Search NASA⌕ Search

SEARCH · Search NASA

Results for “Automatic planning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

A multimodality segmentation framework for automatic target delineation in head and neck radiotherapy

Purpose: To develop an automatic segmentation algorithm integrating imaging information from computed tomography (CT), positron emission tomography (PET), and magnetic resonance imaging (MRI) to delineate target volume in head and neck cancer radiotherapy. Methods: Eleven patients with unresectable disease at the tonsil or base of tongue who underwent MRI, CT, and PET/CT within two months before the start of radiotherapy or chemoradiotherapy were recruited for the study. For each patient, PET/CT and T1-weighted contrast MRI scans were first registered to the planning CT using deformable and rigid registration, respectively, to resample the PET and magnetic resonance (MR) images to the planning CT space. A binary mask was manually defined to identify the tumor area. The resampled PET and MR images, the planning CT image, and the binary mask were fed into the automatic segmentation algorithm for target delineation. The algorithm was based on a multichannel Gaussian mixture model and solved using an expectation–maximization algorithm with Markov random fields. To evaluate the algorithm, we compared the multichannel autosegmentation with an autosegmentation method using only PET images. The physician-defined gross tumor volume (GTV) was used as the “ground truth” for quantitative evaluation. Results: The median multichannel segmented GTV of the primary tumor was 15.7 cm{sup 3} (range, 6.6–44.3 cm{sup 3}), while the PET segmented GTV was 10.2 cm{sup 3} (range, 2.8–45.1 cm{sup 3}). The median physician-defined GTV was 22.1 cm{sup 3} (range, 4.2–38.4 cm{sup 3}). The median difference between the multichannel segmented and physician-defined GTVs was −10.7%, not showing a statistically significant difference (p-value = 0.43). However, the median difference between the PET segmented and physician-defined GTVs was −19.2%, showing a statistically significant difference (p-value =0.0037). The median Dice similarity coefficient between the multichannel segmented and physician-defined GTVs was 0.75 (range, 0.55–0.84), and the median sensitivity and positive predictive value between them were 0.76 and 0.81, respectively. Conclusions: The authors developed an automated multimodality segmentation algorithm for tumor volume delineation and validated this algorithm for head and neck cancer radiotherapy. The multichannel segmented GTV agreed well with the physician-defined GTV. The authors expect that their algorithm will improve the accuracy and consistency in target definition for radiotherapy.

60 APPLIED LIFE SCIENCES↗

MO-FG-CAMPUS-TeP2-05: Optimizing Stereotactic Radiosurgery Treatment of Multiple Brain Metastasis Lesions with Individualized Rotational Arc Trajectories

Purpose: Radiosurgery of multiple (n>4) brain metastasis lesions requires 3–4 noncoplanar VMAT arcs with excessively high monitor units and long delivery time. We investigated whether an improved optimization technique would decrease the needed arc numbers and increase the delivery efficiency, while improving or maintaining the plan quality. Methods: The proposed 4pi arc space optimization algorithm consists of two steps: automatic couch angle selection followed by aperture generation for each arc with optimized control points distribution. We use a greedy algorithm to select the couch angles. Starting from a single coplanar arc plan we search through the candidate noncoplanar arcs to pick a single noncoplanar arc that will bring the best plan quality when added into the existing treatment plan. Each time, only one additional noncoplanar arc is considered making the calculation time tractable. This process repeats itself until desired number of arc is reached. The technique is first evaluated in coplanar arc delivery scheme with testing cases and then applied to noncoplanar treatments of a case with 12 brain metastasis lesions. Results: Clinically acceptable plans are created within minutes. For the coplanar testing cases the algorithm yields singlearc plans with better dose distributions than that of two-arc VMAT, simultaneously with a 12–17% reduction in the delivery time and a 14–21% reduction in MUs. For the treatment of 12 brain mets while Paddick conformity indexes of the two plans were comparable the SCG-optimization with 2 arcs (1 noncoplanar and 1 coplanar) significantly improved the conventional VMAT with 3 arcs (2 noncoplanar and 1 coplanar). Specifically V16 V10 and V5 of the brain were reduced by 11%, 11% and 12% respectively. The beam delivery time was shortened by approximately 30%. Conclusion: The proposed 4pi arc space optimization technique promises to significantly reduce the brain toxicity while greatly improving the treatment efficiency.

60 APPLIED LIFE SCIENCES↗

Registration of clinical volumes to beams-eye-view images for real-time tracking

Purpose: The authors combine the registration of 2D beam’s eye view (BEV) images and 3D planning computed tomography (CT) images, with relative, markerless tumor tracking to provide automatic absolute tracking of physician defined volumes such as the gross tumor volume (GTV). Methods: During treatment of lung SBRT cases, BEV images were continuously acquired with an electronic portal imaging device (EPID) operating in cine mode. For absolute registration of physician-defined volumes, an intensity based 2D/3D registration to the planning CT was performed using the end-of-exhale (EoE) phase of the four dimensional computed tomography (4DCT). The volume was converted from Hounsfield units into electron density by a calibration curve and digitally reconstructed radiographs (DRRs) were generated for each beam geometry. Using normalized cross correlation between the DRR and an EoE BEV image, the best in-plane rigid transformation was found. The transformation was applied to physician-defined contours in the planning CT, mapping them into the EPID image domain. A robust multiregion method of relative markerless lung tumor tracking quantified deviations from the EoE position. Results: The success of 2D/3D registration was demonstrated at the EoE breathing phase. By registering at this phase and then employing a separate technique for relative tracking, the authors are able to successfully track target volumes in the BEV images throughout the entire treatment delivery. Conclusions: Through the combination of EPID/4DCT registration and relative tracking, a necessary step toward the clinical implementation of BEV tracking has been completed. The knowledge of tumor volumes relative to the treatment field is important for future applications like real-time motion management, adaptive radiotherapy, and delivered dose calculations.

60 APPLIED LIFE SCIENCES↗

The navigation system of the JPL robot

The control structure of the JPL research robot and the operations of the navigation subsystem are discussed. The robot functions as a network of interacting concurrent processes distributed among several computers and coordinated by a central executive. The results of scene analysis are used to create a segmented terrain model in which surface regions are classified by traversibility. The model is used by a path planning algorithm, PATH, which uses tree search methods to find the optimal path to a goal. In PATH, the search space is defined dynamically as a consequence of node testing. Maze-solving and the use of an associative data base for context dependent node generation are also discussed. Execution of a planned path is accomplished by a feedback guidance process with automatic error recovery.

Thompson, A. M.↗

The Automated Planetary Space Station

Results are presented for a study on mission definition and design to determine broad technology directions and needs for advanced planetary spacecraft and future planetary missions. The discussion covers mission selection, system design, and technology assessment and review for a multicomponent spacecraft exploration facility provided with nuclear power propulsion. As an example, the Automated Planetary Space Station at Jupiter is examined as a generic concept which has the capability of conducting in-depth investigations of different aspects of the entire Jovian system. Mission planning is discussed relative to low-thrust trajectory control, automatic target identification and landing, roving vehicle operation, and automated sample analysis.

Ivie, C. V.↗

Fifth Conference on Artificial Intelligence for Space Applications

The Fifth Conference on Artificial Intelligence for Space Applications brings together diverse technical and scientific work in order to help those who employ AI methods in space applications to identify common goals and to address issues of general interest in the AI community. Topics include the following: automation for Space Station; intelligent control, testing, and fault diagnosis; robotics and vision; planning and scheduling; simulation, modeling, and tutoring; development tools and automatic programming; knowledge representation and acquisition; and knowledge base/data base integration.

Odell, Steve L.↗

Development of use of an Operational Procedure Information System (OPIS) for future space missions

A MS-Windows based electronic procedure system, called OPIS (Operational Procedure Information System), was developed. The system consists of two parts, the editor, for 'writing' the procedure and the notepad application, for the usage of the procedures by the crew during training and flight. The system is based on standardized, structured procedure format and language. It allows the embedding of sketches, photos, animated graphics and video sequences and the access to off-nominal procedures by linkage to an appropriate database. The system facilitates the work with procedures of different degrees of detail, depending on the training status of the crew. The development of a 'language module' for the automatic translation of the procedures, for example into Russian, is planned.

Illmer, N.↗

Status of automatic guidance systems for rotorcraft in low altitude flight

Rotorcraft operating in high-threat environments fly close to the earth's surface to utilize surrounding terrain, vegetation, or man-made objects to minimize the risk of being detected by an enemy. The piloting of the rotorcraft is at best a very demanding task and the pilots need help from on-board automation tools in order to devote more time to mission-related activities. The Automated Nap-of-the-Earth (NOE) Flight Program is a cooperative NASA/Army program aimed at the development of technologies for enhancing piloted low-altitude/NOE flight path management and control through computer and sensor aiding. The long-term objective is to work towards achieving automation for aiding the pilot in NOE flight with a flight demonstration of resulting computer/sensor aiding concepts at an established course. The technology for pilot-centered NOE automation is not currently available. Success in automating NOE functions will depend on major breakthroughs in real-time flight path planning algorithms, effective methods for the pilot to interface to the automatic modes, understanding of visual images, sensor data processing/fusion, and sensor development. Our approach to developing the technologies required to solve this problem consist of the following phases: (1) algorithm development, (2) laboratory evaluation, (3) piloted ground simulation, and (4) evaluation in flight. An overview of the research in this area at NASA Ames Research Center is given.

Sridhar, Banavar↗

AI-Based Quantification of Planned Radiation Therapy Dose to Cardiac Structures and Coronary Arteries in Patients With Breast Cancer

The purpose of this work is to develop and evaluate an automatic deep learning method for segmentation of cardiac chambers and large arteries, and localization of the 3 main coronary arteries in radiation therapy planning on computed tomography (CT). In addition, a second purpose is to determine the planned radiation therapy dose to cardiac structures for breast cancer therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Program Helps Design Tests Of Developmental Software

Computer program called "A Formal Test Representation Language and Tool for Functional Test Designs" (TRL) provides automatic software tool and formal language used to implement category-partition method and produce specification of test cases in testing phase of development of software. Category-partition method useful in defining input, outputs, and purpose of test-design phase of development and combines benefits of choosing normal cases having error-exposing properties. Traceability maintained quite easily by creating test design for each objective in test plan. Effort to transform test cases into procedures simplified by use of automatic software tool to create cases based on test design. Method enables rapid elimination of undesired test cases from consideration and facilitates review of test designs by peer groups. Written in C language.

Hops, Jonathan↗

SU-F-T-384: Step and Shoot IMRT, VMAT and Autoplan VMAT Nasopharnyx Plan Robustness to Linear Accelerator Delivery Errors

Purpose: To identify the robustness of different treatment techniques in respect to simulated linac errors on the dose distribution to the target volume and organs at risk for step and shoot IMRT (ssIMRT), VMAT and Autoplan generated VMAT nasopharynx plans. Methods: A nasopharynx patient dataset was retrospectively replanned with three different techniques: 7 beam ssIMRT, one arc manual generated VMAT and one arc automatically generated VMAT. Treatment simulated uncertainties: gantry, collimator, MLC field size and MLC shifts, were introduced into these plans at increments of 5,2,1,−1,−2 and −5 (degrees or mm) and recalculated in Pinnacle. The mean and maximum doses were calculated for the high dose PTV, parotids, brainstem, and spinal cord and then compared to the original baseline plan. Results: Simulated gantry angle errors have <1% effect on the PTV, ssIMRT is most sensitive. The small collimator errors (±1 and ±2 degrees) impacted the mean PTV dose by <2% for all techniques, however for the ±5 degree errors mean target varied by up to 7% for the Autoplan VMAT and 10% for the max dose to the spinal cord and brain stem, seen in all techniques. The simulated MLC shifts introduced the largest errors for the Autoplan VMAT, with the larger MLC modulation presumably being the cause. The most critical error observed, was the MLC field size error, where even small errors of 1 mm, caused significant changes to both the PTV and the OAR. The ssIMRT is the least sensitive and the Autoplan the most sensitive, with target errors of up to 20% over and under dosages observed. Conclusion: For a nasopharynx patient the plan robustness observed is highest for the ssIMRT plan and lowest for the Autoplan generated VMAT plan. This could be caused by the more complex MLC modulation seen for the VMAT plans. This project is supported by a grant from NSW Cancer Council.

60 APPLIED LIFE SCIENCES↗

SU-E-T-138: Automated Chart Review Module Including Cross-Vendor Data Transfer Verification Developed for IHE-RO Initiative

Purpose: To follow the Integrating Healthcare Enterprise - Radiation Oncology (IHE-RO) initiative of proper cross-vendor technology integration, an automated chart checker (ACC) was developed. ACC compares extracted data from an approved patient plan in the Eclipse treatment planning system (TPS) against data existing in the Mosaiq treatment management system (TMS). ACC automatically analyzes these parameters using built-in quality checklists to provide further aid in chart review. Methods: Eclipse TPS data are obtained using Eclipse scripting API (ESAPI) while Mosaiq TMS data are obtained from a radiotherapy-treatment-planning (RTP) file. Using this information, ACC identifies TPS-TMS discrepancies in 18 primary beam parameters including MU, energy, jaw positions, gantry angle, table angle, accessories, and bolus for up to 31 beams. Next, approximately 40 items from traditional quality checklists are evaluated such as prescription consistency, DRR graticule placement, plan approval status, global max dose, and dose tracking coefficients. Parameters were artificially modified to determine if ACC would detect an error in data transfer and to test each component of quality checklists. Results: Using ESAPI scripting and RTP file-processing, ACC was able to properly aggregate data from TPS and TMS for up to 31 beams. Errors were artificially introduced into each plan parameter, and ACC was able to successfully detect all of them within seconds. Next, ACC was able to successfully detect mistakes in the chart by identifying deviations with its quality checklists, within seconds. Conclusion: ACC effectively addresses the potential issue of faulty cross-vendor data transfer, as described by IHE-RO. In addition, ACC was also able to detect deviations from its built-in quality checklists. ACC is already an invaluable tool for efficient and standardized chart review and will continue to improve as its incorporated checklists become more comprehensive.

60 APPLIED LIFE SCIENCES↗

Scheduling Algorithm for Mission Planning and Logistics Evaluation (SAMPLE). Volume 1: User's guide

An interactive computer program for automatically generating traffic models for the Space Transportation System (STS) is presented. Information concerning run stream construction, input data, and output data is provided. The flow of the interactive data stream is described. Error messages are specified, along with suggestions for remedial action. In addition, formats and parameter definitions for the payload data set (payload model), feasible combination file, and traffic model are documented.

Dupnick, E.↗

Automatic arc welding of propulsion system tubing in close proximity to sensitive electronic devices

The planned final assembly of the Galileo spacecraft propulsion system tubing, which involves welding in close proximity to sensitive electronics, raised significant concerns about the effects of electromagnetic coupling of weld energy on CMOS and other sensitive integrated circuits. A test program was established to assess the potential of an orbital arc welder and an RF-induction brazing machine to damage sensitive electronic equipment. Test parameters were varied to assess the effectiveness of typical transient suppression practices such as grounding, bonding, and shielding. A technique was developed to calibrate the hazard levels at the victim-circuit location; this technique is described along with the results and conclusions of the test program.

Lumsden, J. M.↗

SU-G-TeP4-02: A Method for Evaluating the Direct Impact of Failed IMRT QAs On Patient Dose

Purpose: We developed a method to calculate patient doses corresponding to IMRT QA measurements in order to determine and assess the actual dose delivered for plans with failed (or borderline) IMRT QA. This work demonstrates the feasibility of automatically computing delivered patient dose from portal dosimetry measurements in the Varian TPS system, which would provide a valuable and clinically viable IMRT QA tool for physicists and physicians. Methods: IMRT QA fluences were measured using portal dosimetry, processed using in-house matlab software, and imported back into Eclipse to calculate dose on the planning CT. To validate the proposed workflow, the Eclipse calculated portal dose for a 5-field sliding window prostate boost plan was processed as described above. The resulting dose was compared to the planned dose and found to be within 0.5 Gy. Two IMRT QA results for the prostate boost plan (one that failed and one that passed) were processed and the resulting patient doses were evaluated. Results: The max dose difference between IMRT QA #1 and the original planned and approved dose is 4.5 Gy, while the difference between the planned and IMRT QA #2 dose is 4.0 Gy. The inferior portion of the PTV is slightly underdosed in both plans, and the superior portion is slightly overdosed. The patient dose resulting from IMRT QA #1 and #2 differs by only 0.5 Gy. With this new information, it may be argued that the evaluated plan alteration to obtain passing gamma analysis produced clinically irrelevant differences. Conclusion: Evaluation of the delivered QA dose on the planning CT provides valuable information about the clinical relevance of failed or borderline IMRT QAs. This particular workflow demonstrates the feasibility of pushing the measured IMRT QA portal dosimetry results directly back onto the patient planning CT within the Varian system.

60 APPLIED LIFE SCIENCES↗

A method to evaluate dose errors introduced by dose mapping processes for mass conserving deformations

Purpose: To present a method to evaluate the dose mapping error introduced by the dose mapping process. In addition, apply the method to evaluate the dose mapping error introduced by the 4D dose calculation process implemented in a research version of commercial treatment planning system for a patient case. Methods: The average dose accumulated in a finite volume should be unchanged when the dose delivered to one anatomic instance of that volume is mapped to a different anatomic instance--provided that the tissue deformation between the anatomic instances is mass conserving. The average dose to a finite volume on image S is defined as d{sub S}=e{sub s}/m{sub S}, where e{sub S} is the energy deposited in the mass m{sub S} contained in the volume. Since mass and energy should be conserved, when d{sub S} is mapped to an image R(d{sub S{yields}R}=d{sub R}), the mean dose mapping error is defined as {Delta}d{sub m}=|d{sub R}-d{sub S}|=|e{sub R}/m{sub R}-e{sub S}/m{sub S}|, where the e{sub R} and e{sub S} are integral doses (energy deposited), and m{sub R} and m{sub S} are the masses within the region of interest (ROI) on image R and the corresponding ROI on image S, where R and S are the two anatomic instances from the same patient. Alternatively, application of simple differential propagation yields the differential dose mapping error, {Delta}d{sub d}=|({partial_derivative}d/{partial_derivative}e)*{Delta}e+({partial_derivative}d/{partial_derivative}m)*{Delta}m|=|((e{sub S}-e{sub R})/m{sub R})-((m{sub S}-m{sub R})/m{sub R}{sup 2})*e{sub R}|={alpha}|d{sub R}-d{sub S}| with {alpha}=m{sub S}/m{sub R}. A 4D treatment plan on a ten-phase 4D-CT lung patient is used to demonstrate the dose mapping error evaluations for a patient case, in which the accumulated dose, D{sub R}={Sigma}{sub S=0}{sup 9}d{sub S{yields}R}, and associated error values ({Delta}D{sub m} and {Delta}D{sub d}) are calculated for a uniformly spaced set of ROIs. Results: For the single sample patient dose distribution, the average accumulated differential dose mapping error is 4.3%, the average absolute differential dose mapping error is 10.8%, and the average accumulated mean dose mapping error is 5.0%. Accumulated differential dose mapping errors within the gross tumor volume (GTV) and planning target volume (PTV) are lower, 0.73% and 2.33%, respectively. Conclusions: A method has been presented to evaluate the dose mapping error introduced by the dose mapping process. This method has been applied to evaluate the 4D dose calculation process implemented in a commercial treatment planning system. The method could potentially be developed as a fully-automatic QA method in image guided adaptive radiation therapy (IGART).

61 RADIATION PROTECTION AND DOSIMETRY↗

Intelligent Pilot Aids for Flight Re-Planning in Emergencies

Experimental studies were conducted with pilots to investigate the attributes of automation that would be appropriate for aiding pilots in emergencies. The specific focus of this year was on methods of mitigating automation brittleness. Brittleness occurs when the automatic system is used in circumstances it was not designed for, causing it to choose an incorrect action or make an inaccurate decision for the situation. Brittleness is impossible to avoid since it is impossible to predict every potential situation the automatic system will be exposed to over its life. However, operators are always ultimately responsible for the actions and decisions of the automation they are monitoring or using, which means they must evaluate the automation's decisions and actions for accuracy. As has been pointed out, this is a difficult thing for human operators to do. There have been various suggestions as to how to aid operators with this evaluation. In the study described in this report we studied how presentation of contextual information about an automatic system's decision might impact the ability of the human operators to evaluate that decision. This study focused on the planning of emergency descents. Fortunately, emergencies (e.g., mechanical or electrical malfunction, on-board fire, and medical emergency) happen quite rarely. However, they can be catastrophic when they do. For all predictable or conceivable emergencies, pilots have emergency procedures that they are trained on, but those procedures often end with 'determine suitable airport and land as quickly as possible.' Planning an emergency descent to an unplanned airport is a difficult task, particularly under the time pressures of an emergency. Automatic decision aids could be very efficient at the task of determining an appropriate airport and calculating an optimal trajectory to that airport. This information could be conveyed to the pilot through an emergency descent procedure listing all of the actions necessary to safely land the plane. However, there is still the potential problem of brittleness. This study examined the impact of contextual information in presentations of emergency descent procedures to see if they might impact the pilot's evaluation of the feasibility of the presented procedure. The study and its results are described in detail.

Pritchett, Amy R.↗