Search NASA⌕ Search

SEARCH · Search NASA

Results for “BEAM FOCUSING MAGNETS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Amplification due to two-stream instability of self-electric and magnetic fields of an ion beam propagating in background plasma

Propagation of charged particle beams in background plasma as a method of space charge neutralization has been shown to achieve a high degree of charge and current neutralization and therefore enables nearly ballistic propagation and focusing of charged particle beams. Correspondingly, the use of plasmas for propagation of charged particle beams has important applications for transport and focusing of intense particle beams in inertial fusion and high energy density laboratory plasma physics. However, the streaming of beam ions through a background plasma can lead to the development of two-stream instability between the beam ions and the plasma electrons. The beam electric and magnetic fields enhanced by the two-stream instability can lead to defocusing of the ion beam. Using particle-in-cell simulations, we study the scaling of the instability-driven self-electromagnetic fields and consequent defocusing forces with the background plasma density and beam ion mass. In conclusion, we identify plasma parameters where the defocusing forces can be reduced.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Long-Working-Distance Kirkpatrick-Baez Mirrors for Hard X-ray Beamlines at SPring-8

We designed and installed two types of long-working-distance Kirkpatrick-Baez (KB) mirrors and mirror manipulators, which were customized into each experiment for hard x-ray undulator beamlines at SPring-8. For the BL32XU RIKEN Targeted Proteins beamline, 400-mm-long KB focusing mirrors for a beam size of 1 {mu}m with a 730-mm-long working distance were designed for carrying out the structural analysis of protein microcrystals. We realized a focusing beam size of 0.9x0.9 {mu}m{sup 2}(FWHM) and a focusing intensity of 6x10{sup 10} (photons/s) at an x-ray energy of 12.4 keV. For the BL19LXU RIKEN SR Physics beamline, we developed KB mirrors for 100-nm focusing with a 100-mm-working distance for the purpose of nano-focus x-ray diffraction. A focusing beam size of 100x100 nm{sup 2}(FWHM) and a high focusing intensity of 3.7x10{sup 10} (photons/s) at an x-ray energy of 12.4 keV were realized.

43 PARTICLE ACCELERATORS↗

A novel electron gun for inline MRI-linac configurations

Purpose: This work introduces a new electron gun geometry capable of robust functioning in the presence of a high strength external magnetic field for axisymmetric magnetic resonance imaging (MRI)-linac configurations. This allows an inline MRI-linac to operate without the need to isolate the linear accelerator (linac) using a magnetic shield. This MRI-linac integration approach not only leaves the magnet homogeneity unchanged but also provides the linac flexibility to move along the magnet axis of symmetry if the source to target distance needs to be adjusted. Methods: Simple electron gun geometry modifications of a Varian 600C electron gun are considered and solved in the presence of an external magnetic field in order to determine a set of design principles for the new geometry. Based on these results, a new gun geometry is proposed and optimized in the fringe field of a 0.5 T open bore MRI magnet (GE Signa SP). A computer model for the 6 MeV Varian 600C linac is used to determine the capture efficiency of the new electron gun-linac system in the presence of the fringe field of the same MRI scanner. The behavior of the new electron gun plus the linac system is also studied in the fringe fields of two other magnets, a 1.0 T prototype open bore magnet and a 1.5 T GE Conquest scanner. Results: Simple geometrical modifications of the original electron gun geometry do not provide feasible solutions. However, these tests show that a smaller transverse cathode diameter with a flat surface and a slightly larger anode diameter could alleviate the current loss due to beam interactions with the anode in the presence of magnetic fields. Based on these findings, an initial geometry resembling a parallel plate capacitor with a hole in the anode is proposed. The optimization procedure finds a cathode-anode distance of 5 mm, a focusing electrode angle of 5°, and an anode drift tube length of 17.1 mm. Also, the linac can be displaced with ±15 cm along the axis of the 0.5 T magnet without capture efficiency reduction below the experimental value in zero field. In this range of linac displacements, the electron beam generated by the new gun geometry is more effectively injected into the linac in the presence of an external magnetic field, resulting in approximately 20% increase of the target current compared to the original gun geometry behavior at zero field. The new gun geometry can generate and accelerate electron beams in external magnetic fields without current loss for fields higher than 0.11 T. The new electron-gun geometry is robust enough to function in the fringe fields of the other two magnets with a target current loss of no more than 16% with respect to the current obtained with no external magnetic fields. Conclusions: In this work, a specially designed electron gun was presented which can operate in the presence of axisymmetric strong magnetic fringe fields of MRI magnets. Computer simulations show that the electron gun can produce high quality beams which can be injected into a straight through linac such as Varian 600C and accelerated with more efficiency in the presence of the external magnetic fields. Also, the new configuration allows linac displacements along the magnet axis in a range equal to the diameter of the imaging spherical volume of the magnet under consideration. The new electron gun-linac system can function in the fringe field of a MRI magnet if the field strength at the cathode position is higher than 0.11 T. The capture efficiency of the linac depends on the magnetic field strength and the field gradient. The higher the gradient the better the capture efficiency. The capture efficiency does not degrade more than 16%.

43 PARTICLE ACCELERATORS↗

High-Voltage Breakdown Penalties for the Beam-Breakup Instability

The strength of the dangerous beam breakup (BBU) instability in linear induction accelerators (LIAs) is determined by the transverse coupling impedance Z ⊥ of the induction cell cavity. For accelerating gap width w less than the beam pipe radius b, the transverse impedance is theoretically proportional to w/b, favoring narrow gaps to suppress BBU. On the other hand, cells with narrow gaps cannot support high accelerating gradients, because of electrical breakdown and shorting of the gap. Thus, there is an engineering trade-off between BBU growth and accelerating gradient, which must be considered for next generation LIAs now being designed. In this article this tradeoff is explored, using a simple pillbox cavity as an illustrative example. For this model, widening the gap to reduce the probability of breakdown increases BBU growth, unless higher magnetic focusing fields are used to further suppress the instability.

43 PARTICLE ACCELERATORS↗

VERDI: VERsatile DIffractometer with wide-angle polarization analysis for magnetic structure studies in powders and single crystals

The VERsatile DIffractometer will set a new standard for a world-class magnetic diffractometer with versatility for both powder and single crystal samples and capability for wide-angle polarization analysis. The instrument will utilize a large single-frame bandwidth and will offer high-resolution at low momentum transfers and excellent signal-to-noise ratio. A horizontal elliptical mirror concept with interchangeable guide pieces will provide high flexibility in beam divergence to allow for a high-resolution powder mode, a high-intensity single crystal mode, and a polarized beam option. A major science focus will be quantum materials that exhibit emergent properties arising from collective effects in condensed matter. The unique use of polarized neutrons to isolate the magnetic signature will provide optimal experimental input to state-of-the-art modeling approaches to access detailed insight into local magnetic ordering.

36 MATERIALS SCIENCE↗

Magnetic electron collimation in three-dimensional semi-metals

While electrons moving perpendicular to a magnetic field are confined to cyclotron orbits, they can move freely parallel to the field. This simple fact leads to complex current flow in clean, low carrier density semi-metals, such as long-ranged current jets forming along the magnetic field when currents pass through point-like constrictions. Occurring accidentally at imperfect current injection contacts, the phenomenon of "current jetting" plagues the research of longitudinal magneto-resistance, which is particularly important in topological conductors. Here we demonstrate the controlled generation of tightly focused electron beams in a new class of micro-devices machined from crystals of the Dirac semi-metal Cd 3 As 2 . The current beams can be guided by tilting a magnetic field and their range tuned by the field strength. Finite element simulations quantitatively capture the voltage induced at faraway contacts when the beams are steered towards them, supporting the picture of controlled electron jets. These experiments demonstrate direct control over the highly non-local signal propagation unique to 3D semi-metals in the current jetting regime, and may lead to applications akin to electron optics in free space.

36 MATERIALS SCIENCE↗

Neutron spectra from beam-target reactions in dense Z-pinches

The energy spectrum of neutrons emitted by a range of deuterium and deuterium-tritium Z-pinch devices is investigated computationally using a hybrid kinetic-MHD model. 3D MHD simulations are used to model the implosion, stagnation, and break-up of dense plasma focus devices at currents of 70 kA, 500 kA, and 2 MA and also a 15 MA gas puff. Instabilities in the MHD simulations generate large electric and magnetic fields, which accelerate ions during the stagnation and break-up phases. A kinetic model is used to calculate the trajectories of these ions and the neutron spectra produced due to the interaction of these ions with the background plasma. It is found that these beam-target neutron spectra are sensitive to the electric and magnetic fields at stagnation resulting in significant differences in the spectra emitted by each device. Most notably, magnetization of the accelerated ions causes the beam-target spectra to be isotropic for the gas puff simulations. It is also shown that beam-target spectra can have a peak intensity located at a lower energy than the peak intensity of a thermonuclear spectrum. A number of other differences in the shapes of beam-target and thermonuclear spectra are also observed for each device. Finally, significant differences between the shapes of beam-target DD and DT neutron spectra, due to differences in the reaction cross-sections, are illustrated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hard X-ray polarizer to enable simultaneous three-dimensional nanoscale imaging of magnetic structure and lattice strain

Recent progress in the development of dichroic Bragg coherent diffractive imaging, a new technique for simultaneous three-dimensional imaging of strain and magnetization at the nanoscale, is reported. This progress includes the installation of a diamond X-ray phase retarder at beamline 34-ID-C of the Advanced Photon Source. Here, the performance of the phase retarder for tuning X-ray polarization is demonstrated with temperature-dependent X-ray magnetic circular dichroism measurements on a gadolinium foil in transmission and on a Gd 5 Si 2 Ge 2 crystal in diffraction geometry with a partially coherent, focused X-ray beam. Feasibility tests for dichroic Bragg coherent diffractive imaging are presented. These tests include (1) using conventional Bragg coherent diffractive imaging to determine whether the phase retarder introduces aberrations using a nonmagnetic gold nanocrystal as a control sample, and (2) collecting coherent diffraction patterns of a magnetic Gd 5 Si 2 Ge 2 nanocrystal with left- and right-circularly polarized X-rays. Future applications of dichroic Bragg coherent diffractive imaging for the correlation of strain and lattice defects with magnetic ordering and inhomogeneities are considered.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accelerator Physics at NSLS-II: Research Accomplishments in 2024

NSLS-II accelerator physicists advanced the operational performance and scientific capabilities of NSLS-II, providing regular lattice characterization and correction, injec tion optimization, vertical emittance control, and beam dynamics reports with corre lation analysis. We further developed advanced lattice characterization techniques and studies on impedance, beam-induced heating, and higher-harmonic RF cavity effects to support NSLS-II and its high-brightness upgrade. The assessment of free-electron laser options for the NSLS-II upgrade has been completed. We carried out comprehensive studies focused on complex bend magnets and novel efficient injection schemes for next-generation low-emittance synchrotrons. We contributed to the Electron-Ion Collider project, including Electron Storage Ring lattice design, beam diagnostics, and injector studies. The physicists participated in international collaborations, including the development of Python-based Middle Layer software, and participated in key accel erator physics workshops and scientific meetings. The main research accomplishments achieved in 2024 are summarized in this report.

43 PARTICLE ACCELERATORS↗

Booster Neutrino Flux Prediction at MicroBooNE

The primary source of neutrinos for the MicroBooNE experiment is Fermilab’s Booster Neutrino Beamline. The beamline uses 8 GeV protons from the Booster accelerator steered onto a beryllium target. The secondaries are focused by a magnetic horn down a 50m long decay pipe. Decays of these secondaries give rise to a neutrino beam. We use the beamline simulation and techniques previously developed by the MiniBooNE collaboration to calculate the neutrino flux and estimate systematic uncertainties at the MicroBooNE detector location.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plasma Measurements in High Intensity Electron Beam Diodes

Experiments are being performed on the Self-Magnetic Pinch (SMP) electron beam diode on the RITS-6 accelerator at Sandia National Laboratories. This diode produces a tightly focused electron beam (< 3mm diameter) which is incident on a high atomic number bremsstrahlung x-ray converter. Typical diode parameters are 120 kA, 7 MeV, and 70ns current pulse, giving a ~45ns x-ray pulse. Plasmas from contaminants on the electrode surfaces propagate into the A-K vacuum gap, affecting the impedance, x-ray spectrum, and pulse width. These plasmas are measured using diagnostics, which include: spectroscopy, optical imaging, and photon detection; to obtain velocity, density, and temperature information. These parameters are measured both spatially, using multi-fiber arrays, and temporally, using streak cameras and avalanche photodiodes. Plasma densities and temperatures are determined from detailed, time-dependent, collisional-radiative (CT) and radiation transport (RT) models, which include Stark broadening of the hydrogen-alpha transition line and carbon ion line ratios. These results are combined with hybrid PIC/fluid simulations to model the plasma’s overall behavior. Densities of up to 10^19 cm-3 have been measured on the electrode surfaces, decreasing by several orders of magnitude both radially and axially across the vacuum gap. Electrode plasma expansion velocities of up to 10 cm/microsecond correlate well with the decreasing impedance profile (~0.5 Ohms/ns) observed during the pulse.

electron beam diodes↗

Accelerator Technologies and Science: Progress and Outlook

For over half a century, high-energy particle accelerators play a key role and shape modern nuclear and particle physics, they are also the instruments at the forefront of research for material science and biology. The physics needs continuously push us to invent novel ways to increase energy and improve the performance of accelerators, reduce their cost and make them more power-efficient. Here we briefly overview the most notable accelerator facilities which recently became operational and are now employed for research in nuclear physics, basic energy sciences, neutrinos, high energy particle frontier. We also present upcoming and planned future facilities and outline their main goals, challenges, and required R&D. Focus will be given to the core accelerator technologies such as magnets, RF acceleration, and targets as we as leading beam physics developments such as beam cooling, colliding beams and plasma acceleration.

Shiltsev, Vladimir D.↗

Virtual detector of synchrotron radiation (VDSR) - A C++ parallel code for particle tracking and radiation calculation

The Virtual Detector for Synchrotron Radiation (VDSR) is a parallel C++ code developed to calculate the incoherent radiation from a single charged particle or a beam moving in given external electro-magnetic fields. In this proceedings the code structure and features are introduced. An example of radiation generation from the betatron motion of a beam in the focusing fields of the wake in a laser-plasma accelerator is presented.

43 PARTICLE ACCELERATORS↗

Design concept for a second interaction region for the Electron-Ion Collider

In addition to the day-one primary Interaction Region (IR), the design of the Electron Ion Collider (EIC) must support operation of a 2nd IR potentially added later. The 2nd IR is envisioned in an existing experimental hall at RHIC IP8, compatible with the same beam energy combinations as the 1st IR over the full center of mass energy range of ~20 GeV to ~140 GeV. The 2nd IR is designed to be complementary to the 1st IR. In particular, a secondary focus is added in the forward ion direction of the 2nd IR hadron beamline to optimize its capability in detecting particles with magnetic rigidities close to those of the ion beam. We provide the current design status of the 2nd IR in terms of parameters, magnet layout and beam dynamics.

Gamage, B. R.↗

A conceptual design of an electron spectrometer for ELI-NP

We present the geometry and field parameters of an Electron Spectrometer (ES) with two dipole magnets, considered for electron energy measurements at the High Fields QED experimental area at ELI-NP. The first magnet is a 2 meter long permanent magnet, placed inside the Interaction Chamber (IC). The second magnet is a 1.5 meters long electromagnet, placed outside IC. The pulsed electron beam will be produced by the 10 PW pulsed Laser, ‘pump-beam’, focused into one meter long capillary low density plasma cell. A second 10 PW pulsed Laser, ‘probe-beam’, will interact with the relativistic electron bunch providing the strong electromagnetic field. The ES will measure the subtle changes in the electron energy spectrum as a result of the electron beam interaction with the probe-beam field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Patterning-Induced Ferromagnetism of Fe 3 GeTe 2 van der Waals Materials beyond Room Temperature

Magnetic van der Waals (vdW) materials have emerged as promising candidates for spintronics applications, especially after the recent discovery of intrinsic ferromagnetism in monolayer vdW materials. There has been a critical need for tunable ferromagnetic vdW materials beyond room temperature. Here, we report a real-space imaging study of itinerant ferromagnet Fe 3 GeTe 2 and the enhancement of its Curie temperature well above ambient temperature. We find that the magnetic long-range order in Fe 3 GeTe 2 is characterized by an unconventional out-of-plane stripe-domain phase. In Fe 3 GeTe 2 microstructures patterned by a focused ion beam, the out-of-plane stripe domain phase undergoes a surprising transition at 230 K to an in-plane vortex phase that persists beyond room temperature. Finally, the discovery of tunable ferromagnetism in Fe 3 GeTe 2 materials opens up vast opportunities for utilizing vdW magnets in room-temperature spintronics devices.

36 MATERIALS SCIENCE↗

Nonlinear Tune-Shift Measurements in the Integrable Optics Test Accelerator

The first experimental run of Fermilab’s Integrable Optics Test Accelerator (IOTA) ring aimed at testing the concept of nonlinear integrable beam optics. In this report we present the preliminary results of the studies of a nonlinear focusing system with two invariants of motion realized with the special elliptic-potential magnet. The key measurement of this experiment was the horizontal and vertical betatron tune shift as a function of transverse amplitude. A vertical kicker strength was varied to change the betatron amplitude for several values of the nonlinear magnet strength. The turn-by-turn positions of the 100 MeV electron beam at twenty-one beam position monitors around the ring were captured and used for the analysis of phase-space trajectories.

43 PARTICLE ACCELERATORS↗

Design of the LBNF Beamline

The Long Baseline Neutrino Facility (LBNF) will utilize a beamline located at Fermilab to carry out a compelling research program in neutrino physics. The facility will aim a wide band neutrino beam toward underground detectors placed at the SURF Facility in South Dakota, about 1,300 km away. The main elements of the facility are a primary proton beamline and a neutrino beamline. The primary proton beam (60-120 GeV) will be extracted from the MI-10 section of Fermilab’s Main Injector. Neutrinos are produced after the protons hit a solid target and produce mesons which are subsequently focused by magnetic horns into a 204 m long decay pipe where they decay into muons and neutrinos. The parameters of the facility were determined taking into account the physics goals, spacial and radiological constraints and the experience gained by operating the NuMI facility at Fermilab. The initial proton beam power is expected to be 1.2 MW; however, the facility is designed to be upgradeable to 2.4 MW. We discuss here the design status and the associated challenges as well as plans for improvements before baselining the facility.

43 PARTICLE ACCELERATORS↗