electrical power generation methods, advanced control implementation, mooring systems, and other unique applications such as desalination. Additional WEC-Sim functionalities include pre-built Simulink blocks and MATLAB scripts that can simulate a wide range of floating systems and the corresponding auxiliary subsystems. The developers of WEC-Sim continue to release new versions of the software, at least annually, with the latest release in September 2022. These releases include bug fixes, updates to software documentation, as well as new features to expand WEC-Sim's capabilities to model a wide range of WEC concepts. This publication will highlight the new features added to WEC-Sim between versions 4.1.0 to 5.0.1, which spans a 2-year period from June 2020 to September 2022. New features described here include topics such as continuous integration checks, revised Morison Element and nonlinear hydro implementations, run directly from Simulink (required for hardware-in-the-loop execution), BEMIO updates to import Capytaine BEM hydrodynamics, addition of cable blocks, and new wave visualization features.

TIDAL AND WAVE POWER↗

THERMAL STRESS ANALYSIS OF A SPENT NUCLEAR FUEL CANISTER

The potential for chloride induced stress corrosion cracking (CISCC) in spent nuclear fuel dry storage canisters is a current topic of research by the US Department of Energy Spent Fuel and Waste Science and Technology program. One of the important prerequisites for CISCC is a tensile residual stress state. This study utilizes computational models to provide an initial analysis of thermal stresses in a generic spent nuclear fuel canister. A STAR-CCM+ thermal fluid model provides a temperature profile analysis of the canister based on four different ambient temperature conditions. An ANSYS APDL finite element model incorporates the temperature profiles to analyze the thermal stresses in the canister. The calculated thermal stress magnitudes are in the range of 10 MPa to 80 MPa, which could be significant for crack propagation through the canister wall. The maximum thermal stress is not a concern for the structural failure of the canister, but it is high enough that it is a significant contribution to the total stress state of the canister wall, which also includes residual stress from fabrication, internal pressure from helium cover gas, and potential transient mechanical loads, such as earthquakes. This paper describes the initial finite element thermal stress analysis that was completed in 2020, reports the initial findings, and identifies areas where model refinement is still needed to complete this work in the future.

Jensen, Ben J.↗

Rolling contact fatigue in high vacuum using ion plated nickel-copper-silver solid lubrication

Ion plated, nickel-copper-silver coated steel ball bearings that were tested in rolling contact fatigue (RCF) experiments in high vacuum are presented in this article. ANSI T5 ball bearings were coated with approximately 10 nm of nickel-copper followed by 100 nm of silver using a dc ion plating process. The balls were then tested for RCF in vacuum in the 10{sup -7} Torr range at 130 Hz rotational speed and at 4.1 GPa Hertzian contact stress. The significance of this work is in the extension of RCF testing to an ultrahigh vacuum (UHV) application using silver as a lubricant instead of oil. The effects of pressure and voltage on the ion plating process were also investigated using scanning electron microscopy and RCF life testing in UHV. Test results with a ball size of 5/16 in. in UHV show that deposition at voltages greater than 2.5 kV shortens the RCF life and introduces a unique failure mode. Voltage and pressure fluctuations during the deposition process result in significant thickness monitor measurement errors as well. A regulator control scheme that minimizes the process pressure overshoot is also simulated.

36 MATERIALS SCIENCE↗

Feature Extraction for Pipeline Defects Inspection Based Upon Distributed Acoustic Fiber Optic Sensing Data

Fiber-optic distributed acoustic sensing (DAS) is becoming an increasingly important tool for real-time monitoring of energy and civil infrastructure structural health such as pipelines. We present a systematic theoretical study of the potential for DAS to be directly coupled with guided ultrasonic waves typically used in conventional acoustic non-destructive evaluation (NDE) methods for real-time pipeline health monitoring. We are referring to this innovative new NDE technique as ultrasonic guided wave and optical fiber sensor fusion. In the practical application of DAS coupled with guided ultrasonic waves, the structural design of (1) the specific guided waves excited, (2) the physical installation of the acoustic transducers and the fiber optic sensors, and (3) the functional performance specifications (gauge length, sensitivity, Etc.) of fiber optic DAS have an important influence on overall capabilities of the monitoring system. Meanwhile, physics-based analysis of acoustic waves is still a challenge due to the complex nature of the Lamb wave when it propagates, scatters, and disperses in the presence of structural defects. In this work, we simulate carbon steel pipes relevant for oil and gas pipeline applications with diameters of approximately 6-12” and wall thickness of 0.5” as the objects to be monitored. By establishing and implementing these capabilities, we seek to pursue an in-depth study on structural parameter optimization of DAS network, measurement range, and signal processing with an ultimate goal of increasing the sensitivity and efficacy of DAS to defect identification for various modes of corrosion expected in practice. To study the characteristics of scattered acoustic waves and performance of DAS for defect identification, we simulated the response of DAS for multiple pipe structures, defect types, and DAS sensor network configuration using finite element software Ansys, then the properties of signal response are extracted to construct defect-sensitive features. The raw data simulated, and the associated features extracted can ultimately be utilized as annotated training data to benchmark various designs for DAS applications, guided acoustic excitation sources, and learning model parameters to enhance early detection of potentially problematic defects.

Pipeline Defects Inspection, Fiber-optic sensors, ↗

High-ratio grid considerations in mobile chest radiography

Purpose: Grids are often not used in mobile chest radiography, and when used, they have a low ratio and are often inaccurately aligned. Recently, a mobile radiography automatic grid alignment system (MRAGA) was developed that accurately and automatically aligns the focal spot with the grid. The objective of this study is to investigate high-ratio grid tradeoffs in mobile chest radiography at fixed patient dose when the focal spot lies on the focal axis of the grid. Methods: The chest phantoms (medium and large) used in this study were modifications of the ANSI (American National Standards Institute) chest phantom and consisted of layers of Lucite Trade-Mark-Sign , aluminum, and air. For the large chest phantom, the amount of Lucite and aluminum was increased by 50% over the medium phantom. Further modifications included a mediastinum insert and the addition of contrast targets in the lung and mediastinum regions. Five high-ratio grids were evaluated and compared to the nongrid results at x-ray tube potentials of 80, 90, 100, and 110 kVp for both phantoms. The grids investigated were from two manufacturers: 12:1 and 15:1 aluminum interspace grids from one and 10:1, 13:1, and 15:1 fiber interspace grids from another. MRAGA was employed to align the focal spot with the grid. All exposures for a given kVp and phantom size were made using the same current-time product (CTP). The phantom images were acquired using computed radiography, and contrast-to-noise ratios (CNR) and CNR improvement factors (k{sub CNR}) were determined from the resultant images. The noise in the targets and the contrast between the targets and their backgrounds were calculated using a local detrending correction, and the CNR was calculated as the ratio of the target contrast to the background noise. k{sub CNR} was defined as the ratio of the CNR imaged with the grid divided by the CNR imaged without a grid. Results: The CNR values obtained with a high-ratio grid were 4%-65% higher than those obtained without a grid at the same phantom dose. The improvement was greater for the large chest phantom than the medium chest phantom and greater for the mediastinum targets than for the lung targets. In general, the fiber interspace grids performed better than the aluminum interspace grids. In the lung, k{sub CNR} for both types of grids exhibited little dependence on kVp or grid ratio. In the mediastinum, k{sub CNR} decreased 4%-10% with increasing kVp, and varied up to 5.3% with grid ratio. Conclusions: When the focal spot is accurately aligned with the grid, the use of a high-ratio grid in mobile chest radiography improves image quality with no increase in dose to the phantom. For the grids studied, the performance of the fiber interspace grids was superior to the performance of the aluminum interspace grids, with the fiber interspace 13:1 grid producing the best overall results for the medium chest phantom and the fiber interspace 15:1 producing the best overall results for the large chest phantom.

60 APPLIED LIFE SCIENCES↗

Estimation of organ and effective dose due to Compton backscatter security scans

Purpose: To estimate organ and effective radiation doses due to backscatter security scanners using Monte Carlo simulations and a voxelized phantom set. Methods: Voxelized phantoms of male and female adults and children were used with the GEANT4 toolkit to simulate a backscatter security scan. The backscatter system was modeled based on specifications available in the literature. The simulations modeled a 50 kVp spectrum with 1.0 mm-aluminum-equivalent filtration and a previously measured exposure of approximately 4.6 {mu}R at 30 cm from the source. Photons and secondary interactions were tracked from the source until they reached zero kinetic energy or exited from the simulation's boundaries. The energy deposited in the phantoms' respective organs was tallied and used to calculate total organ dose and total effective dose for frontal, rear, and full scans with subjects located 30 and 75 cm from the source. Results: For a full screen, all phantoms' total effective doses were below the established 0.25 {mu}Sv standard, with an estimated maximum total effective dose of 0.07 {mu}Sv for full screen of a male child. The estimated maximum organ dose due to a full screen was 1.03 {mu}Gy, deposited in the adipose tissue of the male child phantom when located 30 cm from the source. All organ dose estimates had a coefficient of variation of less than 3% for a frontal scan and less than 11% for a rear scan. Conclusions: Backscatter security scanners deposit dose in organs beyond the skin. The effective dose is below recommended standards set by the Health Physics Society (HPS) and the American National Standards Institute (ANSI) assuming the system provides a maximum exposure of approximately 4.6 {mu}R at 30 cm.

60 APPLIED LIFE SCIENCES↗

Verification of TG-61 dose for synchrotron-produced monochromatic x-ray beams using fluence-normalized MCNP5 calculations

Purpose: Ion chamber dosimetry is being used to calibrate dose for cell irradiations designed to investigate photoactivated Auger electron therapy at the Louisiana State University Center for Advanced Microstructures and Devices (CAMD) synchrotron facility. This study performed a dosimetry intercomparison for synchrotron-produced monochromatic x-ray beams at 25 and 35 keV. Ion chamber depth-dose measurements in a polymethylmethacrylate (PMMA) phantom were compared with the product of MCNP5 Monte Carlo calculations of dose per fluence and measured incident fluence. Methods: Monochromatic beams of 25 and 35 keV were generated on the tomography beamline at CAMD. A cylindrical, air-equivalent ion chamber was used to measure the ionization created in a 10 Multiplication-Sign 10 Multiplication-Sign 10-cm{sup 3} PMMA phantom for depths from 0.6 to 7.7 cm. The American Association of Physicists in Medicine TG-61 protocol was applied to convert measured ionization into dose. Photon fluence was determined using a NaI detector to make scattering measurements of the beam from a thin polyethylene target at angles 30 Degree-Sign -60 Degree-Sign . Differential Compton and Rayleigh scattering cross sections obtained from xraylib, an ANSI C library for x-ray-matter interactions, were applied to derive the incident fluence. MCNP5 simulations of the irradiation geometry provided the dose deposition per photon fluence as a function of depth in the phantom. Results: At 25 keV the fluence-normalized MCNP5 dose overestimated the ion-chamber measured dose by an average of 7.2 {+-} 3.0%-2.1 {+-} 3.0% for PMMA depths from 0.6 to 7.7 cm, respectively. At 35 keV the fluence-normalized MCNP5 dose underestimated the ion-chamber measured dose by an average of 1.0 {+-} 3.4%-2.5 {+-} 3.4%, respectively. Conclusions: These results showed that TG-61 ion chamber dosimetry, used to calibrate dose output for cell irradiations, agreed with fluence-normalized MCNP5 calculations to within approximately 7% and 3% at 25 and 35 keV, respectively.

60 APPLIED LIFE SCIENCES↗

SU-E-I-22: Dependence On Calibration Phantom and Field Area of the Conversion Factor Used to Calculate Skin Dose During Neuro-Interventional Fluoroscopic Procedures

Purpose: To determine the appropriate calibration factor to use when calculating skin dose with our real-time dose-tracking system (DTS) during neuro-interventional fluoroscopic procedures by evaluating the difference in backscatter from different phantoms and as a function of entrance-skin field area. Methods: We developed a dose-tracking system to calculate and graphically display the cumulative skin-dose distribution in real time. To calibrate the DTS for neuro-interventional procedures, a phantom is needed that closely approximates the scattering properties of the head. We compared the x-ray backscatter from eight phantoms: 20-cm-thick solid water, 16-cm diameter water-filled container, 16-cm CTDI phantom, modified-ANSI head phantom, 20-cm-thick PMMA, Kyoto-Kagaku PBU- 50 head, Phantom-Labs SK-150 head, and RSD RS-240T head. The phantoms were placed on the patient table with the entrance surface at 15 cm tube-side from the isocenter of a Toshiba Infinix C-arm, and the entrance-skin exposure was measured with a calibrated 6-cc PTW ionization chamber. The measurement included primary radiation, backscatter from the phantom and forward scatter from the table and pad. The variation in entrance-skin exposure was also measured as a function of the skin-entrance area for a 30x30 cm by 20-cm-thick PMMA phantom and the SK-150 head phantom using four different added beam filters. Results: The entranceskin exposure values measured for eight different phantoms differed by up to 12%, while the ratio of entrance exposure of all phantoms relative to solid water showed less than 3% variation with kVp. The change in entrance-skin exposure with entrance-skin area was found to differ for the SK-150 head compared to the 20-cm PMMA phantom and the variation with field area was dependent on the added beam filtration. Conclusion: To accurately calculate skin dose for neuro-interventional procedures with the DTS, the phantom for calibration should be carefully chosen since different phantoms can contribute different backscatter for identical exposure parameters. Research supported in part by Toshiba Medical Systems and NIH Grants R43FD0158401, R44FD0158402 and R01EB002873.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-I-40: New Method for Measurement of Task-Specific, High-Resolution Detector System Performance

Purpose: Although generalized linear system analytic metrics such as GMTF and GDQE can evaluate performance of the whole imaging system including detector, scatter and focal-spot, a simplified task-specific measured metric may help to better compare detector systems. Methods: Low quantum-noise images of a neuro-vascular stent with a modified ANSI head phantom were obtained from the average of many exposures taken with the high-resolution Micro-Angiographic Fluoroscope (MAF) and with a Flat Panel Detector (FPD). The square of the Fourier Transform of each averaged image, equivalent to the measured product of the system GMTF and the object function in spatial-frequency space, was then divided by the normalized noise power spectra (NNPS) for each respective system to obtain a task-specific generalized signal-to-noise ratio. A generalized measured relative object detectability (GM-ROD) was obtained by taking the ratio of the integral of the resulting expressions for each detector system to give an overall metric that enables a realistic systems comparison for the given detection task. Results: The GM-ROD provides comparison of relative performance of detector systems from actual measurements of the object function as imaged by those detector systems. This metric includes noise correlations and spatial frequencies relevant to the specific object. Additionally, the integration bounds for the GM-ROD can be selected to emphasis the higher frequency band of each detector if high-resolution image details are to be evaluated. Examples of this new metric are discussed with a comparison of the MAF to the FPD for neuro-vascular interventional imaging. Conclusion: The GM-ROD is a new direct-measured task-specific metric that can provide clinically relevant comparison of the relative performance of imaging systems. Supported by NIH Grant: 2R01EB002873 and an equipment grant from Toshiba Medical Systems Corporation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗